Simultaneous determination of some trace metal impurities in high-purity sodium tungstate using coprecipitation and inductively coupled plasma atomic emission spectrometry 被引量:3
1
作者 MAXiaoguo KUANGTongchun LIUQianjun 《Rare Metals》 SCIE EI CAS CSCD 2004年第3期193-196,共4页
A method based on the combination of coprecipitation with inductively coupledplasma atomic emission spectrometry (ICP-AES) was developed for the determination of impurities inhigh-purity sodium tungstate. Six elements... A method based on the combination of coprecipitation with inductively coupledplasma atomic emission spectrometry (ICP-AES) was developed for the determination of impurities inhigh-purity sodium tungstate. Six elements (Co, Cu, Fe, Mn, Ni, and Pb) were coprecipitated bylanthanum hydroxide so as to be concentrated and separated from the tungsten matrix. Effects of somefactors on the recoveries of the analytes and on the residual amount of sodium tungstate wereinvestigated, and the optimum conditions for the coprecipitation were proposed. Matrix-matchingcalibration curve method was used for the analysis. It is shown that the elements mentioned abovecan be quantitatively recovered. The detection limits for Co, Cu, Fe, Mn, Ni, and Pb are 0.07, 0.4,0.2, 0.1, 0.6, and 1.3 μg·g^(-1), respectively. The recoveries vary from 92.5% to 108%, and therelative standard deviations (RSDs) are in the range of 3.1%-5.5%. 展开更多
关键词 analytical chemistry trace metal determination inductively coupled plasmaatomic emission spectrometry (ICP-AES) coprecipitation sodium tungstate
下载PDF
Determination of Nitrogen in Steel Using Optical Emission Spectrometry 被引量:3
2
作者 Cao Cheng Li Shimin +1 位作者 Jia Yunhai Yuan Pengfei 《Journal of Iron and Steel Research(International)》 SCIE EI CAS CSCD 1999年第1期48-52,共5页
The rapid quantitative analysis of nitrogen in steel with optical emission spectrometry is described.The problems about the selection of spectral line for the determination of nitrogen,the analytical conditions of nit... The rapid quantitative analysis of nitrogen in steel with optical emission spectrometry is described.The problems about the selection of spectral line for the determination of nitrogen,the analytical conditions of nitrogen,the preparation of analytical sample,the effect of co-existing element and the calibration curve of nitrogen are discussed.The analytical range of nitrogen is 0.000 5%to 0.30%,the limit of detection is 0.000 374%,the analytical time is less than 2 min(including the preparation of sample and the exciting sample for two times).Nitrogen in steel is simultaneously determined with alloy elements and acid soluble/insoluble compounds of aluminium. 展开更多
关键词 NITROGEN STEEL optical emission spectrometry
下载PDF
The determination of 52 elements in marine geological samples by an inductively coupled plasma optical emission spectrometry and an inductively coupled plasma mass spectrometry with a high-pressure closed digestion method 被引量:14
3
作者 GAO Jingjing LIU Jihua +3 位作者 LI Xianguo YAN Quanshu WANG Xiaojing WANG Hongmin 《Acta Oceanologica Sinica》 SCIE CAS CSCD 2017年第1期109-117,共9页
An improved analytical method to determine the content of 52 major, minor and trace elements in marine geological samples, using a HF-HCl-HNO_3 acid system with a high-pressure closed digestion method(HPCD), is stud... An improved analytical method to determine the content of 52 major, minor and trace elements in marine geological samples, using a HF-HCl-HNO_3 acid system with a high-pressure closed digestion method(HPCD), is studied by an inductively coupled plasma optical emission spectrometry(ICP-OES) and an inductively coupled plasma mass spectrometry(ICP-MS). The operating parameters of the instruments are optimized, and the optimal analytical parameters are determined. The influences of optical spectrum and mass spectrum interferences, digestion methods and acid systems on the analytical results are investigated. The optimal spectral lines and isotopes are chosen, and internal standard element of rhodium is selected to compensate for matrix effects and analytical signals drifting. Compared with the methods of an electric heating plate digestion and a microwave digestion, a high-pressure closed digestion method is optimized with less acid, complete digestion,less damage for digestion process. The marine geological samples are dissolved completely by a HF-HCl-HNO_3 system, the relative error(RE) for the analytical results are all less than 6.0%. The method detection limits are 2–40μg/g by the ICP-OES, and 6–80 ng/g by ICP-MS. The methods are used to determine the marine sediment reference materials(GBW07309, GBW07311, GBW07313), rock reference materials(GBW07103, GBW07104,GBW07105), and cobalt-rich crust reference materials(GBW07337, GBW07338, GBW07339), the obtained analytical results are in agreement with the certified values, and both of the relative standard deviation(RSD) and the relative error(RE) are less than 6.0%. The analytical method meets the requirements for determining 52 elements contents of bulk marine geological samples. 展开更多
关键词 marine geological sample high-pressure closed digestion method inductively coupled plasma optical emission spectrometry inductively coupled plasma mass spectrometry major element minor element trace element
下载PDF
Determination of trace elements in maifanite by outer cover electrode atomic emission spectrometry 被引量:1
4
作者 LIJianqiang LUYiqiang JIANGWei 《Rare Metals》 SCIE EI CAS CSCD 2005年第2期161-165,共5页
Maifanite is a nature medicinal stone used in many fields for long time. Theresearch on it showed that there are many trace elements in maifanite. In this paper, 36 traceelements in maifanite were determined by outer ... Maifanite is a nature medicinal stone used in many fields for long time. Theresearch on it showed that there are many trace elements in maifanite. In this paper, 36 traceelements in maifanite were determined by outer cover electrode atomic emission spectrometry, and thedetermination conditions were studied systematically. The results show that the concentrations ofelements, which are beneficial to human health, are higher, and the elements harmful to peoplehealth such as As, Cd, Hg, Cr, and Pb are tiny in maifanite. The precision and the accuracy werealso discussed. 展开更多
关键词 atomic emission spectrometry outer cover electrode DETERMINATION TRACEELEMENTS maifanite
下载PDF
Determination of Carbon by Means of Microwave Plasma Torch Atomic Emission Spectrometry
5
作者 ZHANG Han-qi YUAN Xiang-lin +1 位作者 YE Dong-mei ZHAO Xiao-jun and JIN Qin-han (Department Of Chemistry, Jilin University, Changchun, 130023)ZHU Zhi-ping(Department of Chemistry, Northeast Normal University, Changchun, 130024) 《Chemical Research in Chinese Universities》 SCIE CAS CSCD 1996年第1期32-36,共5页
The determination of carbon by means of microwave plasma torch atomic emission spectrometry(MPT-AES) was studied. Aqueous samples were introduced with a pneumatic nebulization system. The detection limit for carbon wa... The determination of carbon by means of microwave plasma torch atomic emission spectrometry(MPT-AES) was studied. Aqueous samples were introduced with a pneumatic nebulization system. The detection limit for carbon was 0. 047μg/mL.The method was applied to the analysis for tap water and results were satisfactory. 展开更多
关键词 Microwave plasma torch Atomic emission spectrometry CARBON
下载PDF
A Study on Determination of Some Trace Nonmetals by Microwave Induced Plasma Atomic Emission Spectrometry
6
作者 Zhang Jinsheng, Ye Dongmei, Zhang Hanqi and Jin Qinhan (Department of Chemistry, Jilin University, Changchun) 《Chemical Research in Chinese Universities》 SCIE CAS CSCD 1992年第1期29-30,共2页
In general, atomic emission spectrometry (AES) is an excellent technique for determination of metal elements. However, its capability of determining nonmetals has not been developed well. The major reasons are the res... In general, atomic emission spectrometry (AES) is an excellent technique for determination of metal elements. However, its capability of determining nonmetals has not been developed well. The major reasons are the resonance lines of most nonmetals lie in the vacuum ultraviolet spectral region and the ionic lines of these elements are difficult to be used because the ionization potentials of the elements are very high. And furthermore only He plasma can efficiently excit those ionic resonance lines. The practical application of HeICP-AES to determining the nonmetals is also difficult because its operating and perchace costs are very high. In contrast to HeICPAES, the costs of He microwave induced plasma (MIP)-AES are relatively low, HeMIP has a high excitation capability which can excite ionic lines of various nonmetals and the nonmetals can be determined by HeMIP-AES with a high sensitivity. 展开更多
关键词 Microwave induced plasma Atomic emission spectrometry NONMETALS
下载PDF
Studies on Combination of Flow Injection and Microwave Plasma Torch-Atomic Emission Spectrometry
7
作者 YE Dong-mei, ZHAO Jing-hong, ZHANG Han-qi and JIN Qin-han (Department of Chemistry, Jilin University, Changchun, 130023)DONG De-fan (Hebei College of Geology, Shijiazhuang, 050031) 《Chemical Research in Chinese Universities》 SCIE CAS CSCD 1993年第3期246-247,共2页
Although the flow injection(FI) as a sample introduction technique has been extensively applied to atomic spectrometry, such as ICP-AES and AAS, very little has been done so far on coupling FI to microwave plasma syst... Although the flow injection(FI) as a sample introduction technique has been extensively applied to atomic spectrometry, such as ICP-AES and AAS, very little has been done so far on coupling FI to microwave plasma systems. Gehlausen et al. determined aqueous fluorine by coupling flow injection analysis (FIA) with HeMIP 展开更多
关键词 Microwave plasma torch Flow injection Atomic emission spectrometry
下载PDF
The Diagnosis of Plasma Parameters in Surface Alloying Technique by Optical Emission Spectrometry
8
作者 付亚波 张跃飞 +4 位作者 陈强 张广秋 高原 王建忠 隗晓云 《Plasma Science and Technology》 SCIE EI CAS CSCD 2006年第4期461-463,共3页
Electron density (Ne) in a glow discharge plasma for the surface alloying technique is diagnosed by optical emission spectrometry (OES). With CH4 as the feeding gas, Ne is obtained by comparing the Hβ spectrum ac... Electron density (Ne) in a glow discharge plasma for the surface alloying technique is diagnosed by optical emission spectrometry (OES). With CH4 as the feeding gas, Ne is obtained by comparing the Hβ spectrum according to the Stark broadening effect. It is noticed that Ne varies with the working pressures (30 Pa to 70 Pa) and cathode voltages (500 V to 1000 V), respectively. Due to an abnormal glow discharge, Ne is between 1. 71 × 10^15 /cm^3 to 6.64 × 10^15 /cm^3 and increases rapidly with working gas pressures and cathode voltages. The results show that OES is a useful method to measure the plasma parameters in a surface alloying glow discharge plasma. 展开更多
关键词 surface alloying technique optical emission spectrometry electron density
下载PDF
CORRECTION OF WING INTERFERENCE WITH KALMAN FILTERING IN INDUCTIVELY COUPLED PLASMA ATOMIC EMISSION SPECTROMETRY
9
作者 Jin Fu YANG Zhe Xiu PIAO +2 位作者 Xian Jin ZENG Zhuo Yong ZHANG Xin Hai CHEN 《Chinese Chemical Letters》 SCIE CAS CSCD 1992年第3期193-196,共4页
A Kalman filter was developed for correction of wing interference in ICP-AES.Modeling wing interference theoretically instead of experimentally, the filter can compensate the shift in wavelength position in scans, and... A Kalman filter was developed for correction of wing interference in ICP-AES.Modeling wing interference theoretically instead of experimentally, the filter can compensate the shift in wavelength position in scans, and therefore reduce the effect of the interference on detection limit. 展开更多
关键词 LINE CORRECTION OF WING INTERFERENCE WITH KALMAN FILTERING IN INDUCTIVELY COUPLED PLASMA ATOMIC emission spectrometry LA
下载PDF
A sensitive and compact mercury analyzer by integrating dielectric barrier discharge induced cold vapor generation and optical emission spectrometry 被引量:1
10
作者 An-Qin Leng Yun-Fei Tian +4 位作者 Ming-Xuan Wang Li Wu Kai-Lai Xu Xian-Deng Hou Cheng-Bin Zheng 《Chinese Chemical Letters》 SCIE CAS CSCD 2017年第2期189-196,共8页
An environmentally friendly,low power consuming,sensitive and compact mercury analyzer was developed for the determination of mercury in water samples by integrating a thin film dielectric barrier discharge induced co... An environmentally friendly,low power consuming,sensitive and compact mercury analyzer was developed for the determination of mercury in water samples by integrating a thin film dielectric barrier discharge induced cold vapor reactor and a dielectric barrier discharge optical emission spectrometer into a small polymethyl methacrylate plate(10.5 cm length×8.0 cm width×1.2 cm height).Mercury cold vapor was generated when standard or sample solutions with or without formic acid were introduced to the reactor to form thin film liquid and exposed to microplasma irradiation and subsequently separated from the liquid phase for transport to the microplasma and detection of its atomic emission.Limits of detection of 0.20 μg L^-1 and 2.6 μg L^-1 were obtained for the proposed system using or not using formic acid,respectively.Compared to the conventional microplasma optical emission spectrometry used for mercury analysis,this system not only retains the good limit of detection amenable to the determination of mercury in real samples,but also reduces power consumption,eliminates the generation of hydrogen and avoids the use of toxic or unstable reductant.Method validation was demonstrated by analysis of a certified reference material of water sample and three real water samples with good spike recoveries(88-102%). 展开更多
关键词 Mercury Real time field analysis Microplasma Optical emission spectrometry Cold vapor generation Miniaturization
原文传递
Study on Monoxide Emission Spectrometry of Rare Earth Elements Ⅰ. Determination of Sm in Rare Earth Concentrate by Dual Wavelength Method
11
作者 张在整 张杰 +1 位作者 涂传鸿 柯梅生 《Journal of Rare Earths》 SCIE EI CAS CSCD 1998年第2期74-77,共4页
On the basis of investigated enhancement effect of La, Nd, Eu, and Y on Sm determination with monoxide molecular emission spectrometry, La was selected as enhancement agent and chemical interference inhibitor. In the ... On the basis of investigated enhancement effect of La, Nd, Eu, and Y on Sm determination with monoxide molecular emission spectrometry, La was selected as enhancement agent and chemical interference inhibitor. In the presence of La, dual wavelength mothod was introduced to eliminate the spectral interference on Sm by other elements. A new method was established to determine samarium in high yttrium rare earth samples with satisfactory results. 展开更多
关键词 Rare earths Lanthanum SAMARIUM Monoxide emission spectrometry Dual wavelength method
下载PDF
On Line Anion Exchange Preconcentration in Microwave Plasma Torch Atomic Emission Spectrometry
12
《Chemical Research in Chinese Universities》 SCIE CAS CSCD 1994年第1期43-44,共2页
OnLineAnionExchangePreconcentrationinMicrowavePlasmaTorchAtomicEmissionSpectrometryLIANGFeng;ZHANGHan-qiandJ... OnLineAnionExchangePreconcentrationinMicrowavePlasmaTorchAtomicEmissionSpectrometryLIANGFeng;ZHANGHan-qiandJINQin-han(Departm... 展开更多
关键词 Microwave plasma torch Atomic emission spectrometry Preconcen-tration
下载PDF
Diagnostic of capacitively coupled radio frequency plasma from electrical discharge characteristics:comparison with optical emission spectroscopy and fluid model simulation 被引量:3
13
作者 何湘 刘冲 +6 位作者 张亚春 陈建平 陈玉东 曾小军 陈秉岩 庞佳鑫 王一兵 《Plasma Science and Technology》 SCIE EI CAS CSCD 2018年第2期26-33,共8页
The capacitively coupled radio frequency(CCRF)plasma has been widely used in various fields.In some cases,it requires us to estimate the range of key plasma parameters simpler and quicker in order to understand the ... The capacitively coupled radio frequency(CCRF)plasma has been widely used in various fields.In some cases,it requires us to estimate the range of key plasma parameters simpler and quicker in order to understand the behavior in plasma.In this paper,a glass vacuum chamber and a pair of plate electrodes were designed and fabricated,using 13.56 MHz radio frequency(RF)discharge technology to ionize the working gas of Ar.This discharge was mathematically described with equivalent circuit model.The discharge voltage and current of the plasma were measured atdifferent pressures and different powers.Based on the capacitively coupled homogeneous discharge model,the equivalent circuit and the analytical formula were established.The plasma density and temperature were calculated by using the equivalent impedance principle and energy balance equation.The experimental results show that when RF discharge power is 50–300 W and pressure is 25–250 Pa,the average electron temperature is about 1.7–2.1 e V and the average electron density is about 0.5?×10^17–3.6?×10^17m^-3.Agreement was found when the results were compared to those given by optical emission spectroscopy and COMSOL simulation. 展开更多
关键词 plasma diagnostic equivalent circuit model optical emission spectrometry COMSOL simulation
下载PDF
A Perspective of Laser Sampling for Inductively Coupled Plasma-Atomic Emission Spectro metry for Rock and Mineral Analysis
14
作者 Lin Shoulin Peng ZhaofengChina University of Geosciences , Wuhan 430074 《Journal of Earth Science》 SCIE CAS CSCD 1992年第1期120-128,共9页
The development of laser sampling for optical emission spectrometry is reviewed . Advantages and limitations of pulsed laser sampling are compared with those of continuous laser sampling . A novel method of laser samp... The development of laser sampling for optical emission spectrometry is reviewed . Advantages and limitations of pulsed laser sampling are compared with those of continuous laser sampling . A novel method of laser sampling of liquid samples for inductively coupled plasma -atomic emission spectrometry has been proposed , and its analytical performance investigated.Experimental results showed that,as a method of sample introduction , laser vaporization of liquid samples enjoyed certain advantages , e.g.,much higher sensitivity, much lower detection limit and reduced sample volume , over solution nebulization . A perspective of the application of laser sampling-inductively coupled plasma - actomic emission spectrometry for rock and mineral analysis is estimated as well. 展开更多
关键词 continuous laser sampling complete laser vaporization of samples inductively coupled plasma-atomic emission spectrometry solid sample liquid sample rock and mineral analysis .
下载PDF
DeterminationofNi,Ca,Mg,CuandPbinWolframbyInductivelyCoupledPlasmaAtomicEmisionSpectrometry
15
作者 王春梅 张淑珍 《Rare Metals》 SCIE EI CAS CSCD 1997年第1期28-31,共4页
The method for the determination of Ni, Ca, Mg, Cu and Pb in wolfram wire by ICP AES was studied. Results showed that perhydrol affects the intensities of elements (Ni, Ca, Mg, Cu, Pb) and this effect can be compensa... The method for the determination of Ni, Ca, Mg, Cu and Pb in wolfram wire by ICP AES was studied. Results showed that perhydrol affects the intensities of elements (Ni, Ca, Mg, Cu, Pb) and this effect can be compensated by internal reference element. It is also showed that the stability of plasma caused by perhydrol matrix was effectively improved. The replicate experiment and recovery experiment revealed perfect precision and accuracy. Results got by two methods were just the same. 展开更多
关键词 WOLFRAM Trace elements Atomic emission spectrometry
下载PDF
Determination of Cd,Pb and Sr by Microwave Plasma Torch Atomic Emision Spectrometry Using an Electrothermal Vaporization Sample Introduction System
16
作者 ZHAO Li-wei ZHANG Han-qí +4 位作者 CAO Yan-bo YANG Wen-jun JIN Qun JIN Qin-han FU Yao 《Chemical Research in Chinese Universities》 SCIE CAS CSCD 1998年第4期22-26,共5页
IntroductionEletrothermalvaporization(ETV)asameansofsampleintroductioninmicrowavein-ducedplasma(MIP)sourcesp... IntroductionEletrothermalvaporization(ETV)asameansofsampleintroductioninmicrowavein-ducedplasma(MIP)sourcespectrometryhasbeen... 展开更多
关键词 Atomic emission spectrometry Microwave plasma torch Electrothermal vaporization
下载PDF
不同预处理方法对饲料中微量元素含量测定的影响 被引量:2
17
作者 葛亚明 宁红梅 +4 位作者 李敬玺 刘俊伟 安志兴 魏继涛 侯向红 《Animal Husbandry and Feed Science》 CAS 2009年第3期15-18,共4页
[ Objective] To study the effects of different pretreatment methods on determination of microelement in feed and thus find the best pre treatment method for each microetement, t Method] The samples (concentrated feed... [ Objective] To study the effects of different pretreatment methods on determination of microelement in feed and thus find the best pre treatment method for each microetement, t Method] The samples (concentrated feeding stuff and fodder) were pretreated through throe methods, that is, dry incineration method, HNOs HCIO, wetdecomposition method and microwave digestion method. Then the content of seven kinds of mi croelement (AI, Ca, Cu, Fe, Mn, Se and Zn) was determined by inductively coupled plasma atomic emission spectrometer (ICPAES). I Result] These three methods were all suitable for the determination of Cu, Mn and Zn in concentrated feeding stuff and the determination of Cu and Ca in fodder. The content of Cu and Ca was higher in fodder detected by HNO3 HCIO, wetdecomposition method. The microwave digestion method was suitable for the determination of AI and Ca in concentrated feeding stuff and the determination of AI, Fe, Mn and Zn in fodder. The dry incinera tion method was fit for the determination of Fe in concentrated feeding stuff. [ Condusionl The content of different microelements should be deter mined after the feed is treated with different Ioretreatment methods. 展开更多
关键词 Pretreatment methods Determination of microelements Inductively coupled plasma atomic emission spectrometry
下载PDF
Determination of wholesome elements and heavy metals in safflower(Carthamus tinctorius L.)from Xinjiang and Henan by ICP-MS/ICP-AES 被引量:9
18
作者 Ling-Han Jia Yi Liu Yu-Zhen Li 《Journal of Pharmaceutical Analysis》 SCIE CAS 2011年第2期100-103,共4页
An inductively coupled plasma mass spectrometry (ICP-MS) or inductively coupled plasma atomic emission spectrometry (ICP-AES) was developed to determine 19 elements in safflower, a traditional Chinese medicinal he... An inductively coupled plasma mass spectrometry (ICP-MS) or inductively coupled plasma atomic emission spectrometry (ICP-AES) was developed to determine 19 elements in safflower, a traditional Chinese medicinal herb from Xinjiang Autonomous Region and Henan Province of China. Totally 19 elements in safflower included heavy metals, i.e. As, Cd, Cu, Hg and Pb, and wholesome elements, i.e. Al, Ca, Co, Cr, Fe, Mg, Mn, Mo, Ni, P, Se, Sr, V and Zn. The results showed that the concentrations of heavy metals in safflower samples were both low, all of which met the national hygiene standards except for Pb in Xinjiang sample. Meanwhile, the distribution tendency of elements in the two samples was similar, which indicated that the plant might absorb given elements in a proportional way. The method can be used for the quality control of elements in safflower, and it provides a way for the determination of the contents of safflower from Xinjiang and Henan. 展开更多
关键词 inductively coupled plasma mass spectrometry inductively coupled plasma atomic emission spectrometry wholesome elements heavy metals SAFFLOWER
下载PDF
Quantitative analysis of C, Si, Mn, Ni, Cr and Cu in low-alloy steel under ambient conditions via laser-induced breakdown spectroscopy 被引量:4
19
作者 罗丹 刘英 +3 位作者 李香宇 赵珍阳 王世功 张勇 《Plasma Science and Technology》 SCIE EI CAS CSCD 2018年第7期152-158,共7页
A diode-pumped solid-state laser (DPSSL) with a high energetic stability and long service life is applied to ablate the steel samples instead of traditional Nd:YAG laser pumped by a xenon lamp, and several factors,... A diode-pumped solid-state laser (DPSSL) with a high energetic stability and long service life is applied to ablate the steel samples instead of traditional Nd:YAG laser pumped by a xenon lamp, and several factors, such as laser pulse energy, repetition rate and argon flow rate, that influence laser-induced breakdown spectroscopy (LIBS) analytical performance are investigated in detail. Under the optimal experiment conditions, the relative standard deviations for C, Si, Mn, Ni, Cr and Cu are 3.3%-8.9%, 0.9%-2.8%, 1.2%-4.1%, 1.7%-3.0%, 1.1%-3.4% and 2.5%-8.5%, respectively, with the corresponding relative errors of 1.1%-7.9%, 1.0%-6.3%, 0.4%-3.9%, 1.5%-6.3%, 1.2%-4.0% and 1.2%-6.4%. Compared with the results of the traditional spark discharge optical emission spectrometry technique, the analytical performance of LIBS is just a little inferior due to the less stable laser-induced plasma and smaller amount of ablated sample by the laser. However, the precision, detection limits and accuracy of LIBS obtained in our present work were sufficient to meet the requirements for process analysis. These technical performances of higher stability of output energy and longer service life for DPSSL, in comparison to the Q-switch laser pumped by xeon lamp, qualify it well for the real time online analysis for different industrial applications. 展开更多
关键词 laser-induced breakdown spectroscopy (LIBS) diode-pumped solid-state laser(DPSSL) optical emission spectrometry laser-induced plasma
下载PDF
Direct and Simultaneous Determination of Several Impurity Elements in Manganese Tetroxide using ICP-AES 被引量:2
20
作者 姚俊 Atakora Djak Ladislau Kékedy-Nagy 《Journal of Wuhan University of Technology(Materials Science)》 SCIE EI CAS 2006年第1期4-8,共5页
A rapid method for the determination of impurity elements, such as Zn, Ni, Co, Cr, Cu, Cd and Pb in manganese tetroxide was developed, using inductively coupled plasma atomic emission spectrometry (ICP-AES). The cri... A rapid method for the determination of impurity elements, such as Zn, Ni, Co, Cr, Cu, Cd and Pb in manganese tetroxide was developed, using inductively coupled plasma atomic emission spectrometry (ICP-AES). The critical instrumental parameters such as sample flow rate and radio frequency incident were thoroughly optimized. The effect of matrix was also examined. The sensitivity was investigated using calibration curves obtained in presence of the matrix. The obtained recoveries for Ni, Co, Cr, Cu, and Cd at the μg· g^ -1 level were satisfactory and practically independent of the matrix used for the calibration standards. The recoveries of Pb and Zn were less suffwient. The method can be applied for routine analysis and quality control purposes at μg· g^-1 level of concentration. 展开更多
关键词 manganese tetroxide impurity elements inductively coupled plasma-atomic emission spectrometry
下载PDF