Fatigue behaviour has important implications for engineering composite structures in sectors ranging from automotive to aerospace. Optical sensing technology displays excellent performance in these fields for monitori...Fatigue behaviour has important implications for engineering composite structures in sectors ranging from automotive to aerospace. Optical sensing technology displays excellent performance in these fields for monitoring. In this paper, temperature and residual strain during fatigue of a carbon fiber reinforced polymer(CFRP) are investigated. Four autoclaved CFRP beam specimens, with fiber Bragg grating(FBG) sensors and thermocouples embedded at selected locations, are subjected to three-point bending cyclic loading on the BOSE testing machine for fatigue testing. Thennocouples are used to measure the temperature while FBGs can sense the temperature and strain as well. Seven tests in total are conducted at different frequencies, and each test lasts for several days. From the experimental results, transient steep peaks of temperature increases (up to 2.3℃) are discovered at the beginning of the load. The following constant temperature increments are around 1.0℃, which is not relevant to frequencies from 0.1 Hz to 20 Hz and suspected due to fatigue. Residual strains of 1×10^-5-2×10^-5 during fatigue, fading away rapidly when unloading, are also reported. Embedded FBGs here are validated to sense temperature and strains in composite structures, which demonstrates promising potentials in structure monitoring fields. CFRP are verified to have an excellent performance during fatigue with low temperature increase and residual strain.展开更多
Stretchable organic light-emitting diodes(OLEDs)are important components for flexible/wearable electronics.However,the efficiency of the existing stretchable OLEDs is still much lower as compared with their rigid coun...Stretchable organic light-emitting diodes(OLEDs)are important components for flexible/wearable electronics.However,the efficiency of the existing stretchable OLEDs is still much lower as compared with their rigid counterparts,one of the main reasons being the lack of ideal flexible transparent electrodes.Herein,we propose and develop a printed embedded metal composite electrode(PEMCE)strategy that enables the fabrication of ultra-thin,highly flexible transparent electrodes with robust mechanical properties.With the flexible transparent electrodes serves as the anodes,flexible/stretchable white OLEDs have been successfully constructed,achieving a current efficiency of up to 77.4 cd A^(-1)and a maximum luminance of 34787 cd m^(-2).The current efficiency of the resulting stretchable OLEDs is the highest ever reported for flexible/stretchable white OLEDs,which is about 1.2 times higher than that of the reference rigid devices based on ITO/glass electrodes.The excellent optoelectronic properties of the printed embedded transparent electrodes and the light extraction effect of the Ag-mesh account for the significant increase in current efficiency.Remarkably,the electroluminescence performance still retains~83%of the original luminance even after bending the device 2000 cycles at a radii of~0.5 mm.More importantly,the device can withstand tensile strains of up to~100%,and even mechanical deformation of 90%tensile strain does not result in a significant loss of electroluminescence performance with current efficiency and luminance maintained at over 85%.The results confirm that the PEMCE strategy is effective for constructing ultra-flexible transparent electrodes,showing great promise for use in a variety of flexible/stretchable electronics.展开更多
文摘Fatigue behaviour has important implications for engineering composite structures in sectors ranging from automotive to aerospace. Optical sensing technology displays excellent performance in these fields for monitoring. In this paper, temperature and residual strain during fatigue of a carbon fiber reinforced polymer(CFRP) are investigated. Four autoclaved CFRP beam specimens, with fiber Bragg grating(FBG) sensors and thermocouples embedded at selected locations, are subjected to three-point bending cyclic loading on the BOSE testing machine for fatigue testing. Thennocouples are used to measure the temperature while FBGs can sense the temperature and strain as well. Seven tests in total are conducted at different frequencies, and each test lasts for several days. From the experimental results, transient steep peaks of temperature increases (up to 2.3℃) are discovered at the beginning of the load. The following constant temperature increments are around 1.0℃, which is not relevant to frequencies from 0.1 Hz to 20 Hz and suspected due to fatigue. Residual strains of 1×10^-5-2×10^-5 during fatigue, fading away rapidly when unloading, are also reported. Embedded FBGs here are validated to sense temperature and strains in composite structures, which demonstrates promising potentials in structure monitoring fields. CFRP are verified to have an excellent performance during fatigue with low temperature increase and residual strain.
基金National Natural Science Foundation of China,Grant/Award Numbers:21835003,21422402,21674050,62005126National Key Basic Research Program of China,Grant/Award Numbers:2014CB648300,2017YFB0404501+7 种基金Natural Science Foundation of Jiangsu Province,Grant/Award Numbers:BE2019120,BK20140060Program for Jiangsu Specially-Appointed Professor,Grant/Award Number:RK030STP15001Six Talent Peaks Project of Jiangsu Province,Grant/Award Number:TD-XCL-009333 Project of Jiangsu Province,Grant/Award Number:BRA2017402Leading Talent of Technological Innovation of National Ten-Thousands Talents Program of ChinaExcellent Scientific and Technological Innovative Teams of Jiangsu Higher Education Institutions,Grant/Award Number:TJ217038NUPT Scientific Foundation,Grant/Award Number:NY220152Priority Academic Program Development of Jiangsu Higher Education Institutions(PAPD)。
文摘Stretchable organic light-emitting diodes(OLEDs)are important components for flexible/wearable electronics.However,the efficiency of the existing stretchable OLEDs is still much lower as compared with their rigid counterparts,one of the main reasons being the lack of ideal flexible transparent electrodes.Herein,we propose and develop a printed embedded metal composite electrode(PEMCE)strategy that enables the fabrication of ultra-thin,highly flexible transparent electrodes with robust mechanical properties.With the flexible transparent electrodes serves as the anodes,flexible/stretchable white OLEDs have been successfully constructed,achieving a current efficiency of up to 77.4 cd A^(-1)and a maximum luminance of 34787 cd m^(-2).The current efficiency of the resulting stretchable OLEDs is the highest ever reported for flexible/stretchable white OLEDs,which is about 1.2 times higher than that of the reference rigid devices based on ITO/glass electrodes.The excellent optoelectronic properties of the printed embedded transparent electrodes and the light extraction effect of the Ag-mesh account for the significant increase in current efficiency.Remarkably,the electroluminescence performance still retains~83%of the original luminance even after bending the device 2000 cycles at a radii of~0.5 mm.More importantly,the device can withstand tensile strains of up to~100%,and even mechanical deformation of 90%tensile strain does not result in a significant loss of electroluminescence performance with current efficiency and luminance maintained at over 85%.The results confirm that the PEMCE strategy is effective for constructing ultra-flexible transparent electrodes,showing great promise for use in a variety of flexible/stretchable electronics.