期刊文献+
共找到4篇文章
< 1 >
每页显示 20 50 100
Real-time localization for underwater equipment using an extremely low frequency electric field 被引量:1
1
作者 Jia-wei Zhang Peng Yu +1 位作者 Run-xiang Jiang Tao-tao Xie 《Defence Technology(防务技术)》 SCIE EI CAS CSCD 2023年第8期203-212,共10页
A new real-time underwater equipment location method adopting an electric field induced by a standard current source is proposed.Our goals were real-time tracking and location of stationary or moving underwater equipm... A new real-time underwater equipment location method adopting an electric field induced by a standard current source is proposed.Our goals were real-time tracking and location of stationary or moving underwater equipment both in shallow and deep seas,under noisy conditions.The main features of this method are as follows:(1)a standard current source on the water surface,which can be towed by a vehicle,consisting of two electrodes,a signal generator,and a GPS unit;(2)measurement of the extremely low frequency(ELF)electric field emitted by the current source,made possible by electric field sensors on the underwater equipment;(3)position of the underwater equipment is estimated in real time based on a progressive update extended Kalman filter(PUEKF),which is carried out using the propagation model of an ELF electric field because the electric field at the position of the underwater equipment and the current source position are known.We verified the accuracy of our method and confirmed real-time location feasibility through numerical,physical scale,and real-time sea experiments.Through numerical experiments,we verified that our method works for underwater equipment location in real-world conditions,and the location error can be less than 0.2 m.Next,real-time location experiments for stationary underwater measuring equipment in water tank were conducted.The result shows that the location error can be less than 0.1 m.We also confirmed real-time location feasibility through the use of offshore experiment.We expect that our method will complement conventional underwater acoustic location methods for underwater equipment in acoustically noisy environments. 展开更多
关键词 Termsd Real-time tracking and location method Underwater equipment location ELF electric field Shallow sea Physical scale experiment Sea experiment
下载PDF
Study on Missile Intelligent Fault Diagnosis System Based on Fuzzy NN Expert System 被引量:7
2
作者 Yang Jun Feng Zhensheng +1 位作者 Zhang Xien & Liu Pengyuan Dept. of Missile Engineering, Ordnance Engineering College, Shijiazhuang 050003, P. R. China 《Journal of Systems Engineering and Electronics》 SCIE EI CSCD 2001年第1期82-87,共6页
In order to study intelligent fault diagnosis methods based on fuzzy neural network (NN) expert system and build up intelligent fault diagnosis for a type of missile weapon system, the concrete implementation of a fuz... In order to study intelligent fault diagnosis methods based on fuzzy neural network (NN) expert system and build up intelligent fault diagnosis for a type of missile weapon system, the concrete implementation of a fuzzy NN fault diagnosis expert system is given in this paper. Based on thorough research of knowledge presentation, the intelligent fault diagnosis system is implemented with artificial intelligence for a large-scale missile weapon equipment. The method is an effective way to perform fuzzy fault diagnosis. Moreover, it provides a new way of the fault diagnosis for large-scale missile weapon equipment. 展开更多
关键词 Artificial intelligence Electric fault location Expert systems Fuzzy sets Missiles Neural networks
下载PDF
Serial Failure Diagnosis of a Transmission Line Protection Relaying System by Petri Nets
3
作者 Zhang Zhiming Wang Yue +1 位作者 Tao Ran &Zhou Siyong Dept. of Electronics Engineering, Beijing Institute of Technology, 100081, P. R. China 《Journal of Systems Engineering and Electronics》 SCIE EI CSCD 2001年第1期59-64,共6页
With the development of large-scale complicated modern power systems, the requirement for the associated protection scheme tends to be more stringent and its combination more complex. However, it is very difficult to ... With the development of large-scale complicated modern power systems, the requirement for the associated protection scheme tends to be more stringent and its combination more complex. However, it is very difficult to figure out the factors of failure of such systems. This paper proposes a Petri net model of a transmission line protection relaying system, including three types of relays as well as an automatic reclosing device, and shows how to diagnose serial failure of the system by analyzing invariant sets of the model. Furthermore, it gives four basic types of failure sequences and its execution is much more intuitive and effective than the traditional method. 展开更多
关键词 Electric fault location Electric power system protection Electric relays Failure analysis Mathematical models Petri nets Relay protection
下载PDF
Analysis of the Initial Stage Intracloud Lightning Using the Pulse Location Technique Based on the Fast Electric Field Change
4
作者 王东方 郄秀书 +4 位作者 袁铁 张广庶 张彤 张廷龙 张其林 《Acta meteorologica Sinica》 SCIE 2009年第6期772-781,共10页
Academy of Sciences,Beijing 100029 2 Lanzhou University,Lanzhou 730000 3 Cold and Arid Regions Environmental and Engineering Research Institute, Chinese Academy of Sciences,Lanzhou 730000 4 Nanjing University of Infor... Academy of Sciences,Beijing 100029 2 Lanzhou University,Lanzhou 730000 3 Cold and Arid Regions Environmental and Engineering Research Institute, Chinese Academy of Sciences,Lanzhou 730000 4 Nanjing University of Information Science&Technology,Nanjing 210044 Using both fast and slow electric field change sensors and field mill,multi-station observations on lightning flashes over China inland plateau areas were conducted during the summer of 2004.All of the stations were synchronized by GPS with a time-resolution of±50 ns.Using the different time of arrival(DTOA)and based on the fast electric field change sensor,a lightning radiation location technique was developed.Radiation pulses in the initial stages of five intracloud(IC)lightning discharges which occurred on 20 August were analyzed.The results indicate that the technique developed could effectively locate the lightning radiation sources.Furthermore,the lightning discharges were compared with the Doppler radar data.The results show that the radiation sources were well associated with the storm development.When the storm was at the mature stage with an echo top of about 10.9 km,the radiation sources ranged from 5.2 to 8.3 km above mean sea level;when the storm gradually became weaker,with echo top of about 7.9 km,the radiation sources ranged from 3.0 to 5.9 km.In particular,one of the IC lightning discharges ranged from 3.0 to 4.9 km during the dissipation stage of the storm.The results also indicate that the radiation sources were closely associated with the high reflectivity region(25–50 dBZ)of the storm,which,to some extent,demonstrates the reliability of the location results,thereby showing that multi-station observations of fast electric field change sensors could be a useful tool for monitoring the storm development.Location errors from radiation sources were also compared with the radar data and the results of a simple simulation.It was found that the errors were getting smaller when the radiation sources approached the center of the detection network, and vice versa.Compared with the limited experimental observations,the simulation results were found capable of effectively reflecting the location errors. 展开更多
关键词 thunderstorm intracloud lightning fast electric field change radiation source 3-D location Doppler radar
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部