期刊文献+
共找到7,529篇文章
< 1 2 250 >
每页显示 20 50 100
Active Vibration Control of Beam Using Electro-magnetic Constrained Layer Damping 被引量:3
1
作者 牛红攀 张亚红 +1 位作者 张希农 谢石林 《Chinese Journal of Aeronautics》 SCIE EI CAS CSCD 2008年第2期115-124,共10页
This paper investigates vibration control of beam through electro-magnetic constrained layer damping (EMCLD) which consists of electromagnet layer, permanent magnet layer and viscoelastic damping layer. When the coi... This paper investigates vibration control of beam through electro-magnetic constrained layer damping (EMCLD) which consists of electromagnet layer, permanent magnet layer and viscoelastic damping layer. When the coil of the electromagnet is electrified with proper control strategy, the electromagnet can exert magnetic force opposite to the direction of structural deformation so that the structural vibration is attenuated. A mathematical model is developed based on the equivalent current method to calculate the electromagnetic control force produced by EMCLD. The governing equations of the system are obtained using Hamilton's Principle and then reduced with the assumed-mode method. A simulation on vibration control of a cantilever beam is conducted under the velocity proportional feedback to demonstrate the energy dissipation capability of EMCLD, and the beam system with the same parameter is experimented. The results of experiment and simulation are compared and the results show that the EMCLD is an effective means for suppressing modal vibration. The results also indicate that the beam system has better control performance for larger control current. The EMCLD method presented in this paper provides an applicable and efficient tool for the vibration control of structures. 展开更多
关键词 electro-magnetic constrained layer damping (EMCLD) vibration control active control
下载PDF
On vibration analysis of functionally graded carbon nanotube reinforced magneto-electro-elastic plates with different electro-magnetic conditions using higher order finite element methods 被引量:3
2
作者 M.Vinyas D.Harursampath S.C.Kattimani 《Defence Technology(防务技术)》 SCIE EI CAS CSCD 2021年第1期287-303,共17页
This article deals with evaluating the frequency response of functionally graded carbon nanotube reinforced magneto-electro-elastic(FG-CNTMEE)plates subjected to open and closed electro-magnetic circuit conditions.In ... This article deals with evaluating the frequency response of functionally graded carbon nanotube reinforced magneto-electro-elastic(FG-CNTMEE)plates subjected to open and closed electro-magnetic circuit conditions.In this regard finite element formulation has been derived.The plate kinematics adjudged via higher order shear deformation theory(HSDT)is considered for evaluation.The equations of motion are obtained with the help of Hamilton’s principle and solved using condensation technique.It is found that the convergence and accuracy of the present FE formulation is very good to address the vibration problem of FG-CNTMEE plate.For the first time,frequency response analysis of FG-CNTMEE plates considering the effect of various circuit conditions associated with parameters such as CNT distributions,volume fraction,skew angle,aspect ratio,length-to-thickness ratio and coupling fields has been carried out.The results of this article can serve as benchmark for future development and analysis of smart structures. 展开更多
关键词 Carbon nanotube MAGNETO-ELECTRO-ELASTIC Higher order shear deformation theory Coupled frequency electro-magnetic conditions
下载PDF
Effects of Exposure to Extremely Low Frequency Electro-magnetic Fields on Circadian Rhythms and Distribution of Some Leukocyte Differentiation Antigens in Dairy Cows 被引量:1
3
作者 CALOGERO STELLETTA PAOLA DE NARDO +4 位作者 FRANCESCO SANTIN GIUSEPPE BASSO BARBARA MICHIELOTTO GIUSEPPE PICCIONE MASSIMO MORGANTE 《Biomedical and Environmental Sciences》 SCIE CAS CSCD 2007年第2期164-170,共7页
Objective To investigate the effects of extremely low frequency magnetic and electric fields (ELFEMFs) emitted from 380 kV transmission lines on some leukocyte differentiation antigens in dairy cows. Methods The stu... Objective To investigate the effects of extremely low frequency magnetic and electric fields (ELFEMFs) emitted from 380 kV transmission lines on some leukocyte differentiation antigens in dairy cows. Methods The study was carded out in 5 cows exposed to 1.98-3.28 μT of ELFEMFs and in 5 control cows exposed to 0.2-0.7 μT of ELFEMFs. Following haematological and immunologic parameters were measured in both groups: WBC, CD45R, CD6, CD4, CD8, CD21, and CD11B leukocyte antigen expression. Results Some of the haematological and immunologic parameters under investigation were similar in both groups. However, CD8 (T lymphocyte surface antigen) was higher in the exposed group (1.35 ±0.120 vs 0.50 ±0.14×10^3/mL). Furthermore, the CD4/CD8 ratio (0.84 ±0.05 and 2.19±0.16 for exposed and not exposed cows respectively) and circadian rhythm were different between the two groups. Conclusion Exposure to ELFEMFs is responsible of the abnormal temporal variations and distribution of some haematological and immunological parameters in dairy cows. 展开更多
关键词 electro-magnetic fields Low frequency LEUKOCYTE Circadian rhythm Dairy cow
下载PDF
Research on Electro-Magnetic Environment of UHV Transmission Lines
4
作者 Wu Guifang Lu Jiayu +1 位作者 Shao Fangyin Ye Qing 《Electricity》 2005年第3期42-46,共5页
Employing even higher voltage level to promote power transmission economy is an important subject in the program of power transmission from west to east. The influence of electro-magnetic environment of transmission p... Employing even higher voltage level to promote power transmission economy is an important subject in the program of power transmission from west to east. The influence of electro-magnetic environment of transmission project being closely related with human health and construction cost has to be seriously considered before advancing transmission voltage. This paper analyzes and discusses overseas and domestic research achievements on radio interference, audible noise, power frequency electric field, power frequency magnetic fields, DC resultant field intensity and ion stream involved in power transmission at ultra-high-voltage (UHV)AC and ± 800 kV DC or even higher voltage levels. Suggestions on limiting electro-magnetic effects and their ceiling value as well as measures to improve electro-magnetic environment are put forward. 展开更多
关键词 electro-magnetic environment power transmission DC UHV
下载PDF
Eddy Currents and Electro-magnetic Forces on the Lower Hybrid Ware Launching Antenna on the Superconducting Tokamak HT-7
5
作者 余家文 匡光力 +1 位作者 丁泊江 林建安 《Plasma Science and Technology》 SCIE EI CAS CSCD 2000年第3期303-309,共7页
This paper analyzes the eddy currents and the electro-magnetic forces on the lower hybrid wave (LHW) launching antenna on the superconducting Tohamak HT-7 by using a finite element circult method. A new iterative algo... This paper analyzes the eddy currents and the electro-magnetic forces on the lower hybrid wave (LHW) launching antenna on the superconducting Tohamak HT-7 by using a finite element circult method. A new iterative algorithm is developed to analyze the coupled magnetic fields Which are very difficult to be calculated. The method and results obtained are helpful to study the eddy currents and electro-magnetic forces on metal plates which are placed in a rather complicated electro-magnetic environment. 展开更多
关键词 CM Eddy Currents and electro-magnetic Forces on the Lower Hybrid Ware Launching Antenna on the Superconducting Tokamak HT-7
下载PDF
Surgeon Perspectives on Anastomotic Leaks and FluidAI’s StreamTM Platform: Integrating Qualitative Insights for Technological Innovation
6
作者 Olivia Rennie Manaswi Sharma Nour Helwa 《Surgical Science》 2024年第8期492-500,共9页
Purpose: This article investigates the critical importance of integrating surgeons’ direct input into the development of innovative technologies that address gaps in surgical care, including those aimed at reducing a... Purpose: This article investigates the critical importance of integrating surgeons’ direct input into the development of innovative technologies that address gaps in surgical care, including those aimed at reducing anastomotic leaks (AL), a major complication in gastrointestinal surgery. While traditional quantitative research methods are prevalent, they often overlook the invaluable insights of the surgeons who manage these complications firsthand. Subjects and Methods: This study employs a qualitative approach, utilizing semi-structured interviews with 40 surgeons from various specialties, including general, bariatric, colorectal, trauma, hepato-biliary, and thoracic surgery. The interviews were designed to probe the needs of surgeons, challenges currently faced, and gaps in clinical practice, research, and technology for detection and/or management of AL. The data were analyzed using thematic analysis, which revealed significant gaps in current technologies for early detection and prevention of leaks. Results: Surgeons expressed strong interest in FluidAI’s Stream™ Platform, a non-invasive medical device designed to monitor postoperative drainage fluid in real-time, providing continuous data on AL risk. The ability of this platform to offer early prediction through pH and electrical conductivity analysis was particularly appealing to participants, who emphasized the importance of timely interventions in improving patient outcomes. The study’s findings highlight not only the clinical challenges but also the emotional toll that AL takes on surgeons, underlining the need for innovations that are both data-driven and humanistic. Conclusion: By centering surgeons’ perspectives, this research advocates for a human-centered approach to technological advancement, ensuring that new tools are both clinically effective and aligned with the real-world needs of surgical practitioners. 展开更多
关键词 Anastomotic leaks Surgeon Perspectives Postoperative Complications Qualitative Inquiry Technological Innovation
下载PDF
Construction and validation of a risk-prediction model for anastomotic leakage after radical gastrectomy: A cohort study in China
7
作者 Jinrui Wang Xiaolin Liu +6 位作者 Hongying Pan Yihong Xu Mizhi Wu Xiuping Li Yang Gao Meijuan Wang Mengya Yan 《Laparoscopic, Endoscopic and Robotic Surgery》 2024年第1期34-43,共10页
Objectives:Anastomotic leakage(AL)stands out as a prevalent and severe complication following gastric cancer surgery.It frequently precipitates additional serious complications,significantly influencing the overall su... Objectives:Anastomotic leakage(AL)stands out as a prevalent and severe complication following gastric cancer surgery.It frequently precipitates additional serious complications,significantly influencing the overall survival time of patients.This study aims to enhance the risk-assessment strategy for AL following gastrectomy for gastric cancer.Methods:This study included a derivation cohort and validation cohort.The derivation cohort included patients who underwent radical gastrectomy at Sir Run Run Shaw Hospital,Zhejiang University School of Medicine,from January 1,2015 to December 31,2020.An evidence-based predictor questionnaire was crafted through extensive literature review and panel discussions.Based on the questionnaire,inpatient data were collected to form a model-derivation cohort.This cohort underwent both univariate and multivariate analyses to identify factors associated with AL events,and a logistic regression model with stepwise regression was developed.A 5-fold cross-validation ensured model reliability.The validation cohort included patients from August 1,2021 to December 31,2021 at the same hospital.Using the same imputation method,we organized the validation-queue data.We then employed the risk-prediction model constructed in the earlier phase of the study to predict the risk of AL in the subjects included in the validation queue.We compared the predictions with the actual occurrence,and evaluated the external validation performance of the model using model-evaluation indicators such as the area under the receiver operating characteristic curve(AUROC),Brier score,and calibration curve.Results:The derivation cohort included 1377 patients,and the validation cohort included 131 patients.The independent predictors of AL after radical gastrectomy included age65 y,preoperative albumin<35 g/L,resection extent,operative time240 min,and intraoperative blood loss90 mL.The predictive model exhibited a solid AUROC of 0.750(95%CI:0.694e0.806;p<0.001)with a Brier score of 0.049.The 5-fold cross-validation confirmed these findings with a calibrated C-index of 0.749 and an average Brier score of 0.052.External validation showed an AUROC of 0.723(95%CI:0.564e0.882;p?0.006)and a Brier score of 0.055,confirming reliability in different clinical settings.Conclusions:We successfully developed a risk-prediction model for AL following radical gastrectomy.This tool will aid healthcare professionals in anticipating AL,potentially reducing unnecessary interventions. 展开更多
关键词 Stomach neoplasms Anastomotic leak Risk factors Prediction model Risk assessment
下载PDF
Preoperative neutrophil-to-lymphocyte ratio predicts symptomatic anastomotic leakage in elderly colon cancer patients: Multicenter propensity score-matched analysis
8
作者 Chao-Yang Wang Xiao-Long Li +3 位作者 Xiao-Long Ma Xiong-Fei Yang Yong-Yong Liu Yong-Jiang Yu 《World Journal of Gastrointestinal Surgery》 SCIE 2024年第2期438-450,共13页
BACKGROUND The neutrophil-to-lymphocyte ratio(NLR),a composite inflammatory biomarker,is associated with the prognosis in patients with colorectal tumors.However,whether the NLR can be used as a predictor of symptomat... BACKGROUND The neutrophil-to-lymphocyte ratio(NLR),a composite inflammatory biomarker,is associated with the prognosis in patients with colorectal tumors.However,whether the NLR can be used as a predictor of symptomatic postoperative ana-stomotic leakage(AL)in elderly patients with colon cancer is unclear.AIM To assess the role of the NLR in predicting the occurrence of symptomatic AL after surgery in elderly patients with colon cancer.METHODS Data from elderly colon cancer patients who underwent elective radical colectomy with anastomosis at three centers between 2018 and 2022 were retrospectively analyzed.Receiver operating characteristic curve analysis was performed to determine the best predictive cutoff value for the NLR.Twenty-two covariates were matched using a 1:1 propensity score matching method,and univariate and multivariate logistic regression analyses were used to determine risk factors for the development of postoperative AL.RESULTS Of the 577 patients included,36(6.2%)had symptomatic AL.The optimal cutoff value of the NLR for predicting AL was 2.66.After propensity score matching,the incidence of AL was significantly greater in the≥2.66 NLR subgroup than in the<2.66 NLR subgroup(11.5%vs 2.5%;P=0.012).Univariate logistic regression analysis revealed statistically significant correlations between blood transfusion intraoperatively and within 2 d postoper-atively,preoperative albumin concentration,preoperative prognostic nutritional index,and preoperative NLR and AL occurrence(P<0.05);multivariate logistic regression analysis revealed that an NLR≥2.66[odds ratio(OR)=5.51;95%confidence interval(CI):1.50-20.26;P=0.010]and blood transfusion intraoperatively and within 2 d postoperatively(OR=2.52;95%CI:0.88-7.25;P=0.049)were risk factors for the occurrence of symptomatic AL.CONCLUSION A preoperative NLR≥2.66 and blood transfusion intraoperatively and within 2 d postoperatively are associated with a higher incidence of postoperative symptomatic AL in elderly patients with colon cancer.The preoperative NLR has predictive value for postoperative symptomatic AL after elective surgery in elderly patients with colon cancer. 展开更多
关键词 Colon cancer Anastomotic leak Neutrophil-to-lymphocyte ratio Propensity score-matched
下载PDF
Impact of open hepatectomy on postoperative bile leakage in patients with biliary tract cancer
9
作者 Gang Wu Wen-Ying Li +2 位作者 Yu-Xing Gong Feng Lin Chen Sun 《World Journal of Gastrointestinal Surgery》 SCIE 2024年第1期67-75,共9页
BACKGROUND Bile leakage is a common and serious complication of open hepatectomy for the treatment of biliary tract cancer.AIM To evaluate the incidence,risk factors,and management of bile leakage after open hepatecto... BACKGROUND Bile leakage is a common and serious complication of open hepatectomy for the treatment of biliary tract cancer.AIM To evaluate the incidence,risk factors,and management of bile leakage after open hepatectomy in patients with biliary tract cancer.METHODS We retrospectively analyzed 120 patients who underwent open hepatectomy for biliary tract cancer from February 2018 to February 2023.Bile leak was defined as bile drainage from the surgical site or drain or the presence of a biloma on imaging.The incidence,severity,timing,location,and treatment of the bile leaks were recorded.The risk factors for bile leakage were analyzed using univariate and multivariate logistic regression analyses.RESULTS The incidence of bile leak was 16.7%(20/120),and most cases were grade A(75%,15/20)according to the International Study Group of Liver Surgery classification.The median time of onset was 5 d(range,1-14 d),and the median duration was 7 d(range,2-28 d).The most common location of bile leakage was the cut surface of the liver(70%,14/20),followed by the anastomosis site(25%,5/20)and the cystic duct stump(5%,1/20).Most bile leaks were treated conservatively with drainage,antibiotics,and nutritional support(85%,17/20),whereas some required endoscopic retrograde cholangiopancreatography with stenting(10%,2/20)or percutaneous transhepatic cholangiography with drainage(5%,1/20).Risk factors for bile leakage include male sex,hepatocellular carcinoma,major hepatectomy,blood loss,and blood transfusion.CONCLUSION Bile leakage is a frequent complication of open hepatectomy for biliary tract cancer.However,most cases are mild and can be conservatively managed.Male sex,hepatocellular carcinoma,major hepatectomy,blood loss,and blood transfusion were associated with an increased risk of bile leak. 展开更多
关键词 Open hepatectomy Bile leak Biliary tract cancer Risk factors Management COMPLICATION
下载PDF
Endoscopic ultrasound-guided tissue sampling induced pancreatic duct leak resolved by the placement of a pancreatic stent:A case report
10
作者 Ki-Hyun Kim Chang Hwan Park +1 位作者 Eunae Cho Yohan Lee 《World Journal of Clinical Cases》 SCIE 2024年第9期1677-1684,共8页
BACKGROUND Pancreatic ductal leaks complicated by endoscopic ultrasonography-guided tissue sampling(EUS-TS)can manifest as acute pancreatitis.CASE SUMMARY A 63-year-old man presented with persistent abdominal pain and... BACKGROUND Pancreatic ductal leaks complicated by endoscopic ultrasonography-guided tissue sampling(EUS-TS)can manifest as acute pancreatitis.CASE SUMMARY A 63-year-old man presented with persistent abdominal pain and weight loss.Diagnosis:Laboratory findings revealed elevated carbohydrate antigen 19-9(5920 U/mL)and carcinoembryonic antigen(23.7 ng/mL)levels.Magnetic resonance imaging of the pancreas revealed an approximately 3 cm ill-defined space-occupying lesion in the inferior aspect of the head,with severe encasement of the superior mesenteric artery.Pancreatic ductal adenocarcinoma was confirmed after pathological examination of specimens obtained by EUS-TS using the fanning method.Interventions and outcomes:The following day,the patient experienced severe abdominal pain with high amylase(265 U/L)and lipase(1173 U/L)levels.Computed tomography of the abdomen revealed edematous wall thickening of the second portion of the duodenum with adjacent fluid collections and a suspicious leak from either the distal common bile duct or the main pancreatic duct in the head.Endoscopic retrograde cholangiopancreatography revealed dye leakage in the head of the main pancreatic duct.Therefore,a 5F 7 cm linear plastic stent was deployed into the pancreatic duct to divert the pancreatic juice.The patient’s abdominal pain improved immediately after pancreatic stent insertion,and amylase and lipase levels normalized within a week.Neoadjuvant chemotherapy was then initiated.CONCLUSION Using the fanning method in EUS-TS can inadvertently cause damage to the pancreatic duct and may lead to clinically significant pancreatitis.Placing a pancreatic stent may immediately resolve acute pancreatitis and shorten the waiting time for curative therapy.When using the fanning method during EUSTS,ductal structures should be excluded to prevent pancreatic ductal leakage. 展开更多
关键词 Endoscopic ultrasound-guided tissue sampling PANCREATITIS Pancreatic duct leak Pancreatic stent Case report
下载PDF
Sinusoidal FM Fuze's Channel Leak and Its Jamming Mechanism 被引量:1
11
作者 韩传钊 施聚生 崔占忠 《Journal of Beijing Institute of Technology》 EI CAS 1999年第4期392-397,共6页
Aim To get the theory base of designing FM fuze's jamming signal, its jamming mechanism was studied. Methods A sinusoidal FM fuze was analyzed in time domain and frequency domain and the concept of channel lea... Aim To get the theory base of designing FM fuze's jamming signal, its jamming mechanism was studied. Methods A sinusoidal FM fuze was analyzed in time domain and frequency domain and the concept of channel leak was presented. Results It was proved that information channel leak exists in FM fuze because of the nonlinear property of the mixer. The jamming signal was designed based on the channel leak and the jamming mechanism was analyzed in detail. Conclusion This kind of jamming signal can jam the sinusoidal FM fuzes effectively just depending on the jamming signal's feature itself. It's different from the traditional jamming way of simulating echo. Though the sinusoidal FM fuze was just analyzed, the principle is applicable to all FM fuzes. At the same time, it may be used as the reference for FM radar and communication countermeasures. 展开更多
关键词 FM fuze channel leak jamming mechanism jamming signal
下载PDF
基于LEAK软件对液氯制取系统中装置泄漏概率的预测研究 被引量:1
12
作者 方枝 郭海林 +1 位作者 李超锋 李伟 《安全与环境工程》 CAS 北大核心 2018年第1期149-153,共5页
氯碱厂液氯制取系统是一个密封性的循环系统,循环介质为液氯及氯气,一旦发生泄漏将造成人员中毒,危及到作业人员的身体健康。为定量计算氯气液化装置的泄漏概率,以某氯碱厂液氯制取系统中装置为研究对象,运用挪威船级社(DNV)的设备同类... 氯碱厂液氯制取系统是一个密封性的循环系统,循环介质为液氯及氯气,一旦发生泄漏将造成人员中毒,危及到作业人员的身体健康。为定量计算氯气液化装置的泄漏概率,以某氯碱厂液氯制取系统中装置为研究对象,运用挪威船级社(DNV)的设备同类失效概率数据库,利用LEAK软件,以泄漏源工况为主要随机性因素,通过辨识研究装置中气体泄漏危险源、构建装置泄漏定量预测模型、修正相关系数,进而对氯气液化装置的泄漏概率进行了模拟计算,得出装置可能的泄漏位置和泄漏概率,可为化工企业安全管理提供指导。 展开更多
关键词 液氯制取系统 泄漏概率 leak软件
下载PDF
使用Visual Leak Detector检测c/c++程序内存泄漏 被引量:2
13
作者 杨磊 汪仁煌 +1 位作者 刘洪江 黄颖怡 《电脑与电信》 2008年第7期81-83,共3页
针对内存泄漏检测问题,本文通过示例说明使用软件Visual Leak Detector来检测泄漏点的方法。通过实验说明该方法在检测一般的c/c++程序内存泄漏时,可以提高检测效率。
关键词 内存泄漏 VISUAL leak DETECTOR C/C++
下载PDF
PHAST&LEAK软件在原油中转站事故后果评价中的应用
14
作者 王明凤 丁鹏 罗文波 《广州化工》 CAS 2011年第9期193-195,共3页
分析了原油中转站的危险特性,以及可能发生的潜在的火灾、爆炸等危险事故。在分析了原油中转站的设备布置、介质的性质以及场站的人员分布情况的基础上,参照国外部分国家采用的个人风险值和社会风险值,运用PHAST&LEAK软件对原油中转站... 分析了原油中转站的危险特性,以及可能发生的潜在的火灾、爆炸等危险事故。在分析了原油中转站的设备布置、介质的性质以及场站的人员分布情况的基础上,参照国外部分国家采用的个人风险值和社会风险值,运用PHAST&LEAK软件对原油中转站进行了整体的风险评价,得出了该场站的油气泄漏火灾爆炸风险水平,对该站的安全运营提供了很好的指导作用。 展开更多
关键词 原油中转站 个人风险值 社会风险值 PHAST&leak 风险评估
下载PDF
Endoscopic management of gastrointestinal perforations, leaks and fistulas 被引量:10
15
作者 Pawel Rogalski Jaroslaw Daniluk +2 位作者 Andrzej Baniukiewicz Eugeniusz Wroblewski Andrzej Dabrowski 《World Journal of Gastroenterology》 SCIE CAS 2015年第37期10542-10552,共11页
Gastrointestinal perforations, leaks and fistulas may be serious and life-threatening. The increasing number of endoscopic procedures with a high risk of perforation and the increasing incidence of leakage associated ... Gastrointestinal perforations, leaks and fistulas may be serious and life-threatening. The increasing number of endoscopic procedures with a high risk of perforation and the increasing incidence of leakage associated with bariatric operations call for a minimally invasive treatment for these complications. The therapeutic approach can vary greatly depending on the size,location, and timing of gastrointestinal wall defect recognition. Some asymptomatic patients can be treated conservatively, while patients with septic symptoms or cardio-pulmonary insufficiency may require intensive care and urgent surgical treatment.However, most gastrointestinal wall defects can be satisfactorily treated by endoscopy. Although the initial endoscopic closure rates of chronic fistulas is very high, the long-term results of these treatments remain a clinical problem. The efficacy of endoscopic therapy depends on several factors and the best mode of treatment will depend on a precise localization of the site, the extent of the leak and the endoscopic appearance of the lesion. Many endoscopic tools for effective closure of gastrointestinal wall defects are currently available. In this review, we summarized the basic principles of the management of acute iatrogenic perforations, as well as of postoperative leaks and chronic fistulas of the gastrointestinal tract. We also described the effectiveness of various endoscopic methods based on current research and our experience. 展开更多
关键词 Endoscopic Management PERFORATION leak FISTULA STE
下载PDF
Management of low colorectal anastomotic leak:Preserving the anastomosis 被引量:5
16
作者 Jennifer Blumetti Herand Abcarian 《World Journal of Gastrointestinal Surgery》 SCIE CAS 2015年第12期378-383,共6页
Anastomotic leak continues to be a dreaded complication after colorectal surgery, especially in the low colorectal or coloanal anastomosis. However, there has been no consensus on the management of the low colorectal ... Anastomotic leak continues to be a dreaded complication after colorectal surgery, especially in the low colorectal or coloanal anastomosis. However, there has been no consensus on the management of the low colorectal anastomotic leak. Currently operative procedures are reserved for patients with frank purulent or feculent peritonitis and unstable vital signs, and vary from simple fecal diversion with drainage to resection of the anastomosis and closure of the rectal stump with end colostomy(Hartmann's procedure). However, if the patient is stable, and the leak is identified days or even weeks postoperatively, less aggressive therapeutic measures may result in healing of the leak and salvage of the anastomosis. Advances in diagnosis and treatment of pelvic collections with percutaneous treatments, and newer methods of endoscopic therapies for the acutely leaking anastomosis, such as use of the endosponge, stents or clips, have greatly reduced the need for surgical intervention in selected cases. Diverting ileostomy, if not already in place, may be considered to reduce fecal contamination. For subclinical leaks or those that persist after the initial surgery, endoluminal approaches such as injection of fibrin sealant, use of endoscopic clips, or transanal closure of the very low anastomosis may be utilized. These newer techniques have variable success rates and must be individualized to the patient, with the goal of treatment being restoration of gastrointestinal continuity and healing of the anastomosis. A review of the treatment of low colorectal anastomotic leaks is presented. 展开更多
关键词 Anastomotic leak COLON and RECTAL surgery Colorectal ANASTOMOSIS MANAGEMENT anastomotic leak Endoscopic treatment Surgical complications
下载PDF
Evaluation of fully covered self-expanding metal stents in benign biliary strictures and bile leaks 被引量:9
17
作者 David Lalezari Inder Singh +1 位作者 Sofiya Reicher Viktor Ernst Eysselein 《World Journal of Gastrointestinal Endoscopy》 CAS 2013年第7期332-339,共8页
AIM: To investigate the use of fully covered metal stents in benign biliary strictures (BBS) and bile leaks. METHODS: We studied 17 patients, at Harbor-UCLA Medical center (Los Angeles), with BBS (n=12) and bile leaks... AIM: To investigate the use of fully covered metal stents in benign biliary strictures (BBS) and bile leaks. METHODS: We studied 17 patients, at Harbor-UCLA Medical center (Los Angeles), with BBS (n=12) and bile leaks (n=5) from July 2007 to February 2012 that had received placement of fully covered self-expanding metal stents (FCSEMs). Fourteen patients had endoscopic placement of VIABIL (Conmed, Utica, New York, United States) stents and three had Wallflex (Boston Scientific, Mass) stents. FCSEMS were 8 mm or 10 mm in diameter and 4 cm to 10 cm in length. Patients were followed at regular intervals to evaluate for symptoms and liver function tests. FCSEMS were removed after 4 or more weeks. Resolution of BBS and leak was documented cholangiographically following stent removal. Stent patency can be defined as adequate bile and contrast flow from the stent and into the ampulla during endoscopic retrograde cholangiopancreatography (ERCP) without clinical signs and/or symptoms of biliary obstruction. Criterion for bile leak resolution at ERCP is defined as absence of contrast extravasation from the common bile duct, cystic duct remanent, or gall blad-der fossa. Rate of complications such as migration, and instent occlusion were recorded. Failure of endoscopic therapy was defined as persistent biliary stenosis or continuous biliary leakage after 12 mo of stent placement. RESULTS: All 17 patients underwent successful FC- SEMS placement and removal. Etiologies of BBS included: cholecystectomies (n=8), cholelithiasis (n=2), hepatic artery compression (n=1), pancreatitis (n=2), and Whipple procedure (n=1). All bile leaks occurred following cholecystectomy. The anatomic location of BBS varied: distal common bile duct (n=7), common hepatic duct (n=1), hepaticojejunal anastomosis (n=2), right intrahepatic duct (n=1), and choledochoduo-denal anastomatic junction (n=1). All bile leaks were found to be at the cystic duct. Twelve of 17 patients had failed prior stent placement or exchange. Resolution of the biliary strictures and bile leaks was achieved in 16 of 17 patients (94%). The overall median stent time was 63 d (range 27-251 d). The median stent time for the BBS group and bile leak group was 62 ± 58 d (range 27-199 d) and 92 ± 81 d (range 48-251 d), respectively. All 17 patients underwent successful FCSEMS removal. Long term follow-up was obtained for a median of 575 d (range 28-1435 d). Complications occurred in 5 of 17 patients (29%) and included: migration (n=2), stent clogging (n=1), cholangitis (n=1), and sepsis with hepatic abscess (n=1). CONCLUSION: Placement of fully covered self-expanding metal stents may be used in the management of benign biliary strictures and bile leaks with a low rate of complications. 展开更多
关键词 BILE leakS Benign BILIARY STRICTURE Fully COVERED metal STENTS BILIARY disease
下载PDF
Leake计数器几何响应的研究
18
作者 谭民 陈常茂 +1 位作者 王正 闻友勤 《核技术》 CAS CSCD 北大核心 1990年第8期460-462,共3页
研究了不同吸收层结构的Leake计数器的角响应和径向微分响应,结果表明,这些响应与吸收层结构基本无关。并且径向微分响应可用公式ε(P)=(1-((P/r))~2)1/2拟合。
关键词 leake计数器 径向微分响应 方向性
下载PDF
Distinguishing between parenchymal and anastomotic leakage at duct-to-mucosa pancreatic reconstruction in pancreaticoduodenectomy 被引量:7
19
作者 Justin H Nguyen 《World Journal of Gastroenterology》 SCIE CAS CSCD 2008年第43期6648-6654,共7页
AIM: To distinguish anastomotic from parenchymal leakage at duct-to-mucosa reconstruction of the pancreatic remnant. METHODS: We reviewed the charts of 68 pancreaticoduodenectomies performed between 5/2000 and 12/20... AIM: To distinguish anastomotic from parenchymal leakage at duct-to-mucosa reconstruction of the pancreatic remnant. METHODS: We reviewed the charts of 68 pancreaticoduodenectomies performed between 5/2000 and 12/2005 with end-to-side duct-to-mucosa pancreatojejunostomy (PJ). The results of pancreatography, as well as peripancreatic drain volumes, and amylase levels were analyzed. RESULTS: Of 68 pancreatojejunostomies, 48 had no leak by pancreatography and had low-drain amylase (normal); eight had no pancreatographic leak but had elevated drain amylase (parenchymal leak); and 12 had pancreatographic leak and elevated drain amylase (anastomotic leak). Although drain volumes in the parenchymal leak group were significantly elevated at postoperative day (POD) 4, no difference was found at POD 7. Drain amylase level was not significantly different at POD 4. In contrast, at POD 7, the anastomotic-leak group had significantly elevated drain amylase level compared with normal and parenchymalleak groups (14158 + 24083 IU/L vs 89 + 139 IU/L and 1707 + 1515 IU/L, respectively, P = 0.012). CONCLUSION: For pancreatic remnant reconstruction after pancreaticoduodenectomy, a combination of pancreatogram and peripancreatic drain amylase levels can be used to distinguish between parenchymal and anastomotic leakage at pancreatic remnant reconstruction. 展开更多
关键词 Anastomotic leak Pancreatic leak PANCREATICODUODENECTOMY Pancreatogram Whipple procedure
下载PDF
Application of an Improved ISODATA Method to Pipeline Leak Detection 被引量:4
20
作者 Hu Jinqiu Zhang Laibin Wang Zhaohui Liang Wei 《Petroleum Science》 SCIE CAS CSCD 2007年第2期97-104,共8页
Increasingly serious leak problem in pipeline transportation has not only affected the operation of pipelines but also caused loss of precious resource and environmental damage. Based on the analysis of the occurrence... Increasingly serious leak problem in pipeline transportation has not only affected the operation of pipelines but also caused loss of precious resource and environmental damage. Based on the analysis of the occurrence of negative pressure waves and the unsupervised learning of pattern recognition, the Interactive Self-organizing Data Analysis Technique Algorithm (ISODATA) method was used to classify the negative pressure waves and then the states of pipelines could be determined. K L transformation was used to eliminate the correlativity of feature parameters and to reduce the dimensionality of feature vector space to speed up calculation. Experimental results validated the accuracy and practical value of this method. 展开更多
关键词 Negative pressure wave ISODATA leak detection K_L transformation
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部