Using 1-butyl-3-methyl-imidazolium bromide (BM1MBr) as the supporting electrolyte and magne- sium as the sacrificial anode, a new and highly efficient electrochemically catalytic route was devel- oped for the synthe...Using 1-butyl-3-methyl-imidazolium bromide (BM1MBr) as the supporting electrolyte and magne- sium as the sacrificial anode, a new and highly efficient electrochemically catalytic route was devel- oped for the synthesis of cyclic carbonates from epoxides and CO2. Based on the cooperative action of BMIMBr and an electrogenerated magnesium salt obtained under a N2 atmosphere, CO2 reacted with a wide range of epoxides to readily generate cyclic carbonates in moderate to excellent yields under mild conditions.展开更多
Electrogenerated chemiluminescence(electrochemiluminescence, ECL) generates species at electrode surfaces, which undergoes electron-transfer reactions and forms excited states to emit light. It has become a very power...Electrogenerated chemiluminescence(electrochemiluminescence, ECL) generates species at electrode surfaces, which undergoes electron-transfer reactions and forms excited states to emit light. It has become a very powerful analytical technique and has been widely used in such as clinical testing, biowarfare agent detection, and pharmaceutical analysis. This review focuses on the current trends of molecular recognition-based biosensing methods for pharmaceutical analysis since 2010. It introduces a background of ECL and presents the recent ECL developments in ECL immunoassay(ECLIA), immunosensors, enzyme-based biosensors, aptamer-based biosensors, and molecularly imprinted polymers(MIP)-based sensors. At last, the future perspective for these analytical methods is briefly discussed.展开更多
The purpose of this paper was to investigate the possibility of treating C. I. Reactive Blue 19 wastewater by electrochemical oxidation via electrogenerated active chlorine, using metallic oxide coatings (dimensional...The purpose of this paper was to investigate the possibility of treating C. I. Reactive Blue 19 wastewater by electrochemical oxidation via electrogenerated active chlorine, using metallic oxide coatings (dimensional stable anode, DSA) as anode. The electrolysis for the simulated wastewater was conducted at a constant current. Absorbances at 592 nm and 255 nm were measured to follow the decolorization of the dye and the degradatin of its aromatic ring. After 4 h of electrolysis under the experimental conditions: current density of 15 A·m^-2, 0.2 mol·L^-1 NaCl, 0.1 mol·L^-1 Na2SO4, 0.1 mmol·L^-1 dye, initial pH=6.4 and T=30℃, 100% decolorization of the dye and about 45% degradation of its aromatic ring were achieved, while no obvious change of total organic carbon was observed. The experimental results suggest that the decolorization of the dye and degradation of its aromatic ring were directly affected by current density, temperature, concentrations of the dye and sodium chloride, while slightly affected by initial pH and sodium sulfate concentration; the decolorization of the dye and degradation of its aromatic ring followed pseudo-first-order kinetics; and indirect electrooxidation, using electrogenerated active chlorine, predominated in the electrochemical oxidation.展开更多
A novel electrogenerated chemiluminescence(ECL)sensor for the determination of metoclopramide was developed by employing ruthenium complex as an ECL signal producer and an ordered mesoporous carbon(OMC)material as mod...A novel electrogenerated chemiluminescence(ECL)sensor for the determination of metoclopramide was developed by employing ruthenium complex as an ECL signal producer and an ordered mesoporous carbon(OMC)material as modified material.The ECL sensor was fabricated by adsorption ruthenium complex into a mixture of OMC and Nafion,which showed good electrochemical and ECL behaviors.It was found that the ECL intensity of the sensor fabricated was greatly enhanced in the presence of metoclopramide.Based on this finding,a highly sensitive and reproducible ECL method was developed for the determination of metoclopramide.The result showed that the ECL intensity was linear with the concentration of metoclopramide in the range from 1.0×10-10 to 5.0×10-7M and the detection limit was 3×10-11M.The ECL sensor exhibited a long-term stability and a fine reproducibility with relative standard deviation of 1.0 % for 1.0×10-10M metoclopramide in 18 continuous determinations.The developed method has been applied to the determination of metoclopramide in tablet samples with satisfactory results.展开更多
A simple and sensitive flow injection method is presented for the determination of histidine based on its enhancement of electrogenerated chemiluminescence (ECL) of luminol. After optimization of the experimental para...A simple and sensitive flow injection method is presented for the determination of histidine based on its enhancement of electrogenerated chemiluminescence (ECL) of luminol. After optimization of the experimental parameters, the working range for histidine was in 1.0 x 10-6 to 1.0 x 10 -3 mol/L with a detection limit (S/N = 3) of 0.56 mmol/L. The relative standard deviation was 1.6% for 11 measurements of 5 x 10 5 mol/L histidine solution. The proposed method has been successfully applied to the determination of histidine in real pharmaceutical preparation.展开更多
基金supported by the National Natural Science Foundation of China(21303053)the Open Project of State Key Laboratory of Chemical Engineering(SKLChE-14C02)~~
文摘Using 1-butyl-3-methyl-imidazolium bromide (BM1MBr) as the supporting electrolyte and magne- sium as the sacrificial anode, a new and highly efficient electrochemically catalytic route was devel- oped for the synthesis of cyclic carbonates from epoxides and CO2. Based on the cooperative action of BMIMBr and an electrogenerated magnesium salt obtained under a N2 atmosphere, CO2 reacted with a wide range of epoxides to readily generate cyclic carbonates in moderate to excellent yields under mild conditions.
文摘Electrogenerated chemiluminescence(electrochemiluminescence, ECL) generates species at electrode surfaces, which undergoes electron-transfer reactions and forms excited states to emit light. It has become a very powerful analytical technique and has been widely used in such as clinical testing, biowarfare agent detection, and pharmaceutical analysis. This review focuses on the current trends of molecular recognition-based biosensing methods for pharmaceutical analysis since 2010. It introduces a background of ECL and presents the recent ECL developments in ECL immunoassay(ECLIA), immunosensors, enzyme-based biosensors, aptamer-based biosensors, and molecularly imprinted polymers(MIP)-based sensors. At last, the future perspective for these analytical methods is briefly discussed.
文摘The purpose of this paper was to investigate the possibility of treating C. I. Reactive Blue 19 wastewater by electrochemical oxidation via electrogenerated active chlorine, using metallic oxide coatings (dimensional stable anode, DSA) as anode. The electrolysis for the simulated wastewater was conducted at a constant current. Absorbances at 592 nm and 255 nm were measured to follow the decolorization of the dye and the degradatin of its aromatic ring. After 4 h of electrolysis under the experimental conditions: current density of 15 A·m^-2, 0.2 mol·L^-1 NaCl, 0.1 mol·L^-1 Na2SO4, 0.1 mmol·L^-1 dye, initial pH=6.4 and T=30℃, 100% decolorization of the dye and about 45% degradation of its aromatic ring were achieved, while no obvious change of total organic carbon was observed. The experimental results suggest that the decolorization of the dye and degradation of its aromatic ring were directly affected by current density, temperature, concentrations of the dye and sodium chloride, while slightly affected by initial pH and sodium sulfate concentration; the decolorization of the dye and degradation of its aromatic ring followed pseudo-first-order kinetics; and indirect electrooxidation, using electrogenerated active chlorine, predominated in the electrochemical oxidation.
基金supported by the National Natural Science Foundation of China(No.20805028)
文摘A novel electrogenerated chemiluminescence(ECL)sensor for the determination of metoclopramide was developed by employing ruthenium complex as an ECL signal producer and an ordered mesoporous carbon(OMC)material as modified material.The ECL sensor was fabricated by adsorption ruthenium complex into a mixture of OMC and Nafion,which showed good electrochemical and ECL behaviors.It was found that the ECL intensity of the sensor fabricated was greatly enhanced in the presence of metoclopramide.Based on this finding,a highly sensitive and reproducible ECL method was developed for the determination of metoclopramide.The result showed that the ECL intensity was linear with the concentration of metoclopramide in the range from 1.0×10-10 to 5.0×10-7M and the detection limit was 3×10-11M.The ECL sensor exhibited a long-term stability and a fine reproducibility with relative standard deviation of 1.0 % for 1.0×10-10M metoclopramide in 18 continuous determinations.The developed method has been applied to the determination of metoclopramide in tablet samples with satisfactory results.
文摘A simple and sensitive flow injection method is presented for the determination of histidine based on its enhancement of electrogenerated chemiluminescence (ECL) of luminol. After optimization of the experimental parameters, the working range for histidine was in 1.0 x 10-6 to 1.0 x 10 -3 mol/L with a detection limit (S/N = 3) of 0.56 mmol/L. The relative standard deviation was 1.6% for 11 measurements of 5 x 10 5 mol/L histidine solution. The proposed method has been successfully applied to the determination of histidine in real pharmaceutical preparation.