The scientific evaluation on heat insulation and preservation capacity of rammed earth construction can provide an effective evidence for its superiority in preserving thermal environment of the construction. By takin...The scientific evaluation on heat insulation and preservation capacity of rammed earth construction can provide an effective evidence for its superiority in preserving thermal environment of the construction. By taking an eco-hotel in Zhejiang Anji County as the research object, 33 test points have been set. The indoor and outdoor air temperature of eco-hotel and the surface temperature of building envelopes had been recorded by using data acquisition instrument, temperature transmitter and other equipments from January 27 to February 2 in 2007. Then, the data of a period had been selected for comparison and analysis and the results had been obtained as follows. In January when the temperature difference between day and night in Anji was not large, without particular thermal insulation measures and equipments, the indoor temperature of eco-hotel fluctuated very little, showing that rammed earth construction was of obvious capacity for heat preservation and insulation, that its heat stability was evident and that it could ensure excellent indoor thermal environment.展开更多
Variations in acceleration and excess pore water pressure during a seismic event are critical early-warning indicators of an impending dam collapse.To assess these variations,the seismic responses for three simplified...Variations in acceleration and excess pore water pressure during a seismic event are critical early-warning indicators of an impending dam collapse.To assess these variations,the seismic responses for three simplified model dams,based on cross-sections through a real earthen dam,were assessed with numerical simulations and centrifuge tests.A normalized root-mean-square error was utilized as a comparison index to assess the closeness between simulated and the recorded values.Assuming that the experimental records are reliable,the reliability of the numerical program was evaluated using this root-mean-square error estimation approach.Explanations for inconsistency between the two approaches are presented.The conclusions are drawn from the results of the three model dams.展开更多
In this paper, field measurements and pullout tests of a new type of reinforced earth retaining wall, which is reinforced by trapezoid concrete blocks connected by steel bar, are described. Field measurements included...In this paper, field measurements and pullout tests of a new type of reinforced earth retaining wall, which is reinforced by trapezoid concrete blocks connected by steel bar, are described. Field measurements included settlements of the earth fill, tensile forces in the ties and earth pressures on the facing panels during the construction and at completion. Based on the measurements, the following statements can be made: (1) the tensile forces in the ties increased with the height of backfill above the tie and there is a tensile force crest in most ties; (2) at completion, the measured earth pressures along the wall face were between the values of the active earth pressures and the pressures at rest; (3) larger settlements occurred near the face of the wall where a zone of drainage sand and gravel was not compacted properly and smaller settlements occurred in the well-compacted backfill. The results of field pullout tests indicated that the magnitudes of pullout resistances as well as tensile forces induced in the ties were strongly influenced by the relative displacements between the ties and the backfill, and pullout resistances increased with the height of backfill above the ties and the length of ties.展开更多
基金Supported by Fund of Key Scientific and Technological Project of Henan Province (10210210080)Henan Government Decision-making Research Bidding Project (2011B706)~~
文摘The scientific evaluation on heat insulation and preservation capacity of rammed earth construction can provide an effective evidence for its superiority in preserving thermal environment of the construction. By taking an eco-hotel in Zhejiang Anji County as the research object, 33 test points have been set. The indoor and outdoor air temperature of eco-hotel and the surface temperature of building envelopes had been recorded by using data acquisition instrument, temperature transmitter and other equipments from January 27 to February 2 in 2007. Then, the data of a period had been selected for comparison and analysis and the results had been obtained as follows. In January when the temperature difference between day and night in Anji was not large, without particular thermal insulation measures and equipments, the indoor temperature of eco-hotel fluctuated very little, showing that rammed earth construction was of obvious capacity for heat preservation and insulation, that its heat stability was evident and that it could ensure excellent indoor thermal environment.
基金Sponsored by the Taiwan Water Corporation under the Seismic Evaluation of JenYiTan Dam project,Academia Sinica (Taipei) and the National Sciences Council under Grant (NSC94-2119-M-001-016)
文摘Variations in acceleration and excess pore water pressure during a seismic event are critical early-warning indicators of an impending dam collapse.To assess these variations,the seismic responses for three simplified model dams,based on cross-sections through a real earthen dam,were assessed with numerical simulations and centrifuge tests.A normalized root-mean-square error was utilized as a comparison index to assess the closeness between simulated and the recorded values.Assuming that the experimental records are reliable,the reliability of the numerical program was evaluated using this root-mean-square error estimation approach.Explanations for inconsistency between the two approaches are presented.The conclusions are drawn from the results of the three model dams.
文摘In this paper, field measurements and pullout tests of a new type of reinforced earth retaining wall, which is reinforced by trapezoid concrete blocks connected by steel bar, are described. Field measurements included settlements of the earth fill, tensile forces in the ties and earth pressures on the facing panels during the construction and at completion. Based on the measurements, the following statements can be made: (1) the tensile forces in the ties increased with the height of backfill above the tie and there is a tensile force crest in most ties; (2) at completion, the measured earth pressures along the wall face were between the values of the active earth pressures and the pressures at rest; (3) larger settlements occurred near the face of the wall where a zone of drainage sand and gravel was not compacted properly and smaller settlements occurred in the well-compacted backfill. The results of field pullout tests indicated that the magnitudes of pullout resistances as well as tensile forces induced in the ties were strongly influenced by the relative displacements between the ties and the backfill, and pullout resistances increased with the height of backfill above the ties and the length of ties.