Thermostat as a part of engine cooling system has a significant role in the shortening warm-up time and regulating the engine in proper temperature to approach optimal performance.Whereas,there is not adequate researc...Thermostat as a part of engine cooling system has a significant role in the shortening warm-up time and regulating the engine in proper temperature to approach optimal performance.Whereas,there is not adequate research on this part of the cooling system and its responsibility.Considering this gap and also being used in large scale,this study is intended to evaluate performance and reflex of the wax type thermostat in different engine working conditions.In this regard,performance of engine cooling system was investigated in various engine speeds and loads to reveal positive and negative influences of thermostat on engine cooling efficiency and engine performance.According to observed results,warm-up period and fuel consumption decrease by using a thermostat.On the other hand,however,the temperature oscillation of coolant fluid passing through engine increases sharply,which causes a disruption in the regulating engine temperature and also a possibility of the fluid boiling rises in some regions of the engine that increases the risk of damage in the engine parts.Engine temperature,fuel consumption,warm-up duration and emissions were provided and compared in two operation modes,with and without thermostat.展开更多
To predict the thermal and structural responses of the thrust chamber wall under cyclic work,a 3-D fluid-structural coupling computational methodology is developed.The thermal and mechanical loads are determined by a ...To predict the thermal and structural responses of the thrust chamber wall under cyclic work,a 3-D fluid-structural coupling computational methodology is developed.The thermal and mechanical loads are determined by a validated 3-D finite volume fluid-thermal coupling computational method.With the specified loads,the nonlinear thermal-structural finite element analysis is applied to obtaining the 3-D thermal and structural responses.The Chaboche nonlinear kinematic hardening model calibrated by experimental data is adopted to predict the cyclic plastic behavior of the inner wall.The methodology is further applied to the thrust chamber of LOX/Methane rocket engines.The results show that both the maximum temperature at hot run phase and the maximum circumferential residual strain of the inner wall appear at the convergent part of the chamber.Structural analysis for multiple work cycles reveals that the failure of the inner wall may be controlled by the low-cycle fatigue when the Chaboche model parameter c3= 0,and the damage caused by the thermal-mechanical ratcheting of the inner wall cannot be ignored when c3〉 0.The results of sensitivity analysis indicate that mechanical loads have a strong influence on the strains in the inner wall.展开更多
基金This work was supported by The Scientific and Technological Research Council of Turkey(TUBITAK,project no 315M260)。
文摘Thermostat as a part of engine cooling system has a significant role in the shortening warm-up time and regulating the engine in proper temperature to approach optimal performance.Whereas,there is not adequate research on this part of the cooling system and its responsibility.Considering this gap and also being used in large scale,this study is intended to evaluate performance and reflex of the wax type thermostat in different engine working conditions.In this regard,performance of engine cooling system was investigated in various engine speeds and loads to reveal positive and negative influences of thermostat on engine cooling efficiency and engine performance.According to observed results,warm-up period and fuel consumption decrease by using a thermostat.On the other hand,however,the temperature oscillation of coolant fluid passing through engine increases sharply,which causes a disruption in the regulating engine temperature and also a possibility of the fluid boiling rises in some regions of the engine that increases the risk of damage in the engine parts.Engine temperature,fuel consumption,warm-up duration and emissions were provided and compared in two operation modes,with and without thermostat.
文摘To predict the thermal and structural responses of the thrust chamber wall under cyclic work,a 3-D fluid-structural coupling computational methodology is developed.The thermal and mechanical loads are determined by a validated 3-D finite volume fluid-thermal coupling computational method.With the specified loads,the nonlinear thermal-structural finite element analysis is applied to obtaining the 3-D thermal and structural responses.The Chaboche nonlinear kinematic hardening model calibrated by experimental data is adopted to predict the cyclic plastic behavior of the inner wall.The methodology is further applied to the thrust chamber of LOX/Methane rocket engines.The results show that both the maximum temperature at hot run phase and the maximum circumferential residual strain of the inner wall appear at the convergent part of the chamber.Structural analysis for multiple work cycles reveals that the failure of the inner wall may be controlled by the low-cycle fatigue when the Chaboche model parameter c3= 0,and the damage caused by the thermal-mechanical ratcheting of the inner wall cannot be ignored when c3〉 0.The results of sensitivity analysis indicate that mechanical loads have a strong influence on the strains in the inner wall.