Microcystins ( MCs ) are well known as hepatotoxins produced by blooms of toxic cyanobacteria (blue-green algae) abundant in surface water used as drinking water resource and have drawn attention of environmentali...Microcystins ( MCs ) are well known as hepatotoxins produced by blooms of toxic cyanobacteria (blue-green algae) abundant in surface water used as drinking water resource and have drawn attention of environmentalists world over by leading to adverse health effects. A study on efficiency and reaction kinetics of microcystin-LR ( MC-LR ) degradation by CIO2 was performed. Experimental results indicated that MC-LR was removed by CIO2 effectively and the residual concentration of MC-LR could meet the national guideline(GB5749 - 2006) (1.0 μg · L^-1), the efficiency of removal was in positive correlation to CIO2 dosage and reaction time and in negative correlation to initial concentration of MC-LR and pH value, whereas it was affected by temperature slightly. CIO2 dosage was the most important reaction factor on base of the orthogonal test results. The reaction was second order overall and first order with respect to both CIO2 and MC- LR, and had an activation energy of 78.81 kJ · mo1^-1 . The reaction rate constant was 4.74× 10-^2 L/(mol · min) at 10 ℃. Therefore, oxidation of CIO~ could be taken as an effective technology for removing MC-LR from drinking water resources in traditional drinking water supplies.展开更多
The electromagnetic field under applied AC and DC current in round and rectangular pipe was systematically investigated, then a concept of 'equivalent current density' was proposed for evaluating the inhomogen...The electromagnetic field under applied AC and DC current in round and rectangular pipe was systematically investigated, then a concept of 'equivalent current density' was proposed for evaluating the inhomogeneous electromagnetic pinch force, and the mono-component removal efficiency and the overall removal efficiency of inclusion were formulated. It is founded that flat pipe is superior to round pipe for the electromagnetic removal of inclusion, and DC current can get a higher removal efficiency than A C current due to absence of skin phenomenon. Under usual condition, a removal efficiency of 52% for 10μm inclusion or more than 92% for 20μm inclusion can be achieved by imposing a current density of 3×106A/m2 in a flat pipe.展开更多
基金the National Nature Science Foundation of China(No.50178022)the National863Projects(No.2006AA06Z309)
文摘Microcystins ( MCs ) are well known as hepatotoxins produced by blooms of toxic cyanobacteria (blue-green algae) abundant in surface water used as drinking water resource and have drawn attention of environmentalists world over by leading to adverse health effects. A study on efficiency and reaction kinetics of microcystin-LR ( MC-LR ) degradation by CIO2 was performed. Experimental results indicated that MC-LR was removed by CIO2 effectively and the residual concentration of MC-LR could meet the national guideline(GB5749 - 2006) (1.0 μg · L^-1), the efficiency of removal was in positive correlation to CIO2 dosage and reaction time and in negative correlation to initial concentration of MC-LR and pH value, whereas it was affected by temperature slightly. CIO2 dosage was the most important reaction factor on base of the orthogonal test results. The reaction was second order overall and first order with respect to both CIO2 and MC- LR, and had an activation energy of 78.81 kJ · mo1^-1 . The reaction rate constant was 4.74× 10-^2 L/(mol · min) at 10 ℃. Therefore, oxidation of CIO~ could be taken as an effective technology for removing MC-LR from drinking water resources in traditional drinking water supplies.
文摘The electromagnetic field under applied AC and DC current in round and rectangular pipe was systematically investigated, then a concept of 'equivalent current density' was proposed for evaluating the inhomogeneous electromagnetic pinch force, and the mono-component removal efficiency and the overall removal efficiency of inclusion were formulated. It is founded that flat pipe is superior to round pipe for the electromagnetic removal of inclusion, and DC current can get a higher removal efficiency than A C current due to absence of skin phenomenon. Under usual condition, a removal efficiency of 52% for 10μm inclusion or more than 92% for 20μm inclusion can be achieved by imposing a current density of 3×106A/m2 in a flat pipe.