AIM:To evaluate the peripapillary choroidal thickness(PPCT) in Chinese children,and to analyze the influencing factors.METHODS: PPCT was measured with enhanced depth imaging optical coherence tomography(EDI-OCT) in 70...AIM:To evaluate the peripapillary choroidal thickness(PPCT) in Chinese children,and to analyze the influencing factors.METHODS: PPCT was measured with enhanced depth imaging optical coherence tomography(EDI-OCT) in 70children(53 myopes and 17 non-myopes) aged 7 to 18 y,with spherical equivalent refractive errors between 0.50and-5.87 diopters(D).Peripapillary choroidal imaging was performed using circular scans of a diameter of 3.4 mm around the optic disc.PPCT was measured by EDI-OCT in six sectors: nasal(N),superonasal(SN),superotemporal(ST),temporal(T),inferotemporal(IT)and inferonasal(IN),as well as global RNFL thickness(G).RESULTS: The mean global PPCT was 165.49±33.76 μm.The temporal,inferonasal,inferotemporal PPCT were significantly thinner than the nasal,superonasal,superotemporal segments PPCT were significantly thinner in the myopic group at temporal,superotemporal and inferotemporal segments.The axial length was significantly associated with the average global(β=-0.419,P =0.014),superonasal(β=-2.009,P=0.049) and inferonasal(β=-2.000,P=0.049) PPCT.The other factors(gender,age,SE) were not significantly associated with PPCT.CONCLUSION: PPCT was thinner in the myopic group at temporal,superotemporal and inferotemporal segments.The axial length was found to be negatively correlated to PPCT.We need more further studies about the relationship between PPCT and myopia.展开更多
AIM: To describe and evaluate a standardized protocol for measuring the choroidal thickness(Ch T) using enhanced depth imaging optical coherence tomography(EDI OCT).METHODS: Single 9 mm EDI OCT line scans across the f...AIM: To describe and evaluate a standardized protocol for measuring the choroidal thickness(Ch T) using enhanced depth imaging optical coherence tomography(EDI OCT).METHODS: Single 9 mm EDI OCT line scans across the fovea were used for this study. The protocol used in this study classified the EDI OCT images into four groups based on the appearance of the choroidal-scleral interface and suprachoroidal space. Two evaluation iterations of experiments were performed: first, the protocol was validated in a pilot study of 12 healthy eyes. Afterwards, the applicability of the protocol was tested in 82 eyes of patients with diabetes. Inter-observer and intra-observer agreements on image classifications were performed using Cohen's kappa coefficient(κ). Intraclass correlation coefficient(ICC) and Bland-Altman's methodology were used for the measurement of the Ch T.RESULTS: There was a moderate(κ=0.42) and perfect(κ =1) inter- and intra-observer agreements on image classifications from healthy eyes images and substantial(κ =0.66) and almost perfect(κ =0.86) agreements from diabetic eyes images. The proposed protocol showed excellent inter- and intra-observer agreements for the Ch T measurements on both, healthy eyes and diabetic eyes(ICC >0.90 in all image categories). The Bland-Altman plot showed a relatively large Ch T measurement agreement in the scans that contained less visible choroidal outer boundary. CONCLUSION: A protocol to standardize Ch T measurements in EDI OCT images has been developed;the results obtained using this protocol show that the technique is accurate and reliable for routine clinical practice and research.展开更多
AIM:To characterize spectral-domain optical coherence tomography(SD-OCT)features of chorioretinal folds in orbital mass imaged using enhanced depth imaging(EDI).METHODS:Prospective observational case-control study was...AIM:To characterize spectral-domain optical coherence tomography(SD-OCT)features of chorioretinal folds in orbital mass imaged using enhanced depth imaging(EDI).METHODS:Prospective observational case-control study was conducted in 20 eyes of 20 patients,the uninvolved eye served as a control.All the patients underwent clinical fundus photography,computed tomography,EDI SDOCT imaging before and after surgery.Two patients with cavernous hemangiomas underwent intratumoral injection of bleomycin A5;the remaining patients underwent tumor excision.Patients were followed 1 to 14mo following surgery(average follow up,5.8mo).RESULTS:Visual acuity prior to surgery ranged from 20/20 to 20/200.Following surgery,5 patients’visual acuity remained unchanged while the remaining 15 patients had a mean letter improvement of 10(range 4 to 26 letters).Photoreceptor inner/outer segment defects were found in 10 of 15 patients prior to surgery.Following surgical excision,photoreceptor inner/outer segment defects fully resolved in 8 of these 10 patients.CONCLUSION:Persistence of photoreceptor inner/outer segment defects caused by compression of the globe by an orbital mass can be associated with reduced visual prognosis.Our findings suggest that photoreceptor inner/outer segment defects on EDI SD-OCT could be an indicator for immediate surgical excision of an orbital mass causing choroidal compression.展开更多
In this work,we present an intravascular dual-mode endoscopic system capable of both intravascular photoacoustic imaging(IVPAI)and intravascular optical coherence tomography(IVOCT)for recognizing spontaneous coronary ...In this work,we present an intravascular dual-mode endoscopic system capable of both intravascular photoacoustic imaging(IVPAI)and intravascular optical coherence tomography(IVOCT)for recognizing spontaneous coronary artery dissection(SCAD)phantoms.IVPAI provides high-resolution and high-penetration images of intramural hematoma(IMH)at different depths,so it is especially useful for imaging deep blood clots associated with imaging phantoms.IVOCT can readily visualize the double-lumen morphology of blood vessel walls to identify intimal tears.We also demonstrate the capability of this dual-mode endoscopic system using mimicking phantoms and biological samples of blood clots in ex vivo porcine arteries.The results of the experiments indicate that the combined IVPAI and IVOCT technique has the potential to provide a more accurate SCAD assessment method for clinical applications.展开更多
AIM:To assess peripapillary retinal nerve fiber layer(RNFL) and choroidal thickness obtained with enhanced depth imaging(EDI) mode compared with those obtained without EDI mode using Heidelberg Spectralis optical cohe...AIM:To assess peripapillary retinal nerve fiber layer(RNFL) and choroidal thickness obtained with enhanced depth imaging(EDI) mode compared with those obtained without EDI mode using Heidelberg Spectralis optical coherence tomography(OCT).METHODS:Fifty eyes of 25 normal healthy subjects and 32 eyes of 20 patients with different eye diseases were included in the study.All subjects underwent 3.4 mm diameter peripapillary circular OCT scan centered on the optic disc using both the conventional and the EDI OCT protocols.The visualization of RNFL and choroidoscleral junction was assessed using an ordinal scoring scale.The paired t-test,intraclass correlation coefficient(ICC),95% limits of agreement(Lo A),and Bland and Altman plots were used to test the agreement of measurements.RESULTS:The visibility score of RNFL obtained with and without EDI was of no significant difference(P=0.532),the visualization of choroidoscleral junction was better using EDI protocol than conventional protocol(P<0.001).Peripapillary RNFL thickness obtained with EDI was slightly thicker than that obtained without EDI(103.25±9.42 μm vs 101.87±8.78 μm,P=0.010).The ICC of the two protocols was excellent with the value of 0.867 to 0.924,the 95% Lo A of global RNFL thickness was between-10.0 to 7.4 μm.Peripapillary choroidal thickness obtained with EDI was slightly thinner than that obtained without EDI(147.23±51.04 μm vs 150.90±51.84 μm,P<0.001).The ICC was also excellent with the value of 0.960 to 0.987,the 95% Lo A of global choroidal thickness was between-12.5 to 19.8 μm.CONCLUSION:Peripapillary circular OCT scan with or without EDI mode shows comparable results in the measurement of peripapillary RNFL and choroidal thickness.展开更多
Limited by the dynamic range of the detector,saturation artifacts usually occur in optical coherence tomography(OCT)imaging for high scattering media.The available methods are difficult to remove saturation artifacts ...Limited by the dynamic range of the detector,saturation artifacts usually occur in optical coherence tomography(OCT)imaging for high scattering media.The available methods are difficult to remove saturation artifacts and restore texture completely in OCT images.We proposed a deep learning-based inpainting method of saturation artifacts in this paper.The generation mechanism of saturation artifacts was analyzed,and experimental and simulated datasets were built based on the mechanism.Enhanced super-resolution generative adversarial networks were trained by the clear–saturated phantom image pairs.The perfect reconstructed results of experimental zebrafish and thyroid OCT images proved its feasibility,strong generalization,and robustness.展开更多
Diabetic retinopathy(DR)is one of the major causes of visual impairment in adults with diabetes.Optical coherence tomography angiography(OCTA)is nowadays widely used as the golden criterion for diagnosing DR.Recently,...Diabetic retinopathy(DR)is one of the major causes of visual impairment in adults with diabetes.Optical coherence tomography angiography(OCTA)is nowadays widely used as the golden criterion for diagnosing DR.Recently,wide-field OCTA(WF-OCTA)provided more abundant information including that of the peripheral retinal degenerative changes and it can contribute in accurately diagnosing DR.The need for an automatic DR diagnostic system based on WF-OCTA pictures attracts more and more attention due to the large diabetic population and the prevalence of retinopathy cases.In this study,automatic diagnosis of DR using vision transformer was performed using WF-OCTA images(12 mm×12 mm single-scan)centered on the fovea as the dataset.WF-OCTA images were automatically classified into four classes:No DR,mild nonproliferative diabetic retinopathy(NPDR),moderate to severe NPDR,and proliferative diabetic retinopathy(PDR).The proposed method for detecting DR on the test set achieves accuracy of 99.55%,sensitivity of 99.49%,and specificity of 99.57%.The accuracy of the method for DR staging reaches up to 99.20%,which has been proven to be higher than that attained by classical convolutional neural network models.Results show that the automatic diagnosis of DR based on vision transformer and WF-OCTA pictures is more effective for detecting and staging DR.展开更多
AIM:To measure the difference of intraoperative central macular thickness(CMT)before,during,and after membrane peeling and investigate the influence of intraoperative macular stretching on postoperative best corrected...AIM:To measure the difference of intraoperative central macular thickness(CMT)before,during,and after membrane peeling and investigate the influence of intraoperative macular stretching on postoperative best corrected visual acuity(BCVA)outcome and postoperative CMT development.METHODS:A total of 59 eyes of 59 patients who underwent vitreoretinal surgery for epiretinal membrane was analyzed.Videos with intraoperative optical coherence tomography(OCT)were recorded.Difference of intraoperative CMT before,during,and after peeling was measured.Pre-and postoperatively obtained BCVA and spectral-domain OCT images were analyzed.RESULTS:Mean age of the patients was 70±8.13y(range 46-86y).Mean baseline BCVA was 0.49±0.27 log MAR(range 0.1-1.3).Three and six months postoperatively the mean BCVA was 0.36±0.25(P=0.01 vs baseline)and 0.38±0.35(P=0.08 vs baseline)log MAR respectively.Mean stretch of the macula during surgery was 29%from baseline(range 2%-159%).Intraoperative findings of macular stretching did not correlate with visual acuity outcome within 6mo after surgery(r=-0.06,P=0.72).However,extent of macular stretching during surgery significantly correlated with less reduction of CMT at the fovea centralis(r=-0.43,P<0.01)and 1 mm nasal and temporal from the fovea(r=-0.37,P=0.02 and r=-0.50,P<0.01 respectively)3mo postoperatively.CONCLUSION:The extent of retinal stretching during membrane peeling may predict the development of postoperative central retinal thickness,though there is no correlation with visual acuity development within the first 6mo postoperatively.展开更多
Dear Editor,The state of the vitreo-retinal interface affects various retinal diseases,and the presence or absence of a posterior vitreous detachment(PVD)is one of the most important factors^([1-5]).As such,various st...Dear Editor,The state of the vitreo-retinal interface affects various retinal diseases,and the presence or absence of a posterior vitreous detachment(PVD)is one of the most important factors^([1-5]).As such,various studies studying PVD in relation to retinal disease have been performed^([1-5]).展开更多
The parallel spectral-domain optical coherence tomography(PSDOCT) is described for high-speed optical coherence tomography(OCT) without lateral scanning. In this setup, the self-elimination of auto-correlation(AC) int...The parallel spectral-domain optical coherence tomography(PSDOCT) is described for high-speed optical coherence tomography(OCT) without lateral scanning. In this setup, the self-elimination of auto-correlation(AC) interference algorithm was used for eradicating the AC interference and ghost images. However, when performed in free space OCT, this algorithm still generated a weak DC component. The algorithm was improved by adding the background intensity part to compensate for the mutual interference between object and reference arms. The results demonstrate that the DC component can be eradicated. Compared with conventional OCT and complex Fourier-domain optical coherence tomography, the advantages of PSDOCT with the improved algorithm in free space are that it has no moving parts to generate consecutive phase shift, the structure of the object can be reconstructed immediately and automatically, and the speed is approximately 16 times faster than those of the other two in the same case.展开更多
Histopathological examination is still the gold standard for diagnoses of oral-maxillofacial lesions,but it is invasive and time-consuming.Optical coherence tomography(OCT)provides a kind of noninvasive,label-free,rea...Histopathological examination is still the gold standard for diagnoses of oral-maxillofacial lesions,but it is invasive and time-consuming.Optical coherence tomography(OCT)provides a kind of noninvasive,label-free,real-time and high-resolution imaging technology.In this study,in order to assess the feasibility of OCT in oral clinical application,fresh excised tissue specimens from 59 patients undergoing oral-maxillofacial surgery were imaged in detail by using a benchtop sweptsource OCT system.It is shown that different lesions or tissues can be obviously distinguished based on their different microstructural features in OCT images,and the features are similar to those of their corresponding histopathological images.It is proven that OCT has great feasibility and potential as a diagnostic aid for surgeons in oral medicine.展开更多
Arterial plaque from a myocardial infarction-prone Watanabe heritable hyperlipidemic (WHHLMI) rabbit is visualized and characterized using a signal to noise ratio enhanced swept-source optical coherence tomography sys...Arterial plaque from a myocardial infarction-prone Watanabe heritable hyperlipidemic (WHHLMI) rabbit is visualized and characterized using a signal to noise ratio enhanced swept-source optical coherence tomography system with a quadrature interferometer (QSS-OCT). A semiconductor optical amplifier is used in the sample arm to amplify the weak signal scattered from arterial plague. Signal to noise ratio improvement are demonstrated in our QSS-OCT system. This finding results into an increase of the penetration depth possible in OCT images, from 1 mm to 2 mm. Preliminary results show that vulnerable plaque with fibrous cap, macrophage accumulations and calcification in the arterial tissue are measurable with our QSS-OCT system.展开更多
Starting with introduction of basic concept of optical coherence tomography(OCT) techniques,this paper focuses on a detailed review of ophthalmic OCT instruments and their clinical applications. As one of the most imp...Starting with introduction of basic concept of optical coherence tomography(OCT) techniques,this paper focuses on a detailed review of ophthalmic OCT instruments and their clinical applications. As one of the most important inventions of ophthalmology instruments,OCT has become a standard imaging tool for daily ophthalmic diagnosis. The imaging capability has been significantly improved during the past ~ 30 years. In this article,several representing systems which have made significant contributions to OCT developments will be reviewed in details. For each system,the system configuration will be discussed first,follow ed by a brief introduction of their clinical applications. The review concludes with discussions on potential directions of OCT developments and expectations for further improvements of OCT imaging capabilities.展开更多
AIM: To explore a segmentation algorithm based on deep learning to achieve accurate diagnosis and treatment of patients with retinal fluid.METHODS: A two-dimensional(2D) fully convolutional network for retinal segment...AIM: To explore a segmentation algorithm based on deep learning to achieve accurate diagnosis and treatment of patients with retinal fluid.METHODS: A two-dimensional(2D) fully convolutional network for retinal segmentation was employed. In order to solve the category imbalance in retinal optical coherence tomography(OCT) images, the network parameters and loss function based on the 2D fully convolutional network were modified. For this network, the correlations of corresponding positions among adjacent images in space are ignored. Thus, we proposed a three-dimensional(3D) fully convolutional network for segmentation in the retinal OCT images.RESULTS: The algorithm was evaluated according to segmentation accuracy, Kappa coefficient, and F1 score. For the 3D fully convolutional network proposed in this paper, the overall segmentation accuracy rate is 99.56%, Kappa coefficient is 98.47%, and F1 score of retinal fluid is 95.50%. CONCLUSION: The OCT image segmentation algorithm based on deep learning is primarily founded on the 2D convolutional network. The 3D network architecture proposed in this paper reduces the influence of category imbalance, realizes end-to-end segmentation of volume images, and achieves optimal segmentation results. The segmentation maps are practically the same as the manual annotations of doctors, and can provide doctors with more accurate diagnostic data.展开更多
Current gradient-index(GRIN)lens based proximal-driven intracoronary optical coherence tomography(ICOCT)probes consist of a spacer and a GRIN lens with large gradient constant.This design provides great flexibility to...Current gradient-index(GRIN)lens based proximal-driven intracoronary optical coherence tomography(ICOCT)probes consist of a spacer and a GRIN lens with large gradient constant.This design provides great flexibility to control beam profiles,but the spacer length should be well controlled to obtain desired beam profiles and thus it sets an obstacle in mass catheter fabrication.Besides,although GRIN lens with large gradient constant can provide tight focus spot,it has short depth of focus and fast-expanded beam which leads to poor lateral resolution for deep tissue.In this paper,a type of spacer-removed probe is demonstrated with a small gradient constant GRIN lens.This design simplifies the fabrica-tion process and is suitable for mass production.The output beam of the catheter is a narrow nearly collimated light beam,referred to as pencil beam here.The full width at half maximum beam size varies from 35.1μm to 75.3μm in air over 3-mm range.Probe design principles are elaborated with probe/catheter fabrication and performance test.The in vivo imaging of the catheter was verified by a clinical ICOCT system.Those results prove that this novel pencil-beam scanning catheter is potentially a good choice for ICOCT systems.展开更多
All-optically integrated photoacoustic(PA)and optical coherence tomography(OCT)dualmode imaging technology that could o®er comprehensive pathological information for accurate diagnosis in clinic has gradually bec...All-optically integrated photoacoustic(PA)and optical coherence tomography(OCT)dualmode imaging technology that could o®er comprehensive pathological information for accurate diagnosis in clinic has gradually become a promising imaging technology in the aspect of biomedical imaging during the recent years.This review refers to the technology aspects of alloptical PA detection and system evolution of optically integrated PA and OCT,including Michelson interferometer dual-mode imaging system,Fabry–Perot(FP)interferometer dualmode imaging system and Mach–Zehnder interferometer dual-mode imaging system.It is believed that the optically integrated PA and OCT has great potential applications in biomedical imaging.展开更多
Doppler Optical Coherence Tomography(DOCT)is a noninvasive optical diagnostic technique,which is well suited for the quantitative mapping of microflow velocity profiles and the analysis of flow-vessel interactions.The...Doppler Optical Coherence Tomography(DOCT)is a noninvasive optical diagnostic technique,which is well suited for the quantitative mapping of microflow velocity profiles and the analysis of flow-vessel interactions.The noninvasive imaging and quantitative analysis of blood flow in the complex-structured vascular bed is required in many biomedical applications,including those where the determination of mechanical properties of vessels or the knowledge of the mechanic interactions between the flow and the housing medium plays a key role.The change of microvessel wall elasticity could be a potential indicator of cardiovascular disease at the very early stage,whilst monitoring the blood flow dynamics and associated temporal and spatial variations in vessel’s wall shear stress could help predicting the possible rupture of atherosclerotic plaques.The results of feasibility studies of application of DOCT for the evaluation of mechanical properties of elastic vessel model are presented.The technique has also been applied for imaging of sub-cranial rat blood flow in vivo.展开更多
Optical coherence tomography(OCT)allows a direct and precise measurement of laser welding depth by coaxially measuring the keyhole depth and can be used for process monitoring and control.When OCT measurement was take...Optical coherence tomography(OCT)allows a direct and precise measurement of laser welding depth by coaxially measuring the keyhole depth and can be used for process monitoring and control.When OCT measurement was taken during single-beam laser welding,the keyhole instability of aluminum welding resulted in highly scattered OCT data and complicated the welding depth extraction methods.As a combination of an inner core beam and an outer ring beam,a novel adjustable ring mode(ARM)laser for producing a stable keyhole was applied to the OCT measurement.Different ARM laser power arrangements were conducted on aluminum and copper.The results indicated that the ring beam greatly improved the stability of the core beam-induced keyhole,and smooth welding depth can be extracted from the concentrated OCT data.展开更多
BACKGROUND Chronic radiation proctopathy(CRP) occurs as a result of pelvic radiation therapy and is associated with formation of abnormal vasculature that may lead to persistent rectal bleeding. While incidence is dec...BACKGROUND Chronic radiation proctopathy(CRP) occurs as a result of pelvic radiation therapy and is associated with formation of abnormal vasculature that may lead to persistent rectal bleeding. While incidence is declining due to refinement of radiation delivery techniques, CRP remains one of the major complications of pelvic radiation therapy and significantly affects patient quality of life.Radiofrequency ablation(RFA) is an emerging treatment modality for eradicating abnormal vasculature associated with CRP. However, questions remain regarding CRP pathophysiology and optimal disease management.AIM To study feasibility of optical coherence tomography angiography(OCTA) for investigating subsurface vascular alterations in CRP and response to RFA treatment.METHODS Two patients with normal rectum and 8 patients referred for, or undergoing endoscopic RFA treatment for CRP were imaged with a prototype ultrahighspeed optical coherence tomography(OCT) system over 15 OCT/colonoscopy visits(2 normal patients, 5 RFA-na?ve patients, 8 RFA-follow-up visits). OCT and OCTA was performed by placing the OCT catheter onto the dentate line and rectum without endoscopic guidance. OCTA enabled depth-resolved microvasculature imaging using motion contrast from flowing blood, withoutrequiring injected dyes. OCTA features of normal and abnormal microvasculature were assessed in the mucosa and submucosa. Blinded reading of OCTA images was performed to assess the association of abnormal rectal microvasculature with CRP and RFA treatment, and rectal telangiectasia density endoscopic scoring.RESULTS OCTA/OCT images are intrinsically co-registered and enabled depth-resolved visualization of microvasculature in the mucosa and submucosa. OCTA visualized normal vascular patterns with regular honeycomb patterns vs abnormal vasculature with distorted honeycomb patterns and ectatic/tortuous microvasculature in the rectal mucosa. Normal arterioles and venules < 200 μm in diameter versus abnormal heterogenous enlarged arterioles and venules > 200μm in diameter were visualized in the rectal submucosa. Abnormal mucosal vasculature occurred in 0 of 2 normal patients and 3 of 5 RFA-na?ve patients,while abnormal submucosal vasculature occurred more often, in 1 of 2 normal patients and 5 of 5 RFA-na?ve patients. After RFA treatment, vascular abnormalities decreased, with abnormal mucosal vasculature observed in 0 of 8 RFA-follow-up visits and abnormal submucosal vasculature observed in only and 2 of 8 RFA-follow-up visits.CONCLUSION OCTA visualizes depth-resolved microvascular abnormalities in CRP, allowing assessment of superficial features which are endoscopically visible as well as deeper vasculature which cannot be seen endoscopically. OCTA/OCT of the rectum can be performed in conjunction with, or independently from endoscopy.Further studies are warranted to investigate if OCTA/OCT can elucidate pathophysiology of CRP or improve management.展开更多
AIM: To assess the repeatability of measuring optic nerve head(ONH) parameters using the Cirrus optical coherence tomography(OCT), as well as to assess the effect of head tilt on these measurements.METHODS: Thirty hea...AIM: To assess the repeatability of measuring optic nerve head(ONH) parameters using the Cirrus optical coherence tomography(OCT), as well as to assess the effect of head tilt on these measurements.METHODS: Thirty healthy participants with no evidence of glaucoma were recruited for the study. Visual acuity, intraocular pressure, standard automated perimetry and ocular examination were performed for each participant. One eye was then randomly selected and scanned undilated with the Cirrus OCT in 3 positions(neutral, 30° right tilt and 30° left tilt).RESULTS: Data collected from 29 eyes were used for analysis. One patient was omitted due to poor scan quality. The repeatability of the ONH parameters was analyzed using analysis of variance, coefficient of variation(COV) and intraclass correlation coefficient(ICC). Analysis of variance showed no statistically significant difference between 3 scans in a single position. There was good agreement between measurements(ICC 0.919-0.996, COV 1.94%-5.48%).Even with the presence of head tilt, repeated scans in the 3 positions showed good agreement as well(ICC 0.888-0.996, COV 2.04%-5.39%).CONCLUSION: Serial measurements of ONH parameters using the Cirrus OCT are found to have good repeatability. The ONH parameters with Cirrus OCT also maintain good repeatability despite head tilt.展开更多
基金Supported by Major Scientific and Technological Projects in Zhejiang Province,China(No.2013c03048-3)the Science and Technology Plan Project of Wenzhou Science and Technology Bureau(No.Y20150284)Medical Scientific Research Foundation of Zhejiang Province(No.2016ZDA016)
文摘AIM:To evaluate the peripapillary choroidal thickness(PPCT) in Chinese children,and to analyze the influencing factors.METHODS: PPCT was measured with enhanced depth imaging optical coherence tomography(EDI-OCT) in 70children(53 myopes and 17 non-myopes) aged 7 to 18 y,with spherical equivalent refractive errors between 0.50and-5.87 diopters(D).Peripapillary choroidal imaging was performed using circular scans of a diameter of 3.4 mm around the optic disc.PPCT was measured by EDI-OCT in six sectors: nasal(N),superonasal(SN),superotemporal(ST),temporal(T),inferotemporal(IT)and inferonasal(IN),as well as global RNFL thickness(G).RESULTS: The mean global PPCT was 165.49±33.76 μm.The temporal,inferonasal,inferotemporal PPCT were significantly thinner than the nasal,superonasal,superotemporal segments PPCT were significantly thinner in the myopic group at temporal,superotemporal and inferotemporal segments.The axial length was significantly associated with the average global(β=-0.419,P =0.014),superonasal(β=-2.009,P=0.049) and inferonasal(β=-2.000,P=0.049) PPCT.The other factors(gender,age,SE) were not significantly associated with PPCT.CONCLUSION: PPCT was thinner in the myopic group at temporal,superotemporal and inferotemporal segments.The axial length was found to be negatively correlated to PPCT.We need more further studies about the relationship between PPCT and myopia.
基金Supported by Foundation for the Prevention of Blindness
文摘AIM: To describe and evaluate a standardized protocol for measuring the choroidal thickness(Ch T) using enhanced depth imaging optical coherence tomography(EDI OCT).METHODS: Single 9 mm EDI OCT line scans across the fovea were used for this study. The protocol used in this study classified the EDI OCT images into four groups based on the appearance of the choroidal-scleral interface and suprachoroidal space. Two evaluation iterations of experiments were performed: first, the protocol was validated in a pilot study of 12 healthy eyes. Afterwards, the applicability of the protocol was tested in 82 eyes of patients with diabetes. Inter-observer and intra-observer agreements on image classifications were performed using Cohen's kappa coefficient(κ). Intraclass correlation coefficient(ICC) and Bland-Altman's methodology were used for the measurement of the Ch T.RESULTS: There was a moderate(κ=0.42) and perfect(κ =1) inter- and intra-observer agreements on image classifications from healthy eyes images and substantial(κ =0.66) and almost perfect(κ =0.86) agreements from diabetic eyes images. The proposed protocol showed excellent inter- and intra-observer agreements for the Ch T measurements on both, healthy eyes and diabetic eyes(ICC >0.90 in all image categories). The Bland-Altman plot showed a relatively large Ch T measurement agreement in the scans that contained less visible choroidal outer boundary. CONCLUSION: A protocol to standardize Ch T measurements in EDI OCT images has been developed;the results obtained using this protocol show that the technique is accurate and reliable for routine clinical practice and research.
基金Supported by National Natural Science Foundation of China(No.81300805)。
文摘AIM:To characterize spectral-domain optical coherence tomography(SD-OCT)features of chorioretinal folds in orbital mass imaged using enhanced depth imaging(EDI).METHODS:Prospective observational case-control study was conducted in 20 eyes of 20 patients,the uninvolved eye served as a control.All the patients underwent clinical fundus photography,computed tomography,EDI SDOCT imaging before and after surgery.Two patients with cavernous hemangiomas underwent intratumoral injection of bleomycin A5;the remaining patients underwent tumor excision.Patients were followed 1 to 14mo following surgery(average follow up,5.8mo).RESULTS:Visual acuity prior to surgery ranged from 20/20 to 20/200.Following surgery,5 patients’visual acuity remained unchanged while the remaining 15 patients had a mean letter improvement of 10(range 4 to 26 letters).Photoreceptor inner/outer segment defects were found in 10 of 15 patients prior to surgery.Following surgical excision,photoreceptor inner/outer segment defects fully resolved in 8 of these 10 patients.CONCLUSION:Persistence of photoreceptor inner/outer segment defects caused by compression of the globe by an orbital mass can be associated with reduced visual prognosis.Our findings suggest that photoreceptor inner/outer segment defects on EDI SD-OCT could be an indicator for immediate surgical excision of an orbital mass causing choroidal compression.
基金funding from the National Natural Science Foundation of China(NSFC)under grants 61627827,61705068the Natural Science Foundation of Fujian Province 2021J01813the Fujian Medical University Research Foundation of Talented Scholars XRCZX2021004.
文摘In this work,we present an intravascular dual-mode endoscopic system capable of both intravascular photoacoustic imaging(IVPAI)and intravascular optical coherence tomography(IVOCT)for recognizing spontaneous coronary artery dissection(SCAD)phantoms.IVPAI provides high-resolution and high-penetration images of intramural hematoma(IMH)at different depths,so it is especially useful for imaging deep blood clots associated with imaging phantoms.IVOCT can readily visualize the double-lumen morphology of blood vessel walls to identify intimal tears.We also demonstrate the capability of this dual-mode endoscopic system using mimicking phantoms and biological samples of blood clots in ex vivo porcine arteries.The results of the experiments indicate that the combined IVPAI and IVOCT technique has the potential to provide a more accurate SCAD assessment method for clinical applications.
基金Supported by Wenzhou Municipal Science and Technology Bureau(No.Y20150257)
文摘AIM:To assess peripapillary retinal nerve fiber layer(RNFL) and choroidal thickness obtained with enhanced depth imaging(EDI) mode compared with those obtained without EDI mode using Heidelberg Spectralis optical coherence tomography(OCT).METHODS:Fifty eyes of 25 normal healthy subjects and 32 eyes of 20 patients with different eye diseases were included in the study.All subjects underwent 3.4 mm diameter peripapillary circular OCT scan centered on the optic disc using both the conventional and the EDI OCT protocols.The visualization of RNFL and choroidoscleral junction was assessed using an ordinal scoring scale.The paired t-test,intraclass correlation coefficient(ICC),95% limits of agreement(Lo A),and Bland and Altman plots were used to test the agreement of measurements.RESULTS:The visibility score of RNFL obtained with and without EDI was of no significant difference(P=0.532),the visualization of choroidoscleral junction was better using EDI protocol than conventional protocol(P<0.001).Peripapillary RNFL thickness obtained with EDI was slightly thicker than that obtained without EDI(103.25±9.42 μm vs 101.87±8.78 μm,P=0.010).The ICC of the two protocols was excellent with the value of 0.867 to 0.924,the 95% Lo A of global RNFL thickness was between-10.0 to 7.4 μm.Peripapillary choroidal thickness obtained with EDI was slightly thinner than that obtained without EDI(147.23±51.04 μm vs 150.90±51.84 μm,P<0.001).The ICC was also excellent with the value of 0.960 to 0.987,the 95% Lo A of global choroidal thickness was between-12.5 to 19.8 μm.CONCLUSION:Peripapillary circular OCT scan with or without EDI mode shows comparable results in the measurement of peripapillary RNFL and choroidal thickness.
基金supported by the National Natural Science Foundation of China(62375144 and 61875092)Tianjin Foundation of Natural Science(21JCYBJC00260)Beijing-Tianjin-Hebei Basic Research Cooperation Special Program(19JCZDJC65300).
文摘Limited by the dynamic range of the detector,saturation artifacts usually occur in optical coherence tomography(OCT)imaging for high scattering media.The available methods are difficult to remove saturation artifacts and restore texture completely in OCT images.We proposed a deep learning-based inpainting method of saturation artifacts in this paper.The generation mechanism of saturation artifacts was analyzed,and experimental and simulated datasets were built based on the mechanism.Enhanced super-resolution generative adversarial networks were trained by the clear–saturated phantom image pairs.The perfect reconstructed results of experimental zebrafish and thyroid OCT images proved its feasibility,strong generalization,and robustness.
基金supported by the National Natural Science Foundation of China(Grant Nos.62175156,81827807,81770940)Science and Technology Commission of Shanghai Municipality(22S31903000,16DZ0501100)Collaborative Innovation Project of Shanghai Institute of Technology(XTCX2022-27).
文摘Diabetic retinopathy(DR)is one of the major causes of visual impairment in adults with diabetes.Optical coherence tomography angiography(OCTA)is nowadays widely used as the golden criterion for diagnosing DR.Recently,wide-field OCTA(WF-OCTA)provided more abundant information including that of the peripheral retinal degenerative changes and it can contribute in accurately diagnosing DR.The need for an automatic DR diagnostic system based on WF-OCTA pictures attracts more and more attention due to the large diabetic population and the prevalence of retinopathy cases.In this study,automatic diagnosis of DR using vision transformer was performed using WF-OCTA images(12 mm×12 mm single-scan)centered on the fovea as the dataset.WF-OCTA images were automatically classified into four classes:No DR,mild nonproliferative diabetic retinopathy(NPDR),moderate to severe NPDR,and proliferative diabetic retinopathy(PDR).The proposed method for detecting DR on the test set achieves accuracy of 99.55%,sensitivity of 99.49%,and specificity of 99.57%.The accuracy of the method for DR staging reaches up to 99.20%,which has been proven to be higher than that attained by classical convolutional neural network models.Results show that the automatic diagnosis of DR based on vision transformer and WF-OCTA pictures is more effective for detecting and staging DR.
文摘AIM:To measure the difference of intraoperative central macular thickness(CMT)before,during,and after membrane peeling and investigate the influence of intraoperative macular stretching on postoperative best corrected visual acuity(BCVA)outcome and postoperative CMT development.METHODS:A total of 59 eyes of 59 patients who underwent vitreoretinal surgery for epiretinal membrane was analyzed.Videos with intraoperative optical coherence tomography(OCT)were recorded.Difference of intraoperative CMT before,during,and after peeling was measured.Pre-and postoperatively obtained BCVA and spectral-domain OCT images were analyzed.RESULTS:Mean age of the patients was 70±8.13y(range 46-86y).Mean baseline BCVA was 0.49±0.27 log MAR(range 0.1-1.3).Three and six months postoperatively the mean BCVA was 0.36±0.25(P=0.01 vs baseline)and 0.38±0.35(P=0.08 vs baseline)log MAR respectively.Mean stretch of the macula during surgery was 29%from baseline(range 2%-159%).Intraoperative findings of macular stretching did not correlate with visual acuity outcome within 6mo after surgery(r=-0.06,P=0.72).However,extent of macular stretching during surgery significantly correlated with less reduction of CMT at the fovea centralis(r=-0.43,P<0.01)and 1 mm nasal and temporal from the fovea(r=-0.37,P=0.02 and r=-0.50,P<0.01 respectively)3mo postoperatively.CONCLUSION:The extent of retinal stretching during membrane peeling may predict the development of postoperative central retinal thickness,though there is no correlation with visual acuity development within the first 6mo postoperatively.
文摘Dear Editor,The state of the vitreo-retinal interface affects various retinal diseases,and the presence or absence of a posterior vitreous detachment(PVD)is one of the most important factors^([1-5]).As such,various studies studying PVD in relation to retinal disease have been performed^([1-5]).
文摘The parallel spectral-domain optical coherence tomography(PSDOCT) is described for high-speed optical coherence tomography(OCT) without lateral scanning. In this setup, the self-elimination of auto-correlation(AC) interference algorithm was used for eradicating the AC interference and ghost images. However, when performed in free space OCT, this algorithm still generated a weak DC component. The algorithm was improved by adding the background intensity part to compensate for the mutual interference between object and reference arms. The results demonstrate that the DC component can be eradicated. Compared with conventional OCT and complex Fourier-domain optical coherence tomography, the advantages of PSDOCT with the improved algorithm in free space are that it has no moving parts to generate consecutive phase shift, the structure of the object can be reconstructed immediately and automatically, and the speed is approximately 16 times faster than those of the other two in the same case.
基金supported by National Natural Science Foundation of China(NSFC)(61875092 and 11374167)State Key Project of Research and Development Plan(2016YFC0101002)+1 种基金Science and Technology Support Program of Tianjin(17YFZCSY00740)Fundamental Research Funds for the Central Universities of Nankai University(63191203).
文摘Histopathological examination is still the gold standard for diagnoses of oral-maxillofacial lesions,but it is invasive and time-consuming.Optical coherence tomography(OCT)provides a kind of noninvasive,label-free,real-time and high-resolution imaging technology.In this study,in order to assess the feasibility of OCT in oral clinical application,fresh excised tissue specimens from 59 patients undergoing oral-maxillofacial surgery were imaged in detail by using a benchtop sweptsource OCT system.It is shown that different lesions or tissues can be obviously distinguished based on their different microstructural features in OCT images,and the features are similar to those of their corresponding histopathological images.It is proven that OCT has great feasibility and potential as a diagnostic aid for surgeons in oral medicine.
文摘Arterial plaque from a myocardial infarction-prone Watanabe heritable hyperlipidemic (WHHLMI) rabbit is visualized and characterized using a signal to noise ratio enhanced swept-source optical coherence tomography system with a quadrature interferometer (QSS-OCT). A semiconductor optical amplifier is used in the sample arm to amplify the weak signal scattered from arterial plague. Signal to noise ratio improvement are demonstrated in our QSS-OCT system. This finding results into an increase of the penetration depth possible in OCT images, from 1 mm to 2 mm. Preliminary results show that vulnerable plaque with fibrous cap, macrophage accumulations and calcification in the arterial tissue are measurable with our QSS-OCT system.
文摘Starting with introduction of basic concept of optical coherence tomography(OCT) techniques,this paper focuses on a detailed review of ophthalmic OCT instruments and their clinical applications. As one of the most important inventions of ophthalmology instruments,OCT has become a standard imaging tool for daily ophthalmic diagnosis. The imaging capability has been significantly improved during the past ~ 30 years. In this article,several representing systems which have made significant contributions to OCT developments will be reviewed in details. For each system,the system configuration will be discussed first,follow ed by a brief introduction of their clinical applications. The review concludes with discussions on potential directions of OCT developments and expectations for further improvements of OCT imaging capabilities.
基金Supported by National Science Foundation of China(No.81800878)Interdisciplinary Program of Shanghai Jiao Tong University(No.YG2017QN24)+1 种基金Key Technological Research Projects of Songjiang District(No.18sjkjgg24)Bethune Langmu Ophthalmological Research Fund for Young and Middle-aged People(No.BJ-LM2018002J)
文摘AIM: To explore a segmentation algorithm based on deep learning to achieve accurate diagnosis and treatment of patients with retinal fluid.METHODS: A two-dimensional(2D) fully convolutional network for retinal segmentation was employed. In order to solve the category imbalance in retinal optical coherence tomography(OCT) images, the network parameters and loss function based on the 2D fully convolutional network were modified. For this network, the correlations of corresponding positions among adjacent images in space are ignored. Thus, we proposed a three-dimensional(3D) fully convolutional network for segmentation in the retinal OCT images.RESULTS: The algorithm was evaluated according to segmentation accuracy, Kappa coefficient, and F1 score. For the 3D fully convolutional network proposed in this paper, the overall segmentation accuracy rate is 99.56%, Kappa coefficient is 98.47%, and F1 score of retinal fluid is 95.50%. CONCLUSION: The OCT image segmentation algorithm based on deep learning is primarily founded on the 2D convolutional network. The 3D network architecture proposed in this paper reduces the influence of category imbalance, realizes end-to-end segmentation of volume images, and achieves optimal segmentation results. The segmentation maps are practically the same as the manual annotations of doctors, and can provide doctors with more accurate diagnostic data.
基金financial supports from the National Natural Science Foundation of China(Grant No.81927805)Shenzhen Municipal Science and Technology Plan Project,China(Grant No.JCYJ20160427183803458)。
文摘Current gradient-index(GRIN)lens based proximal-driven intracoronary optical coherence tomography(ICOCT)probes consist of a spacer and a GRIN lens with large gradient constant.This design provides great flexibility to control beam profiles,but the spacer length should be well controlled to obtain desired beam profiles and thus it sets an obstacle in mass catheter fabrication.Besides,although GRIN lens with large gradient constant can provide tight focus spot,it has short depth of focus and fast-expanded beam which leads to poor lateral resolution for deep tissue.In this paper,a type of spacer-removed probe is demonstrated with a small gradient constant GRIN lens.This design simplifies the fabrica-tion process and is suitable for mass production.The output beam of the catheter is a narrow nearly collimated light beam,referred to as pencil beam here.The full width at half maximum beam size varies from 35.1μm to 75.3μm in air over 3-mm range.Probe design principles are elaborated with probe/catheter fabrication and performance test.The in vivo imaging of the catheter was verified by a clinical ICOCT system.Those results prove that this novel pencil-beam scanning catheter is potentially a good choice for ICOCT systems.
基金the National Natural Science Foundation of China(61627827,61331001,81630046and 91539127)the Science and Technology Planning Project of Guangdong Province,China(2015B020233016,2014B020215003and 2014A020215031)+1 种基金the Distinguished Young Teacher Project in Higher Education of Guangdong,China(YQ2015049)the Science and Technology Youth Talent for Special Project of Guangdong,China(2015TQ01X882).
文摘All-optically integrated photoacoustic(PA)and optical coherence tomography(OCT)dualmode imaging technology that could o®er comprehensive pathological information for accurate diagnosis in clinic has gradually become a promising imaging technology in the aspect of biomedical imaging during the recent years.This review refers to the technology aspects of alloptical PA detection and system evolution of optically integrated PA and OCT,including Michelson interferometer dual-mode imaging system,Fabry–Perot(FP)interferometer dualmode imaging system and Mach–Zehnder interferometer dual-mode imaging system.It is believed that the optically integrated PA and OCT has great potential applications in biomedical imaging.
文摘Doppler Optical Coherence Tomography(DOCT)is a noninvasive optical diagnostic technique,which is well suited for the quantitative mapping of microflow velocity profiles and the analysis of flow-vessel interactions.The noninvasive imaging and quantitative analysis of blood flow in the complex-structured vascular bed is required in many biomedical applications,including those where the determination of mechanical properties of vessels or the knowledge of the mechanic interactions between the flow and the housing medium plays a key role.The change of microvessel wall elasticity could be a potential indicator of cardiovascular disease at the very early stage,whilst monitoring the blood flow dynamics and associated temporal and spatial variations in vessel’s wall shear stress could help predicting the possible rupture of atherosclerotic plaques.The results of feasibility studies of application of DOCT for the evaluation of mechanical properties of elastic vessel model are presented.The technique has also been applied for imaging of sub-cranial rat blood flow in vivo.
基金supported by the National Natural Science Foundation of China(No.12002215)the China Postdoctoral Science Foundation(No.2022T150437)the National Key Research and Development Program of China(No.2019YFC1511102)。
文摘Optical coherence tomography(OCT)allows a direct and precise measurement of laser welding depth by coaxially measuring the keyhole depth and can be used for process monitoring and control.When OCT measurement was taken during single-beam laser welding,the keyhole instability of aluminum welding resulted in highly scattered OCT data and complicated the welding depth extraction methods.As a combination of an inner core beam and an outer ring beam,a novel adjustable ring mode(ARM)laser for producing a stable keyhole was applied to the OCT measurement.Different ARM laser power arrangements were conducted on aluminum and copper.The results indicated that the ring beam greatly improved the stability of the core beam-induced keyhole,and smooth welding depth can be extracted from the concentrated OCT data.
基金Supported by facility supports of the VA Boston Healthcare System,NIH grants R01-CA075289-21(JGF and HM)Air Force Office of Scientific Research contract FA9550-15-1-0473(JGF)
文摘BACKGROUND Chronic radiation proctopathy(CRP) occurs as a result of pelvic radiation therapy and is associated with formation of abnormal vasculature that may lead to persistent rectal bleeding. While incidence is declining due to refinement of radiation delivery techniques, CRP remains one of the major complications of pelvic radiation therapy and significantly affects patient quality of life.Radiofrequency ablation(RFA) is an emerging treatment modality for eradicating abnormal vasculature associated with CRP. However, questions remain regarding CRP pathophysiology and optimal disease management.AIM To study feasibility of optical coherence tomography angiography(OCTA) for investigating subsurface vascular alterations in CRP and response to RFA treatment.METHODS Two patients with normal rectum and 8 patients referred for, or undergoing endoscopic RFA treatment for CRP were imaged with a prototype ultrahighspeed optical coherence tomography(OCT) system over 15 OCT/colonoscopy visits(2 normal patients, 5 RFA-na?ve patients, 8 RFA-follow-up visits). OCT and OCTA was performed by placing the OCT catheter onto the dentate line and rectum without endoscopic guidance. OCTA enabled depth-resolved microvasculature imaging using motion contrast from flowing blood, withoutrequiring injected dyes. OCTA features of normal and abnormal microvasculature were assessed in the mucosa and submucosa. Blinded reading of OCTA images was performed to assess the association of abnormal rectal microvasculature with CRP and RFA treatment, and rectal telangiectasia density endoscopic scoring.RESULTS OCTA/OCT images are intrinsically co-registered and enabled depth-resolved visualization of microvasculature in the mucosa and submucosa. OCTA visualized normal vascular patterns with regular honeycomb patterns vs abnormal vasculature with distorted honeycomb patterns and ectatic/tortuous microvasculature in the rectal mucosa. Normal arterioles and venules < 200 μm in diameter versus abnormal heterogenous enlarged arterioles and venules > 200μm in diameter were visualized in the rectal submucosa. Abnormal mucosal vasculature occurred in 0 of 2 normal patients and 3 of 5 RFA-na?ve patients,while abnormal submucosal vasculature occurred more often, in 1 of 2 normal patients and 5 of 5 RFA-na?ve patients. After RFA treatment, vascular abnormalities decreased, with abnormal mucosal vasculature observed in 0 of 8 RFA-follow-up visits and abnormal submucosal vasculature observed in only and 2 of 8 RFA-follow-up visits.CONCLUSION OCTA visualizes depth-resolved microvascular abnormalities in CRP, allowing assessment of superficial features which are endoscopically visible as well as deeper vasculature which cannot be seen endoscopically. OCTA/OCT of the rectum can be performed in conjunction with, or independently from endoscopy.Further studies are warranted to investigate if OCTA/OCT can elucidate pathophysiology of CRP or improve management.
文摘AIM: To assess the repeatability of measuring optic nerve head(ONH) parameters using the Cirrus optical coherence tomography(OCT), as well as to assess the effect of head tilt on these measurements.METHODS: Thirty healthy participants with no evidence of glaucoma were recruited for the study. Visual acuity, intraocular pressure, standard automated perimetry and ocular examination were performed for each participant. One eye was then randomly selected and scanned undilated with the Cirrus OCT in 3 positions(neutral, 30° right tilt and 30° left tilt).RESULTS: Data collected from 29 eyes were used for analysis. One patient was omitted due to poor scan quality. The repeatability of the ONH parameters was analyzed using analysis of variance, coefficient of variation(COV) and intraclass correlation coefficient(ICC). Analysis of variance showed no statistically significant difference between 3 scans in a single position. There was good agreement between measurements(ICC 0.919-0.996, COV 1.94%-5.48%).Even with the presence of head tilt, repeated scans in the 3 positions showed good agreement as well(ICC 0.888-0.996, COV 2.04%-5.39%).CONCLUSION: Serial measurements of ONH parameters using the Cirrus OCT are found to have good repeatability. The ONH parameters with Cirrus OCT also maintain good repeatability despite head tilt.