Water supply capability has been significantly reduced as water demand has been increased due to changes of the world's weather, causing the increase of drought frequency, and urbanization. In terms of water produ...Water supply capability has been significantly reduced as water demand has been increased due to changes of the world's weather, causing the increase of drought frequency, and urbanization. In terms of water production, water can be secured by construction a dam or procuring substitute water. However, the study approaches in terms of management of water supply area to control the existing water efficiently. Therefore, water demand was estimated by buildings, by which water load of micro water supply area was calculated. As a result, the deviation of water demand for 1,357 micro water supply areas could be calculated while the alternatives to dissolve the spatial demand unbalance were suggested by two types. From the study, firstly, we could anticipate the total water supply demand from the total sum by filtration plants but it was not possible to anticipate the characteristics of distribution within urban areas. For this, the study attempted to anticipate the demand of each 250 thousands of buildings, comprehending the demand of micro areas. Secondly, based on the built results, we suggest the directions to dissolve the water demand unbalance between and among regions, which could be the foundation to suggest the concrete methodology in the future.展开更多
The redundancy technology for the aircraft multi-channel DC electrical power supply system is studied. In this system, the key loads can obtain power from seven sources. The direct current bus power control unit (DC ...The redundancy technology for the aircraft multi-channel DC electrical power supply system is studied. In this system, the key loads can obtain power from seven sources. The direct current bus power control unit (DC BPCU) is put forward to manage the power supply system automatically. The redundancy innovation is also applied in both hardware and software of DC BPCU. Furthermore, redundancy fault diagnosis is discussed through the existing parts. Experiments and applications show that the proposed aircraft DC power supply system possesses many advantages of high reliability, high automation and so on.展开更多
A power management unit (PMU) chip supplying dual panel supply voltage, which has a low electro-magnetic interference (EMI) characteristic and is favorable for miniaturization, is designed. A two-phase charge pump...A power management unit (PMU) chip supplying dual panel supply voltage, which has a low electro-magnetic interference (EMI) characteristic and is favorable for miniaturization, is designed. A two-phase charge pump circuit using external pumping capacitor increases its pumping current and works out the charge-loss problem by using bulk-potential biasing circuit. A low-power start-up circuit is also proposed to reduce the power consumption of the band-gap reference voltage generator. And the ring oscillator used in the ELVSS power circuit is designed with logic devices by supplying the logic power supply to reduce the layout area. The PMU chip is designed with MagnaChip's 0.25 μ high-voltage process. The driving currents of ELVDD and ELVSS are more than 50 mA when a SPICE simulation is done.展开更多
This paper is concerned with the development of electronic controller for turbine POwer units. In order to increase the reliability of the POwer unit, three control loops working in the hi-backup mode have been employ...This paper is concerned with the development of electronic controller for turbine POwer units. In order to increase the reliability of the POwer unit, three control loops working in the hi-backup mode have been employed. This control strategy is able to satisfy the demands of the application of the power unit to the aviation fields.展开更多
Considering sharp increase of central integration scale of intermittent energy generation, power system couldn’t rely on the determined model based operation schedule to assure its reliable load supply. Then, this ar...Considering sharp increase of central integration scale of intermittent energy generation, power system couldn’t rely on the determined model based operation schedule to assure its reliable load supply. Then, this article presents a new load supply adequacy evaluation method, which based on continuous security constrained generation optimization, and provides the functional architecture design of online multi-level short term load supply adequacy evaluation system.展开更多
The supply of rare earths outside China was 19,800 tons in 2017, an increase of 16% over 2016. the supply of rare earths outside China was 42,200 tons in 2018, a 210% increase continuous discovery of rare earth resour...The supply of rare earths outside China was 19,800 tons in 2017, an increase of 16% over 2016. the supply of rare earths outside China was 42,200 tons in 2018, a 210% increase continuous discovery of rare earth resources in the globe, China’s share of rare earth reserves has gradually declined. Since 2017, the continuous improvement of operating rate of Lynas in Australia and the re-exploitation of the Mountain Pass mine in the United States resulted in the formation of a diversified supply pattern of rare earth products.展开更多
文摘Water supply capability has been significantly reduced as water demand has been increased due to changes of the world's weather, causing the increase of drought frequency, and urbanization. In terms of water production, water can be secured by construction a dam or procuring substitute water. However, the study approaches in terms of management of water supply area to control the existing water efficiently. Therefore, water demand was estimated by buildings, by which water load of micro water supply area was calculated. As a result, the deviation of water demand for 1,357 micro water supply areas could be calculated while the alternatives to dissolve the spatial demand unbalance were suggested by two types. From the study, firstly, we could anticipate the total water supply demand from the total sum by filtration plants but it was not possible to anticipate the characteristics of distribution within urban areas. For this, the study attempted to anticipate the demand of each 250 thousands of buildings, comprehending the demand of micro areas. Secondly, based on the built results, we suggest the directions to dissolve the water demand unbalance between and among regions, which could be the foundation to suggest the concrete methodology in the future.
文摘The redundancy technology for the aircraft multi-channel DC electrical power supply system is studied. In this system, the key loads can obtain power from seven sources. The direct current bus power control unit (DC BPCU) is put forward to manage the power supply system automatically. The redundancy innovation is also applied in both hardware and software of DC BPCU. Furthermore, redundancy fault diagnosis is discussed through the existing parts. Experiments and applications show that the proposed aircraft DC power supply system possesses many advantages of high reliability, high automation and so on.
文摘A power management unit (PMU) chip supplying dual panel supply voltage, which has a low electro-magnetic interference (EMI) characteristic and is favorable for miniaturization, is designed. A two-phase charge pump circuit using external pumping capacitor increases its pumping current and works out the charge-loss problem by using bulk-potential biasing circuit. A low-power start-up circuit is also proposed to reduce the power consumption of the band-gap reference voltage generator. And the ring oscillator used in the ELVSS power circuit is designed with logic devices by supplying the logic power supply to reduce the layout area. The PMU chip is designed with MagnaChip's 0.25 μ high-voltage process. The driving currents of ELVDD and ELVSS are more than 50 mA when a SPICE simulation is done.
文摘This paper is concerned with the development of electronic controller for turbine POwer units. In order to increase the reliability of the POwer unit, three control loops working in the hi-backup mode have been employed. This control strategy is able to satisfy the demands of the application of the power unit to the aviation fields.
文摘Considering sharp increase of central integration scale of intermittent energy generation, power system couldn’t rely on the determined model based operation schedule to assure its reliable load supply. Then, this article presents a new load supply adequacy evaluation method, which based on continuous security constrained generation optimization, and provides the functional architecture design of online multi-level short term load supply adequacy evaluation system.
文摘The supply of rare earths outside China was 19,800 tons in 2017, an increase of 16% over 2016. the supply of rare earths outside China was 42,200 tons in 2018, a 210% increase continuous discovery of rare earth resources in the globe, China’s share of rare earth reserves has gradually declined. Since 2017, the continuous improvement of operating rate of Lynas in Australia and the re-exploitation of the Mountain Pass mine in the United States resulted in the formation of a diversified supply pattern of rare earth products.