Reinforcement Learning Model for Energy System Management to Ensure Energy Efficiency and Comfort in Buildings
1
作者 Inna Bilous Dmytro Biriukov +3 位作者 Dmytro Karpenko Tatiana Eutukhova Oleksandr Novoseltsev Volodymyr Voloshchuk 《Energy Engineering》 EI 2024年第12期3617-3634,共18页
This article focuses on the challenges ofmodeling energy supply systems for buildings,encompassing both methods and tools for simulating thermal regimes and engineering systems within buildings.Enhancing the comfort o... This article focuses on the challenges ofmodeling energy supply systems for buildings,encompassing both methods and tools for simulating thermal regimes and engineering systems within buildings.Enhancing the comfort of living or working in buildings often necessitates increased consumption of energy and material,such as for thermal upgrades,which consequently incurs additional economic costs.It is crucial to acknowledge that such improvements do not always lead to a decrease in total pollutant emissions,considering emissions across all stages of production and usage of energy and materials aimed at boosting energy efficiency and comfort in buildings.In addition,it explores the methods and mechanisms for modeling the operating modes of electric boilers used to collectively improve energy efficiency and indoor climatic conditions.Using the developed mathematical models,the study examines the dynamic states of building energy supply systems and provides recommendations for improving their efficiency.These dynamic models are executed in software environments such as MATLAB/Simscape and Python,where the component detailing schemes for various types of controllers are demonstrated.Additionally,controllers based on reinforcement learning(RL)displayed more adaptive load level management.These RL-based controllers can lower instantaneous power usage by up to 35%,reduce absolute deviations from a comfortable temperature nearly by half,and cut down energy consumption by approximately 1%while maintaining comfort.When the energy source produces a constant energy amount,the RL-based heat controllermore effectively maintains the temperature within the set range,preventing overheating.In conclusion,the introduced energydynamic building model and its software implementation offer a versatile tool for researchers,enabling the simulation of various energy supply systems to achieve optimal energy efficiency and indoor climate control in buildings. 展开更多
关键词 building energy management building heating system dynamic modeling reinforcement learning energy efficiency comfortable temperature
下载PDF
eQUEST Based Building Energy Modeling Analysis for Energy Efficiency of Buildings
2
作者 Saroj Lamichhane Roseline Mostafa +1 位作者 Bhaskaran Gopalakrishnan Dayakar G.Devaru 《Energy Engineering》 EI 2024年第10期2743-2767,共25页
Building energy performance is a function of numerous building parameters.In this study,sensitivity analysis on twenty parameters is performed to determine the top three parameters that have the most significant impac... Building energy performance is a function of numerous building parameters.In this study,sensitivity analysis on twenty parameters is performed to determine the top three parameters that have the most significant impact on the energy performance of buildings.Actual data from two fully operational commercial buildings were collected and used to develop a building energy model in the Quick Energy Simulation Tool(eQUEST).The model is calibrated using the Normalized Mean Bias Error(NMBE)and Coefficient of Variation of Root Mean Square Error(CV(RMSE))method.The model satisfies the NMBE and CV(RMSE)criteria set by the American Society of Heating,Refrigeration,and Air-Conditioning(ASHRAE)Guideline 14,Federal Energy Management Program(FEMP),and International Performance Measurement and Verification Protocol(IPMVP)for building energy model calibration.The values of the parameters are varied in two levels,and then the percentage change in output is calculated.Fractional factorial analysis on eight parameters with the highest percentage change in energy performance is performed at two levels in a statistical software JMP.For building A,the top 3 parameters from the percentage change method are:Heating setpoint,cooling setpoint and server room.From fractional factorial design,the top 3 parameters are:heating setpoint(p-value=0.00129),cooling setpoint(p-value=0.00133),and setback control(p-value=0.00317).For building B,the top 3 parameters from both methods are:Server room(pvalue=0.0000),heating setpoint(p-value=0.00014),and cooling setpoint(p-value=0.00035).If the best values for all top three parameters are taken simultaneously,energy efficiency improves by 29%for building A and 35%for building B. 展开更多
关键词 energy efficiency EQUEST energy consumption building energy modeling
下载PDF
Effect of building energy efficiency standards on carbon emission efficiency in commercial buildings
3
作者 Xia Wang Qi Ye +1 位作者 Yan Du Mao Zhou 《Chinese Journal of Population,Resources and Environment》 2024年第3期250-257,共8页
The building sector plays a crucial role in the worldwide shift toward achieving net-zero emissions.Building energy efficiency standards(BEESs)are highly effective policies for reducing carbon emissions.Therefore,expl... The building sector plays a crucial role in the worldwide shift toward achieving net-zero emissions.Building energy efficiency standards(BEESs)are highly effective policies for reducing carbon emissions.Therefore,exploring the provincial variations in carbon emission efficiency(CEE)in the building sector and identifying the effect of BEESs on CEE is crucial.This study focuses on commercial buildings in China and applies a difference in differences model to evaluate the impact of BEESs on the CEE of commercial buildings.The slacks-based measure–data envelopment analysis model is employed to assess the CEE of commercial buildings in 30 Chinese provinces from 2000 to 2019.Furthermore,heterogeneous tests are used to explore how climate characteristics and economic conditions affect the efficiency of BEESs.The results indicate that BEESs positively influence the CEE of commercial buildings.Specifically,a 1%increase in the intensity of BEESs causes a 0.1484%increase in the CEE of commercial buildings.Moreover,the impact of BEESs is particularly pronounced in the southern and western provinces.This study provides valuable scientific evidence for governments to enhance BEESs implementation. 展开更多
关键词 Commercial buildings Carbon emissions efficiency building energy efficiency standards Slack-based measure–data development analysis Difference in differences
下载PDF
Low-Cost Insulation for Energy Efficient Buildings in Terai Region of Nepal
4
作者 Abhishek Karn 《Journal of Civil Engineering and Architecture》 2024年第1期38-50,共13页
There is a huge amount of energy savings potential in public building sector that has yet to be realized.By prioritizing energy efficiency in its own buildings and thus promoting the development of required knowledge ... There is a huge amount of energy savings potential in public building sector that has yet to be realized.By prioritizing energy efficiency in its own buildings and thus promoting the development of required knowledge in terms of new technology and construction methods,the public sector will lead the way in efforts to increase the rate of renovations.The low-cost insulation strategies and a comparison of cost with existing insulation materials has been described in this study.We have repeatedly faced energy crises and will continue to do so in the future if appropriate action is not taken in a timely manner.Properly implementing energy-saving initiatives in for achieving thermal comfort in buildings as well as reducing the energy costs would undoubtedly inspire the residential sector,resulting in significant reductions in energy usage.Simulations were carried out to study insulation layers on various building components like exterior walls,floor and roofs,generating different scenarios for a building as a base model,which were then compared and analysed to verify the literature used to develop the cases.The proposed recommendations,which have been validated,are certain to increase building energy efficiency,achieve thermal comfort in low cost than what is currently being used. 展开更多
关键词 buildings energy energy efficient thermal comfort
下载PDF
Benchmarking of energy efficiency standards for residential buildings in China
5
作者 陈华 李慧玲 《Journal of Southeast University(English Edition)》 EI CAS 2010年第2期151-155,共5页
In order to benchmark the energy efficiency standards for residential buildings in China,the Hong Kong building environment assessment method(HK-BEAM)is chosen as the compliance criteria for assessment.The annual en... In order to benchmark the energy efficiency standards for residential buildings in China,the Hong Kong building environment assessment method(HK-BEAM)is chosen as the compliance criteria for assessment.The annual energy consumption and the overall thermal transfer value(OTTV)of a baseline residential building prescribed in the Chinese codes and the HK-BEAM are evaluated and compared by the energy budget approach.The results show that in the Chinese codes,the OTTV of the residential building is lower,but the annual energy consumption and the cooling load are higher than those in the HK-BEAM.The annual energy use difference amounts to 13.4%.All the compliance criteria except the ventilation rate and the equipment power in the Chinese codes are set higher than those in the HK-BEAM.However,the compliance criteria of the ventilation rate and the equipment power,especially the ventilation rate,result in much energy consumption,which ultimately induces a high energy budget for residential buildings. 展开更多
关键词 Chinese energy efficiency code Hong Kong building environment assessment method(HK-BEAM) energy budget approach residential buildings
下载PDF
Optimum Energy Management of the Central Air-Conditioning System in Intelligent Buildings
6
作者 郭巧 徐庆伟 《Journal of Beijing Institute of Technology》 EI CAS 2002年第3期298-301,共4页
An optimum energy saving scheduling strategy of the central air conditioning system in an intelligent building (IB) was proposed. Based on the system analysis a set of models of the central air conditioning system w... An optimum energy saving scheduling strategy of the central air conditioning system in an intelligent building (IB) was proposed. Based on the system analysis a set of models of the central air conditioning system was established. The periodically autoregressive models (PARM) based on genetic algorithms (GA) were used to predict the next day’s cold load. The improved genetic algorithms (IGA) with stochastic real number coding were used to finish the optimum energy saving scheduling of the system. The simulation results for the building of the Liangmahe Plaza show that the proposed strategy can save energy up to about 24 5%. 展开更多
关键词 intelligent building genetic algorithms central air conditioning energy saving
下载PDF
Analyses of influence of residential buildings' space organization on heating energy consumption in Lhasa 被引量:7
7
作者 Li En 《Journal of Southeast University(English Edition)》 EI CAS 2017年第4期457-465,共9页
The heating load simulation models of the residential buildings in Lhasa are established for enhancing the space organization’s adaptability to climate and radiation and improving its energy saving performance.The sp... The heating load simulation models of the residential buildings in Lhasa are established for enhancing the space organization’s adaptability to climate and radiation and improving its energy saving performance.The space organization items a e analyzed for both the existing buildings without insulation and new buildings with good insulation.The items include orientation design,south a d north balcony design,the north and south partition wall’s position design,storey height design and window-wall ratio design.Simulation results show that orientation is the key design element for energy saving design,and adverse orientation can obviouslyincrease heating energy consumption;south and north balconies can reduce winter heating energy consumption;partition walls move to the north,which means that the south room’s big depth design leads to less heating energy consumption,but the effect is not inconspicuous;smaier storey height results in less heating load.For the existing buildings,the window-wall ratio of south side has a balance point for energy saving design in the calculation condition.For the new buildings with good insulation,enlarging the south window-wal ratio can continuously reduce heating energy consumption,but the energy saving rate between models gets smaier.The heating energy consumption comparison study between the common model and optimal space design model demonstrates that the energy saving design can significantly reduce heating energy consumption 展开更多
关键词 residential building space organization heating energy consumption energy saving design
下载PDF
Role of outdoor trees on pedestrian wind and thermal conditions around a pre-education building for sustainable energy management
8
作者 LI Xiao-jie TANG Hui-li 《Journal of Central South University》 SCIE EI CAS CSCD 2024年第6期2039-2053,共15页
Finding sustainable energy resources is essential to face the increasing energy demand.Trees are an important part of ancient architecture but are becoming rare in urban areas.Trees can control and tune the pedestrian... Finding sustainable energy resources is essential to face the increasing energy demand.Trees are an important part of ancient architecture but are becoming rare in urban areas.Trees can control and tune the pedestrian-level wind velocity and thermal condition.In this study,a numerical investigation is employed to assess the role of trees planted in the windward direction of the building complex on the thermal and pedestrian wind velocity conditions around/inside a pre-education building located in the center of the complex.Compared to the previous studies(which considered only outside buildings),this work considers the effects of trees on microclimate change both inside/outside buildings.Effects of different parameters including the leaf area density and number of trees,number of rows,far-field velocity magnitude,and thermal condition around the main building are assessed.The results show that the flow velocity in the spacing between the first-row buildings is reduced by 30%-40% when the one-row trees with 2 m height are planted 15 m farther than the buildings.Furthermore,two rows of trees are more effective in higher velocities and reduce the maximum velocity by about 50%.The investigation shows that trees also could reduce the temperature by about 1℃around the building. 展开更多
关键词 sustainable management energy trees urban area thermal condition building
下载PDF
A New Dynamic and Vertical Photovoltaic Integrated Building Envelope for High-Rise Glaze-Facade Buildings
9
作者 Wuwei Zou Yan Wang +3 位作者 Enze Tian Jiaze Wei Jinqing Peng Jinhan Mo 《Engineering》 SCIE EI CAS CSCD 2024年第8期194-203,共10页
Substantially glazed facades are extensively used in contemporary high-rise buildings to achieve attractive architectural aesthetics.Inherent conflicts exist among architectural aesthetics,building energy consumption,... Substantially glazed facades are extensively used in contemporary high-rise buildings to achieve attractive architectural aesthetics.Inherent conflicts exist among architectural aesthetics,building energy consumption,and solar energy harvesting for glazed facades.In this study,we addressed these conflicts by introducing a new dynamic and vertical photovoltaic integrated building envelope(dvPVBE)that offers extraordinary flexibility with weather-responsive slat angles and blind positions,superior architectural aesthetics,and notable energy-saving potential.Three hierarchical control strategies were proposed for different scenarios of the dvPVBE:power generation priority(PGP),natural daylight priority(NDP),and energy-saving priority(ESP).Moreover,the PGP and ESP strategies were further analyzed in the simulation of a dvPVBE.An office room integrated with a dvPVBE was modeled using EnergyPlus.The influence of the dvPVBE in improving the building energy efficiency and corresponding optimal slat angles was investigated under the PGP and ESP control strategies.The results indicate that the application of dvPVBEs in Beijing can provide up to 131%of the annual energy demand of office rooms and significantly increase the annual net energy output by at least 226%compared with static photovoltaic(PV)blinds.The concept of this novel dvPVBE offers a viable approach by which the thermal load,daylight penetration,and energy generation can be effectively regulated. 展开更多
关键词 Weather-responsive facades building energy efficiency Dynamic photovoltaic integrated building envelopes(PVBEs) building-integrated photovoltaics(BIPVs)
下载PDF
Energy consumption prediction model of typical buildings in hot summer and cold winter zone of China 被引量:1
10
作者 Xu Jianqun Zhang Fang +2 位作者 Chen Feixiang Huang Xijun Sun Jian 《Journal of Southeast University(English Edition)》 EI CAS 2017年第3期348-354,共7页
To overcome the shortcomings of the energyconsumption prediction models in the application during thedesign stage, a quick prediction model for energy consumptionis proposed based on the decoupling method. Taking typi... To overcome the shortcomings of the energyconsumption prediction models in the application during thedesign stage, a quick prediction model for energy consumptionis proposed based on the decoupling method. Taking typicalresidential and office buildings in hot summer and cold winterzones as research objects, the influence factors on buildingenergy consumption are classified into intrinsic factors andoperational factors on the basis of the heat transfer principle.Then, using the intrinsic factors as the fundamental variablesand operational factors as the modified variables, the quickprediction model for the buildings in typical cold and hot zonesis proposed based on the decoupling method and the accuracyof the proposed model is verified. The results show thatcompared to the simulation results of EnergyPlus, the relativeerror of the prediction model is less than 1.5% ; comparedwith the real operating data of the building, the relative erroris 13.14% in 2011 and 8.56% in 2012 due to the fact that thecoincidence factor becomes larger than the design value about16% in 2011 and 13% in 2012. The finding reveals that theproposed model has the advantages of rapid calculationcompared with EnergyPlus and Design Builder when predictingbuilding energy consumption in building designs. The energyconsumption prediction model is of great practical value inoptimal operation and building designs. 展开更多
关键词 building energy CONSUMPTION energy CONSERVATION LOAD PREDICTION energyPLUS
下载PDF
Energy-Efficient and Cost-Effective Approaches through Energy Modeling for Hotel Building
11
作者 Alya Penta Agharid Indra Permana +2 位作者 Nitesh Singh Fujen Wang Susan Gustiyana 《Energy Engineering》 EI 2024年第12期3549-3571,共23页
Hotel buildings are currently among the largest energy consumers in the world.Heating,ventilation,and air conditioning are the most energy-intensive building systems,accounting for more than half of total energy consu... Hotel buildings are currently among the largest energy consumers in the world.Heating,ventilation,and air conditioning are the most energy-intensive building systems,accounting for more than half of total energy consumption.An energy audit is used to predict the weak points of a building’s energy use system.Various factors influence building energy consumption,which can be modified to achieve more energy-efficient strategies.In this study,an existing hotel building in Central Taiwan is evaluated by simulating several scenarios using energy modeling over a year.Energy modeling is conducted by using Autodesk Revit 2025.It was discovered from the results that arranging the lighting schedule based on the ASHRAE Standard 90.1 could save up to 8.22%of energy consumption.And then the results also revealed that changing the glazing of the building into double-layer lowemissivity glass could reduce energy consumption by 14.58%.While the energy consumption of the building could also be decreased to 7.20%by changing the building orientation to the north.Meanwhile,moving the building location to Northern Taiwan could also minimize the energy consumption of the building by 3.23%.The results revealed that the double layer offers better thermal insulation,and low-emissivity glass can lower energy consumption,electricity costs,and CO_(2)emissions by up to 15.27%annually.While adjusting orientation and location can enhance energy performance,this approach is impractical for existing buildings,but this could be considered for designing new buildings.The results showed the relevancy of energy performance to CO_(2)emission production and electricity expenses. 展开更多
关键词 energy-EFFICIENT energy modeling field measurement energy saving hotel building
下载PDF
Modeling and optimization of a multi-carrier renewable energy system for zero-energy consumption buildings 被引量:7
12
作者 SOULEY AGBODJAN Yawovi LIU Zhi-qiang +2 位作者 WANG Jia-qiang YUE Chang LUO Zheng-yi 《Journal of Central South University》 SCIE EI CAS CSCD 2022年第7期2330-2345,共16页
For the carbon-neutral,a multi-carrier renewable energy system(MRES),driven by the wind,solar and geothermal,was considered as an effective solution to mitigate CO2emissions and reduce energy usage in the building sec... For the carbon-neutral,a multi-carrier renewable energy system(MRES),driven by the wind,solar and geothermal,was considered as an effective solution to mitigate CO2emissions and reduce energy usage in the building sector.A proper sizing method was essential for achieving the desired 100%renewable energy system of resources.This paper presented a bi-objective optimization formulation for sizing the MRES using a constrained genetic algorithm(GA)coupled with the loss of power supply probability(LPSP)method to achieve the minimal cost of the system and the reliability of the system to the load real time requirement.An optimization App has been developed in MATLAB environment to offer a user-friendly interface and output the optimized design parameters when given the load demand.A case study of a swimming pool building was used to demonstrate the process of the proposed design method.Compared to the conventional distributed energy system,the MRES is feasible with a lower annual total cost(ATC).Additionally,the ATC decreases as the power supply reliability of the renewable system decreases.There is a decrease of 24%of the annual total cost when the power supply probability is equal to 8%compared to the baseline case with 0%power supply probability. 展开更多
关键词 multi-carrier renewable energy system constrained genetic algorithm loss of power supply probability(LPSP)method zero-energy consumption building optimal device capacity
下载PDF
Energy consumption,indoor environmental quality,and benchmark for office buildings in Hainan Province of China 被引量:1
13
作者 孔祥飞 吕石磊 +1 位作者 辛亚娟 吴薇 《Journal of Central South University》 SCIE EI CAS 2012年第3期783-790,共8页
With rapid economy growth,building energy consumption in China has been gradually increased.The energy consumption and indoor environmental quality of 51 office buildings in Hainan Province,a hot and humid area,were s... With rapid economy growth,building energy consumption in China has been gradually increased.The energy consumption and indoor environmental quality of 51 office buildings in Hainan Province,a hot and humid area,were studied through collection of verified data in site visits and field tests.The result revealed that,electricity accounted for 99.79% of the total energy consumption,natural gas 0.17%,and diesel 0.04%.The air conditioning dominated the energy use with a share of 43.18%,equipment in the particular areas 26.90%,equipment in the office rooms 11.95%,lighting system 8.67%,general service system 7.57%,and miscellaneous items 1.73%.Statistical method including six indicators obtained the energy consumption benchmark with upper limit of 98.31 kW-h/m2 and lower limit of 55.26 kW-h/m2.According to ASHRAE standard(comfortable standard) and GB/T 18883-2002(acceptable standard),the indoor environmental quality of 51 sampled office buildings was classified into three ranks:good,normal and bad.With benchmark of building energy consumption combined with indoor environmental quality,it was found that only 3.92% of sampled buildings can be identified as the best performance buildings with low energy consumption and advanced indoor environmental quality,and the buildings classified into normal level accounted for the maximum ratio. 展开更多
关键词 building energy consumption BENCHMARK indoor environmental quality energy use index Hainan Province
下载PDF
Multi-Time Scale Optimal Scheduling of a Photovoltaic Energy Storage Building System Based on Model Predictive Control
14
作者 Ximin Cao Xinglong Chen +2 位作者 He Huang Yanchi Zhang Qifan Huang 《Energy Engineering》 EI 2024年第4期1067-1089,共23页
Building emission reduction is an important way to achieve China’s carbon peaking and carbon neutrality goals.Aiming at the problem of low carbon economic operation of a photovoltaic energy storage building system,a ... Building emission reduction is an important way to achieve China’s carbon peaking and carbon neutrality goals.Aiming at the problem of low carbon economic operation of a photovoltaic energy storage building system,a multi-time scale optimal scheduling strategy based on model predictive control(MPC)is proposed under the consideration of load optimization.First,load optimization is achieved by controlling the charging time of electric vehicles as well as adjusting the air conditioning operation temperature,and the photovoltaic energy storage building system model is constructed to propose a day-ahead scheduling strategy with the lowest daily operation cost.Second,considering inter-day to intra-day source-load prediction error,an intraday rolling optimal scheduling strategy based on MPC is proposed that dynamically corrects the day-ahead dispatch results to stabilize system power fluctuations and promote photovoltaic consumption.Finally,taking an office building on a summer work day as an example,the effectiveness of the proposed scheduling strategy is verified.The results of the example show that the strategy reduces the total operating cost of the photovoltaic energy storage building system by 17.11%,improves the carbon emission reduction by 7.99%,and the photovoltaic consumption rate reaches 98.57%,improving the system’s low-carbon and economic performance. 展开更多
关键词 Load optimization model predictive control multi-time scale optimal scheduling photovoltaic consumption photovoltaic energy storage building
下载PDF
Energy Consumption Monitoring Analysis for Residential, Educational and Public Buildings 被引量:1
15
作者 Allan Hani Teet-Andrus Koiv 《Smart Grid and Renewable Energy》 2012年第3期231-238,共8页
In the present article thermal and electrical energy consumptions for different types of buildings are analyzed. The latitude and longitude of the researched area are defined 59?00'N and 26?00'E. According to ... In the present article thermal and electrical energy consumptions for different types of buildings are analyzed. The latitude and longitude of the researched area are defined 59?00'N and 26?00'E. According to K?ppen climate classification the area is located in warm summer continental climate. The study consist 40 residential, 7 educational and 44 public buildings. Three years data for each building type among 2006-2011 was used. Several detailed energy balances are presented for apartment buildings. In addition the different ways of domestic hot water preparation are analyzed for apartment buildings. The school buildings average consumption values are represented in study. Also valuable information of measured electrical energy consumption balance for a new office building is presented. Finally there is included the energy consumption analysis of public buildings. 展开更多
关键词 Specific energy CONSUMPTION Thermal energy Electrical energy RESIDENTIAL buildings EDUCATIONAL buildings OFFICE buildings
下载PDF
Enhanced Thermal Performance of Roofing Materials by Integrating Phase Change Materials to Reduce Energy Consumption in Buildings 被引量:1
16
作者 Chanita Mano Atthakorn Thongtha 《Journal of Renewable Materials》 SCIE EI 2021年第3期495-506,共12页
This work focused on characterizing and improving the thermal behavior of metal sheet roofing.To decrease the heat transfer from the roof into a building,we investigated the efficiency of four types of phase change ma... This work focused on characterizing and improving the thermal behavior of metal sheet roofing.To decrease the heat transfer from the roof into a building,we investigated the efficiency of four types of phase change materials,with different melting points:PCMІ,PCM II,PCM III and PCM IV,when used in conjunction with a sheet metal roof.The exterior metal roofing surface temperature was held constant at 50℃,60℃,70℃and 80℃,using a thermal source(halogen lights)for 360 min to investigate and compare the thermal performance of the metal sheet roofing with and without phase change materials for each condition.The thermal behaviors of the phase change materials were analyzed by differential scanning calorimeter(DSC).The results showed the melting points of PCMІ,PCM II,PCM III and PCM IV were around 45℃,50℃,55℃and 59℃,respectively.The integration of PCM IV into the metal roofing sheet increased the thermal performance by reducing the room temperature up to 2.8%,1.4%,1.0%and 0.7%when compared with the normal metal roof sheet,at the controlled temperatures of 50℃,60℃,70℃and 80℃,respectively.The thermal absorption of the phase change materials also caused a time delay in the model room reaching a steady temperature.The integration of phase change materials with metal roofing sheets resulted in better thermal performance and conservation of electrical energy by reducing the demand for cooling. 展开更多
关键词 ROOF metal sheets phase change materials energy saving thermal storage building materials
下载PDF
Promoting energy efficiency reconstruction for existing buildings based on comprehensive benefit evaluation 被引量:2
17
作者 GUO Han-ding ZHANG Yin-xian +1 位作者 WANG Yi-lin CUI Si-wen 《Ecological Economy》 2017年第4期332-337,共6页
The purpose of the comprehensive benefit evaluation of the existing building energy saving renovation project is to promote the healthy development of the energy saving reconstruction. Therefore, it is necessary to re... The purpose of the comprehensive benefit evaluation of the existing building energy saving renovation project is to promote the healthy development of the energy saving reconstruction. Therefore, it is necessary to reflect the value and function of incentive and restraint. The concrete embodiment is that: improving energy saving standard renovation of existing buildings, promoting the construction of energy efficiency labeling system, and strengthening the construction of government supervision system by the comprehensive benefit evaluation. 展开更多
关键词 energy efficiency reconstruction existing buildings comprehensive benefit evaluation incentive and restraint
下载PDF
Creation of Zero CO<sub>2</sub>Emissions Residential Buildings due to Operating and Embodied Energy Use on the Island of Crete, Greece 被引量:1
18
作者 John Vourdoubas 《Open Journal of Energy Efficiency》 2017年第4期141-154,共14页
The possibility of creating zero CO2 emissions residential buildings due to life cycle energy use in the island of Crete, Greece has been examined. In a typical residential building located in Crete, Greece, its annua... The possibility of creating zero CO2 emissions residential buildings due to life cycle energy use in the island of Crete, Greece has been examined. In a typical residential building located in Crete, Greece, its annual operating energy has been appraised at 170 KWh/m2 and its embodied energy at 30 KWh/m2. Various locally available renewable energies including solar energy, solid biomass and low enthalpy geothermal energy with heat pumps have been considered for generating the required heat and offsetting the grid electricity used. Their technologies are mature, reliable and cost-effective. Offset of the annual grid electricity use in the building with solar-PV electricity is allowed according to the net metering regulation. For zero carbon emissions due to embodied energy of the building, generation of additional solar electricity injected into the grid is required. A mathematical model has been developed for sizing the required solar-PV system installed in the building in order to offset the grid electricity use. For a residential building in Crete, Greece with a covered area of 100 m2, the power of the additional solar-PV system has been estimated at 1.6 KWp and its cost at 2400 €. In the current work, it is indicated that the creation of a zero CO2 emissions residential building due to life cycle energy use in Crete, Greece does not have major difficulties and it could be achieved relatively easily. 展开更多
关键词 buildings CO2 EMISSIONS CRETE Greece EMBODIED energy Operating energy Renewable Energies
下载PDF
Design of Low Carbon and Energy-saving New Rural Residential Buildings in Western Parts of Heilongjiang Province
19
作者 陈雨祥 刘剑虹 《Agricultural Science & Technology》 CAS 2015年第11期2560-2562,共3页
It is researched that rural residential buildings in Heilongjieng consume high energy and the living environment is poor. The research aimed at designing low-carbon and energy-saving buildings in order to reduce energ... It is researched that rural residential buildings in Heilongjieng consume high energy and the living environment is poor. The research aimed at designing low-carbon and energy-saving buildings in order to reduce energy consumption by applying energy storage. Besides, the research used composite solar panel, waste- based inorganic foam materials, and polystyrene board as construction materials and integrated energy collection, living environment and farming by energy storage system. It is notable that the research would reduce pollution on environment caused by residential buildings, which coincides with national economy development and en- ergy strategy, promoting construction material industry development, with high social and economic benefits. 展开更多
关键词 Low-carbon and energy-saving New residential buildings energy storage systern
下载PDF
The Impacts of Building Regulations on the Thermal Performance and Energy Consumption of Residential Buildings in Riyadh City-Saudi Arabia 被引量:1
20
作者 Saleh Baharetha Elsayed Amer Mohammad Kotbi 《Open Journal of Energy Efficiency》 2021年第1期1-21,共21页
Riyadh city is the fastest growing city in Saudi Arabia. The rapid urban growth that happened recently in Riyadh was not based on the traditional urban planning principles, which have been established and applied for ... Riyadh city is the fastest growing city in Saudi Arabia. The rapid urban growth that happened recently in Riyadh was not based on the traditional urban planning principles, which have been established and applied for the city development process. The imported building regulations have created a new urban structures and street patterns. The contemporary urban form in Riyadh city is based mainly on traffic and economic consideration with the neglect of environmental dimensions. This research aims to examine the impacts of building regulations on the thermal performance of residential buildings in Riyadh city, with the ultimate goal of establishing planning guidelines that consider the environmental conditions of the city. The methodology adopted for achieving the aim of this study consists of two phases. First, the literature related to building regulations development in Riyadh, as of 2018, was reviewed. Second, buildings energy simulation was conducted to examine the thermal performance of the typical current status of residential building blocks in Riyadh city, and then several changes to building regulations were made to investigate their impacts on the thermal performance of buildings. The results showed that the impacts of Riyadh building regulations on the thermal performance of residential buildings differ across the evaluated cases. The ratio of building height to street width, urban block street orientation, and building orientation are the main factors affecting thermal performance of buildings within urban block. The study also concludes that adjusting the ratio of building height to the distance between buildings could have a significant impact in reducing cooling loads. This study will help policy makers, planners and designers to investigate the shortcoming in the current building regulations. 展开更多
关键词 building Regulations energy Consumption Thermal Performance Residential buildings
下载PDF