The validity of electric power system simulation or prediction models depends on static load model. Measurement- based approach is the unique method to identify them adequately. The measured power depends on both load...The validity of electric power system simulation or prediction models depends on static load model. Measurement- based approach is the unique method to identify them adequately. The measured power depends on both load reaction to supply voltage alteration and random process of load alteration Basically, there is no any universal method that can single out the inherent static load model from experimental data. The paper offers a proprietary technique which is the particular solution of the task. The technique considers the selection of neighboring measurement pairs with the supply voltage altering significantly be-tween them, the exclusion of selected pairs by load power factor and subsequent selection of the inherent static load model presented as the polynomial load model. The usage of the technique to identify static load model at “Fenster” industrial enterprise (in Borisov city) is presented. The ideas considered in the paper can be used for future development of static load model identification methods with the data obtained during both active experiment and in other operating models of electric power systems.展开更多
Based on the De.Morgan laws and Boolean simplification, a recursive decomposition method is introduced in this paper to identify the main exclusive safe paths and failed paths of a network. The reliability or the reli...Based on the De.Morgan laws and Boolean simplification, a recursive decomposition method is introduced in this paper to identify the main exclusive safe paths and failed paths of a network. The reliability or the reliability bound of a network can be conveniently expressed as the summation of the joint probabilities of these paths. Under the multivariate normal distribution assumption, a conditioned reliability index method is developed to evaluate joint probabilities of various exclusive safe paths and failed paths, and, finally, the seismic reliability or the reliability bound of an electric power system. Examples given in the paper show that the method is very simple and provides accurate results in the seismic reliability analysis.展开更多
This study presents the results of a research into the developing a methodology for assessing the adequacy of advanced electric power systems characterized by the integration of various innovative technologies,which c...This study presents the results of a research into the developing a methodology for assessing the adequacy of advanced electric power systems characterized by the integration of various innovative technologies,which complicates their analysis.The methodology development is aimed at solving two main problems:(1)increase the adequacy of modeling the processes that occur in the electric power system and (2)enhance the computational efficiency of the adequacy assessment methodology.This study proposes a new mathematical model to minimize the power shortage and enhance the adequacy of modeling the processes.The model considers quadratic power transmission losses and network coefficients.The computational efficiency of the adequacy assessment methodology is enhanced using efficient random-number generators to form the calculated states of electric power systems and machine learning methods to assess power shortages and other reliability characteristics in the calculated states.展开更多
In themarine electric power system,the marine generators will be disturbed by the large change of loads or the fault of the power system.The marine generators usually installed power system stabilizers to damp power s...In themarine electric power system,the marine generators will be disturbed by the large change of loads or the fault of the power system.The marine generators usually installed power system stabilizers to damp power system oscillations through the excitation control.This paper proposes a novel method to obtain optimal parameter values for Power System Stabilizer(PSS)to suppress low-frequency oscillations in the marine electric power system.In this paper,a newly developed immune clone selection algorithm was improved from the three aspects of the adaptive incentive degree,vaccination,and adaptive mutation strategies.Firstly,the typical PSS implementation type of leader-lag structure was adopted and the objective function was set in the optimization process.The performance of PSS tuned by improved immune clone selection algorithm was compared with PSS tuned by basic immune clone selection algorithm(ICSA)under various operating conditions and disturbances.Then,an improved immune clone selection algorithm(IICSA)optimization technique was implemented on two test systems for test purposes.Based on the simulations,it is found that an improved immune clone selection algorithm demonstrates superiority over the basic immune clone selection algorithm in getting a smaller number of iterations and fast convergence rates to achieve the optimal parameters of the power system stabilizers.Moreover,the proposed approach improves the stability and dynamic performance under various loads conditions and disturbances of the marine electric power system.展开更多
To avoid drawbacks of classic discrete Fourier transform(DFT)method,modern spectral estimation theory was introduced into harmonics and inter-harmonics analysis in electric power system.Idea of the subspace-based root...To avoid drawbacks of classic discrete Fourier transform(DFT)method,modern spectral estimation theory was introduced into harmonics and inter-harmonics analysis in electric power system.Idea of the subspace-based root-min-norm algorithm was described,but it is susceptive to noises with unstable performance in different SNRs.So the modified root-min-norm algorithm based on cross-spectral estimation was proposed,utilizing cross-correlation matrix and independence of different Gaussian noise series.Lots of simulation experiments were carried out to test performance of the algorithm in different conditions,and its statistical characteristics was presented.Simulation results show that the modified algorithm can efficiently suppress influence of the noises,and has high frequency resolution,high precision and high stability,and it is much superior to the classic DFT method.展开更多
This article describes practical preparation of marine engineers on the full mission simulator complex of the ship's automated electrical power plant. A full mission simulator complex of the ship's automated power m...This article describes practical preparation of marine engineers on the full mission simulator complex of the ship's automated electrical power plant. A full mission simulator complex of the ship's automated power management system meets International Convention STCW (Standards of Training, Certification and Watchkeeping) 78 (with Manila amendments 2010) requirements in part of adequate reproduction of its operational modes corresponding to the actual configuration and layout of the ship's automated power management system with real consumers and typical loads. The simulator is fully consistent with the goals and objectives of the practical training, as well as the goals and objectives of proficiency testing engine department officers on issues of technical maintenance of real ship's equipment (high voltage installations included) and means of automation. The simulator's complex is designed for training and proficiency testing of cadets and students of maritime educational institutions, as well as training and proficiency testing of marine specialists (mechanics and electricians) by watch-keeping and maintenance of modem integrated automated control systems of ship's electric power plant and the individual ship electromechanical systems, including high-voltage systems. A simulator's complex provides adequate reproduction of operational situations on technical side of real ship electric and automation equipment provides training on monitoring, control and management diesel-generator sets in hand, semi-automatic and automatic modes of power station, control and management of electromechanical systems, as well as the set of tasks upon parameterization, visualization and etc. Besides number of combinations of monitoring, control and management tasks, the simulator's complex provides an opportunity to simulate various practical fault conditions. It allows students to focus on the work of automatic control system in emergency situations and to work out correct actions for a watch-keeper on searching, localizing of faults and troubleshooting of equipment.展开更多
In recent times, lithium-ion batteries have been widely used owing to their high energy density, extended cycle lifespan, and minimal self-discharge rate. The design of high-speed rechargeable lithium-ion batteries fa...In recent times, lithium-ion batteries have been widely used owing to their high energy density, extended cycle lifespan, and minimal self-discharge rate. The design of high-speed rechargeable lithium-ion batteries faces a significant challenge owing to the need to increase average electric power during charging. This challenge results from the direct influence of the power level on the rate of chemical reactions occurring in the battery electrodes. In this study, the Taguchi optimization method was used to enhance the average electric power during the charging process of lithium-ion batteries. The Taguchi technique is a statistical strategy that facilitates the systematic and efficient evaluation of numerous experimental variables. The proposed method involved varying seven input factors, including positive electrode thickness, positive electrode material, positive electrode active material volume fraction, negative electrode active material volume fraction, separator thickness, positive current collector thickness, and negative current collector thickness. Three levels were assigned to each control factor to identify the optimal conditions and maximize the average electric power during charging. Moreover, a variance assessment analysis was conducted to validate the results obtained from the Taguchi analysis. The results revealed that the Taguchi method was an eff ective approach for optimizing the average electric power during the charging of lithium-ion batteries. This indicates that the positive electrode material, followed by the separator thickness and the negative electrode active material volume fraction, was key factors significantly infl uencing the average electric power during the charging of lithium-ion batteries response. The identification of optimal conditions resulted in the improved performance of lithium-ion batteries, extending their potential in various applications. Particularly, lithium-ion batteries with average electric power of 16 W and 17 W during charging were designed and simulated in the range of 0-12000 s using COMSOL Multiphysics software. This study efficiently employs the Taguchi optimization technique to develop lithium-ion batteries capable of storing a predetermined average electric power during the charging phase. Therefore, this method enables the battery to achieve complete charging within a specific timeframe tailored to a specificapplication. The implementation of this method can save costs, time, and materials compared with other alternative methods, such as the trial-and-error approach.展开更多
Electric power training is essential for ensuring the safety and reliability of the system.In this study,we introduce a novel Abnormal Action Recognition(AAR)system that utilizes a Lightweight Pose Estimation Network(...Electric power training is essential for ensuring the safety and reliability of the system.In this study,we introduce a novel Abnormal Action Recognition(AAR)system that utilizes a Lightweight Pose Estimation Network(LPEN)to efficiently and effectively detect abnormal fall-down and trespass incidents in electric power training scenarios.The LPEN network,comprising three stages—MobileNet,Initial Stage,and Refinement Stage—is employed to swiftly extract image features,detect human key points,and refine them for accurate analysis.Subsequently,a Pose-aware Action Analysis Module(PAAM)captures the positional coordinates of human skeletal points in each frame.Finally,an Abnormal Action Inference Module(AAIM)evaluates whether abnormal fall-down or unauthorized trespass behavior is occurring.For fall-down recognition,three criteria—falling speed,main angles of skeletal points,and the person’s bounding box—are considered.To identify unauthorized trespass,emphasis is placed on the position of the ankles.Extensive experiments validate the effectiveness and efficiency of the proposed system in ensuring the safety and reliability of electric power training.展开更多
As a matured technique used in many fields,the distributed computer system is still a new management method for the aeronautical electrical power distribution system in our country. In this paper, a novel aircraft ele...As a matured technique used in many fields,the distributed computer system is still a new management method for the aeronautical electrical power distribution system in our country. In this paper, a novel aircraft electrical power distribution system based on the distributed computer system is proposed. The principles, features and structure of the aircraft electrical power distribution system and the distributed computer system named electrical load management system (ELMS) are studied. The ELMS composed of four electrical load management centers (ELMCs) and two power source processors (PSPs) operates in the 1553B buses. Principles of the ELMCs and the PSPs are introduced. With the application of the distributed computer system, the aircraft electrical power distribution system is simple, adaptable and flexible.展开更多
The increasing adoption of gas-fired power plants directly strengthens the coupling between electric power and natural gas systems. Current industrial practice in optimal power flow for electric power systems has not ...The increasing adoption of gas-fired power plants directly strengthens the coupling between electric power and natural gas systems. Current industrial practice in optimal power flow for electric power systems has not taken the security constraints of gas systems into consideration, resulting in an overly-optimistic solution. Meanwhile, the operation of electric power and natural gas systems is coupled over multiple periods because of the ramp rate limits of power generators and the slow dynamical characteristics of gas systems. Based on these motivations, we propose a multi-period integrated natural gas and electric power system probabilistic optimal power flow(M-GEPOPF) model, which includes dynamic gas flow models. To address the uncertainties originating from wind power and load forecasting, a probabilistic optimal power flow(POPF) calculation based on a three-point estimate method(3 PEM) is adopted. Moreover, power-togas(Pt G) units are employed to avoid wind power curtailment and enable flexible bi-directional energy flows between the coupled energy systems. An integrated IEEE RTS 24-bus electric power system and the Belgian 20-node natural gas system are employed as a test case to verify the applicability of the proposed M-GEPOPF model, and to demonstrate the potential economic benefits of Pt G units.展开更多
Aiming at the comparatively laggard level of power plant electrical system automation, this paper analyzes the feasibility,necessity and some key points of the application of integrated automation technology to power ...Aiming at the comparatively laggard level of power plant electrical system automation, this paper analyzes the feasibility,necessity and some key points of the application of integrated automation technology to power plant electrical system. New idea using fieldbus control system technology is presented. This paper also gives the outline and detailed schemes.展开更多
The tracking performance of motor current is an important factor that affects the assistance torque of electric power steering (EPS) system. Bad tracking performance will cause assistant torque delay, and make road ...The tracking performance of motor current is an important factor that affects the assistance torque of electric power steering (EPS) system. Bad tracking performance will cause assistant torque delay, and make road feeling bad, and is influenced by the input steering torque and system measuring noise. However the existing methods have some shortages on system's robust dynamic performance and robust stability. The mixed H2/H∞ strategy for recirculating ball-type EPS system in a pure electric bus is proposed, and vehicle dynamic model of the system is established. Due to the existence of system model uncertainty, disturbance signals, sensor noises and the demand of system dynamic performance, the indexes of robust performance and road feeling for drivers are defined as the appraisal control objectives. The H∞ method is introduced to design the H∞ controller, and the H2 method is applied to optimize the H∞ controller, thus the mixed H2/H∞ controller is designed. The response of EPS system to the motor current command with amplitude of 20 A, the road disturbance with amplitude of 500 N and the sensor random noise with the amplitude of 1 A is simulated. The simulation results show that the recirculating ball-type EPS system with the mixed H2/H∞ controller can attenuate the random noises and disturbances and track the boost curve well, so the mixed H2/H∞ controller can improve the system's robust performance and dynamic performance. For the purpose of verifying the performance of the designed control strategy, the motor current tracking performance ground tests are conducted with step response input of the steering wheel, double-lane steering test and lemniscate steering test, respectively. The tests show that the mixed H2/H∞ controller for the recirculating ball-type EPS system of pure electric bus is feasible. The designed controller can solve the robust performance and robust stability of the system, thus improve the tracking performance of the EPS system and provide satisfied road feeling for the drivers.展开更多
The dynamic model of a novel electric power steering (EPS) system integrated with active front steering function (the novel EPS system) is built. The concepts and quantitative expressions of the steering road feel...The dynamic model of a novel electric power steering (EPS) system integrated with active front steering function (the novel EPS system) is built. The concepts and quantitative expressions of the steering road feel, steering sensibility, and steering operation stability are introduced. Based on quality engineering theory, the optimization algorithm is proposed by integrating the Monte Carlo descriptive sampling, elitist non-dominated sorting genetic algorithm (NSGA-II) and 6-sigma design method. With the steering road feel and the steering portability as optimization targets, the system parameters are optimized by the proposed optimization algorithm. The simulation results show that the system optimized based on quality engineering theory can improve the steering road feel, guarantee steering stability and steering portability and thus provide a theoretical basis for the design and optimization of the novel electric power steering system.展开更多
Pressure ripples in electric power steering (EPS) systems can be caused by the phase lag between the driver s steering torque and steer angle, the nonlinear frictions, and the disturbances from road and sensor noise...Pressure ripples in electric power steering (EPS) systems can be caused by the phase lag between the driver s steering torque and steer angle, the nonlinear frictions, and the disturbances from road and sensor noise especially during high-frequency maneuvers. This paper investigates the use of the robust fuzzy control method for actively reducing pressure ripples for EPS systems. Remarkable progress on steering maneuverability is achieved. The EPS dynamics is described with an eight-order nonlinear state-space model and approximated by a Takagi-Sugeno (T-S) fuzzy model with time-varying delays and external disturbances. A stabilization approach is then presented for nonlinear time-delay systems through fuzzy state feedback controller in parallel distributed compensation (PDC) structure. The closed-loop stability conditions of EPS system with the fuzzy controller are parameterized in terms of the linear matrix inequality (LMI) problem. Simulations and experiments using the proposed robust fuzzy controller and traditional PID controller have been carried out for EPS systems. Both the simulation and experiment results show that the proposed fuzzy controller can reduce the torque ripples and allow us to have a good steering feeling and stable driving.展开更多
As the scale of the power system continues to expand,the environment for power operations becomes more and more complex.Existing risk management and control methods for power operations can only set the same risk dete...As the scale of the power system continues to expand,the environment for power operations becomes more and more complex.Existing risk management and control methods for power operations can only set the same risk detection standard and conduct the risk detection for any scenario indiscriminately.Therefore,more reliable and accurate security control methods are urgently needed.In order to improve the accuracy and reliability of the operation risk management and control method,this paper proposes a method for identifying the key links in the whole process of electric power operation based on the spatiotemporal hybrid convolutional neural network.To provide early warning and control of targeted risks,first,the video stream is framed adaptively according to the pixel changes in the video stream.Then,the optimized MobileNet is used to extract the feature map of the video stream,which contains both time-series and static spatial scene information.The feature maps are combined and non-linearly mapped to realize the identification of dynamic operating scenes.Finally,training samples and test samples are produced by using the whole process image of a power company in Xinjiang as a case study,and the proposed algorithm is compared with the unimproved MobileNet.The experimental results demonstrated that the method proposed in this paper can accurately identify the type and start and end time of each operation link in the whole process of electric power operation,and has good real-time performance.The average accuracy of the algorithm can reach 87.8%,and the frame rate is 61 frames/s,which is of great significance for improving the reliability and accuracy of security control methods.展开更多
The ongoing need for better fuel economy and lower exhaust pollution of vehicles has increased the employment of electric power steering(EPS)in automotives.Optimal design of EPS for a product family reduces the develo...The ongoing need for better fuel economy and lower exhaust pollution of vehicles has increased the employment of electric power steering(EPS)in automotives.Optimal design of EPS for a product family reduces the development and fabrication costs significantly.In this paper,the TOPSIS method along with the NSGA-Ⅱis employed to find an optimum family of EPS for an automotive platform.A multi-objective optimization problem is defined considering road feel,steering portability,RMS of Ackerman error,and product family penalty function(PFPF)as the conflicting objective functions.The results for the single objective optimization problems and the ones for the multi-objective optimization problem,as well as two suggested trade-off design points are presented,compared and discussed.For the two suggested points,performance at one objective function is deteriorated by about 1%,while the commonality is increased by 20%–40%,which shows the effectiveness of the proposed method in first finding the non-dominated design points and then selecting the trade-off among the obtained points.The results indicate that the obtained trade-off points have superior performance within the product family with maximum number of common parts.展开更多
In order to online monitor the running state of variable voltage and variable frequency(VVVF)hydraulic system,this paper presents a graphic monitoring method that fuses the information of variable frequency electric p...In order to online monitor the running state of variable voltage and variable frequency(VVVF)hydraulic system,this paper presents a graphic monitoring method that fuses the information of variable frequency electric parameters.This paper first analyzes how the voltage and current of the motor stator change with the operation conditions of VVVF hydraulic system.As a result,we draw the relationship between the electric parameters(voltage and current)and power frequency.Then,the signals of the voltage and current are fused as dynamic figures based on the idea of Lissajous figures,and the values of the electric parameters are related to the features of the dynamic figures.Rigorous theoretical analysis establishes the function between the electric power of the variable frequency motor(VFM)and the features of the plotted dynamic figures including area of diagram,area of bounding rectangle,tilt angle,etc.Finally,the effectiveness of the proposed method is verified by two cases,in which the speed of VFM and the load of VVVF hydraulic system are changed.The results show that the increase of the speed of VFM enhances its three-phase electric power,but reduces the tilt angle of the plotted dynamic figures.In addition,as the load of VVVF hydraulic system is increased,the three-phase electric power of VFM and the tilt angle of the plotted dynamic figures are both increased.This paper provides a new way to online monitor the running state of VVVF hydraulic system.展开更多
In this paper, the performance of a column-type electric power steering (EPS) system and vehicle has been studied and a detailed mathematical model for the system has been established. Based on the mathematic model ...In this paper, the performance of a column-type electric power steering (EPS) system and vehicle has been studied and a detailed mathematical model for the system has been established. Based on the mathematic model of the optimization design for steering feel, the parameters of the EPS system and vehicle on steering performance have been investigated. Moreover, the effects of the parameters on system stability have been analyzed and compared by the method of absolute sensitivity and the results are given in the end.展开更多
文摘The validity of electric power system simulation or prediction models depends on static load model. Measurement- based approach is the unique method to identify them adequately. The measured power depends on both load reaction to supply voltage alteration and random process of load alteration Basically, there is no any universal method that can single out the inherent static load model from experimental data. The paper offers a proprietary technique which is the particular solution of the task. The technique considers the selection of neighboring measurement pairs with the supply voltage altering significantly be-tween them, the exclusion of selected pairs by load power factor and subsequent selection of the inherent static load model presented as the polynomial load model. The usage of the technique to identify static load model at “Fenster” industrial enterprise (in Borisov city) is presented. The ideas considered in the paper can be used for future development of static load model identification methods with the data obtained during both active experiment and in other operating models of electric power systems.
基金National Outstanding Youth Science Foundation of China Under Grant No.598251005
文摘Based on the De.Morgan laws and Boolean simplification, a recursive decomposition method is introduced in this paper to identify the main exclusive safe paths and failed paths of a network. The reliability or the reliability bound of a network can be conveniently expressed as the summation of the joint probabilities of these paths. Under the multivariate normal distribution assumption, a conditioned reliability index method is developed to evaluate joint probabilities of various exclusive safe paths and failed paths, and, finally, the seismic reliability or the reliability bound of an electric power system. Examples given in the paper show that the method is very simple and provides accurate results in the seismic reliability analysis.
基金the framework of the project under state assignment (No. FWEU-2021-0003) of the RF Basic Research Program for 2021-2030financial support from the Russian Foundation for Basic Research within the framework of the scientific project No 20-08-00550
文摘This study presents the results of a research into the developing a methodology for assessing the adequacy of advanced electric power systems characterized by the integration of various innovative technologies,which complicates their analysis.The methodology development is aimed at solving two main problems:(1)increase the adequacy of modeling the processes that occur in the electric power system and (2)enhance the computational efficiency of the adequacy assessment methodology.This study proposes a new mathematical model to minimize the power shortage and enhance the adequacy of modeling the processes.The model considers quadratic power transmission losses and network coefficients.The computational efficiency of the adequacy assessment methodology is enhanced using efficient random-number generators to form the calculated states of electric power systems and machine learning methods to assess power shortages and other reliability characteristics in the calculated states.
基金This work is supported by Shanghai Science and Technology Planning Project(Project No.20040501200).
文摘In themarine electric power system,the marine generators will be disturbed by the large change of loads or the fault of the power system.The marine generators usually installed power system stabilizers to damp power system oscillations through the excitation control.This paper proposes a novel method to obtain optimal parameter values for Power System Stabilizer(PSS)to suppress low-frequency oscillations in the marine electric power system.In this paper,a newly developed immune clone selection algorithm was improved from the three aspects of the adaptive incentive degree,vaccination,and adaptive mutation strategies.Firstly,the typical PSS implementation type of leader-lag structure was adopted and the objective function was set in the optimization process.The performance of PSS tuned by improved immune clone selection algorithm was compared with PSS tuned by basic immune clone selection algorithm(ICSA)under various operating conditions and disturbances.Then,an improved immune clone selection algorithm(IICSA)optimization technique was implemented on two test systems for test purposes.Based on the simulations,it is found that an improved immune clone selection algorithm demonstrates superiority over the basic immune clone selection algorithm in getting a smaller number of iterations and fast convergence rates to achieve the optimal parameters of the power system stabilizers.Moreover,the proposed approach improves the stability and dynamic performance under various loads conditions and disturbances of the marine electric power system.
基金Shandong University of Science and Technology Research Fund(No.2010KYTD101)
文摘To avoid drawbacks of classic discrete Fourier transform(DFT)method,modern spectral estimation theory was introduced into harmonics and inter-harmonics analysis in electric power system.Idea of the subspace-based root-min-norm algorithm was described,but it is susceptive to noises with unstable performance in different SNRs.So the modified root-min-norm algorithm based on cross-spectral estimation was proposed,utilizing cross-correlation matrix and independence of different Gaussian noise series.Lots of simulation experiments were carried out to test performance of the algorithm in different conditions,and its statistical characteristics was presented.Simulation results show that the modified algorithm can efficiently suppress influence of the noises,and has high frequency resolution,high precision and high stability,and it is much superior to the classic DFT method.
文摘This article describes practical preparation of marine engineers on the full mission simulator complex of the ship's automated electrical power plant. A full mission simulator complex of the ship's automated power management system meets International Convention STCW (Standards of Training, Certification and Watchkeeping) 78 (with Manila amendments 2010) requirements in part of adequate reproduction of its operational modes corresponding to the actual configuration and layout of the ship's automated power management system with real consumers and typical loads. The simulator is fully consistent with the goals and objectives of the practical training, as well as the goals and objectives of proficiency testing engine department officers on issues of technical maintenance of real ship's equipment (high voltage installations included) and means of automation. The simulator's complex is designed for training and proficiency testing of cadets and students of maritime educational institutions, as well as training and proficiency testing of marine specialists (mechanics and electricians) by watch-keeping and maintenance of modem integrated automated control systems of ship's electric power plant and the individual ship electromechanical systems, including high-voltage systems. A simulator's complex provides adequate reproduction of operational situations on technical side of real ship electric and automation equipment provides training on monitoring, control and management diesel-generator sets in hand, semi-automatic and automatic modes of power station, control and management of electromechanical systems, as well as the set of tasks upon parameterization, visualization and etc. Besides number of combinations of monitoring, control and management tasks, the simulator's complex provides an opportunity to simulate various practical fault conditions. It allows students to focus on the work of automatic control system in emergency situations and to work out correct actions for a watch-keeper on searching, localizing of faults and troubleshooting of equipment.
文摘In recent times, lithium-ion batteries have been widely used owing to their high energy density, extended cycle lifespan, and minimal self-discharge rate. The design of high-speed rechargeable lithium-ion batteries faces a significant challenge owing to the need to increase average electric power during charging. This challenge results from the direct influence of the power level on the rate of chemical reactions occurring in the battery electrodes. In this study, the Taguchi optimization method was used to enhance the average electric power during the charging process of lithium-ion batteries. The Taguchi technique is a statistical strategy that facilitates the systematic and efficient evaluation of numerous experimental variables. The proposed method involved varying seven input factors, including positive electrode thickness, positive electrode material, positive electrode active material volume fraction, negative electrode active material volume fraction, separator thickness, positive current collector thickness, and negative current collector thickness. Three levels were assigned to each control factor to identify the optimal conditions and maximize the average electric power during charging. Moreover, a variance assessment analysis was conducted to validate the results obtained from the Taguchi analysis. The results revealed that the Taguchi method was an eff ective approach for optimizing the average electric power during the charging of lithium-ion batteries. This indicates that the positive electrode material, followed by the separator thickness and the negative electrode active material volume fraction, was key factors significantly infl uencing the average electric power during the charging of lithium-ion batteries response. The identification of optimal conditions resulted in the improved performance of lithium-ion batteries, extending their potential in various applications. Particularly, lithium-ion batteries with average electric power of 16 W and 17 W during charging were designed and simulated in the range of 0-12000 s using COMSOL Multiphysics software. This study efficiently employs the Taguchi optimization technique to develop lithium-ion batteries capable of storing a predetermined average electric power during the charging phase. Therefore, this method enables the battery to achieve complete charging within a specific timeframe tailored to a specificapplication. The implementation of this method can save costs, time, and materials compared with other alternative methods, such as the trial-and-error approach.
基金supportted by Natural Science Foundation of Jiangsu Province(No.BK20230696).
文摘Electric power training is essential for ensuring the safety and reliability of the system.In this study,we introduce a novel Abnormal Action Recognition(AAR)system that utilizes a Lightweight Pose Estimation Network(LPEN)to efficiently and effectively detect abnormal fall-down and trespass incidents in electric power training scenarios.The LPEN network,comprising three stages—MobileNet,Initial Stage,and Refinement Stage—is employed to swiftly extract image features,detect human key points,and refine them for accurate analysis.Subsequently,a Pose-aware Action Analysis Module(PAAM)captures the positional coordinates of human skeletal points in each frame.Finally,an Abnormal Action Inference Module(AAIM)evaluates whether abnormal fall-down or unauthorized trespass behavior is occurring.For fall-down recognition,three criteria—falling speed,main angles of skeletal points,and the person’s bounding box—are considered.To identify unauthorized trespass,emphasis is placed on the position of the ankles.Extensive experiments validate the effectiveness and efficiency of the proposed system in ensuring the safety and reliability of electric power training.
文摘As a matured technique used in many fields,the distributed computer system is still a new management method for the aeronautical electrical power distribution system in our country. In this paper, a novel aircraft electrical power distribution system based on the distributed computer system is proposed. The principles, features and structure of the aircraft electrical power distribution system and the distributed computer system named electrical load management system (ELMS) are studied. The ELMS composed of four electrical load management centers (ELMCs) and two power source processors (PSPs) operates in the 1553B buses. Principles of the ELMCs and the PSPs are introduced. With the application of the distributed computer system, the aircraft electrical power distribution system is simple, adaptable and flexible.
基金supported by the National Natural Science Foundation of China(No.51277052,No.51407125)
文摘The increasing adoption of gas-fired power plants directly strengthens the coupling between electric power and natural gas systems. Current industrial practice in optimal power flow for electric power systems has not taken the security constraints of gas systems into consideration, resulting in an overly-optimistic solution. Meanwhile, the operation of electric power and natural gas systems is coupled over multiple periods because of the ramp rate limits of power generators and the slow dynamical characteristics of gas systems. Based on these motivations, we propose a multi-period integrated natural gas and electric power system probabilistic optimal power flow(M-GEPOPF) model, which includes dynamic gas flow models. To address the uncertainties originating from wind power and load forecasting, a probabilistic optimal power flow(POPF) calculation based on a three-point estimate method(3 PEM) is adopted. Moreover, power-togas(Pt G) units are employed to avoid wind power curtailment and enable flexible bi-directional energy flows between the coupled energy systems. An integrated IEEE RTS 24-bus electric power system and the Belgian 20-node natural gas system are employed as a test case to verify the applicability of the proposed M-GEPOPF model, and to demonstrate the potential economic benefits of Pt G units.
文摘Aiming at the comparatively laggard level of power plant electrical system automation, this paper analyzes the feasibility,necessity and some key points of the application of integrated automation technology to power plant electrical system. New idea using fieldbus control system technology is presented. This paper also gives the outline and detailed schemes.
基金supported by National Natural Science Foundation of China (Grant No. 51005115, No. 51005248)Science Fund of State Key Laboratory of Automotive Safety and Energy of China (Grant No. KF11201)
文摘The tracking performance of motor current is an important factor that affects the assistance torque of electric power steering (EPS) system. Bad tracking performance will cause assistant torque delay, and make road feeling bad, and is influenced by the input steering torque and system measuring noise. However the existing methods have some shortages on system's robust dynamic performance and robust stability. The mixed H2/H∞ strategy for recirculating ball-type EPS system in a pure electric bus is proposed, and vehicle dynamic model of the system is established. Due to the existence of system model uncertainty, disturbance signals, sensor noises and the demand of system dynamic performance, the indexes of robust performance and road feeling for drivers are defined as the appraisal control objectives. The H∞ method is introduced to design the H∞ controller, and the H2 method is applied to optimize the H∞ controller, thus the mixed H2/H∞ controller is designed. The response of EPS system to the motor current command with amplitude of 20 A, the road disturbance with amplitude of 500 N and the sensor random noise with the amplitude of 1 A is simulated. The simulation results show that the recirculating ball-type EPS system with the mixed H2/H∞ controller can attenuate the random noises and disturbances and track the boost curve well, so the mixed H2/H∞ controller can improve the system's robust performance and dynamic performance. For the purpose of verifying the performance of the designed control strategy, the motor current tracking performance ground tests are conducted with step response input of the steering wheel, double-lane steering test and lemniscate steering test, respectively. The tests show that the mixed H2/H∞ controller for the recirculating ball-type EPS system of pure electric bus is feasible. The designed controller can solve the robust performance and robust stability of the system, thus improve the tracking performance of the EPS system and provide satisfied road feeling for the drivers.
基金Projects(51005115,51205191)supported by the National Natural Science Foundation of ChinaProject(QC201101)supported by the Visiting Scholar Foundation of the Automobile Engineering Key Laboratory of Jiangsu Province,China+1 种基金Project(SKLMT-KFKT-201105)supported by the Visiting Scholar Foundation of the State Key Laboratory of Mechanical Transmission in Chongqing University,ChinaProjects(NS2013015,NS2012086)supported by the Funds from the Postgraduate Creative Base in Nanjing University of Areonautics and Astronautics,and NUAA Research Funding,China
文摘The dynamic model of a novel electric power steering (EPS) system integrated with active front steering function (the novel EPS system) is built. The concepts and quantitative expressions of the steering road feel, steering sensibility, and steering operation stability are introduced. Based on quality engineering theory, the optimization algorithm is proposed by integrating the Monte Carlo descriptive sampling, elitist non-dominated sorting genetic algorithm (NSGA-II) and 6-sigma design method. With the steering road feel and the steering portability as optimization targets, the system parameters are optimized by the proposed optimization algorithm. The simulation results show that the system optimized based on quality engineering theory can improve the steering road feel, guarantee steering stability and steering portability and thus provide a theoretical basis for the design and optimization of the novel electric power steering system.
基金supported Foundation of National Development and Reform Commission of China (No. 2040)
文摘Pressure ripples in electric power steering (EPS) systems can be caused by the phase lag between the driver s steering torque and steer angle, the nonlinear frictions, and the disturbances from road and sensor noise especially during high-frequency maneuvers. This paper investigates the use of the robust fuzzy control method for actively reducing pressure ripples for EPS systems. Remarkable progress on steering maneuverability is achieved. The EPS dynamics is described with an eight-order nonlinear state-space model and approximated by a Takagi-Sugeno (T-S) fuzzy model with time-varying delays and external disturbances. A stabilization approach is then presented for nonlinear time-delay systems through fuzzy state feedback controller in parallel distributed compensation (PDC) structure. The closed-loop stability conditions of EPS system with the fuzzy controller are parameterized in terms of the linear matrix inequality (LMI) problem. Simulations and experiments using the proposed robust fuzzy controller and traditional PID controller have been carried out for EPS systems. Both the simulation and experiment results show that the proposed fuzzy controller can reduce the torque ripples and allow us to have a good steering feeling and stable driving.
基金This paper is supported by the Science and technology projects of Yunnan Province(Grant No.202202AD080004).
文摘As the scale of the power system continues to expand,the environment for power operations becomes more and more complex.Existing risk management and control methods for power operations can only set the same risk detection standard and conduct the risk detection for any scenario indiscriminately.Therefore,more reliable and accurate security control methods are urgently needed.In order to improve the accuracy and reliability of the operation risk management and control method,this paper proposes a method for identifying the key links in the whole process of electric power operation based on the spatiotemporal hybrid convolutional neural network.To provide early warning and control of targeted risks,first,the video stream is framed adaptively according to the pixel changes in the video stream.Then,the optimized MobileNet is used to extract the feature map of the video stream,which contains both time-series and static spatial scene information.The feature maps are combined and non-linearly mapped to realize the identification of dynamic operating scenes.Finally,training samples and test samples are produced by using the whole process image of a power company in Xinjiang as a case study,and the proposed algorithm is compared with the unimproved MobileNet.The experimental results demonstrated that the method proposed in this paper can accurately identify the type and start and end time of each operation link in the whole process of electric power operation,and has good real-time performance.The average accuracy of the algorithm can reach 87.8%,and the frame rate is 61 frames/s,which is of great significance for improving the reliability and accuracy of security control methods.
文摘The ongoing need for better fuel economy and lower exhaust pollution of vehicles has increased the employment of electric power steering(EPS)in automotives.Optimal design of EPS for a product family reduces the development and fabrication costs significantly.In this paper,the TOPSIS method along with the NSGA-Ⅱis employed to find an optimum family of EPS for an automotive platform.A multi-objective optimization problem is defined considering road feel,steering portability,RMS of Ackerman error,and product family penalty function(PFPF)as the conflicting objective functions.The results for the single objective optimization problems and the ones for the multi-objective optimization problem,as well as two suggested trade-off design points are presented,compared and discussed.For the two suggested points,performance at one objective function is deteriorated by about 1%,while the commonality is increased by 20%–40%,which shows the effectiveness of the proposed method in first finding the non-dominated design points and then selecting the trade-off among the obtained points.The results indicate that the obtained trade-off points have superior performance within the product family with maximum number of common parts.
基金National Natural Science Foundation of China(No.51675399)
文摘In order to online monitor the running state of variable voltage and variable frequency(VVVF)hydraulic system,this paper presents a graphic monitoring method that fuses the information of variable frequency electric parameters.This paper first analyzes how the voltage and current of the motor stator change with the operation conditions of VVVF hydraulic system.As a result,we draw the relationship between the electric parameters(voltage and current)and power frequency.Then,the signals of the voltage and current are fused as dynamic figures based on the idea of Lissajous figures,and the values of the electric parameters are related to the features of the dynamic figures.Rigorous theoretical analysis establishes the function between the electric power of the variable frequency motor(VFM)and the features of the plotted dynamic figures including area of diagram,area of bounding rectangle,tilt angle,etc.Finally,the effectiveness of the proposed method is verified by two cases,in which the speed of VFM and the load of VVVF hydraulic system are changed.The results show that the increase of the speed of VFM enhances its three-phase electric power,but reduces the tilt angle of the plotted dynamic figures.In addition,as the load of VVVF hydraulic system is increased,the three-phase electric power of VFM and the tilt angle of the plotted dynamic figures are both increased.This paper provides a new way to online monitor the running state of VVVF hydraulic system.
基金Project supported by the National Natural Science Foundation of China (Grant No.60674067)the Scientific and Techno-logical Foundation of Hubei Province (Grant No.2006AA101B13)
文摘In this paper, the performance of a column-type electric power steering (EPS) system and vehicle has been studied and a detailed mathematical model for the system has been established. Based on the mathematic model of the optimization design for steering feel, the parameters of the EPS system and vehicle on steering performance have been investigated. Moreover, the effects of the parameters on system stability have been analyzed and compared by the method of absolute sensitivity and the results are given in the end.