This paper presents a numerical case study of heat transfer mechanisms during the charging process of a stratified thermal storage tank applied in a specific adsorption heat pump cycle. The effective thermal conductiv...This paper presents a numerical case study of heat transfer mechanisms during the charging process of a stratified thermal storage tank applied in a specific adsorption heat pump cycle. The effective thermal conductivity of the heat transfer fluid during the charging process is analyzed through CFD simulations using Unsteady Reynolds-averaged Navier-Stokes equations (URANS). The aim of the study is to provide an equivalent thermal conductivity for a one-dimensional storage tank model to be used in a system simulation of the complete adsorption heat pump cycle. The influence of the turbulent mixing and also the advection effect due to fluid bulk motion are investigated. The results show that in the case considered here, the turbulence effect on the effective thermal conductivity is more considerable than the advection effect.展开更多
This paper presented a preliminary research on the central solar heating system with seasonal storage(CSHSSS)used in cold climate in China.A mathematical model of the solar energy seasonal storage water tank used in t...This paper presented a preliminary research on the central solar heating system with seasonal storage(CSHSSS)used in cold climate in China.A mathematical model of the solar energy seasonal storage water tank used in the central solar heating system was firstly developed based on energy conservation.This was followed by the simulation of the CSHSSS used in a two-floor villa in Harbin,and analysis of the impacts on storage water temperature of tank volume,solar collector area,tank burial depth,insulation thickness around the tank,etc.The results show there is a relatively economical tank volume to optimize the system efficiency,which decreases with increasing tank volume at the constant collector area,and increases with increasing collector area at the constant tank volume.Furthermore,the insulation thickness has obvious effect on avoiding heat loss,while the tank burial depth doesn't.In addition,the relationship between the solar collector efficiency and storage water temperature is also obtained,it decreases quickly with increasing storing water temperature,and then increases slowly after starting space heating system.These may be helpful for relevant design and optimization in cold climates in China and all over the world.展开更多
To reduce the influence of thermal effects during discharge process for natural gas applications as vehicular fuel,the authors established a mathematical model of methane storage tank system during discharge process a...To reduce the influence of thermal effects during discharge process for natural gas applications as vehicular fuel,the authors established a mathematical model of methane storage tank system during discharge process and solved the equations by method of Newton-Raphson and iterative algorithm. The results reveal that the lowest temperature occurs in the center of tank with temperature drop of 49. 14 ℃,the average temperature drop of system is 42. 78 ℃,and the discharge amount is 2. 733 kg,with a performance loss approaching 24. 5% at the discharge rate of 1. 315 g/s. The inner temperature and discharge amounts can be changed by heating the wall of tank and increasing the thermal conductivity coefficient of adsorbents. Average temperature drop of system is about 20. 1 ℃ and discharge amount is up to 3. 2065 kg,corresponding to discharge efficiency loss of 11. 47% by changing the thermal conductivity from 0. 2 to 0. 5 and the wall temperature from 20 ℃ to 50 ℃. The research on discharge dynamic performance at different discharge rates indicates that the heat supplied by tank wall is larger than natural convection does.展开更多
Solar heating system is widely used recently. Heat storage equipment is the guarantee for steady performance of solar heating system. A design of latent heat storage exchanger with submerged coil was introduced with t...Solar heating system is widely used recently. Heat storage equipment is the guarantee for steady performance of solar heating system. A design of latent heat storage exchanger with submerged coil was introduced with the structure, working principle, and the main advantages. This heat exchanger was integrated into solar heating system as the heat storage equipment. Advantage comparison of the designed heat exchanger in solar heating system with hot water tank was carried out. The analysis results show that the latent heat storage exchanger is superior to hot water tank obviously. The heat exchanger performance parameters and variations of these parameters are got: (1) with the increase of phase change material (PCM) volume ratio, heat storage equipment volume ratio decreases; (2) heat storage efficiency has the same varying tendency with outdoor and air temperature; while the bigger PCM volume ratio is, the weaker the effect of outdoor air temperature on heat storage efficiency is; (3) heat storage capacity and heat storage efficiency increase together; when PCM volume ratio is big, heat storage efficiency is high and the system can begin operating effcienfly and quickly; (4) with the increase of heat storage capacity, life cyde operation cost (LCOC) of system increases gradually in high speed; but with the increase of PCM volume ratio, the difference between the two systems LCOCs becomes smaller and smaller; (5) the reasonable range of PCM volume ratio is 0.5 - 0.7. Temperature characteristic analysis shows that, with the filled PCM, heat storage medium temperature presents several segments at different time, under conditions of different heat storage capacity and different PCM state.展开更多
In this paper a full theoretical thermal analysis of a large molten salt container,80-foot in diameter and 46-foot high,including a four-foot elliptic shell roof,is presented for two temperatures,the standard 565℃ an...In this paper a full theoretical thermal analysis of a large molten salt container,80-foot in diameter and 46-foot high,including a four-foot elliptic shell roof,is presented for two temperatures,the standard 565℃ and a futuristic 700℃,which substantially improves the efficiency of the molten salt containers through the use of a highly stable chloride salt called SS700(SaltStream 700).The theoretical analysis includes conductive and convective heat transfer analysis in the steel container,elliptic roof shell,the fiberglass insulation,and firebrick insulation,and includes thermal insulation designs to safeguard against energy losses at high temperatures.The underlying soil and the high temperature concrete foundation were analyzed theoretically using conductive heat transfer,however the area surrounding the soil surface around the bottom of the molten salt storage tank had convective heat transfer analysis included.The final designs presented in this paper seek to limit heat losses to a maximum of 250 W/m^(2) while being able to operate at a minimum external ambient temperature of-10℃,which determines the thicknesses of the fiberglass and firebrick insulation.展开更多
In this paper a finite element thermal analysis model-using COMSOL-of a large molten salt container,80-foot in diameter and 46-foot high that includes a four-foot elliptic shell roof,is presented for a futuristic 700...In this paper a finite element thermal analysis model-using COMSOL-of a large molten salt container,80-foot in diameter and 46-foot high that includes a four-foot elliptic shell roof,is presented for a futuristic 700℃ design,which uses a highly stable chloride salt called SS700(SaltStream 700)that improves the efficiency of the tank when compared to the traditional 565℃.The FEA(finite element analysis)includes conductive and convective heat transfer analysis in the steel container,elliptic roof shell,the fiberglass insulation,and firebrick insulation,and includes thermal insulation designs to safeguard against energy losses at high temperatures.The underlying soil and the high temperature concrete foundation were analyzed by finite element using conductive heat transfer,however the area surrounding the soil surface around the bottom of the MS storage tank had convective heat transfer analysis included.The finite elements analyses presented are to verify the final fiberglass and firebrick insulation designs,which seeks to limit heat losses to a maximum of 250 W/m^(2) while being able to operate at a minimum external ambient temperature of-10℃.These results are also compared to previously calculated theoretical results.展开更多
斜温层蓄热罐可以提高热电联产(combined heat and power,CHP)机组在供热期间的调峰能力,因此逐渐向大型化发展,但设计参数对蓄热罐的性能影响较大,且采用目前的性能评估方法效率较低。为此,建立大型蓄热罐的物理模型及数学模型,研究蓄...斜温层蓄热罐可以提高热电联产(combined heat and power,CHP)机组在供热期间的调峰能力,因此逐渐向大型化发展,但设计参数对蓄热罐的性能影响较大,且采用目前的性能评估方法效率较低。为此,建立大型蓄热罐的物理模型及数学模型,研究蓄热过程中斜温层的形成及变化过程,提出斜温层等效容积的概念,同时分析结构参数及运行参数对斜温层等效容积的影响。结果表明:形成稳定斜温层后,随着蓄热量的增加,斜温层厚度变化不大,采用斜温层等效容积可以更高效的评估蓄热罐的性能。比较不同工况下蓄热罐等效容积的相对变化量可知,不同影响因素对斜温层等效容积的影响从高到低排序依次为布水器布置、蓄热流量、高径比和冷热水温差。研究成果为大型蓄热罐的性能评估提供了一种新参考。展开更多
文摘This paper presents a numerical case study of heat transfer mechanisms during the charging process of a stratified thermal storage tank applied in a specific adsorption heat pump cycle. The effective thermal conductivity of the heat transfer fluid during the charging process is analyzed through CFD simulations using Unsteady Reynolds-averaged Navier-Stokes equations (URANS). The aim of the study is to provide an equivalent thermal conductivity for a one-dimensional storage tank model to be used in a system simulation of the complete adsorption heat pump cycle. The influence of the turbulent mixing and also the advection effect due to fluid bulk motion are investigated. The results show that in the case considered here, the turbulence effect on the effective thermal conductivity is more considerable than the advection effect.
基金Supported by Multi-Discipline Scientific Rearch Foundation of Harbin Institute of Technology(HIT MD2003.1)Postdoctoral Scientific Rearch Foundation of Heilongjiang Provine(LBH-Q06066)
文摘This paper presented a preliminary research on the central solar heating system with seasonal storage(CSHSSS)used in cold climate in China.A mathematical model of the solar energy seasonal storage water tank used in the central solar heating system was firstly developed based on energy conservation.This was followed by the simulation of the CSHSSS used in a two-floor villa in Harbin,and analysis of the impacts on storage water temperature of tank volume,solar collector area,tank burial depth,insulation thickness around the tank,etc.The results show there is a relatively economical tank volume to optimize the system efficiency,which decreases with increasing tank volume at the constant collector area,and increases with increasing collector area at the constant tank volume.Furthermore,the insulation thickness has obvious effect on avoiding heat loss,while the tank burial depth doesn't.In addition,the relationship between the solar collector efficiency and storage water temperature is also obtained,it decreases quickly with increasing storing water temperature,and then increases slowly after starting space heating system.These may be helpful for relevant design and optimization in cold climates in China and all over the world.
基金Sponsored by the Innovation Program of Chinese Academy of Sciences(Grant No.0907r7,0907z1)
文摘To reduce the influence of thermal effects during discharge process for natural gas applications as vehicular fuel,the authors established a mathematical model of methane storage tank system during discharge process and solved the equations by method of Newton-Raphson and iterative algorithm. The results reveal that the lowest temperature occurs in the center of tank with temperature drop of 49. 14 ℃,the average temperature drop of system is 42. 78 ℃,and the discharge amount is 2. 733 kg,with a performance loss approaching 24. 5% at the discharge rate of 1. 315 g/s. The inner temperature and discharge amounts can be changed by heating the wall of tank and increasing the thermal conductivity coefficient of adsorbents. Average temperature drop of system is about 20. 1 ℃ and discharge amount is up to 3. 2065 kg,corresponding to discharge efficiency loss of 11. 47% by changing the thermal conductivity from 0. 2 to 0. 5 and the wall temperature from 20 ℃ to 50 ℃. The research on discharge dynamic performance at different discharge rates indicates that the heat supplied by tank wall is larger than natural convection does.
基金National Natural Science Foundation of China(No.21106149)
文摘Solar heating system is widely used recently. Heat storage equipment is the guarantee for steady performance of solar heating system. A design of latent heat storage exchanger with submerged coil was introduced with the structure, working principle, and the main advantages. This heat exchanger was integrated into solar heating system as the heat storage equipment. Advantage comparison of the designed heat exchanger in solar heating system with hot water tank was carried out. The analysis results show that the latent heat storage exchanger is superior to hot water tank obviously. The heat exchanger performance parameters and variations of these parameters are got: (1) with the increase of phase change material (PCM) volume ratio, heat storage equipment volume ratio decreases; (2) heat storage efficiency has the same varying tendency with outdoor and air temperature; while the bigger PCM volume ratio is, the weaker the effect of outdoor air temperature on heat storage efficiency is; (3) heat storage capacity and heat storage efficiency increase together; when PCM volume ratio is big, heat storage efficiency is high and the system can begin operating effcienfly and quickly; (4) with the increase of heat storage capacity, life cyde operation cost (LCOC) of system increases gradually in high speed; but with the increase of PCM volume ratio, the difference between the two systems LCOCs becomes smaller and smaller; (5) the reasonable range of PCM volume ratio is 0.5 - 0.7. Temperature characteristic analysis shows that, with the filled PCM, heat storage medium temperature presents several segments at different time, under conditions of different heat storage capacity and different PCM state.
文摘In this paper a full theoretical thermal analysis of a large molten salt container,80-foot in diameter and 46-foot high,including a four-foot elliptic shell roof,is presented for two temperatures,the standard 565℃ and a futuristic 700℃,which substantially improves the efficiency of the molten salt containers through the use of a highly stable chloride salt called SS700(SaltStream 700).The theoretical analysis includes conductive and convective heat transfer analysis in the steel container,elliptic roof shell,the fiberglass insulation,and firebrick insulation,and includes thermal insulation designs to safeguard against energy losses at high temperatures.The underlying soil and the high temperature concrete foundation were analyzed theoretically using conductive heat transfer,however the area surrounding the soil surface around the bottom of the molten salt storage tank had convective heat transfer analysis included.The final designs presented in this paper seek to limit heat losses to a maximum of 250 W/m^(2) while being able to operate at a minimum external ambient temperature of-10℃,which determines the thicknesses of the fiberglass and firebrick insulation.
文摘In this paper a finite element thermal analysis model-using COMSOL-of a large molten salt container,80-foot in diameter and 46-foot high that includes a four-foot elliptic shell roof,is presented for a futuristic 700℃ design,which uses a highly stable chloride salt called SS700(SaltStream 700)that improves the efficiency of the tank when compared to the traditional 565℃.The FEA(finite element analysis)includes conductive and convective heat transfer analysis in the steel container,elliptic roof shell,the fiberglass insulation,and firebrick insulation,and includes thermal insulation designs to safeguard against energy losses at high temperatures.The underlying soil and the high temperature concrete foundation were analyzed by finite element using conductive heat transfer,however the area surrounding the soil surface around the bottom of the MS storage tank had convective heat transfer analysis included.The finite elements analyses presented are to verify the final fiberglass and firebrick insulation designs,which seeks to limit heat losses to a maximum of 250 W/m^(2) while being able to operate at a minimum external ambient temperature of-10℃.These results are also compared to previously calculated theoretical results.
文摘斜温层蓄热罐可以提高热电联产(combined heat and power,CHP)机组在供热期间的调峰能力,因此逐渐向大型化发展,但设计参数对蓄热罐的性能影响较大,且采用目前的性能评估方法效率较低。为此,建立大型蓄热罐的物理模型及数学模型,研究蓄热过程中斜温层的形成及变化过程,提出斜温层等效容积的概念,同时分析结构参数及运行参数对斜温层等效容积的影响。结果表明:形成稳定斜温层后,随着蓄热量的增加,斜温层厚度变化不大,采用斜温层等效容积可以更高效的评估蓄热罐的性能。比较不同工况下蓄热罐等效容积的相对变化量可知,不同影响因素对斜温层等效容积的影响从高到低排序依次为布水器布置、蓄热流量、高径比和冷热水温差。研究成果为大型蓄热罐的性能评估提供了一种新参考。