期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
Method for rating energy performance of public buildings
1
作者 Jincheng XING Youli LI +2 位作者 Jihong LING Huiyang YU Liwen WANG 《Frontiers in Energy》 SCIE CSCD 2014年第3期379-385,共7页
This paper discussed a comparative study of several state-of-art methods for determining building energy consumption benchmark. A new approach, which combined the idea of "building benchmark" and "operational bench... This paper discussed a comparative study of several state-of-art methods for determining building energy consumption benchmark. A new approach, which combined the idea of "building benchmark" and "operational benchmark" in its rating system, was proposed. A case study was conducted which applied the proposed approach to benchmarking an existing office building in Tianjin. Besides, the calculation of benchmarks of the reference building model and real building model using the rating method in eQUEST was also considered. Furthermore, the simulation results of the reference building model were taken as the baseline to divide real office buildings into different energy performance grades. 展开更多
关键词 energy consumption benchmark energy efficiency benchmark energy performance level
原文传递
AI-Assisted approach for building energy and carbon footprint modeling
2
作者 Chih-Yen Chen Kok Keong Chai Ethan Lau 《Energy and AI》 2021年第3期201-208,共8页
This paper proposes an energy and carbon footprint modelling using artificial intelligence technique to assess the impact of occupant density for various types of office building.We use EnergyPlus to simulate energy c... This paper proposes an energy and carbon footprint modelling using artificial intelligence technique to assess the impact of occupant density for various types of office building.We use EnergyPlus to simulate energy con-sumption,and then estimate the related CO₂emissions based on three years(2016–2018)of Actual Meteoro-logical Year(AMY)weather data.Various occupant densities were used to evaluate the annual energy consumption and CO₂emission.In this work,a robust deep learning technique of long short-term memory(LSTM)model was established to predict the time-series energy consumption and CO₂emissions.A power exponential curve was suggested to correlate the behaviour of annual energy and CO₂emission for occupant densities range from 10 to 100 m2/person for each office building type.The results of LSTM model show high prediction performance and small variations within the three types of office building data,which can be applied to the similar building model to predict and optimise energy consumption and CO₂emission. 展开更多
关键词 Building energy simulation and benchmarking Carbon footprint Occupant density Artificial intelligence Long short-term memory(LSTM) Smart city
原文传递
Islands of misfit buildings: Detecting uncharacteristic electricity use behavior using load shape clustering 被引量:1
3
作者 Matias Quintana Pandarasamy Arjunan Clayton Miller 《Building Simulation》 SCIE EI CSCD 2021年第1期119-130,共12页
Many energy performance analysis methodologies assign buildings a descriptive label that represents their main activity,often known as the primary space usage(PSU).This attribute comes from the intent of the design te... Many energy performance analysis methodologies assign buildings a descriptive label that represents their main activity,often known as the primary space usage(PSU).This attribute comes from the intent of the design team based on assumptions of how the majority of the spaces in the building will be used.In reality,the way a building’s occupants use the spaces can be different than what was intended.With the recent growth of hourly electricity meter data from the built environment,there is the opportunity to create unsupervised methods to analyze electricity consumption behavior to understand whether the PSU assigned is accurate.Misclassification or oversimplification of the use of the building is possible using these labels when applied to simulation inputs or benchmarking processes.To work towards accurate characterization of a building’s utilization,we propose a modular methodology for identifying potentially mislabeled buildings using distance-based clustering analysis based on hourly electricity consumption data.This method seeks to segment buildings according to their daily behavior and predict which ones are misfits according to their assigned PSU label.This process finds potentially uncharacteristic behavior that could be an indication of mixed-use or a misclassified PSU.Our results on two public data sets,from the Building Data Genome(BDG)Project and Washington DC(DGS),with 507 and 322 buildings respectively,show that 26%and 33%of these buildings are potentially mislabelled based on their load shape behavior.Such information provides a more realistic insight into their true consumption characteristics,enabling more accurate simulation scenarios.Applications of this process and a discussion of limitations and reproducibility are included. 展开更多
关键词 uncharasteristic behaviour building energy use building energy benchmarking building performance rating primary-use-type analysis load profile clustering
原文传递