Discussion on several important problems in earthquake-related electromagnetic disturbance monitoring in China
1
作者 Lanwei Wang Shizhong Zhang Yu Zhang Dapeng Liu 《Earthquake Science》 CSCD 2011年第6期583-591,共9页
Earthquake-related electromagnetic observation aims at finding abnormal electromagnetic variation associated with earthquake possibly. The existing studies have proved that this method is, to a large extent, effective... Earthquake-related electromagnetic observation aims at finding abnormal electromagnetic variation associated with earthquake possibly. The existing studies have proved that this method is, to a large extent, effective in short-term and impending earthquake predication. This paper summarizes progress and discusses some related problems in this field. Some requirements for observation system have been proposed to improve monitoring level. As a case observation using the reformed observation system in Jinghai seismologie station, Tianjin, some results are given. 展开更多
关键词 earthquake-related electromagnetic disturbance geo-electric field magnetic field elec-tromagnetic disturbance event
下载PDF
Repetitive transcranial magnetic stimulation improves consciousness disturbance in stroke patients A quantitative electroencephalography spectral power analysis 被引量:2
2
作者 Ying Xie Tong Zhang 《Neural Regeneration Research》 SCIE CAS CSCD 2012年第31期2465-2472,共8页
Repetitive transcranial magnetic stimulation is a noninvasive treatment technique that can directly alter cortical excitability and improve cerebral functional activity in unconscious patients. To investigate the effe... Repetitive transcranial magnetic stimulation is a noninvasive treatment technique that can directly alter cortical excitability and improve cerebral functional activity in unconscious patients. To investigate the effects and the electrophysiological changes of repetitive transcranial magnetic stimulation cortical treatment, 10 stroke patients with non-severe brainstem lesions and with disturbance of consciousness were treated with repetitive transcranial magnetic stimulation. A quantitative electroencephalography spectral power analysis was also performed. The absolute power in the alpha band was increased immediately after the first repetitive transcranial magnetic stimulation treatment, and the energy was reduced in the delta band. The alpha band relative power values slightly decreased at 1 day post-treatment, then increased and reached a stable level at 2 weeks post-treatment. Glasgow Coma Score and JFK Coma Recovery Scale-Revised score were improved. Relative power value in the alpha band was positively related to Glasgow Coma Score and JFK Coma Recovery Scale-Revised score. These data suggest that repetitive transcranial magnetic stimulation is a noninvasive, safe, and effective treatment technology for improving brain functional activity and promoting awakening in unconscious stroke patients. 展开更多
关键词 repetitive transcranial magnetic stimulation consciousness disturbance stroke quantitative electroencephalography nervous excitation consciousness neuroregenerative disease regeneration neural regeneration
下载PDF
Active Vibration Control of Beam Using Electro-magnetic Constrained Layer Damping 被引量:3
3
作者 牛红攀 张亚红 +1 位作者 张希农 谢石林 《Chinese Journal of Aeronautics》 SCIE EI CAS CSCD 2008年第2期115-124,共10页
This paper investigates vibration control of beam through electro-magnetic constrained layer damping (EMCLD) which consists of electromagnet layer, permanent magnet layer and viscoelastic damping layer. When the coi... This paper investigates vibration control of beam through electro-magnetic constrained layer damping (EMCLD) which consists of electromagnet layer, permanent magnet layer and viscoelastic damping layer. When the coil of the electromagnet is electrified with proper control strategy, the electromagnet can exert magnetic force opposite to the direction of structural deformation so that the structural vibration is attenuated. A mathematical model is developed based on the equivalent current method to calculate the electromagnetic control force produced by EMCLD. The governing equations of the system are obtained using Hamilton's Principle and then reduced with the assumed-mode method. A simulation on vibration control of a cantilever beam is conducted under the velocity proportional feedback to demonstrate the energy dissipation capability of EMCLD, and the beam system with the same parameter is experimented. The results of experiment and simulation are compared and the results show that the EMCLD is an effective means for suppressing modal vibration. The results also indicate that the beam system has better control performance for larger control current. The EMCLD method presented in this paper provides an applicable and efficient tool for the vibration control of structures. 展开更多
关键词 electro-magnetic constrained layer damping (EMCLD) vibration control active control
下载PDF
Electro-acupuncture Combined with Transcranial Magnetic Stimulation Improves Learning and Memory Function of Rats with Cerebral Infarction by Inhibiting Neuron Cell Apoptosis 被引量:14
4
作者 李嫚 彭君 +3 位作者 宋艳玲 梁慧 梅元武 方瑗 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 2012年第5期746-749,共4页
This study examined the effect of electro-acupuncture (EA) combined with transcranial magnetic stimulation (TMS) therapy at different time windows on learning and memory ability of rats with cerebral infarction and th... This study examined the effect of electro-acupuncture (EA) combined with transcranial magnetic stimulation (TMS) therapy at different time windows on learning and memory ability of rats with cerebral infarction and the underlying mechanism.Two hundred SD rats were randomly divided into four groups:normal group,sham-operated group,model group and EA+TMS group,and each group was then divided into five sub-groups in terms of the different time to start treatment post operation:6,12,24,48 and 72 h.Cerebral infarction models were established in the model and the EA+TMS groups by left middle cerebral artery occlusion/reperfusion (MCAO/R).After treatment for 14 d,the Morris water maze test was applied to examine the spatial learning and memory abilities of rats.In infarcted area,the expression of caspase-3 was immunohistochemically detected,and real-time fluorescent quantitative PCR was used to measure the expression of Bcl-2 mRNA.The results showed that in EA+TMS group compared with model group at the same treatment time windows,the escape latency was substantially shortened,the expression of caspase-3 was considerably decreased and the expression level of Bcl-2 mRNA significantly increased (P<0.05).In the EA+TMS sub-groups,the escape latency was shortest,the expression level of caspase-3 lowest,and the expression level of Bcl-2 mRNA highest at the treatment time window of 24 h.It was concluded that EA combined with TMS can promote neurological function of rats with cerebral infarction by increasing the expression level of Bcl-2 mRNA and decreasing the expression of caspase-3.The best time window is 24 h after perfusion treatment to ischemia. 展开更多
关键词 cerebral infarction electro-ACUPUNCTURE transcranial magnetic stimulation escape latency APOPTOSIS
下载PDF
Electro-acupuncture at Zusanli(ST 36) to improve lower extremity motor function in sensory disturbance patients with cerebral stroke A randomized controlled study of 240 cases 被引量:3
5
作者 Weijun Gong Tong Zhang Lihua Cui YuqiYang Xinting Sun 《Neural Regeneration Research》 SCIE CAS CSCD 2009年第11期935-940,共6页
BACKGROUND: Studies have shown that sensory transduction is a way to introduce needle sensation. OBJECTIVE: To observe the influence of electro-acupuncture at the "Zusanll" (ST 36) point on lower extremity motor... BACKGROUND: Studies have shown that sensory transduction is a way to introduce needle sensation. OBJECTIVE: To observe the influence of electro-acupuncture at the "Zusanll" (ST 36) point on lower extremity motor function in various sensory disturbance patients with cerebral stroke. DESIGN, TIME AND SETTING: A randomized, controlled, clinical study was performed at the Department of Neurological Rehabilitation, China Rehabilitation Research Centre from September 2006 to June 2008. PARTICIPANTS: Patients with first-time cerebral infarction or hemorrhage, or with a stroke history, but no neurodysfunction (single damage), were selected for this study. The subjects were right-handed and disease state was stable. A total of 240 inpatients were randomly assigned to the following groups: electro-acupuncture (n = 124) and control (n = 116). The two groups were further assigned into sub-groups: no sensory disturbance, superficial sensory disturbance, deep sensory disturbance, and deep and superficial sensory disturbance. METHODS: On the basis of routine limb function training, the acupoint Zusanliwas utilized in all patients from the electro-acupuncture group. Perpendicular acupuncture was 3.0-4.0 cm deep. An electric acupuncture instrument was connected when patients developed the needle sensation, deqi. A stimulation pattern consisting of distant and dense waves of 50 Hz was used to elicit slight dorsal foot extension. Acupuncture was administered 5 times per week, 30 minutes per session, for 6 weeks in total. MAIN OUTCOME MEASURES: FugI-Meyer assessment (FMA) was used to evaluate lower extremity motor function; Ver.1.0 gait analysis to estimate gait (step frequency, step speed, and step scope); lower extremity Composite Spasticity Scale (CSS) to estimate muscle spastic degree. RESULTS: Following treatment, motor function improved in both groups. Compared with the control group, FMA score, step speed, step frequency, and step scope were increased in the electro-acupuncture group, but there was no difference in lower extremity CSS scores between the electro-acupuncture and the control groups (P 〉 0.05). Compared with the control group, Zusanli (ST 36) electro-acupuncture improved motor function indices as follows: FMA score, step frequency, step speed, and step scope of patients with no sensory disturbance (P 〈 0.05-0.01), step frequency of patients with superficial sensory disturbance (P 〈 0.05), and step frequency and step speed of patients with deep sensory disturbance (P 〈 0.05). CONCLUSION: Zusanfi (ST 36) electro-acupuncture effects on lower extremity motor function in stroke patients were improved with no muscle tone rise. Therefore, this form of treatment can be used in convalescent treatment, Moreover, effects were different according to various sensory disturbance types, which suggested that sensory input influenced acupuncture effects. 展开更多
关键词 electro-ACUPUNCTURE Zusanli (ST 36) sensory disturbance motor function sensory input
下载PDF
Investigation of composite electromagnetic scattering from ship-like target on the randomly rough sea surface using FDTD method 被引量:6
6
作者 李娟 郭立新 +1 位作者 曾浩 韩旭彪 《Chinese Physics B》 SCIE EI CAS CSCD 2009年第7期2757-2763,共7页
Composite electromagnetic scattering from a two-dimensional (2D) ship-like target on a one-dimensional sea surface is investigated by using the finite-difference time-domain (FDTD) method. A uniaxial perfectly mat... Composite electromagnetic scattering from a two-dimensional (2D) ship-like target on a one-dimensional sea surface is investigated by using the finite-difference time-domain (FDTD) method. A uniaxial perfectly matched layer is adopted for truncation of FDTD lattices.The FDTD updated equations can be used for the total computation domain by choosing the uniaxial parameters properly. To validate the proposed numerical technique,a 2D infinitely long cylinder over the sea surface is taken into account first.The variation of angular distribution of the scattering changing with incident angle is calculated. The results show good agreement with the conventional moment method. Finally,the influence of the incident angle,the polarization,and the size of the ship-like target on the composite scattering coefficient is discussed in detail. 展开更多
关键词 finite-difference time-domain uniaxial perfectly matched layer sea surface electro-magnetic scattering
下载PDF
Degradation of acid fuchsine by a modified electro-Fenton system with magnetic stirring as oxygen supplying 被引量:2
7
作者 Yiping Sheng,Limin Zhen,Xiuli Wang,Ning Li,Qi Tong College of Environmental and Chemical Engineering,Yanshan University,Qinhuangdao,Hebei 066004,China. 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2010年第4期547-554,共8页
The current modified electro-Fenton system was designed to develop a more convenient and efficient undivided system for practical wastewater treatment. The system adopted a cathode portion that employed magnetic stirr... The current modified electro-Fenton system was designed to develop a more convenient and efficient undivided system for practical wastewater treatment. The system adopted a cathode portion that employed magnetic stirring instead of common oxygen gas diffusion or gas sparging to supply oxygen gas for the electrolyte solution. Key factors influencing the cathode fabrication and activit) were investigated. The degradation of acid fuchsine with a self-made graphite-polytetrafluorethylene cathode was studied using spectrophotometer. It was found that the cathode generated hydrogen peroxide with high current efficiency and the hydrogen peroxide yield of the cathode did not decay after 10 times reuse. With the Pt anode at a ferrous ion concentration of 0.5 mmol/L, a pH of 3, and using magnetic stirring, dye decolorization could be rapidly accomplished but the destruction of benzene rings and intermediates was fairly difficult. With a Fe anode, dye degradation was more complete. 展开更多
关键词 electro-Fenton system oxygen gas magnetic stirring acid fuchsine DEGRADATION
下载PDF
Experimental study of ultralong wave band for electro-magnetic signals and acoustic emission during rock fracture 被引量:2
8
作者 曹惠馨 钱书清 吕智 《Acta Seismologica Sinica(English Edition)》 CSCD 1994年第2期301-308,共8页
The electro-magnetic (EM) and acoustic emission (AE) in the fracture process of both dry and wet rock samples including gabbro, granite, sandstone and marble are studied in the experiment in the laboratory under uniax... The electro-magnetic (EM) and acoustic emission (AE) in the fracture process of both dry and wet rock samples including gabbro, granite, sandstone and marble are studied in the experiment in the laboratory under uniaxial pressure. Signals during the test are detected in ultralow frequency band. The experimental results may be outlined as follows: original waveforms of the electro-magnetic radiation (EMR) and AE in the range of 0-20 kHz frequencies are obtained; the EMR's intensity in fracture process is related to some factors as rock type, content of water, fracture intensity of rocks, loading rates and fracture state etc.; the EMR'S rate is proportional to that of AE during fracture statistically. About 70% of maximum values of EMR rate and AE rate are corresponded with each other; furthermore, the EM signals (EMS) are generally more developed and longer duration than AE signals; the principal energy of EMS detected by copper coin antenna as sensor in power spectra are distributed in frequencies lower than 6 kHz and otherwise those detected by EMinduction coil are at about 10 kHz, and in contrast the major energies of AE are in frequencies less than3 kHz; another notable phenomenon is that distinct electro-magnetic signals are detected before AE occurrence. Since EMR and AE signals obtained in the process of rock fracture are better corresponded to eachother, therefore it'S reasonable to propose that the EMR anormalies observed prior to some earthquakes aremainly produced by fractures of rock in source region, as for the EMS occurred before AE may be related topiezoelectric and piezomagnetic effects. 展开更多
关键词 electro-magnetic radiation acoustic emission main nergy spectrum fracture process
下载PDF
Effects of Exposure to Extremely Low Frequency Electro-magnetic Fields on Circadian Rhythms and Distribution of Some Leukocyte Differentiation Antigens in Dairy Cows 被引量:1
9
作者 CALOGERO STELLETTA PAOLA DE NARDO +4 位作者 FRANCESCO SANTIN GIUSEPPE BASSO BARBARA MICHIELOTTO GIUSEPPE PICCIONE MASSIMO MORGANTE 《Biomedical and Environmental Sciences》 SCIE CAS CSCD 2007年第2期164-170,共7页
Objective To investigate the effects of extremely low frequency magnetic and electric fields (ELFEMFs) emitted from 380 kV transmission lines on some leukocyte differentiation antigens in dairy cows. Methods The stu... Objective To investigate the effects of extremely low frequency magnetic and electric fields (ELFEMFs) emitted from 380 kV transmission lines on some leukocyte differentiation antigens in dairy cows. Methods The study was carded out in 5 cows exposed to 1.98-3.28 μT of ELFEMFs and in 5 control cows exposed to 0.2-0.7 μT of ELFEMFs. Following haematological and immunologic parameters were measured in both groups: WBC, CD45R, CD6, CD4, CD8, CD21, and CD11B leukocyte antigen expression. Results Some of the haematological and immunologic parameters under investigation were similar in both groups. However, CD8 (T lymphocyte surface antigen) was higher in the exposed group (1.35 ±0.120 vs 0.50 ±0.14×10^3/mL). Furthermore, the CD4/CD8 ratio (0.84 ±0.05 and 2.19±0.16 for exposed and not exposed cows respectively) and circadian rhythm were different between the two groups. Conclusion Exposure to ELFEMFs is responsible of the abnormal temporal variations and distribution of some haematological and immunological parameters in dairy cows. 展开更多
关键词 electro-magnetic fields Low frequency LEUKOCYTE Circadian rhythm Dairy cow
下载PDF
Application of chaotic modulation to AC motors for electro magnetic interference suppression
10
作者 崔巍 王建宽 江建中 《Journal of Shanghai University(English Edition)》 CAS 2007年第5期502-505,共4页
Instead of avoiding occurrence of chaos in motor drives, chaos is positively utilized in this paper. A new chaotic pulse width modulation (PWM) scheme is proposed and implemented for AC motors, which functions to si... Instead of avoiding occurrence of chaos in motor drives, chaos is positively utilized in this paper. A new chaotic pulse width modulation (PWM) scheme is proposed and implemented for AC motors, which functions to significantly suppress harmonic peaks and hence acoustic noise. The key is to employ the Chua's circuit for generating a desired chaotic sequence. By using a practical induction motor, computer simulation and experimental results verify that the chaotic PWM has advantages of harmonic peak suppression and simple hardware implementation over the conventional PWM and random PWM. 展开更多
关键词 electro magnetic interference (EMI) Chua's circuit chaotic pulse width modulation (PWM).
下载PDF
Structure and Magnetic Properties of Ni Nanowires Array Fabricated by Direct Current Electro-deposition in Anodic Alumina Membrane
11
作者 黄新民 《Journal of Wuhan University of Technology(Materials Science)》 SCIE EI CAS 2005年第1期75-77,共3页
Ordered nanostructure arrays of Ni-Al 2O 3 were synthesized by direct current electro-deposition in anodic alumina membranes (AAM). The investigation with a n electron microscope,an X-ray diffractmeter and a vibrat... Ordered nanostructure arrays of Ni-Al 2O 3 were synthesized by direct current electro-deposition in anodic alumina membranes (AAM). The investigation with a n electron microscope,an X-ray diffractmeter and a vibration sample magnetomete r indicates that the Ni nanowires, growing in the pores of AAM with about 45nm i n diameter, are monocrystalline and have a definite preferred crystallizing orie ntation. The magnetic behavior of the arrays and their mechanism were discussed. 展开更多
关键词 nanometer materials magnetic property electro-DEPOSITION anodic alumina m embranes (AAM)
下载PDF
APPLICATION OF MAGNETIZATION VISCOUS CHARACTER OF MAGNETIC FLUID IN ELECTRO-HYDRAULIC SERVO AMPLIFIER
12
作者 Zhang Jiancheng Chen Jianwen Wang AilingLiu Chunrong Cao Xinming Zhou ShichangNortheastern University 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 1995年第2期172-175,共4页
The magnetic fluid is used as working medium in pilot stage of electro-hydraulic servoamplifier. Utilizing the magnetization viscous character of the fluid, a new type of electro-hydraulicservo amplifier without any m... The magnetic fluid is used as working medium in pilot stage of electro-hydraulic servoamplifier. Utilizing the magnetization viscous character of the fluid, a new type of electro-hydraulicservo amplifier without any moving parts in its pilot stage has been developed. This research provides a way for improving the frequency property and reliability of electro-hydraulic servoelements. 展开更多
关键词 magnetic fluid Magnetization viscous character Pilot stage electro-Hy-draulic servo amplifier
下载PDF
Microstructure of electromagnetic stirred semi-solid AZ91D alloy 被引量:2
13
作者 毛卫民 甄子胜 +1 位作者 陈洪涛 钟雪友 《中国有色金属学会会刊:英文版》 CSCD 2004年第5期846-850,共5页
The microstructures of semi-solid AZ91D alloy stirred by rotationally electromagnetic field were studied. The shape of primary α-Mg phase is dendrite under conventional solidification condition and the primary α-Mg ... The microstructures of semi-solid AZ91D alloy stirred by rotationally electromagnetic field were studied. The shape of primary α-Mg phase is dendrite under conventional solidification condition and the primary α-Mg grains are changed to the fine rosette-like or granular grains under electromagnetic stirring condition. If the electromagnetic stirring frequencies are low, there are a large amount of fine rosette-like primary α-Mg grains and the fine rosette-like primary α-Mg grain in two dimensions belongs to a single grain in three dimensions; there are also many spherical primary α-Mg grains, they may belong to a single grain in three dimensions and the orientation differences of the grains between them are very small. If the electromagnetic stirring frequencies are high, a lot of the fine rosette-like primary α-Mg grains disappear and are converted into granular grains, and moreover, most of these granular grains belong to different grains in three dimensions. 展开更多
关键词 微观结构 镁合金 电磁性 AZ91D合金 金属元素
下载PDF
Analysis of Excitation Characteristics of Ultra High Frequency Electromagnetic Waves Induced by PD in GIS 被引量:7
14
作者 DING Dengwei GAO Wensheng +2 位作者 YAO Senjing LIU Weidong HE Jiaxi 《高电压技术》 EI CAS CSCD 北大核心 2013年第8期1893-1901,共9页
The understanding of the excitation mechanism of ultra high frequency (UHF) electromagnetic waves (EW) is essential for ap- plying UHF method to partial discharge (PD) detection. Since the EW induced by PD in gas insu... The understanding of the excitation mechanism of ultra high frequency (UHF) electromagnetic waves (EW) is essential for ap- plying UHF method to partial discharge (PD) detection. Since the EW induced by PD in gas insulated switchgear (GIS) contains not only transverse electromagnetic (TEM) wave, but also high-order transverse electric (TE) and high-order transverse magnetic (TM) waves, we analyzed the proportions between the TEM wave and the high order waves, as well as the influence of the PD position on this proportion, using the finite different time domain (FDTD) method. According to the unique characteristics of the waves, they are separated only ap- proximately. It is found that the high-order mode is the main component, more than 70%, of the electric field around the enclosure of GIS, and that with the increasing distance between PD source and inner conductors, the low frequency ( below about 800 MHz) component of EW decreases, but the high frequency component (above 1 GHz) increases, meanwhile the proportion of high-order components in EW could reach 77% from 70%. It concluded that the closer the PD source to the enclosure is, the easier high order EW may be excited. 展开更多
关键词 超高频电磁波 励磁特性 GIS PD 诱导 气体绝缘开关设备 UHF方法 TEM波
下载PDF
INFLUENCE OF 2-BUTYNE-1,4-DIOL ON THE STRUCTURE AND PERFORMANCE OF THE Co-Ni ALLOY PLATED BY ELECTRODEPOSITION 被引量:3
15
作者 S.L. Wang L.L. Hong W.W. Yu 《Acta Metallurgica Sinica(English Letters)》 SCIE EI CAS CSCD 2008年第1期50-56,共7页
The effect of 2-butyne-1, 4-diol (BD) on the deposition behavior of the Co-Ni alloy was investigated by linear sweep voltammetry. The results showed that BD could prevent the deposition of the Co-Ni alloy. The effec... The effect of 2-butyne-1, 4-diol (BD) on the deposition behavior of the Co-Ni alloy was investigated by linear sweep voltammetry. The results showed that BD could prevent the deposition of the Co-Ni alloy. The effect of BD concentration in the sulfate plating bath, on the structure of the Co-Ni deposit was studied by energy dispersive x-ray spectroscopy, scanning electron microscope, and X-ray diffraction, respectively. As a result, BD could smoothen the deposit surface and decrease the diameter of the grain, but too much of BD was not good for the size of the grain. In general, a hexagonal close-packed (hcp) phase of the Co-Ni alloy, with a preferentially oriented (110) plane, was prepared by electrodeposition in the presence of BD. The Co-Ni alloy as a catalyst for the electro-oxidation of ethanol in alkaline medium was investigated by cyclic voltammetry. The deposit plated from the bath containing BD possessed better electro-oxidation of ethanol performance compared with that of the deposit plated from only the sulfate plating bath, but too much of BD was not beneficial for catalytic activity. The Co-Ni film was suitable as a magnetic recording material. 展开更多
关键词 Co-Ni 2-butyne-1 4-diol (BD) electroDEPOSITION electro-oxidation ethanol magnetic property
下载PDF
Neutron Irradiation of Electronic Materials at HANARO
16
作者 Kee-Nam Choo Man-Soon Cho +2 位作者 Byung-Hyuk Jun Chan-Joong Kim Sang-Jun Park 《Journal of Applied Mathematics and Physics》 2014年第9期837-842,共6页
HANARO, a 30 MW open-pool type multipurpose research reactor, has been operated as a platform for nuclear researches in Korea, and irradiation facilities have been mainly utilized for various nuclear material irradiat... HANARO, a 30 MW open-pool type multipurpose research reactor, has been operated as a platform for nuclear researches in Korea, and irradiation facilities have been mainly utilized for various nuclear material irradiation tests requested by users. Although most irradiation tests have been related to national R&D relevant to nuclear power, demand for neutron irradiation of electro-magnetic materials is increasing rapidly at HANARO. Another research reactor, which is named the KIJANG research reactor (KJRR), is under construction in Korea. KJRR is dedicated to increasing the national radio-isotopes supply capacity and to the irradiation facilities including Neutron Transmutation Doping (NTD) facilities for power semiconductor production in a large scale and fast neutron irradiation (FNI) facility for fast neutron irradiation. The NTD and FNI facilities in the KJRR reactor can be effectively utilized on the study of separated effect of thermal and fast neutron irradiations on the properties of electro-magnetic materials. HANARO will also specialize more on irradiation research, including neutron irradiation of electronic materials. The research status and possibility of new electro-magnetic materials using neutron irradiation at HANARO are surveyed to ascertain the utilization of neutron irradiation technology in electro-magnetic material researches. 展开更多
关键词 HANARO NEUTRON IRRADIATION electro-magnetic MATERIAL
下载PDF
Numerical Experiment for Dipole-Dipole Interaction in Electro-Magnetism with Help of a Regular Tetrahedron
17
作者 Panagis G. Papadopoulos Panos D. Kiousis Christos G. Karayannis 《Open Journal of Physical Chemistry》 2019年第1期13-32,共20页
Aim of this work is to try to explain, on a Rational basis, some equations of Electro-Magnetism, which are based on Experimental data. Any Electric Field can produce a Field of many small Electric Dipoles, continuousl... Aim of this work is to try to explain, on a Rational basis, some equations of Electro-Magnetism, which are based on Experimental data. Any Electric Field can produce a Field of many small Electric Dipoles, continuously distributed in space. In a region, where the Electric Field is constant, in direction and magnitude, all the small Dipoles are parallel to the Electric Field, and are represented by a single, long, parallel to them, fixed in space, Electric Dipole, which is here called Compass. An Alternating current, in a straight Conductor, is studied, by a simple, short computer program, for step-by-step nonlinear dynamic analysis. It is found that, only an Alternating current, not a direct current, can produce an Electric Dipole, in a straight Conductor. The two above Dipoles (Compass-Conductor) are assumed with equal lengths &#8467;, lying on two skew lines, perpendicular to each other, at a distance &#8467;√2, thus forming, by their four ends, a Regular Tetrahedron, with side length &#8467;. Repulsion, between Like Charges, obeys the simple Coulomb Electro-Static law. Whereas Interaction (Attraction or Repulsion), between Unlike Charges, obeys a more accurate Lennard-Jones law. The analysis of Dipole-Dipole (Compass-Conductor) Interaction is performed by hand calculator. The only out-of-balance forces, in the regular Tetrahedron, acting on the Rigid Conductor, are the so-called magnetic forces. Their direction is found, in a simple Rational way, with help of Regular Tetrahedron, without recoursing to a “right-hand-rule”. The proposed model is applied to 1) The force acting on an Electric Charge moving in a magnetic field. 2) The force acting on a Current carrying straight Conductor, due to a magnetic field. 3) The magnetic fields created around a Current carrying straight Conductor. In these applications, proposed model gives reasonable results. Particularly, in third application, results, obtained by proposed model, are found in satisfactory approximation with corresponding ones, obtained by an empirical formula, based on relevant Experimental observations of H.-C. Oersted and A.-M. Ampère. So, the reliability of proposed model is checked. Position and direction of magnetic field vector coincide with those of a corresponding fixed Compass of a constant Electric Field. Main point of present work is that, without introducing the concept of a magnetic field vector, by combining field of dipoles, produced by an electric field, with dipole of an alternating current carrying conductor, the magnetic forces can be determined. 展开更多
关键词 ELECTRIC Field ELECTRIC DIPOLE Compass Conductor Alternating Current Step-by-Step Nonlinear Dynamic Algorithm Dipole-Dipole Interaction REGULAR TETRAHEDRON Coulomb electro-Static LAW Lennard-Jones LAW magnetic Field Vector magnetic Forces Oersted-Ampère Rule
下载PDF
Persistent alterations in gray matter in COVID-19 patients experiencing sleep disturbances:a 3-month longitudinal study
18
作者 Kaixuan Zhou Gaoxiong Duan +19 位作者 Ying Liu Bei Peng Xiaoyan Zhou Lixia Qin Lingyan Liang Yichen Wei Qingping Zhang Xiaocheng Li Haixia Qin Yinqi Lai Yian Lu Yan Zhang Jiazhu Huang Jinli Huang Yinfei Ouyang Bolin Bin Mingming Zhao Jun Liu Jianrong Yang Demao Deng 《Neural Regeneration Research》 SCIE CAS 2025年第10期3013-3024,共12页
Sleep disturbances are among the most prevalent neuropsychiatric symptoms in individuals who have recovered from severe acute respiratory syndrome coronavirus 2 infections.Previous studies have demonstrated abnormal b... Sleep disturbances are among the most prevalent neuropsychiatric symptoms in individuals who have recovered from severe acute respiratory syndrome coronavirus 2 infections.Previous studies have demonstrated abnormal brain structures in patients with sleep disturbances who have recovered from coronavirus disease 2019(COVID-19).However,neuroimaging studies on sleep disturbances caused by COVID-19 are scarce,and existing studies have primarily focused on the long-term effects of the virus,with minimal acute phase data.As a result,little is known about the pathophysiology of sleep disturbances in the acute phase of COVID-19.To address this issue,we designed a longitudinal study to investigate whether alterations in brain structure occur during the acute phase of infection,and verified the results using 3-month follow-up data.A total of 26 COVID-19 patients with sleep disturbances(aged 51.5±13.57 years,8 women and 18 men),27 COVID-19 patients without sleep disturbances(aged 47.33±15.98 years,9 women and 18 men),and 31 age-and gender-matched healthy controls(aged 49.19±17.51 years,9 women and 22 men)were included in this study.Eleven COVID-19 patients with sleep disturbances were included in a longitudinal analysis.We found that COVID-19 patients with sleep disturbances exhibited brain structural changes in almost all brain lobes.The cortical thicknesses of the left pars opercularis and left precuneus were significantly negatively correlated with Pittsburgh Sleep Quality Index scores.Additionally,we observed changes in the volume of the hippocampus and its subfield regions in COVID-19 patients compared with the healthy controls.The 3-month follow-up data revealed indices of altered cerebral structure(cortical thickness,cortical grey matter volume,and cortical surface area)in the frontal-parietal cortex compared with the baseline in COVID-19 patients with sleep disturbances.Our findings indicate that the sleep disturbances patients had altered morphology in the cortical and hippocampal structures during the acute phase of infection and persistent changes in cortical regions at 3 months post-infection.These data improve our understanding of the pathophysiology of sleep disturbances caused by COVID-19. 展开更多
关键词 brain structure cortical gray matter volume cortical surface area cortical thickness HIPPOCAMPUS magnetic resonance imaging Pittsburgh Sleep Quality Index severe acute respiratory syndrome coronavirus 2 infections sleep disturbances sub-cortical volume
下载PDF
The Relevance between Symptoms and Magnetic Resonance Imaging Analysis of the Hippocampus of Depressed Patients Given Electro-acupuncture Combined with Fluoxetine Intervention - A Randomized,Controlled Trial 被引量:7
19
作者 段冬梅 图娅 +1 位作者 焦爽 秦文 《Chinese Journal of Integrative Medicine》 SCIE CAS 2011年第2期190-199,共10页
Objective: To probe the relevance between depressive symptoms and hippocampal volume and its metabolites detected by magnetic resonance imaging (MRI) in depressed patients who were given electro- acupuncture (EA)... Objective: To probe the relevance between depressive symptoms and hippocampal volume and its metabolites detected by magnetic resonance imaging (MRI) in depressed patients who were given electro- acupuncture (EA) combined with Fluoxetine before and after treatment. Methods: A randomized, controlled trial was conducted. A total of 75 cases of mild or moderate depression were randomly assigned to two groups: the EA group which received EA combined with Fluoxetine; the Fluoxetine group which received Fluoxetine only as the control. The 17-item Hamilton Scale for Depression (HAMD) was used to assess the depression level. The relevance between the changes of the hippocampal volume and its metabolites, including N-acetyl aspartate (NAA)/creatine (Cr) and choline containing compounds (Cho)/Cr, and the reduction rate of the HAMD score before and after treatment of the two groups were analyzed. Results: At the end of the treatment, the therapeutic response rates were not statistically different between the two groups (73.53% for the Fluoxetine group and 83.33% for the EA group, respectively). Compared to that of the Fluoxetine group, a significant difference was shown in the EA group in the reduction rate of the HAMD scores (P〈0.05). There was a negative correlation between the therapeutic effect and the HAMD scores before treatment in both groups of patients. There was no significant difference in the hippocampal volume before and after treatment. The NAA/Cr ratio of both groups increased after treatment, with the EA group increasing more. There was a negative correlation between the rate of change of the NAA/Cr after treatment and the HAMD scores before treatment in the two groups. In the Fluoxetine group, the Cho/Cr ratio showed no significant difference before and after treatment, which had no relevance with the HAMD scores before treatment either. Meanwhile, in the EA group, the Cho/Cr ratio showed a significant difference before and after treatment, which also had a positive relevance with the HAMD scores before treatment. Conclusions: There was a significant improvement in the hippocampal metabolites in depressed patients who treated by EA combined with Fluoxetine. Those differences showed relevance with the HAMD scores before treatment. 展开更多
关键词 depression electro-ACUPUNCTURE HIPPOCAMPUS magnetic resonance imaging FLUOXETINE
原文传递
Fuzzy impedance control of an electro-hydraulic actuator with an extended disturbance observer 被引量:2
20
作者 Mingjie LI Jian-hua WEI +2 位作者 Jin-hui FANG Wen-zhuo SHI Kai GUO 《Frontiers of Information Technology & Electronic Engineering》 SCIE EI CSCD 2019年第9期1221-1233,共13页
In this paper,we deal with both velocity control and force control of a single-rod electro-hydraulic actuator subject to external disturbances and parameter uncertainties.In some implementations,both velocity control ... In this paper,we deal with both velocity control and force control of a single-rod electro-hydraulic actuator subject to external disturbances and parameter uncertainties.In some implementations,both velocity control and force control are required.Impedance control and an extended disturbance observer are combined to solve this issue.Impedance control is applied to regulate the dynamic relationship between the velocity and output force of the actuator,which can help avoid impact and keep a proper contact force on the environment or workpieces.Parameters of impedance rules are regulated by a fuzzy algorithm.An extended disturbance observer is employed to account for external disturbances and parameter uncertainties to achieve an accurate velocity tracking.A detailed model of load force dynamics is presented for the development of the extended disturbance observer.The stability of the whole system is analyzed.Experimental results demonstrate that the proposed control strategy has not only a high velocity tracking performance,but also a good force adjustment performance,and that it should be widely applied in construction and assembly. 展开更多
关键词 FUZZY CONTROL Impedance CONTROL disturbance observer Parameter UNCERTAINTIES electro-HYDRAULIC actuator
原文传递
上一页 1 2 127 下一页 到第