期刊文献+
共找到3,441篇文章
< 1 2 173 >
每页显示 20 50 100
Study Progress Analysis of Effluent Quality Prediction in Activated Sludge Process Based on CiteSpace
1
作者 Kemeng Xue 《Journal of Water Resource and Protection》 CAS 2024年第6期450-465,共16页
In this paper, CiteSpace, a bibliometrics software, was adopted to collect research papers published on the Web of Science, which are relevant to biological model and effluent quality prediction in activated sludge pr... In this paper, CiteSpace, a bibliometrics software, was adopted to collect research papers published on the Web of Science, which are relevant to biological model and effluent quality prediction in activated sludge process in the wastewater treatment. By the way of trend map, keyword knowledge map, and co-cited knowledge map, specific visualization analysis and identification of the authors, institutions and regions were concluded. Furthermore, the topics and hotspots of water quality prediction in activated sludge process through the literature-co-citation-based cluster analysis and literature citation burst analysis were also determined, which not only reflected the historical evolution progress to a certain extent, but also provided the direction and insight of the knowledge structure of water quality prediction and activated sludge process for future research. 展开更多
关键词 Biological Model effluent Quality Prediction Activated Sludge Process CITESPACE Knowledge Map Co-Citation Cluster Analysis
下载PDF
Analysis of Effluent Outfall Problems and Their Classification and Regulation Countermeasures
2
作者 Xuexia JIANG Xiange WU 《Agricultural Biotechnology》 2024年第1期62-65,共4页
Effluent outfalls are an important exit for pollutants discharged from the source flowing into environmental water bodies,as well as an important guarantee for the ecological environment of natural water bodies.In res... Effluent outfalls are an important exit for pollutants discharged from the source flowing into environmental water bodies,as well as an important guarantee for the ecological environment of natural water bodies.In response to main problems of large and diverse effluent outfalls,as well as their monitoring analysis,tracing and regulation in China,classification and regulation countermeasures were proposed based on the characteristics of effluent outfalls.It is suggested that a comprehensive management and control system should be built by improving the management and control system,upgrading monitoring techniques and strengthening social supervision and public education,so as to provide a scientific basis for the supervision and management of effluent outfalls in China and help promote the improvement of water quality and the sustainable development and utilization of water resources. 展开更多
关键词 effluent outfalls Monitoring and analysis Classification and regulation Environmental management
下载PDF
Graphene oxide/hydrotalcite modified polyethersulfone nanohybrid membrane for the treatment of lead ion from battery industrial effluent
3
作者 Sinu Poolachira Sivasubramanian Velmurugan 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2023年第8期253-261,共9页
In the present study, polyethersulfone based nanohybrid membranes were effectively fabricated by incorporating graphene oxide(GO) and hydrotalcite(HT) nanosheets into the membrane structure. HT was prepared to overcom... In the present study, polyethersulfone based nanohybrid membranes were effectively fabricated by incorporating graphene oxide(GO) and hydrotalcite(HT) nanosheets into the membrane structure. HT was prepared to overcome the irreversible agglomeration behavior of GO at a high concentration which affects the performance of the membranes. In particular, the shedding of HT in formamide provides a two-dimensional nanosheet with a higher positive charge density to prevent the restacking of GO nanosheets. Here, exfoliated GO and HT with different combinations(1:1, 1:2 and 1:3) were infused in the membrane matrix to treat lead-acid battery effluent effectively. Finally, the hybrid membranes were characterized for hydrophilicity, mechanical strength and pure water flux. In combination with the superior properties of GO and HT, the prepared hybrid membranes can be used as effectively to improve the separation and permeation performance. The phase inversion process eliminated the leaching of nanoparticles from the membrane matrix. The reusability of the hybrid membrane was achieved using0.1 mol·L^(-1)NaOH solution and reused without significant reduction in lead removal efficiency. The cost analysis of the membrane was also estimated from the lab study. Therefore, the present study suggested the selective and sustainable treatment of lead from a real-life effluent. 展开更多
关键词 Nanohybrid membrane POLYETHERSULFONE Graphene oxide HYDROTALCITE Lead battery effluent REUSABILITY Cost analysis
下载PDF
Systematic Biological Upgrade of a Urea Fertilizer Effluent Treatment Plant Using GPS
4
作者 Isyaku Ahmad Joseph T. Akintola +3 位作者 Regina J. Patinvoh Wilson F. Ekpotu Martins C. Obialor Philemon Chukwuebuka Udom 《Open Journal of Applied Sciences》 2023年第8期1457-1477,共21页
The use of modeling and simulation has developed into a critical tool for the sustainable management of wastewater, especially when it comes to replicating the complex biochemical procedures required for fertilizer ef... The use of modeling and simulation has developed into a critical tool for the sustainable management of wastewater, especially when it comes to replicating the complex biochemical procedures required for fertilizer effluent treatment, which calls for a significant amount of wastewater-related data. The biological improvement of a urea fertilizer effluent via GPS* simulation was carried out in this work using a methodical process. Using established analytical techniques, temperature, total suspended solids (TSS), biochemical oxygen demand (BOD), total phosphorus (T/), chemical oxygen demand (COD), total nitrogen (TN), total nitrate (NO<sub>3</sub>), electric conductivity (EC), turbidity, residual chlorine, urea, NH<sub>3</sub>, and heavy metals (Cu, Cd, Cr, Pb, Ni, and Fe) were assessed. The research revealed that the measured values from the fertilizer factory outfall effluent had high concentrations of all the physicochemical water quality indicators, with the exception of TSS, PO<sub>4</sub><sup>-</sup>, SO<sub>4</sub><sup>-</sup>, and NO<sub>3</sub><sup>-</sup>. These concentrations are higher compared to the authorized limits or suggested values by the Federal Environmental Protection Agency (FEPA). To improve the therapy biologically, however, a modeling and simulation program (GPS-X, version 8.0) was used with the physicochemical information gathered from the studied sample. The results of the treated water simulation showed that the concentrations of BOD<sub>5</sub> and COD had been significantly reduced by 35% and 44%, respectively. Additionally, it was discovered that total phosphorus (TP), nitrate (N), and total nitrogen (TN) were all within the permitted FEPA limit. The results revealed good treatment performance of the wastewater with increasing concentration of acetic acid and sodium hydroxide. Hence, the results of this research work identify the need for proper treatment of fertilizer industry effluents prior to their release into the environment. 展开更多
关键词 Fertilizer Wastewater effluent Discharge Basin Outfall Basin Physiochemical Analysis GPS* Modelling & Simulation
下载PDF
Effects of Electroplating Effluents on Growth, Heavy Metals Accumulation and Concentrations in Amaranthus viridis Lin.
5
作者 Ouwoe Surukite O Ogun Mautin L +3 位作者 Ewekeye Touope S Tope-Akinyetun Rachea Asokere Simeon Y Usamot Q 《Journal of Botanical Research》 2023年第3期49-59,共11页
Pollution in recent times has become prevalent due to industrial expansion,hence,releasing pollutants into the environ-ment.Thus,this study aimed at investigating the effects of effluents from electroplating companies... Pollution in recent times has become prevalent due to industrial expansion,hence,releasing pollutants into the environ-ment.Thus,this study aimed at investigating the effects of effluents from electroplating companies on growth,heavy metals accumulation and concentrations in Amaranthus viridis.Seeds of A.viridis were obtained from the National Institute of Hor-ticulture,Ibadan.Loam soils were collected from Lagos State University and two samples of electroplating effluents were obtained from Oregun,Lagos.Seeds were sown,nursed,and transplanted in a uniform bucket filled with 5 kg loam soil and transplanted seedlings were treated with Effluent A(5 and 10%conc.)and Effluent B(5 and 10%conc.)and control respec-tively.Growth parameters such as plant height and so on were measured and plant samples harvested were analyzed for heavy metal concentrations using Atomic Absorption Spectrophotometer.Data collected were subjected to a one-way analysis of variance.Results revealed that Effluents A and B are highly acidic and above discharge limits.Also,the result revealed that 5%conc.of Effluents A and B had more effects on growth(p<0.05)of A.viridis across the harvests than 10%conc.in relation to control.This result showed that the effluent samples affect the growth rhythms of plants.Results further revealed vigorous–1–1 accumulation of the heavy metals:Zn(241.66µg kg±0.10 at third harvest in Effluent A:10%),Cu(68.25µg kg±0.23 at–1–1 first harvest in Effluent B:5%),Cr(500µg kg±0.90 in harvests at all concentrations.)and Ni(500µg kg±0.90 at third harvest in Effluent B:5%)and all these metals are far above the control and permissible limits of WHO/FAO recommenda-tions.From this study,it could be concluded that electroplating effluents had adverse effects on growth and increased metals’bioaccumulation in A.viridis.Therefore,the treatment of effluents to enhance an eco-friendly environment should be done. 展开更多
关键词 ELECTROPLATING effluent Pollution Heavy metals Discharge VEGETABLE Amaranthus viridis
下载PDF
Pollutant emission reduction effect through effluent tax,concentration-based effluent standard,or both 被引量:2
6
作者 Kunyu Niu Zhongshan Tian Jie Xue 《Chinese Journal of Population,Resources and Environment》 2016年第2期68-80,共13页
There are numerous studies comparing different kinds of environmental taxes and standards.However,forms of environmental standards focused by former researchers are usually quantitybased limits/standards(e.g.pounds pe... There are numerous studies comparing different kinds of environmental taxes and standards.However,forms of environmental standards focused by former researchers are usually quantitybased limits/standards(e.g.pounds per day or pounds per unit of output).Concentration-based emission standard(e.g.milligrams per liter of wastewater) as one important form of environmental standard has not been given much attention.In this article,comparable estimates of their probable effect on enterprise pollution reduction will be developed for concentrationbased effluent standards,effluent taxes,and a combination of both.A linear simulation model is used to clearly and obviously compare the effects of effluent taxes and concentration-based standards within the same figure.With one detailed application to the paper industry,some enlightenment and conclusions-as well as the general applicability of these principles-are then provided:Under the same effluent tax rate,enterprises,groups,and industries that are cleaner will reduce more pollutants than those that have higher pollutant abatement costs.It is recommended that effluent taxes are set by avoiding cutting it even at one stroke and considering the feasibility of pollution-reducing technology in various industries.It is necessary to reduce MAC of enterprises to better stimulate enterprises' or industries' emission reduction by preferential measures,such as high tax rate coordinated by speeding up the depreciation of environmental protection equipment. 展开更多
关键词 Concentration-based effluent standard effluent tax emission reduction effect(ERE) marginal abatement cost(MAC)
下载PDF
Effects of different types of nutrient effluent from shrimp ponds on the seedling growth of Kandelia obovata 被引量:1
7
作者 TIAN Yuan CHEN Guangcheng +2 位作者 TANG Feilong ZHENG Chunfang YE Yong 《Acta Oceanologica Sinica》 SCIE CAS CSCD 2018年第6期112-120,共9页
Extensive shrimp ponds are located next to the landward edges of most of mangrove forests in China. A shrimp pond may influence mangroves by(1) routine effluent between pond and tide, and(2) dredging effluent from... Extensive shrimp ponds are located next to the landward edges of most of mangrove forests in China. A shrimp pond may influence mangroves by(1) routine effluent between pond and tide, and(2) dredging effluent from pond-dredging at least once a year. Our study consisted of two experiments to study the effects of these two effluents on the seedling growth of Kandelia obovata. One experiment simulated the effects of routine effluents.The other simulated four sedimentation thicknesses(0 cm, 2 cm, 4 cm, 8 cm) over mangrove soils by dredging effluent from pond-dredging, and revealed the cumulative effects of dredging effluents on K. obovata. At each of the three fixed salinities, i.e., 5, 15 and 25, routine effluent did not result in significant differences in each of the measured growth parameters of K. obovata seedlings. However, effects of dredging effluent on seedling growth of K. obovata were related with sedimentation thickness. Most growth parameters showed maximum values at sedimentation thickness 4 cm. The data indicated that K. obovata accelerated its growth under moderate sedimentation thicknesses and it was tolerant and adaptable to shrimp pond-cleaning effluent sediments up to about 8 cm in our experiment. 展开更多
关键词 routine effluent dredging effluent shrimp pond excessive nutrients biomass allocation MANGROVES
下载PDF
Evaluation of Effluent Discharge from Steel Manufacturing Industries on the Proliferating Environmental Degradation in Nairobi Metropolitan in the Republic of Kenya
8
作者 Patrick K. Kiongo Catherine Njoki Wahome +4 位作者 Peter Muli Muthama Jeniffer Muhonja Linah Ngumba Feisal Hassan Evans Momanyi 《Journal of Geoscience and Environment Protection》 2021年第9期198-226,共29页
The overall objective of this study was to establish the effects of steel industrial effluent on Nairobi metropolitan water system and its impact to the society. The study sought to identify various types of wastes pr... The overall objective of this study was to establish the effects of steel industrial effluent on Nairobi metropolitan water system and its impact to the society. The study sought to identify various types of wastes produced by factories, assess how the waste generated is managed and disposed</span></span><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;">,</span></span></span><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;"> examine the effects of effluent discharge on Nairobi River and finally propose mitigation measures. The research adopted a qualitative design and employed a number of methods: direct observations, document reviews to content analysis of the past studies, which in the end generated invaluable data. The study revealed that there are four categories of waste generated</span></span></span><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;">:</span></span></span><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;"> solid waste, liquid waste, footbath chemicals as well as thermal wastes. It was also found that waste management in place w</span></span></span><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;">as</span></span></span><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;"> not effective enough leading to water and soil pollution. Other causes of pollution were found out to emanate from gasses contamination to the air and chemicals used during steel processing. The findings will inform the community of the harmful effects of untreated water and how it impacts on their health and productivity. It will also help the stakeholders in the environmental conservation to articulate issues of policy and influence agenda setting in the national and sub-national levels. 展开更多
关键词 effluent Emissions Environmental Assessment Environmental Audits Environmental Degradation Environmental Standards Industrial effluents POLLUTION Solid Waste
下载PDF
Startup and operation of anaerobic EGSB reactor treating palm oil mill effluent 被引量:18
9
作者 ZHANG Yejian YAN Li +3 位作者 CHI Lina LONG Xiuhua MEI Zhijian ZHANG Zhenjia 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2008年第6期658-663,共6页
A bench-scale expanded granular sludge bed (EGSB) reactor was applied to the treatment of palm oil mill effluent (POME). The reactor had been operated continuously at 35℃ for 514 d, with organic loading rate (OL... A bench-scale expanded granular sludge bed (EGSB) reactor was applied to the treatment of palm oil mill effluent (POME). The reactor had been operated continuously at 35℃ for 514 d, with organic loading rate (OLR) increased from 1.45 to 17.5 kg COD/(m^3·d). The results showed that the EGSB reactor had good performance in terms of COD removal on the one hand, high COD removal of 91% was obtained at two days' of hydraulic retention time (HRT), and the highest OLR of 17.5 kg COD/(m^3·d). On the other hand, only 46% COD in raw POME was transformed into biogas in which the methane content was about 70% (V/V). A 30-d intermittent experiment indicated that the maximum transformation potential of organic matter in raw POME into methane was 56%. Volatile fatty acid (VFA) accumulation was observed in the later operation stage, and this was settled by supplementing trace metal elements. On the whole, the system exhibited good stability in terms of acidity and alkalinity. Finally, the operational problems inherent in the laboratory scale experiment and the corresponding countermeasures were also discussed. 展开更多
关键词 palm oil mill effluent MESOPHILIC anaerobic digestion expanded granular sludge bed (EGSB)
下载PDF
Tomato Yield and Quality and Emitter Clogging as Affected by Chlorination Schemes of Drip Irrigation Systems Applying Sewage Effluent 被引量:13
10
作者 LI Jiu-sheng LI Yan-feng ZHANG Hang 《Journal of Integrative Agriculture》 SCIE CAS CSCD 2012年第10期1744-1754,共11页
Chlorination has been recognized as an efficient and economically favorable method for treating clogging in drip emitters caused by biological growth during sewage application. Further important criteria for determini... Chlorination has been recognized as an efficient and economically favorable method for treating clogging in drip emitters caused by biological growth during sewage application. Further important criteria for determining an optimal chlorination scheme are the different responses of crops to the chloride added into the soil through chlorination. During two seasons in 2008 and 2009, field experiments were conducted in a solar-heated greenhouse with drip irrigation systems applying secondary sewage effluent to tomato plants to investigate the influences of chlorine injection intervals and levels on plant growth, yield, fruit quality, and emitter clogging. Injection intervals ranging from 2 to 8 wk and injection concentrations ranging 2-50 mg L-1 of free chlorine residual at the end of the laterals were used. For the 2008 experiments, the yield from the treatments of sewage application with chlorination was 7.5% lower than the yield from the treatment of sewage application without chlorination, while the yields for the treatments with and without chlorination were similar for the 2009 experiments. The statistical tests indicated that neither the chlorine injection intervals and concentrations nor the interactions between the two significantly influenced plant height, leaf area, or tomato yield for both years. The qualities of the fruit in response to chlorination were parameter-dependent. Chlorination did not significantly influence the quality of ascorbic acid, soluble sugar, or soluble acids, but the interaction between the chlorine injection interval and the chlorine concentration significantly influenced the levels of soluble solids. It was also confirmed that chlorination was an effective method for reducing biological clogging. These results suggested that chlorination is safe for a crop that has a moderate sensitivity to chlorine, like tomato, and can maintain a high level of performance in drip irrigation systems applying sewage effluent. 展开更多
关键词 CHLORINATION drip irrigation emitter clogging fruit quality TOMATO sewage effluent YIELD
下载PDF
Enhancing treatment efficiency of swine wastewater by effluent recirculation in vertical-flow constructed wetland 被引量:8
11
作者 HE Lian-sheng LIU Hong-liang +1 位作者 XI Bei-dou ZHU Ying-bo 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2006年第2期221-226,共6页
Livestock wastewater has been a major contributor to Chinese cultural eutrophication of surface waters. Constructed wetlands are under study as a best management practice to treat wastewater from dairy and swine opera... Livestock wastewater has been a major contributor to Chinese cultural eutrophication of surface waters. Constructed wetlands are under study as a best management practice to treat wastewater from dairy and swine operations, but the removal efficiency of pollutants is relatively low. Enhancing the treatment efficiency of livestock wastewater by effluent recirculation was investigated in a pilot-scale vertical-flow constructed wetland. The wetland system was composed of downflow and upflow stages, on which narrow-leaf Phragmites communis and common reed Phragraites Typhia are planted, respectively; each stage has a dimension of 4 m^2 (2 m × 2 m). Wastewater from facultative pond was fed into the system intermittently at a flow rate of 0.4 m^3/d. Recirculation rates of 0, 25%, 50%, 100% and 150% were adopted to evaluate the effect of the recirculation rate on pollutants removal. It shows that with effluent recirculation the average removal efficiencies of NH4-N, biological oxygen demand (BOD5) and suspended solids(SS) obviously increase to 61.7%, 81.3%, and 77.1%, respectively, in comparison with the values of 35.6%, 50.2%, and 49.3% without effluent recirculation. But the improvement of TP removal is slight, only from 42.3% to 48.9%. The variations of NH4-N, dissolved oxygen(DO) and oxidation-reduction potential(ORP) of inflow and outflow reveal that the adoption of effluent recirculation is benefi- cial to the formation of oxide environment in wetland. The exponential relationships with excellent correlation coefficients (R2 〉0.93) are found between the removal rates of NH4-N and BOD5 and the recirculation rates. With recirculation the pH value of the outflow decreases as the alkalinity is consumed by gradually enhanced nitrification process. When recirculation rate is kept constant 100%, the ambient temperature appears to affect NH4-N removal, but does not have significant influence on BOD5 removal. 展开更多
关键词 VERTICAL-FLOW constructed wetland swine wastewater effluent recirculation recirculation rate NITRIFICATION
下载PDF
Treatment and utilization of septic tank effluent using vertical-flow constructed wetlands and vegetable hydroponics 被引量:6
12
作者 CUILi-hua LUOShi-ming 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2003年第1期75-82,共8页
Vertical flow constructed wetlands is a typical ecological sanitation system for sewage treatment. The removal rates for COD, BOD 5, SS, TN, and TP were 60%, 80%, 74%, 49% and 79%, respectively, when septic tank effl... Vertical flow constructed wetlands is a typical ecological sanitation system for sewage treatment. The removal rates for COD, BOD 5, SS, TN, and TP were 60%, 80%, 74%, 49% and 79%, respectively, when septic tank effluent was treated by vertical flow filter. So the concentration of COD and BOD\-5 in the treated effluent could meet the quality standard for irrigation water. After that the treated effluent was used for hydroponic cultivation of water spinach and romaine lettuce, the removal efficiencies of the whole system for COD, BOD\-5, SS, TN and TP were 71 4%, 97 5%, 96 9%, 86 3%, and 87 4%, respectively. And it could meet the integrated wastewater discharge standard for secondary biological treatment plant. It was found that using treated effluent for hydroponic cultivation of vegetables could reduce the nitrate content in vegetables. The removal rates for total bacteria and coliform index by using vertical flow bed system with cinder substrate were 80%—90% and 85%—96%, respectively. 展开更多
关键词 septic tank effluent vertical flow constructed wetlands vegetable hydroponic
下载PDF
Nitrogen removal from sludge dewatering effluent through anaerobic ammonia oxidation process 被引量:5
13
作者 ZHANG Shao-hui ZHENG Ping HUA Yu-mei 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2005年第6期1030-1033,共4页
Anaerobic ammonia oxidation(Anammox) process is a novel and promising wastewater nitrogen removal process. The feasibility of transition of Anammox from denitrification and the performance of lab-scale Anammox biofi... Anaerobic ammonia oxidation(Anammox) process is a novel and promising wastewater nitrogen removal process. The feasibility of transition of Anammox from denitrification and the performance of lab-scale Anammox biofilm reactor were investigated with sludge dewatering effluent. The results showed that Anammox process could be successfully started up after cultivation of denitrification biofilm and using it as inoculum. The transition of Anammox from denitrification was accomplished within 85 d. Anammox process was found suitable to remove ammonia from sludge dewatering effluent. The effluent ammonia concentration was detected to be 23.11 mgN/L at HRT of 28 h when influent ammonia concentration was fed 245 mgN/L, which was less than that for the national discharge standard Ⅱ (25 rngN/L) of China. Volumetric total nitrogen loading rate was up to 584.99 mg TN/(L. d) at HRT of 17 h, while influent concentrations were kept 243.25 mg NH4* -N/L and 288.31 mg NO2^- -N/L. 展开更多
关键词 DENITRIFICATION ANAMMOX sludge dewatering effluent nitrogen removal
下载PDF
Acute effects of chlorpyryphos-ethyl and secondary treated effluents on acetylcholinesterase and butyrylcholinesterase activities in Carcinus maenas 被引量:4
14
作者 Jihene Ghedira Jamel Jebali +3 位作者 Zied Bouraoui Mohamed Banni Lassaad Chouba Hamadi Boussetta 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2009年第10期1467-1472,共6页
The acute effects of commercial formulation of chlorpyrifos-ethyl (Dursban ) and the secondary treated industrial/urban effluent (STIUE) exposure on acetylcholinesterase (ACHE) and butyrylcholinesterase (BuChE... The acute effects of commercial formulation of chlorpyrifos-ethyl (Dursban ) and the secondary treated industrial/urban effluent (STIUE) exposure on acetylcholinesterase (ACHE) and butyrylcholinesterase (BuChE) activities in hepatopancreas and gills of Mediterranean crab Carcinus maenas were investigated. After 2 d of exposure to chlorpyriphos-ethyl, the AChE activity was inhibited in both organs at concentrations of 3.12 and 7.82 μg/L, whereas the BuCHE was inhibited only at higher concentration 7.82 μg/L of commercial preparation Dursban~. The exposure of crabs to Dursban (3.12 μg/L) showed a significant decrement of ACHE activity at 24 and 48 h, whereas the BuChE was inhibited only after 24 h and no inhibition for both enzymes was observed after 72 h. Moreover, a significant repression of AChE activity was observed in both organs of C. maenas exposed to 5% of STIUE. Our experiments indicated that the measurement of AChE activity in gills and hepatopancreas of C. maenas would be useful biomarker of organophosphorous (OP) and of neurotoxic effects of STIUE in Tunisia. 展开更多
关键词 ACETYLCHOLINESTERASE BUTYRYLCHOLINESTERASE ORGANOPHOSPHOROUS Dursban secondary treated industrial/urban effluent Carcinus maenas
下载PDF
Performance of hybrid constructed wetland systems for treating septic tank effluent 被引量:3
15
作者 CUI Li-hua LIU Wen +3 位作者 ZHUXi-zhen MA Mei HUANG Xi-hua XIA Yan-yang 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2006年第4期665-669,共5页
The integrated wetland systems were constructed by combining horizontal-flow and vertical-flow bed, and their purification efficiencies for septic tank effluent were detected when the hydraulic retention time (HRT) ... The integrated wetland systems were constructed by combining horizontal-flow and vertical-flow bed, and their purification efficiencies for septic tank effluent were detected when the hydraulic retention time (HRT) was 1 d, 3 d, 5 d under different seasons. The results showed that the removal efficiencies of the organics, phosphorus were steady in the hybrid systems, but the removal efficiency of total nitrogen was not steady due to high total nitrogen concentration in the septic tank effluent. The average removal rates of COD (chemical oxygen demand) were 89%, 87%, 83%, and 86% in summer, autumn, winter and spring, respectively, and it was up to 88%, 85%, 73%, and 74% for BOD5 (5 d biochemical oxygen demand) removal rate in four seasons. The average removal rates of TP (total phosphorous) could reach up to 97%, 98%, 95%, 98% in four seasons, but the removal rate of TN (total nitrogen) was very low. The results of this study also indicated that the capability of purification was the worst in winter. Cultivating with plants could improve the treated effluent quality fTom the hybrid systems. The results of the operation of the horizontal-flow and vertical-flow cells (hybrid systems) showed that the removal efficiencies of the organics, TP and TN in horizontal-flow and vertical-flow cells were improved significantly with the extension of HRT under the same season. The removal rate of 3 d HRT was obviously higher than that of 1 d HRT, and the removal rate of 5 d HRT was better than that of 3 d HRT, but the removal efficiency was not very obvious with the increment of HRT. Therefore, 3 d HRT might be recommended in the actual operation of the hybrid systems for economic and technical reasons. 展开更多
关键词 constructed wetlands hybrid system horizontal-flow VERTICAL-FLOW removal efficiency septic tank effluent
下载PDF
Removal of phenol by activated carbons prepared from palm oil mill effluent sludge 被引量:3
16
作者 Md. Zahangir ALAM Suleyman A. MUYIBI +1 位作者 Mariatul F. MANSOR Radziah WAHID 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2006年第3期446-452,共7页
The study was attempted to produce activated carbons from palm oil mill effluent (POME) sludge. The adsorption capacity of the activated carbons produced was evaluated in aqueous solution of phenol. Two types of act... The study was attempted to produce activated carbons from palm oil mill effluent (POME) sludge. The adsorption capacity of the activated carbons produced was evaluated in aqueous solution of phenol. Two types of activation were followed, namely, thermal activation at 300, 500 and 800%, and physical activation at 150% (boiling treatment). A control (raw POME sludge) was used to compare the adsorption capacity of the activated carbons produced. The results indicated that the activation temperature of 800℃ showed maximum absorption capacity by the activated carbon (POME 800) in aqueous solution of phenol. Batch adsorption studies showed an equilibrium time of 6 h for the activated carbon of POME 800. It was observed that the adsorption capacity was higher at lower values ofpH (2--3) and higher value of initial concentration of phenol (200--300 mg/L), The equilibrium data were fitted by the Langmuir and Freundlich adsorption isotherms. The adsorption of phenol onto the activated carbon POME 800 was studied in terms of pseudo-first and second order kinetics to predict the rate constant and equilibrium capacity with the effect of initial phenol concentrations. The rate of adsorption was found to be better correlation for the pseudo-second order kinetics compared to the first order kinetics. 展开更多
关键词 activated carbon ADSORPTION palm oil mill effluent (POME) sludge PHENOL
下载PDF
High performance electrocoagulation process in treating palm oil mill effluent using high current intensity application 被引量:2
17
作者 Mohd Nasrullah A.W.Zularisam +3 位作者 Santhana Krishnan Mimi Sakinah Lakhveer Singh Yap Wing Fen 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2019年第1期208-217,共10页
Electrocoagulation process using high current intensity to treat palm oil mill effluent(POME) was investigated in this study.Various operating parameters such as electrolysis time, inter-electrode distance and initial... Electrocoagulation process using high current intensity to treat palm oil mill effluent(POME) was investigated in this study.Various operating parameters such as electrolysis time, inter-electrode distance and initial pH were carried out to determine the efficient process condition on the removal of chemical oxygen demand(COD),biological oxygen demand(BOD) and suspended solids(SS).The highest treatment was achieved at 50 min with the removal efficiencies for COD, BOD and SS obtained as 85%, 83%, and 84%, respectively.More than 50 min treatment showed the fluctuated trends of removal efficiencies which can be considered insignificant.The application of higher current resulted in higher removals of organics while the gas bubbles also assisted in removing the pollutant particles by floatation.In an inter-electrode distance study, the removal efficiency decreased when inter-electrode distance was either higher or lower than 10 mm due to the increase of solution resistance and the decrease of anode active surface area.In initial pH study, it was found that high removal efficiencies were achieved in slightly acidic POME sample rather than in neutral or basic condition.An electrocoagulation process by using the optimum operating parameters was able to remove COD, BOD and SS up to 95%, 94% and 96% respectively.The experimental results confirm that application of high current intensity in electrocoagulation provided high treatment efficiency at a reduced reaction time. 展开更多
关键词 ELECTROCHEMISTRY Environment ELECTROCOAGULATION PALM oil MILL effluent High current INTENSITY
下载PDF
Effects of hydraulic retention time, temperature, and effluent recycling on efficiency of anaerobic filter in treating rural domestic wastewater 被引量:3
18
作者 John Leju Celestino LADU Xi-wu Lü 《Water Science and Engineering》 EI CAS CSCD 2014年第2期168-182,共15页
With rural population expansion and improvement of the socio-economic standard of living, treatment of rural domestic wastewater has rapidly become a major aspect of environmental concern. Selection of a suitable meth... With rural population expansion and improvement of the socio-economic standard of living, treatment of rural domestic wastewater has rapidly become a major aspect of environmental concern. Selection of a suitable method for treatment of rural domestic wastewater depends on its efficiency, simplicity, and cost-effectiveness. This study investigated the effects of hydraulic retention time (HRT), temperature, and effluent recycling on the treatment efficiency of an anaerobic filter (AF) reactor. The first round of experimental operations was run for three months with HRTs of one, two, and three days, temperatures of 18℃, 21℃, and 24℃, and no effluent recycling. The second round of experimental operations was conducted for another three months with HRTs of three and four days; temperatures of 30.67℃, 30.57℃, and 26.91 ℃ ; and three effluent recycling ratios of 1:1, 1:2, and 2:1. The first round of operations showed removal rates of 32% to 44% for COD, 30% to 35% for TN, 32% to 36% for NH4-N, 19% to 23% for NO3-N, and 12% to 22% for TE In the second round of operations, the removal rates varied from 75% to 81% for COD, 35% to 41% for TN, 31% to 39% for NH4-N, 30% to 34% for NO3-N, and 41% to 48% for TP. The average gas production rates were 6.72 L/d and 7.26 L/d for the first and second rounds of operations, respectively. The gas production rate increased in the second round of operations as a result of applied effluent recycling. The best removal efficiency was obtained for an optimum HRT of three days, a temperature of 30℃, and an effluent recycling ratio of 2:1. The results show that the removal efficiency of the AF reactor was affected by HRT, temperature, and effluent recycling. 展开更多
关键词 anaerobic filter (AF) rural domestic wastewater hydraulic retention time (HRT) effluent recycling experimental operation
下载PDF
Effects of Chlorination on Soil Chemical Properties and Nitrogen Uptake for Tomato Drip Irrigated with Secondary Sewage Effluent 被引量:2
19
作者 LI Yan-feng LI Jiu-sheng ZHANG Hang 《Journal of Integrative Agriculture》 SCIE CAS CSCD 2014年第9期2049-2060,共12页
Chlorination is usually an economical method for treating clogging in drip emitters during sewage application. Appropriate assessment of the responses of soil and crop is essential for determining an optimal chlorinat... Chlorination is usually an economical method for treating clogging in drip emitters during sewage application. Appropriate assessment of the responses of soil and crop is essential for determining an optimal chlorination scheme. During 2008 to 2009, field experiments were conducted in a solar-heated greenhouse for tomato drip irrigated with secondary sewage effluent, to investigate the influences of chlorine injection intervals and levels on soil chemical properties and nitrogen uptake. Injection intervals ranging from two to eight weeks and injection concentrations ranging from 2 to 50 mg L-1 were used. A salinity factor and a nutrient factor were extracted from the pool of the nine soil chemical constituents using factor analysis method. The results demonstrated that chlorination practices increased the residual Cl in the soil, resulting in an increased salinity factor, especially for the frequent chlorination at a high injection concentration. Chlorination weakened the accumulation of nutrients factor in the upper soil layer. Nitrogen uptake of the tomato plants also was inhibited by the increased salinity in the upper soil layer caused by high chlorination levels. In order to reduce the unfavorable effect on soil chemical properties and nitrogen uptake, chlorination scheme with concentrations of lower than 20 mg L-1 was recommended. 展开更多
关键词 CHLORINATION drip irrigation soil chemical properties nitrogen uptake sewage effluent
下载PDF
Impacts of Chromium from Tannery Effluent and Evaluation of Alternative Treatment Options 被引量:5
20
作者 Alebel Abebe Belay 《Journal of Environmental Protection》 2010年第1期53-58,共6页
The paper has focused on the challenges/impacts of tannery effluent and evaluates the alternative treatment options used to treat, recover or recycle chromium from the waste water. The paper was done entirely on secon... The paper has focused on the challenges/impacts of tannery effluent and evaluates the alternative treatment options used to treat, recover or recycle chromium from the waste water. The paper was done entirely on secondary data by consulting literature sources including scientific journals, chapters of books, conference report papers and websites. The results of this review paper indicated that chromium is highly toxic and carcinogenic to human beings, animals, plants and the general environment (soil and water sediment). It is found out that chrome is the primary threat when ever tanning industry comes in to practice. Though many treatment options were evaluated to prevent its consequence on the environment, neither of them could achieve to treat or recover chrome 100%. Treatment options are either;inef-ficient, complicated, energy demanding, costly or applicable to a certain parts of the world due to technology or skilled man power demand. Therefore, to tackle this serious challenge stringent environmental regulation with law enforce-ment has to be exercised to use better treatment system which is widely applicable. Polluters must also know the envi-ronmental cost of their industry and treated according to polluter pay or precautionary principles. Moreover, the gen-eral public has to be aware of it and all concerned organizations and governments has to work hand in hand to reach zero discharge level or at least to attain the EPA chrome discharge 展开更多
关键词 CHROMIUM TOXICITY Environmental Impact CHROMIUM Recovery and RECYCLING CHROMIUM Treatment OPTION TANNERY effluent
下载PDF
上一页 1 2 173 下一页 到第
使用帮助 返回顶部