期刊文献+
共找到16篇文章
< 1 >
每页显示 20 50 100
Engineering practice and economic analysis of ozone oxidation wet denitrification technology 被引量:3
1
作者 Yang Li Defu Che +4 位作者 Chenglong Yang Mingyu Yao Tingwen Zhao Kangli Fu Hanchen Zhao 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2021年第1期401-408,共8页
SO_(2)and NO emitted from coal-fired power plants have caused serious air pollution in China.In this study,a test system for NO oxidation using O_(3)is established.The basic characteristics of NO oxidation and product... SO_(2)and NO emitted from coal-fired power plants have caused serious air pollution in China.In this study,a test system for NO oxidation using O_(3)is established.The basic characteristics of NO oxidation and products forms are studied.A separate test system for the combined removal of SO_(2)and NO_(x)is also established,and the absorption characteristics of NO_(x)are studied.The characteristics of NO oxidation and NO_(x)absorption were verified in a 35 t·h^(-1)industrial boiler wet combined desulfurization and denitrification project.The operating economy of ozone oxidation wet denitrification technology is analyzed.The results show that O_(3)has a high rate and strong selectivity for NO oxidation.When O_(3)is insufficient,the primary oxidation product is NO_(2).When O_(3)is present in excess,NO_(2)continues to get oxidized to N_(2)O_(5)or NO_(3).The removal efficiency of NO_(2)in alkaline absorption system is low(only about 15%).NOx removal efficiency can be improved by oxidizing NO_(x)to N_(2)O_(5)or NO_(3)by increasing ozone ratio.When the molar ratio of O_(3)/NO is 1.77,the NOx removal efficiency reaches 90.3%,while the operating cost of removing NO_(x)per kilogram is 6.06 USD(NO_(2)). 展开更多
关键词 OZONE DENITRIFICATION Wet process engineering practice
下载PDF
Engineering practices for the integration of large-scale renewable energy VSC-HVDC systems 被引量:7
2
作者 Yan Li Hongzhi Liu +1 位作者 Xiaojie Fan Xinshou Tian 《Global Energy Interconnection》 2020年第2期149-157,共9页
With the continuous development of power electronic devices,intelligent control systems,and other technologies,the voltage level and transmission capacity of voltage source converter (VSC)-high-voltage direct current ... With the continuous development of power electronic devices,intelligent control systems,and other technologies,the voltage level and transmission capacity of voltage source converter (VSC)-high-voltage direct current (HVDC) technology will continue to increase,while the system losses and costs will gradually decrease.Therefore,it can be foreseen that VSC-HVDC transmission technology will be more widely applied in future large-scale renewable energy development projects.Adopting VSC-HVDC transmission technology can be used to overcome issues encountered by large-scale renewable energy transmission and integration projects,such as a weak local power grid,lack of support for synchronous power supply,and insufficient accommodation capacity.However,this solution also faces many technical challenges because of the differences between renewable energy and traditional synchronous power generation systems.Based on actual engineering practices that are used worldwide,this article analyzes the technical challenges encountered by integrating large-scale renewable energy systems that adopt the use of VSC-HVDC technology,while aiming to provide support for future research and engineering projects related to VSC-HVDC-based large-scale renewable energy integration projects. 展开更多
关键词 VSC-HVDC Renewable energy integration DC grid engineering practice
下载PDF
Study on the technology for highway construction and engineering practices in permafrost regions 被引量:3
3
作者 ShuangJie Wang JianBing Chen JiLin Qi 《Research in Cold and Arid Regions》 2009年第5期412-422,共11页
关键词 highway engineering PERMAFROST technology research engineering practice
下载PDF
Exploration and Application of Ubiquitous Mapping in Engineering Practice Courses in the Intelligence Age 被引量:1
4
作者 Wei LI Xukang XIE +5 位作者 Haowen YAN Van Der Meijde MARK Lulu LIU Qianwen WANG Pengcheng GAO Hongyuan YU 《Journal of Geodesy and Geoinformation Science》 2022年第3期58-66,共9页
In the current era of digital surveying and mapping to intelligent surveying and mapping,ubiquitous surveying and mapping has brought many opportunities and challenges to college engineering course teaching.With the d... In the current era of digital surveying and mapping to intelligent surveying and mapping,ubiquitous surveying and mapping has brought many opportunities and challenges to college engineering course teaching.With the development of ubiquitous surveying and mapping,college engineering practice courses urgently need to respond to ubiquitous surveying and mapping.The research aims to integrate the development of ubiquitous surveying and mapping into the teaching of engineering practice courses in colleges,including promoting Android,Brower/Server(B/S),and Client/Server(C/S)to build a platform for practice courses.This also incorporates real development cases in measurement data processing such as gravity field refinement.In this way,the teaching level of engineering practice courses in colleges can be improved,and new ideas can be put forward for cultivating surveying and mapping talents in the new era in colleges.Finally,it can also provide new ideas for the organization of surveying and mapping practice courses under the background of the pandemic. 展开更多
关键词 intelligence age ubiquitous mapping engineering practice courses platform design PANDEMIC
下载PDF
Shaking table model test and engineering practice of a new gypsum-adobe walls dwelling in Xinjiang autonomous region, China
5
作者 周铁钢 胡昕 余长霞 《Acta Seismologica Sinica(English Edition)》 CSCD 2008年第3期319-324,333,共7页
The paper introduces a new type of green building which suits for the construction of rural dwellings in Xinjiang, China. Results of the shaking table test on building model show that the single-layer gypsum-adobe str... The paper introduces a new type of green building which suits for the construction of rural dwellings in Xinjiang, China. Results of the shaking table test on building model show that the single-layer gypsum-adobe structure has better seismic performance. And it also analyzes the construction features and engineering practice, which means that it is significant to extend this type of building to the drier regions in China. 展开更多
关键词 gypsum-adobe walls seismic performance engineering practice
下载PDF
Students’Feedback on Integrating Engineering Practice Cases into Lecture Task in Course of Built Environment
6
作者 杨学宾 钟珂 +2 位作者 陈琳娜 杨自力 梁珍 《Journal of Donghua University(English Edition)》 CAS 2022年第3期251-257,共7页
The improvement of students’abilities is of great significance to discover the relevant scientific problems in daily life,to analyze and solve practical problems,to trigger scientific inspiration,and to encourage inn... The improvement of students’abilities is of great significance to discover the relevant scientific problems in daily life,to analyze and solve practical problems,to trigger scientific inspiration,and to encourage innovation and entrepreneurship.Taken the course entitled Built Environment(BE)as an example,this study introduces five lecture cases combining with engineering practices,and examines the evaluation of teaching and learning effect on student outcomes.The cases consider various problems to be solved urgently in an actual project,and evaluate the student outcomes by statistically analyzing the questionnaires.Most of the students actively participate in five cases and cheerfully share their achievements.More than 85%of students are satisfied with the engineering practice and the learning proposal,and convey a little or even significantly change in their understanding of the employment prospects. 展开更多
关键词 student outcome FEEDBACK engineering practice lecture task Built Environment and Energy Application engineering(BEEAE)
下载PDF
Flue Gas Desulfurization Testing andIts Engineering Practice
7
作者 LuoYonglu 《Electricity》 1999年第4期21-25,共5页
关键词 OH In SO Flue Gas Desulfurization Testing andIts engineering practice
下载PDF
Engineering rock mechanics practices in the underground powerhouse at JinpingⅠhydropower station 被引量:4
8
作者 Aiqing Wu Jimin Wang +4 位作者 Zhong Zhou Shuling Huang Xiuli Ding Zhihong Dong Yuting Zhang 《Journal of Rock Mechanics and Geotechnical Engineering》 SCIE CSCD 2016年第5期640-650,共11页
Based on the analyses of data obtained from the underground powerhouse at Jinping I hydropower station, a comprehensive review of engineering rock mechanics practice in the underground powerhouse is first conducted. T... Based on the analyses of data obtained from the underground powerhouse at Jinping I hydropower station, a comprehensive review of engineering rock mechanics practice in the underground powerhouse is first conducted. The distribution of strata, lithology, and initial geo-stress, the excavation process and corresponding rock mass support measures, the deformation and failure characteristics of the surrounding rock mass, the stress characteristics of anchorage structures in the cavern complex, and numerical simulations of surrounding rock mass stability and anchor support performance are presented. The results indicate that the underground powerhouse of Jinping I hydropower station is characterized by high to extremely high geo-stresses during rock excavation. Excessive surrounding rock mass deformation and high stress of anchorage structures, surrounding rock mass unloading damage, and local cracking failure of surrounding rock masses, etc., are mainly caused by rock mass excavation. Deformations of surrounding rock masses and stresses in anchorage structures here are larger than those found elsewhere: 20% of extensometers in the main powerhouse record more than 50 mm with the maximum at around 250 mm observed in the downstream sidewall of the transformer hall. There are about 25% of the anchor bolts having recorded stresses of more than 200 MPa. Jinping I hydropower plant is the first to have an underground powerhouse construction conducted in host rocks under extremely high geo-stress conditions, with the ratio of rock mass strength to geo-stress of less than 2.0. The results can provide a reference to underground powerhouse construction in similar geological conditions. 展开更多
关键词 Underground powerhouse High geo-stress Rock mechanics Rock mass stability engineering practice
下载PDF
Engineering practice of mechanical soil aeration for the remediation of volatile organic compound-contaminated sites in China: Advantages and challenges 被引量:1
9
作者 Yan Ma Xiaoming Du +10 位作者 Yi Shi Deyi Hou Binbin Dong Zhu Xu Huiying Li Yunfeng Xie Jidun Fang Zheng Li Yunzhe Cao Qingbao Gu Fasheng Li 《Frontiers of Environmental Science & Engineering》 SCIE EI CAS CSCD 2016年第6期17-27,共11页
In recent years, many industrial enterprises located in the urban centers of China have been relocated owing to the rapid increase in urban development. At the sites abandoned by these enterprises, volatile organic co... In recent years, many industrial enterprises located in the urban centers of China have been relocated owing to the rapid increase in urban development. At the sites abandoned by these enterprises, volatile organic compounds have frequently been detected, sometimes at high concentrations, particularly at sites abandoned by chemical manufacturing enterprises. With the redevelopment of sites and changes in land-use tvpe associated with these sites, substantial amounts of contaminated soils now require remediation. "Since China is a developing country, soil remediation warrants the usage of techniques that are suitable for addressing the unique challenges faced in this country. Land shortage is a common problem in China; the large numbers of contaminated sites, tight development schedules, and limited financial resources necessitate the development of .cost-effective methods for land reclamation.Mechanical soil aeration is a simple, effective, and low-cost soil remediation tectm^que mat is particularly suitable for the remediation of large volatile organic compound-contaminated sites. Its effectiveness has been confirmed by conducting laboratory studies, pilot tests, and full-scale projects.This study reviews current engineei-ing practice and developmental trends of mechanical soil aeration and analyzes the advantages and disadvantages of this technology for application in China as an emerging soil remediation market. The findings of this study might aid technology development in China, as well as assist other developing countries in the assessment and implementation of costeffective hazardous waste site soil remediation programs. 展开更多
关键词 Soil contamination Volatile organic compound Mechanical soil aeration engineering practice China
原文传递
Engineering Practice Cultivation of the Young Teachers in Colleges based on OETP
10
作者 Linan Zhang Chao Chen 《好家长》 2018年第24期254-254,共1页
The 'Outstanding Engineers Training Plan'(OETP) aims to promote the development of higher engineering education constantly. Since the distinctive innovative, practical features of OETP, the college teachers’ ... The 'Outstanding Engineers Training Plan'(OETP) aims to promote the development of higher engineering education constantly. Since the distinctive innovative, practical features of OETP, the college teachers’ engineering practice ability has to be put forward to higher requirements. 展开更多
关键词 OETP Young teachers engineering practical ability
下载PDF
AN APPLICATION OF THEORETICAL SOLUTIONS ABOUT CYLINDRICAL SHELLS WITH SMALL OPENINGS
11
作者 宋天舒 刘殿魁 《Applied Mathematics and Mechanics(English Edition)》 SCIE EI 2000年第9期1066-1070,共5页
Stress concentrations about thin cylindrical shells with small openings are reconsidered front a nerv angle. There is a sort of special internal relation between theoretical solutions about cylindrical shells,vith lar... Stress concentrations about thin cylindrical shells with small openings are reconsidered front a nerv angle. There is a sort of special internal relation between theoretical solutions about cylindrical shells,vith large openings and one,with small openings. Using this relation, the extent of applying the theory about small openings to engineering practice is estimated again, thus an idea of how to use this theory and a nerv appraisal of the application of theoretical solutions about cylindrical shells with small openings to engineering practice are given. 展开更多
关键词 cylindrical shell with small opening cylindrical shell with large opening application to engineering practice
下载PDF
Development and applications of Baosteel sintering flue gas desulphurization technology
12
作者 SHEN Xiaolin LIU Daoqing LIN Yu SHI Lei WANG Ruyi 《Baosteel Technical Research》 CAS 2010年第2期7-12,共6页
The research background and technical features of Baosteel sintering flue gas desulphurization ( FGD)--swirl- jet-absorbing wet limestone-gypsum sintering FGD technology, process and equipment are introduced in this... The research background and technical features of Baosteel sintering flue gas desulphurization ( FGD)--swirl- jet-absorbing wet limestone-gypsum sintering FGD technology, process and equipment are introduced in this paper. Main contents and achievements of the pilot experiment and the engineering practice of Baosteel FGD are analyzed and discussed systematically. Past engineering practice experiences indicate that Baosteel FGD has the following merits: wide applicability to sintering flue gas features, such as frequently changing temperatures, unstable SO2 concentration, intensively fluctuating flow rates ,etc. ,high pollutants removal efficiency ,low investment and energy consumption; stable and reliable operation ,utilizable byproduct (gypsum), etc. It indicates that Baosteel sintering FGD is of extensive application value for the FGD of large and medium-scaled sintering machines. 展开更多
关键词 sintering flue gas desulphurization technology engineering practice
下载PDF
A Simple Cement Hydration Model Considering the Influences ofWater-to-Cement Ratio and Mineral Composition 被引量:1
13
作者 Baoyu Ma Guansuo Dui +5 位作者 Zhenglin Jia Bo Yang Chunyan Yang Quangui Gao Longhua Qin Ju Ma 《Computer Modeling in Engineering & Sciences》 SCIE EI 2021年第6期1059-1067,共9页
A simple hydration model is used here by taking the composition of the cement and the initial water: cementratio (w/c) into account explicitly. Its conceptual basis is a combination of the Avrami equation and Bentz’s... A simple hydration model is used here by taking the composition of the cement and the initial water: cementratio (w/c) into account explicitly. Its conceptual basis is a combination of the Avrami equation and Bentz’s modelbased on simple spatial considerations. In this model, the Avrami equation determines the initial reaction, andBentz’s model describes the following hydration stage. The model favors engineers for it relies on one experimentalparameter and has a reliable approximation in the practice. 展开更多
关键词 Hydration model water/cement ratio composition of the cement engineering practicability only one parameter
下载PDF
Assessment of Lead Exposures during Abrasive Blasting and Vacuuming in Ventilated Field Containments: A Case Study
14
作者 Kevin Guth Marie Bourgeois Raymond Harbison 《Occupational Diseases and Environmental Medicine》 2022年第2期116-131,共16页
Painting contractors have struggled with implementation and assessment of lead exposure controls leading to persistently elevated blood lead levels in this high-risk group of workers. The objective of this study was t... Painting contractors have struggled with implementation and assessment of lead exposure controls leading to persistently elevated blood lead levels in this high-risk group of workers. The objective of this study was to assess the intensity of lead exposures based on commonly used air velocities inside field containment structures during abrasive blasting and vacuuming. Exposures were assessed over 14 days from April to July 2021 at a tainter gate and bridge lead paint removal project. Personal air samples, skin wipes, air velocity readings, and blood lead samples were collected. The geometric mean (GM) lead exposure for abrasive blasters and vacuumers was ≥4 × the OSHA Lead Permissible Exposure Limit (PEL) of 50 μg/m<sup>3</sup>. There was high variability in the personal lead exposures (Geometric standard deviation (GSD) 4.0 - 5.0). The GM hand wipe exposures exceeded a Dermal PEL of 500 μg/wipe (abrasive blaster 564 μg/wipe and vacuumer 754 μg/wipe). Residual lead was measured on workers’ hands in 67% of the post hand washing samples. Air velocities measured inside of the field containments ranged from 107 feet per minute to 229 feet per minute. The effect of air velocity on the concentration of lead on workers’ hands after work (F = 0.58, p = 0.35) and airborne lead concentration was not significant (F = 0.36, p = 0.48). Six of the eight workers’ blood lead levels increased after exposure to lead. There was a non-statistically significant relationship between lead remaining on workers’ hands after handwashing and an increase in blood lead level. This is the first study that assessed both ventilation flow rates used in the industrial painting industry and measurements of airborne and dermal (hands) lead exposures. For the projects evaluated, the collected exposure data indicate that air velocities frequently used in the industrial painting industry to ventilate field containment structures did not tend to prevent an increase in worker blood lead and were ineffective for adequately controlling elevated concentrations of airborne lead and preventing contact with workers’ hands. 展开更多
关键词 Occupational Lead Exposure Blood Lead engineering/Work practice Controls
下载PDF
Seismic design and analysis of a high-rise self-centering wallbuilding:Case study
15
作者 Ying ZHOU Rui WANG Yiqiu LU 《Frontiers of Structural and Civil Engineering》 SCIE EI CSCD 2023年第11期1690-1706,共17页
Post-tensioning self-centering walls are a well-developed and resilient technology.However,despite extensive research,the application of this technology has previously been limited to low-rise buildings.A ten-story se... Post-tensioning self-centering walls are a well-developed and resilient technology.However,despite extensive research,the application of this technology has previously been limited to low-rise buildings.A ten-story selfcentering wall building has now been designed and constructed using the state-of-art design methodologies and construction detailing,as described in this paper.The building is designed in accordance with direct displacement-based design methodology,with modification of seismic demand due to relevant issues including higher-mode effects,second order effects,torsional effects,and flexural deformation of wall panels.Wall sections are designed with external energydissipating devices of steel dampers,and seismic performance of such designed self-centering walls is evaluated through numerical simulation.It is the first engineering project that uses self-centering walls in a high-rise building.The seismic design procedure of such a high-rise building,using self-centering wall structures,is comprehensively reviewed in this work,and additional proposals are put forward.Description of construction detailing,including slotted beams,flexible wall-to-floor connections,embedded beams,and damper installation,is provided.The demonstration project promotes the concept of seismic resilient structures and contributes to the most appealing city planning strategy of resilient cities at present.The paper could be a reference for industry engineers to promote the self-centering wall systems worldwide. 展开更多
关键词 self-centering wall post-tensioned precast concrete wall seismic resilient structure high-rise building seismic design engineering practice
原文传递
我国健康建筑的评价实践与思考 被引量:19
16
作者 盖轶静 孟冲 +1 位作者 韩沐辰 刘茂林 《科学通报》 EI CAS CSCD 北大核心 2020年第4期239-245,共7页
In January 2017,the Assessment Standard for Healthy Building(T/ASC 02-2016)was published.The issue and application of this standard indicates that healthy buildings have developed from labs to field in China.Based on ... In January 2017,the Assessment Standard for Healthy Building(T/ASC 02-2016)was published.The issue and application of this standard indicates that healthy buildings have developed from labs to field in China.Based on it,the concept of healthy buildings has been gradually implemented in the construction industry and has achieved preliminary results.This paper conducted statistical analysis on the healthy indexes level from 48 certificated projects and quantitatively demonstrated the practical effect of health building projects in China.At the same time,through the analysis of the healthy measures for different types of projects,this study also made a statistical analysis for the operational difficulty of the provisions of the standard in practice,providing practical reference for the continuous updating and improvement of the health building standard and providing reference for the project construction and the manager’s strategy formulation.Specific conclusions are as follows:(1)The health effects of the health building projects are reflected in several aspects:The average annual concentrations of indoor PM2.5 and PM10 are 14.8 and 23.9μg/m^3,respectively;the indoor average annual concentrations of formaldehyde and TVOC are 0.043 and 0.228 mg/m^3,respectively;68.8%of the total hardness of drinking water in the project is less than 150 mg/L(calculated by CaCO3);85.4%of the main functional rooms reached the thermal comfort level of ClassⅠ;the free fitness area takes 1.9%of the total area.(2)The higher the quality of the project is,the better the balance among the healthy elements is.In general,the score of items related to water takes 59%and 55%for comfort,which are significantly lower than that of air(82%),fitness(84%)and humanity(73%).However,the degree of practice completion is relatively low.It is suggested that the standard compilers should refer to the difficulty feedback of project practice in the process of standard revision.(3)According to the difficulty index value from low to high,the provisions are divided into 1-5 categories.Among them,9 provisions(6.2.15,8.2.4,6.2.4,8.2.3,8.2.9,6.2.6,7.2.6,7.2.4,6.2.14)have significant differences in the difficulty index between public construction and residential construction.(4)The non-participation rates of 6 provisions(5.2.3,6.2.4,6.2.15,6.2.16,7.2.6,8.2.8)were 64%,93%,64%,64%,77%and 84%,respectively.There are three types of reasons:Residential buildings do not participate in the evaluation,public buildings do not participate in the evaluation and projects without designated special space do not participate in the evaluation.Therefore,it is suggested that in the process of standard perfection,corresponding measures should be taken to improve the effective use rate of provisions.(5)In this paper,measure provisions in the standard are summarized into 16 technical measures,among which intelligent lighting technology,natural lighting technology and outdoor acoustic environment construction technology score rate are significantly lower.There are obvious differences in the selection of public buildings and residential buildings in terms of indoor acoustic environment control technology,natural lighting technology,fitness site design and child-friendly design. 展开更多
关键词 healthy building industry status engineering practice project evaluation technology selection
原文传递
上一页 1 下一页 到第