期刊文献+
共找到2,346篇文章
< 1 2 118 >
每页显示 20 50 100
Lifetime measurement of the 3d^(9) ^(2)D_(3/2) metastable level in Mo^(15+)at an electron beam ion trap
1
作者 刘佳林 王银涛 +7 位作者 屠秉晟 黄良玉 司然 李冀光 张明武 傅云清 邹亚明 姚科 《Chinese Physics B》 SCIE EI CAS CSCD 2023年第10期400-404,共5页
An experimental measurement of the lifetime of 3d^(9) ^(2)D_(3/2) metastable level in Mo^(15+)is reported in this work.The Mo^(15+)ions are produced and trapped in an electron beam ion trap with a magnetic field of 0.... An experimental measurement of the lifetime of 3d^(9) ^(2)D_(3/2) metastable level in Mo^(15+)is reported in this work.The Mo^(15+)ions are produced and trapped in an electron beam ion trap with a magnetic field of 0.65 T.The decay photons emitted from 3d^(9) ^(2)D_(3/2) level are subsequently recorded via a cooled photomultiplier tube.Through meticulous scrutiny of potential systematic uncertainties affecting the measurement outcomes,we have determined the lifetime of Mo^(15+)3d^(9)2D_(3/2)metastable level to be 2.83(22)ms.The experimental result provides a clear distinguishment from existing calculations based on various theoretical approaches. 展开更多
关键词 lifetime measurement molybdenum ions metastable levels electron beam ion trap(EBIT)
下载PDF
Review of Electronic Speckle Pattern Interferometry(ESPI) for Three Dimensional Displacement Measurement 被引量:22
2
作者 YANG Lianxiang XIE Xin +2 位作者 ZHU Lianqing WU Sijin WANG Yonghong 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2014年第1期1-13,共13页
Three dimensional(3D) displacements, which can be translated further into 3D strain, are key parameters tor design, manufacturing and quality control. Using different optical setups, phase-shift methods, and algorit... Three dimensional(3D) displacements, which can be translated further into 3D strain, are key parameters tor design, manufacturing and quality control. Using different optical setups, phase-shift methods, and algorithms, several different 3D electronic speckle pattern interferometry(ESPl) systems for displacement and strain measurements have been achieved and commercialized. This paper provides a review of the recent developments in ESPI systems for 3D displacement and strain measurement. After an overview of the fundamentals of ESP! theory, temporal phase-shift, and spatial phase-shift techniques, 3D deformation measurements by the temporal phase-shift ESPI system, which is suited well for static measurement, and by the spatial phase-shift ESPI system, which is particularly useful for dynamic measurement, are discussed. For each method, the basic theory, a brief derivation and different optical layouts are presented. The state of art application, potential and limitation of the ESPI systems are shown and demonstrated. 展开更多
关键词 electronic speckle pattern interferometry(ESPI) three dimensional displacement and strain measurement static loading dynamic loading phase-shift technology
下载PDF
Comparison of Two Electronic Root Canal Length Measurement Devices: The Differences between Ratio Two Impedance Frequencies and Multi Frequencies
3
作者 Endang Suprastiwi Ratna Meidyawati 《Open Journal of Stomatology》 2014年第5期263-267,共5页
Accuracy electronic root canal length measurement devices were important for root canal treatment. Aim: To evaluate and compare accuracy of the two electronic root canal length measurement devices;two frequencies impe... Accuracy electronic root canal length measurement devices were important for root canal treatment. Aim: To evaluate and compare accuracy of the two electronic root canal length measurement devices;two frequencies impedance ratio and multi frequencies. Methods: Forty anterior teeth were sectioned on their cervical area. All samples were measured root canal length by radiographic. On the second phase, all the samples were measured by two frequencies impedance ratio and multi frequencies electronic devices. In the final phase, the teeth were split vertically and actual lengths were measured. All measurement by radiographic and electronic method was subtracted with actual length. Statistical analysis was performed using Chi-square and the Kolmogorov-Smirnov test. Results: Accuracy of the two frequencies impedance ratio 50% and multi frequencies 47.5%. No statistical significance between two frequencies impedance ratio and multi frequencies. Conclusions: There is no difference between ratio two impedance frequencies and multi frequencies. 展开更多
关键词 electronic ROOT CANAL measureMENT DEVICES
下载PDF
Measures for Administration of the Import of Mechanical and Electronic Products
4
《China's Foreign Trade》 2008年第14期64-66,共3页
The Measures for the Administration of the Import of Mechanical and Electronic' Products co-formulated by the Ministry of Commerce,the General Administration of Customs and the General Administration of Quality Su... The Measures for the Administration of the Import of Mechanical and Electronic' Products co-formulated by the Ministry of Commerce,the General Administration of Customs and the General Administration of Quality Supervision,Inspection and Quarantine,was hereby promul- gated,which entered into force as of May 1,2008. 展开更多
关键词 measures for Administration of the Import of Mechanical and electronic Products
下载PDF
ALTERABLE INTERVAL OPTICALELECTRONIC AUTOCOLLIMATION METHOD FOR STRAIGHTNESS MEASUREMENT OF PRECISION GUIDE
5
作者 Xue Zi Tan Jiubin +1 位作者 Zhao Weiqian Zhang Heng 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2005年第3期457-460,共4页
Optical-electronic autocollimation method is commonly used to measure straightness of precision guides in engineering application. However, the traditional fixed interval optical-electronic autocollimation method is n... Optical-electronic autocollimation method is commonly used to measure straightness of precision guides in engineering application. However, the traditional fixed interval optical-electronic autocollimation method is not suitable for measuring straightness of an air-bearing guide with a long air-bearing bush or a precision straight guide with a long slide-carriage, because the air-bearing bush and the slidecarriage are actually taken as a big bridgeboard bigger than the length of the bridgeboard with the reflector, which is about 1/4-1/2 of total length of the measured guide. If straightness is measured according to the traditional method, only a few points are sampled so that the guide straightness can not be evaluated fully or accurately. In order to solve the problem, an alterable measuring interval method is proposed for straightness measurement based on analyzing the mutual relations and effects among the tilting angle of the reflector, the length of the bridgeboard, the measuring interval and the straightness of the guide. A straightness calculation model is also developed using the method, and the errors stemming from the method proposed are introduced in brief. A precision air-bearing guide with a long air-bearing bush is measured and evaluated using the method proposed, and the actual measurement and evaluation results prove that the method is correct in theory and practical in operation. The method proposed gives an effective and flexible solution to the straightness measurement of the precision guide with long slide-carriage or air-bearing bush in application. It is an extension of the traditional optical-electronic autocollimation method for straightness measurement. 展开更多
关键词 Straightness measurement Optical-electronic autocollimator Alterable interval Autocollimation Air bearing guide Slide carriage
下载PDF
Design and development of multi-channel front end electronics based on dual-polarity charge-to-digital converter for SiPM detector applications 被引量:2
6
作者 Yu‑Ying Li Chang‑Yu Li Kun Hu 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2023年第2期1-12,共12页
With the development of silicon photomultiplier(SiPM)technology,front-end electronics for SiPM signal processing have been highly sought after in various fields.A compact 64-channel front-end electronics(FEE)system ac... With the development of silicon photomultiplier(SiPM)technology,front-end electronics for SiPM signal processing have been highly sought after in various fields.A compact 64-channel front-end electronics(FEE)system achieved by fieldprogrammable gate array-based charge-to-digital converter(FPGA-QDC)technology was built and developed.The FEE consists of an analog board and FPGA board.The analog board incorporates commercial amplifiers,resistors,and capacitors.The FPGA board is composed of a low-cost FPGA.The electronics performance of the FEE was evaluated in terms of noise,linearity,and uniformity.A positron emission tomography(PET)detector with three different readout configurations was designed to validate the readout capability of the FEE for SiPM-based detectors.The PET detector was made of a 15×15 lutetium–yttrium oxyorthosilicate(LYSO)crystal array directly coupled with a SiPM array detector.The experimental results show that FEE can process dual-polarity charge signals from the SiPM detectors.In addition,it shows a good energy resolution for 511-keV gamma photons under the dual-end readout for the LYSO crystal array irradiated by a Na-22 source.Overall,the FEE based on FPGA-QDC shows promise for application in SiPM-based radiation detectors. 展开更多
关键词 Readout electronics Charge measurement Radiation detector Silicon photomultiplier Field-programmable gate array
下载PDF
Measurement of time-varying electron density of the plasma generated from a small-size cylindrical RDX explosion by Rayleigh microwave scattering 被引量:1
7
作者 Hong CHEN Xuchao PAN +3 位作者 Yong HE Junjie JIAO Jie SHEN Chi BEN 《Plasma Science and Technology》 SCIE EI CAS CSCD 2021年第4期36-47,共12页
It is challenging to measure the electron density of the unsteady plasma formed by charged particles generated from explosions in the air,because it is transient and on a microsecond time scale.In this study,the time-... It is challenging to measure the electron density of the unsteady plasma formed by charged particles generated from explosions in the air,because it is transient and on a microsecond time scale.In this study,the time-varying electron density of the plasma generated from a small cylindrical cyclotrimethylenetrinitramine(RDX)explosion in air was measured,based on the principle of microwave Rayleigh scattering.It was found that the evolution of the electron density is related to the diffusion of the detonation products.The application of the Rayleigh microwave scattering principle is an attempt to estimate the electron density in explosively generated plasma.Using the equivalent radius and length of the detonation products in the bright areas of images taken by a high-speed framing camera,the electron density was determined to be of the order of 10^(20)m^(−3).The delay time between the initiation time and the start of variation in the electron-density curve was 2.77–6.93μs.In the time-varying Rayleigh microwave scattering signal curve of the explosively generated plasma,the electron density had two fluctuation processes.The durations of the first stage and the second stage were 11.32μs and 19.20μs,respectively.Both fluctuation processes increased rapidly to a peak value and then rapidly attenuated with time.This revealed the movement characteristics of the charged particles during the explosion. 展开更多
关键词 Rayleigh microwave scattering EXPLOSIVE explosively generated plasma electron density measurement
下载PDF
Measurement of Secondary Electron Energy Spectra of Polymethyl Methacrylate 被引量:1
8
作者 Ming Weng Wan Liu +2 位作者 Ming Yin Fang Wang Meng Cao 《Chinese Physics Letters》 SCIE CAS CSCD 2018年第4期108-112,共5页
We report on a novel and convenient method of measuring secondary electron spectra for insulators in a secondary electron yield measurement system with a planar grid analyzer configuration and a metal mesh probe. In t... We report on a novel and convenient method of measuring secondary electron spectra for insulators in a secondary electron yield measurement system with a planar grid analyzer configuration and a metal mesh probe. In this measurement, the planar grid is negatively biased to force some emitted secondary electrons to return to the sample surface and to neutralize charges accumulated on the sample during the previous beam irradiation. The surface potential of the sample is then measured by use of a metal mesh probe. The grid bias for neutralization corresponding to the zero surface potential is determined based on the linear relationship between the surface potential and the grid bias. Once the surface potential equals zero, the secondary electron spectra of polymethyl methacrylate(PMMA) are studied experimentally by measuring the -curve and then fitting it to Everhart's formula. The measurement results show that the peak energy and the full width at half maximum of the spectra are 4.26 eV and 14.06 eV, respectively. 展开更多
关键词 SE In measurement of Secondary electron Energy Spectra of Polymethyl Methacrylate
下载PDF
Mechanical Analysis and Measurements of a Multicomponent NbTi/Cu Superconducting Magnets Structure for the Fully Superconducting Electron Cyclotron Resonance Ion Source 被引量:1
9
作者 关明智 胡强 +6 位作者 高配峰 王省哲 杨通军 吴巍 辛灿杰 吴北民 马力祯 《Chinese Physics Letters》 SCIE CAS CSCD 2016年第5期135-139,共5页
A fully superconducting electron cyclotron resonance (ECR) ion source (SECRAL ID is currently being built in the Institute of Modern Physics, Chinese Academy of Sciences. Its key components are three superconductin... A fully superconducting electron cyclotron resonance (ECR) ion source (SECRAL ID is currently being built in the Institute of Modern Physics, Chinese Academy of Sciences. Its key components are three superconducting solenoids (Nb-Ti/Cu) and six superconducting sextupoles (Nb-Ti/Cu). Different from the conventional supercon- ducting ECR magnetic structure, the SEC17AL Ⅱ includes three superconducting solenoid coils' that are located inside the superconducting sextupoles. The SECRAL Ⅱ can significantly reduce the interaction forces between the sextupole and the solenoids, and the magnets can also be more compact in size. For this multi-component SECRAL Ⅱ generating its self field of -8 T and being often exposed to the high self field, the mechanical analysis has become the main issue to keep their stress at 〈200 MPa on coils. The analytical and experimental results in mechanics are presented in the SECRAL Ⅱ structure. To improve the accuracy and efficiency of analysis, according to the composite rule of micromechanics, the equivalent uniform windings are used to simulate the epoxy-impregnated Nb-Ti/Cu coils. In addition, using low temperature strain gauges and a wireless fast strain acquisition system, a fundamental experiment on the based on our analysis, the stresses and deformations optimized. strains developments of a sextupole is reported. Finally, for its assembly of each SECRAL Ⅱ coil will be further 展开更多
关键词 of on IS as NBTI Mechanical Analysis and measurements of a Multicomponent NbTi/Cu Superconducting Magnets Structure for the Fully Superconducting electron Cyclotron Resonance Ion Source in for Cu
下载PDF
Direct Measurements of the Electron Energy Flux versus Electron Temperature Gradient in Tokamak Discharges
10
作者 K.W.Gentle M.E.Austin P.E.Phillips 《Plasma Science and Technology》 SCIE EI CAS CSCD 2004年第1期2130-2134,共5页
Electron thermal transport is one of the most complex processes in fusionplasmas. It is generally described by a simple thermal diffusivity in transport analyses ofdischarges, but there is evidence of critical gradien... Electron thermal transport is one of the most complex processes in fusionplasmas. It is generally described by a simple thermal diffusivity in transport analyses ofdischarges, but there is evidence of critical gradient effects with moderate stiffness. By analyzingperiodic perturbations to an equilibrium, one canmeasure the variations in electron energy flux andelectron temperature gradient over the perturbation cycle, obtaining the flux as a function ofgradient over the range of parameters generated by the perturbation. Although time-dependenttransport analysis is very sensitive to noise in the input data, averaging over many cycles of aperiodic perturbation can provide data of sufficient quality. The analyses presented here are basedon the ECE temperature data with high spatial and temporal resolution and full profile coverage onDIII-D for sawteeth and modulated ECH heating. 展开更多
关键词 tokamak discharges electron energy flux electron temperature gradient direct measurements
下载PDF
Inter-stage line ratio of He- and Li-like Ti emissions for the electron temperature measurement
11
作者 李向东 王成 +1 位作者 韩申生 徐至展 《Plasma Science and Technology》 SCIE EI CAS CSCD 2005年第2期2764-2766,共3页
Under coronal conditions, the steady state rate-equations are used to calculate the inter-stage line ratios between Li-like ls22p(2P3/2)→ls22s(2S1/2) and He-like ls2p(1P1)→1s2(1S0) transitions for Ti in the electron... Under coronal conditions, the steady state rate-equations are used to calculate the inter-stage line ratios between Li-like ls22p(2P3/2)→ls22s(2S1/2) and He-like ls2p(1P1)→1s2(1S0) transitions for Ti in the electronic temperature ranges from 0.1keV to 20 keV. The results show that the temperature sensitivities are higher at the electronic temperature less than 5000 eV and the temperature sensitivities will decrease with the increase of electronic temperature. 展开更多
关键词 inter-stage line ratio electron temperature measurement Li-like ion
下载PDF
CONTAMINATION LINE METHOD AND COMPARISON OF FOIL THICKNESS MEASUREMENT METHODS IN TRANSMISSION ELECTRON MICROSCOPY
12
作者 PAN ZhenpengGuangdong Mechanical College. Guangzhou. China 《Acta Metallurgica Sinica(English Letters)》 SCIE EI CAS CSCD 1994年第3期175-178,共4页
The paper briefly introduces the Contamination Line Method for foil thickness measurement in transmission electron microscopy and compares it with four conventional methods: the convergent beam diffraction method, the... The paper briefly introduces the Contamination Line Method for foil thickness measurement in transmission electron microscopy and compares it with four conventional methods: the convergent beam diffraction method, the contamination spot method, the methods hased on characteristic X-ray emission and continuous X-ray emission on the application, aperation and accuracy etc. 展开更多
关键词 transmission electron microscopy foil thickness measurement
下载PDF
Questions on Optimization of Measurement of Total Electron Content in Ionosphere with GPS
13
作者 Arif Shafayat Mehdiyev Ramiz Ahmed Eminov +1 位作者 Hikmat Hamid Asadov Natig Hajiaga Javadov 《Positioning》 2014年第3期66-69,共4页
The analysis of existing method for calculation of total content of electrons (TEC) in ionosphere using GPS occultation method does show that due to different values of signal/noise ration in GPS signals ?and , the ne... The analysis of existing method for calculation of total content of electrons (TEC) in ionosphere using GPS occultation method does show that due to different values of signal/noise ration in GPS signals ?and , the new method of optimum measurements of relevant frequency components of TEC measured by phase and code methods should be developed. The optimum quantity of measurements of the above-mentioned frequency components is determined taking into account the limitation imposed on general number of necessary measurements. 展开更多
关键词 GPS RECEIVER IONOSPHERE OPTIMIZATION TOTAL electron Content measurements
下载PDF
Multi-channel FIR Interferometer for Electron Density Measurement on HT-7 Superconducting Tokamak
14
作者 揭银先 高翔 +2 位作者 程永飞 杨坤 童兴德 《Plasma Science and Technology》 SCIE EI CAS CSCD 2000年第1期105-109,共5页
A five-channel far-infrared (FIR) hydrogen cyanide (HCN) laser interferometer was developed to measure plasma electron density profile on the HT-7 superconducting tokamak. The principle and structure of the five-chann... A five-channel far-infrared (FIR) hydrogen cyanide (HCN) laser interferometer was developed to measure plasma electron density profile on the HT-7 superconducting tokamak. The principle and structure of the five-channel FIR laser interferometer is described. The laser source used in the interferometer was a continuous wave glow discharge HCN laser with a 3.4 m cavity length and a 100 mW power output at 337μm wavelength. The temporal resolution was 0.1 ms and the detection sensitivity was 1/12 fringe. Preliminary experimental results measured by the interferometer on HT-7 tokamak are reported. 展开更多
关键词 FIR Multi-channel FIR Interferometer for electron Density measurement on HT-7 Superconducting Tokamak HT
下载PDF
Relative Irradiance Measurement and Bonding Configurations of Amorphous Fluorinated Carbon Films Deposited by Electron Cyclotron Resonance Plasma
15
作者 叶超 康健 +1 位作者 宁兆元 程珊华 《Plasma Science and Technology》 SCIE EI CAS CSCD 2000年第5期469-474,共6页
a-C:F films are deposited by microwave electron cyclotron resonance (ECR)plasma chemical vapor deposition (CVD) using trifluoromethane (CHF3) and benzene (C6H6) as source gases at different microwave powers. The radic... a-C:F films are deposited by microwave electron cyclotron resonance (ECR)plasma chemical vapor deposition (CVD) using trifluoromethane (CHF3) and benzene (C6H6) as source gases at different microwave powers. The radicals in plasma originating from source gases dissociation are analyzed by relative irradiance measurement. The bonding configurations and binding state of a-C:F films are measured with Fourier-transformed infrared spectrometer (FTIR) and x-ray photoelectron spectroscopy (XPS). The results show that a-C:F films are mainly composed of CF radical at lower powers but of CF2 radical at higher powers. The deposition of films is related to the radicals generated in plasma and the main bonding configurations are dependent on the ratio of CF to CF2 radicals in films. 展开更多
关键词 CHF XPS cm Relative Irradiance measurement and Bonding Configurations of Amorphous Fluorinated Carbon Films Deposited by electron Cyclotron Resonance Plasma
下载PDF
The Research and Application of the Anti-Interference Techniques of Electronic Device in Power System 被引量:1
16
作者 吴维宁 张文亮 +1 位作者 吴峡 李建建 《Electricity》 2001年第4期40-43,共4页
This paper presents the study and application of the electronic device anti-interference techniques underhigh voltage and/or heavy current electro-magnetic circumstance in power system.[
关键词 electric power system electronic measurement and/or control device anti-interference measures
下载PDF
Machine Learning-Aided Data Analysis in Single-Protein Conductance Measurement with Electron Tunneling Probes
17
作者 Yuxin Yang Tao Jiang +2 位作者 Ye Tian Biaofeng Zeng Longhua Tang 《Chinese Journal of Chemistry》 SCIE CAS CSCD 2024年第1期67-72,共6页
The electrical tunneling sensors have excellent potential in the next generation of single-molecule measurement and sequencing technologies due to their high sensitivity and spatial resolution capabilities.Electrical ... The electrical tunneling sensors have excellent potential in the next generation of single-molecule measurement and sequencing technologies due to their high sensitivity and spatial resolution capabilities.Electrical tunneling signals that have been measured at a high sampling rate may provide detailed molecular information.Despite the extraordinarily large amount of data that has been gathered,it is still difficult to correlate signal transformations with molecular processes,which creates great obstacles for signal analysis.Machine learning is an effective tool for data analysis that is currently gaining more significance.It has demonstrated promising results when used to analyze data from single-molecule electrical measurements.In order to extract meaningful information from raw measurement data,we have combined intelligent machine learning with tunneling electrical signals.For the purpose of analyzing tunneling electrical signals,we investigated the clustering approach,which is a classic algorithm in machine learning.A clustering model was built that combines the advantages of hierarchical clustering and Gaussian mixture model clustering.Additionally,customized statistical algorithms were designed.It has been proven to efficiently gather molecular information and enhance the effectiveness of data analysis. 展开更多
关键词 Tunneling sensor Single-molecule measurement Machine learning Single-protein conductance Molecular electrochemistry Nanotechnology Molecular electronics
原文传递
Readout electronics for a high-resolution soft X-ray spectrometer based on silicon drift detector 被引量:3
18
作者 Er-Lei Chen Chang-Qing Feng +4 位作者 Shu-Bin Liu Chun-Feng Ye Dong-Dong Jin Jian Lian Hui-Jun Hu 《Nuclear Science and Techniques》 SCIE CAS CSCD 2017年第1期94-99,共6页
The readout electronics for a prototype soft X-ray spectrometer based on silicon drift detector(SDD),for precisely measuring the energy and arrival time of X-ray photons is presented in this paper.The system mainly co... The readout electronics for a prototype soft X-ray spectrometer based on silicon drift detector(SDD),for precisely measuring the energy and arrival time of X-ray photons is presented in this paper.The system mainly consists of two parts,i.e.,an analog electronics section(including a pre-amplifier,a signal shaper and filter,a constant fraction timing circuit,and a peak hold circuit)and a digital electronics section(including an ADC and a TDC).Test results with X-ray sources show that an energy dynamic range of 1-10 keV with an integral nonlinearity of less than 0.1%can be achieved,and the energy resolution is better than 160 eV @ 5.9 keV FWHM.Using a waveform generator,test results also indicate that time resolution of the electronics system is about 3.7 ns,which is much less than the transit time spread of SDD(<100 ns)and satisfies the requirements of future applications. 展开更多
关键词 Energy and time measurement SOFT X-ray detection Silicon DRIFT DETECTOR READOUT electronicS
下载PDF
Cubic anvil cell apparatus for high-pressure and low-temperature physical property measurements 被引量:3
19
作者 Jin-Guang Cheng Bo-Sen Wang +1 位作者 Jian-Ping Sun Yoshiya Uwatoko 《Chinese Physics B》 SCIE EI CAS CSCD 2018年第7期100-106,共7页
We will build a cubic anvil cell (CAC) apparatus for high-pressure and low-temperature physical property measurements in the synergic extreme condition user facility (SECUF). In this article, we first introduce th... We will build a cubic anvil cell (CAC) apparatus for high-pressure and low-temperature physical property measurements in the synergic extreme condition user facility (SECUF). In this article, we first introduce the operating principle, the development history, and the current status of the CAC apparatus, and subsequently describe the design plan and technical targets for the CAC in SECUF. We will demonstrate the unique advantages of CAC, i.e., excellent pressure homogeneity and large hydrostatic pressure capacity, by summarizing our recent research progresses using CAC. Finally, we conclude by providing some perspectives on the applications of CAC in the related research fields. 展开更多
关键词 cubic anvil cell high-pressure measurements temperature-pressure phase diagram strongly cor-related electron systems
下载PDF
Prototype of the readout electronics for the RICH PID detector in the STCF 被引量:2
20
作者 Bao-Lin Hou Lei Zhao +5 位作者 Jia-Jun Qin Ye-Qun Qi Jia-Ming Li Zi-Yu Yang Shu-Bin Liu Qi An 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2022年第6期148-160,共13页
The ring imaging Cherenkov(RICH) detector for particle identification(PID) is being evaluated for the future super tau-charm facility(STCF) complex. In this work, the prototype readout electronics for the RICH PID det... The ring imaging Cherenkov(RICH) detector for particle identification(PID) is being evaluated for the future super tau-charm facility(STCF) complex. In this work, the prototype readout electronics for the RICH PID detector is designed. The prototype RICH PID detector is based on a thick gas electron multiplier combined with a micromegas detector for Cherenkov light detection. Considering that there will be a large number(~ 690,000) of detector channels in future RICH detector, the readout electronics faces many challenges to precisely measuring time and charge information, such as reducing the noise,increasing density, and improving precision. The requirements of the readout electronics are explored, the downselection of the ASICs is made and thus a prototype readout electronics is designed and implemented. Tests are also conducted to evaluate the performance of the prototype readout electronics, and the results indicate that the time resolution is better than ~ 1 ns(RMS) when the input charge is greater than ~ 12 fC based on the APV25chip, while the time resolution is better than ~ 1 ns(RMS) at an input charge of over ~ 48 fC based on the AGET and STCF ASIC chips, and the equivalent noise charge is better than ~ 0.5 fC(RMS) @ 20 pF based on the three ASICs. The test results indicate that the prototype readout electronics design meets the requirement of the future RICH PID detector and thus provides a reference for future engineering. 展开更多
关键词 Readout electronics Time measurement Charge measurement RICH PID detector STCF
下载PDF
上一页 1 2 118 下一页 到第
使用帮助 返回顶部