The performance of a 3-phase 6-pole 400 W inverter-drive induction motor was investigated using a variety of non-oriented electrical steels for stator core at PWM inverter fundamental wave frequencies of 30 to 300 Hz....The performance of a 3-phase 6-pole 400 W inverter-drive induction motor was investigated using a variety of non-oriented electrical steels for stator core at PWM inverter fundamental wave frequencies of 30 to 300 Hz. There existed an optimum Si content of the material depending on the tooth flux density. Both reduction of material thickness and stress-relief annealing of the stator core improved the motor efficiency. The influence of Si content on the efficiency was small at lower PWM frequencies, while at higher frequencies the motor efficiency increased with increasing Si content. The Cu loss WC increased and the Fe loss Wi counteractiveiy decreasedwith increasing Si content at lower frequencies; while at higher frequencies Wi had dominant effect on the efficiency. Newly developed materials RMA, having lower Fe losses after stress-relief annealing and higher flux densities with lower Si contents, showed motor efficiencies superior to conventional J1S grade materials with comparable Fe losses.展开更多
文摘The performance of a 3-phase 6-pole 400 W inverter-drive induction motor was investigated using a variety of non-oriented electrical steels for stator core at PWM inverter fundamental wave frequencies of 30 to 300 Hz. There existed an optimum Si content of the material depending on the tooth flux density. Both reduction of material thickness and stress-relief annealing of the stator core improved the motor efficiency. The influence of Si content on the efficiency was small at lower PWM frequencies, while at higher frequencies the motor efficiency increased with increasing Si content. The Cu loss WC increased and the Fe loss Wi counteractiveiy decreasedwith increasing Si content at lower frequencies; while at higher frequencies Wi had dominant effect on the efficiency. Newly developed materials RMA, having lower Fe losses after stress-relief annealing and higher flux densities with lower Si contents, showed motor efficiencies superior to conventional J1S grade materials with comparable Fe losses.