Two single-storey single-span reinforcement concrete (RC) frame structures strengthened with Y-eccentrically brace were designed and manufactured to be 1/3 scale. The pseudo-dynamic testing method was used to study ...Two single-storey single-span reinforcement concrete (RC) frame structures strengthened with Y-eccentrically brace were designed and manufactured to be 1/3 scale. The pseudo-dynamic testing method was used to study the mechanical characteristics and the seismic performance under E1-Centro earthquake action with different peak acceleration adjusted by China's Code for Seismic Design of Buildings. The test results indicate that RC frame structures strengthened with Y- eccentrically steel brace present perfect seismic performance under strong earthquake action owing to the good ductility, strong bearing capability and fine energy absorbing capability provided by energy dissipation element and high lateral stiffness provided by diagonal braces. The seismic performance is also affected by the length of outsourcing steel at the joint between energy dissipation element of eccentric steel brace and RC frame beam. The joint should be considerably designed to make sure that shear failure can firstly occur in energy dissipation element.展开更多
A series of numerical tests was conducted to study the micromechanical properties and energy dissipation in polydisperse assemblies of spherical particles subjected to uniaxial compression. In general, distributed par...A series of numerical tests was conducted to study the micromechanical properties and energy dissipation in polydisperse assemblies of spherical particles subjected to uniaxial compression. In general, distributed particle size assemblies with standard deviations ranging from 0% to 80% of the particle mean diameter were examined. The microscale analyses included the trace of the fabric tensor, magnitude and orien- tation of the contact forces, trace of stress, number of contacts and degree of mobilization of friction in contacts between particles. In polydisperse samples, the average coordination numbers were lower than in monodisperse assemblies, and the mobilization of friction was higher than in monodisperse assemblies due to the non-uniform spatial rearrangement of spheres in the samples and the smaller displacements of the particles. The effect of particle size heterogeneity on both the energy density and energy dissipation in systems was also investigated.展开更多
基金Funded by National Natural Science Foundation of China (Grant No. 51078248)the Priority Academic Program Development of Jiangsu Higher Education Institutions (PAPD)
文摘Two single-storey single-span reinforcement concrete (RC) frame structures strengthened with Y-eccentrically brace were designed and manufactured to be 1/3 scale. The pseudo-dynamic testing method was used to study the mechanical characteristics and the seismic performance under E1-Centro earthquake action with different peak acceleration adjusted by China's Code for Seismic Design of Buildings. The test results indicate that RC frame structures strengthened with Y- eccentrically steel brace present perfect seismic performance under strong earthquake action owing to the good ductility, strong bearing capability and fine energy absorbing capability provided by energy dissipation element and high lateral stiffness provided by diagonal braces. The seismic performance is also affected by the length of outsourcing steel at the joint between energy dissipation element of eccentric steel brace and RC frame beam. The joint should be considerably designed to make sure that shear failure can firstly occur in energy dissipation element.
文摘A series of numerical tests was conducted to study the micromechanical properties and energy dissipation in polydisperse assemblies of spherical particles subjected to uniaxial compression. In general, distributed particle size assemblies with standard deviations ranging from 0% to 80% of the particle mean diameter were examined. The microscale analyses included the trace of the fabric tensor, magnitude and orien- tation of the contact forces, trace of stress, number of contacts and degree of mobilization of friction in contacts between particles. In polydisperse samples, the average coordination numbers were lower than in monodisperse assemblies, and the mobilization of friction was higher than in monodisperse assemblies due to the non-uniform spatial rearrangement of spheres in the samples and the smaller displacements of the particles. The effect of particle size heterogeneity on both the energy density and energy dissipation in systems was also investigated.