A generalized mathematical model of human body current threshold for perception was established and the current flowing through human body could be arbitrary cyclical waveforms.The relationship between human body curr...A generalized mathematical model of human body current threshold for perception was established and the current flowing through human body could be arbitrary cyclical waveforms.The relationship between human body current threshold for perception and current frequency, true root mean square(RMS) value and influence factor was described.A test system was established based on electroencephalogram(EEG) to study the relationship between human body current threshold for perception and current waveform, frequency ...展开更多
A forum, the IEC/ACOS Workshop Ⅷ-IEC safety standards in support of regulatory requirements, was held on May 22nd-23rd 2006 in Beijing to cerate an environment for technical exchange between the regulators and th... A forum, the IEC/ACOS Workshop Ⅷ-IEC safety standards in support of regulatory requirements, was held on May 22nd-23rd 2006 in Beijing to cerate an environment for technical exchange between the regulators and the standard developers with its theme on the following regards :……展开更多
I am working in Japan electrical safety & environment technology laboratory,which is called JET for short. In JET, we are carrying out the safety test of electrical equipmentaccording to Japanese domestic stan...I am working in Japan electrical safety & environment technology laboratory,which is called JET for short. In JET, we are carrying out the safety test of electrical equipmentaccording to Japanese domestic standards or IEC standards. And in my section, our stuff is draftingsome national safety standards harmonized with IEC in cooperation with the government. The standardsare applied for the mandatory regulation and other schemes.展开更多
Based on the analysis of weakness on the safety of traditional electric detonators, a BJ-l safety electric detonator initiatingsystem and its corresponding safe examination technique were successfully developed. By le...Based on the analysis of weakness on the safety of traditional electric detonators, a BJ-l safety electric detonator initiatingsystem and its corresponding safe examination technique were successfully developed. By leading false foot wires and taking advantageof the transmitting frequency band of Mo-Zn ferrite, detonators in this new system can completely impede the direct induction of outsidecrosstalk that may cause casual firing in the ordinary as well as eleclromagnetic ones. Possible causality by lightning was discussed. Results are presented, of its safety tests on resistance to direct and alternating current, electrostatic, and crosstalk induced by damp leakagein saturated salty water.展开更多
基金Supported by the Ministry of Science and Technology of China (No. NCSTE-2006-JKZX-167)Beijing Key Laboratory (Measurement and Control of Electro-mechanical Systems) (No. 82063005)
文摘A generalized mathematical model of human body current threshold for perception was established and the current flowing through human body could be arbitrary cyclical waveforms.The relationship between human body current threshold for perception and current frequency, true root mean square(RMS) value and influence factor was described.A test system was established based on electroencephalogram(EEG) to study the relationship between human body current threshold for perception and current waveform, frequency ...
文摘 A forum, the IEC/ACOS Workshop Ⅷ-IEC safety standards in support of regulatory requirements, was held on May 22nd-23rd 2006 in Beijing to cerate an environment for technical exchange between the regulators and the standard developers with its theme on the following regards :……
文摘I am working in Japan electrical safety & environment technology laboratory,which is called JET for short. In JET, we are carrying out the safety test of electrical equipmentaccording to Japanese domestic standards or IEC standards. And in my section, our stuff is draftingsome national safety standards harmonized with IEC in cooperation with the government. The standardsare applied for the mandatory regulation and other schemes.
文摘Based on the analysis of weakness on the safety of traditional electric detonators, a BJ-l safety electric detonator initiatingsystem and its corresponding safe examination technique were successfully developed. By leading false foot wires and taking advantageof the transmitting frequency band of Mo-Zn ferrite, detonators in this new system can completely impede the direct induction of outsidecrosstalk that may cause casual firing in the ordinary as well as eleclromagnetic ones. Possible causality by lightning was discussed. Results are presented, of its safety tests on resistance to direct and alternating current, electrostatic, and crosstalk induced by damp leakagein saturated salty water.