The effects of the ionic wind on the heat transfer rate from a heated vertical flat plate are described. The ionic wind is induced by three different types of discharge, corona discharge, dielectric barrier discharge ...The effects of the ionic wind on the heat transfer rate from a heated vertical flat plate are described. The ionic wind is induced by three different types of discharge, corona discharge, dielectric barrier discharge (DBD) and dc glow discharge. The heat transfer coefficients for the heated copperplate under free convection conditions with and without an ionic wind are obtained by measuring the temperature and the heating power of the copper plate. It has been proved that the convective heat transfer coefficients increase by several times with the help of the ionic wind. With the ionic wind induced by a uniform dc glow discharge, the heat transfer coefficient of the heated copper plate is highly enhanced compared with those induced by a corona discharge or DBD. With the use of DBD, the breakdown voltage is increased significantly, which is helpful in avoiding a breakdown when heat transfer is enhanced by the ionic wind. In addition, it makes the application of the ionic wind much safer.展开更多
Enhanced pool boiling heat transfer of the porous structure is critical to the thermal management technology.In this paper,pool boiling heat transfer experiments are performed on copper foam welded surfaces in de-ioni...Enhanced pool boiling heat transfer of the porous structure is critical to the thermal management technology.In this paper,pool boiling heat transfer experiments are performed on copper foam welded surfaces in de-ionized water to investigate the effects of basic parameters of copper foam on heat transfer enhancement.Boiling phenomenon is observed to facilitate the understanding of enhancement mechanism.The results show that copper foam welded surfaces can significantly enhance the pool boiling heat transfer performance,reduce the boiling incipience temperature by 7-9℃,and reach two times heat transfer coefficient compared with smooth plain surfaces due to numerous nucleation sites,extended surface areas,and enhanced turbulent effect.Pore density and thickness of foam have two side effects on heat transfer.展开更多
Presents a set of data for flow and heat transfer of finned-tube bundle under the condition of high air flow velocity. Air flow and heat transfer over a 4 × 4 ( columns × rows) finned-tube heat exchanger w...Presents a set of data for flow and heat transfer of finned-tube bundle under the condition of high air flow velocity. Air flow and heat transfer over a 4 × 4 ( columns × rows) finned-tube heat exchanger with rectangular fins was investigated experimentally in a wind tunnel with constant wall temperatures condition. The air flow velocity based on the minimum flow cross-section area over flow channel ranged from 13.8 to 50. 2 m/s, the heal transfer rate ranged from 21.8 to47. 1 kW, and the air temperatures increase ranged from 10. 9 to 19. 8 ℃. The present results were compared with results calculated from correlations proposed by CSPE. For air flow velocity less than 25 m/s, these two results of heat transfer agreed well with each other, whereas for larger velocity, our test data disagreed with the CSPE correlations. For the friction factor, present data are much higher than the predicted results in the whole range. Finally, correlations for friction factors and heat transfer coefficients are DrODosed based on the experimental results.展开更多
The heat generation of electronic devices is increasing dramatically,which causes a serious bottleneck in the thermal management of electronics,and overheating will result in performance deterioration and even device ...The heat generation of electronic devices is increasing dramatically,which causes a serious bottleneck in the thermal management of electronics,and overheating will result in performance deterioration and even device damage.With the development of micro-machining technologies,the microchannel heat sink(MCHS)has become one of the best ways to remove the considerable amount of heat generated by high-power electronics.It has the advantages of large specific surface area,small size,coolant saving and high heat transfer coefficient.This paper comprehensively takes an overview of the research progress in MCHSs and generalizes the hotspots and bottlenecks of this area.The heat transfer mechanisms and performances of different channel structures,coolants,channel materials and some other influencing factors are reviewed.Additionally,this paper classifies the heat transfer enhancement technology and reviews the related studies on both the single-phase and phase-change flow and heat transfer.The comprehensive review is expected to provide a theoretical reference and technical guidance for further research and application of MCHSs in the future.展开更多
Extended experiments were conducted on the oscillation characteristics of merged liquid slugs in a horizontally oriented polymer pulsating heat pipe(PHP).The PHP’s serpentine channel comprised 14 parallel channels wi...Extended experiments were conducted on the oscillation characteristics of merged liquid slugs in a horizontally oriented polymer pulsating heat pipe(PHP).The PHP’s serpentine channel comprised 14 parallel channels with a width of 1.3 mm and a height of 1.1 mm.The evaporator and condenser sections were 25 and 50 mm long,respectively,and the adiabatic section in between was 75mmlong.Using a plastic 3D printer and semi-transparent filament made from acrylonitrile butadiene styrene,the serpentine channel was printed directly onto a thin polycarbonate sheet to form the PHP.The PHP was charged with hydrofluoroether-7100.In the experiments,the evaporator section was heated,and the condenser section was cooled using high-temperature and low-temperature thermostatic baths,respectively.Flow patterns of the working fluid were obtained with temperature distributions of the PHP.A mathematical model was developed to analyze the flow patterns.Themerged liquid slugs were observed in every two channels,and their oscillation characteristics were found to be approximately the same in time and space.It was also found that the oscillations of the merged liquid slugs became slower,but the heat transfer rate of the PHP increased with a decrease in the filling ratio of the working fluid.This is because vapor condensation was enhanced in vapor plugs as the filling ratio decreased.However,the filling ratio had a lower limit,and the heat transfer rate was maximum when the filling ratio was 40.6%in the present experimental range.展开更多
The flow characteristics of shell-side fluid in the tube-and-shell heat exchangers with trisection helical baffles with 35° inclined angles are numerically analyzed. The secondary flow distribution of the fluid i...The flow characteristics of shell-side fluid in the tube-and-shell heat exchangers with trisection helical baffles with 35° inclined angles are numerically analyzed. The secondary flow distribution of the fluid in the shell-side channel is focused on. The results on meridian planes indicate that in the shell-side channel, the center part of fluid has an outward tendency because of the centrifugal force, and the peripheral region fluid has an inward tendency under the centripetal force. So in a spiral cycle, the fluid is divided into the upper and lower beams of streamlines, at the same time the Dean vortices are formed near the left baffle, and then the fluid turns to centripetal flow near the right baffle. Finally the two beams of streamlines merge in the main flow. The results of a number of parallel slices between two parallel baffles with the same sector in a swirl cycle also show the existence of the secondary flow and some backward flows at the V-gaps of the adjacent baffles. The secondary flows have a positive effect on mixing fluid by promoting the momentum and mass exchange between fluid particles near the tube wall and in the main stream, and thus they will enhance the heat transfer of the helix heat exchanger.展开更多
A mathematical model was established for condensation on surfaces of verticalcorrugated plates based on the mechanism of heat transfer enhancement to thin down the liquid filmdue to surface tension effect between corr...A mathematical model was established for condensation on surfaces of verticalcorrugated plates based on the mechanism of heat transfer enhancement to thin down the liquid filmdue to surface tension effect between corrugated plate surfaces and liquid films. The relative heattransfer coefficients of condensation on corrugation plates were calculated in contrast withequivalent vertical plane ones. The heat transfer enhancement effects for the main geometricparameters such as pitch, height, corrugation angle, tilt angle, and fillet radii of corrugationswere analyzed to guide the optimization of corrugation structure for application. A two-scalecorrugation is suggested, which can compromise both the enhanced heat transfer effect and adequatecross section area for flows, and it makes the heat transfer coefficient 1 to 2 times more than thatof an equivalent plane one.展开更多
A novel strip-coil-baffle structure used to enhance heat transfer and support the tube bundle for a tube-shell heat exchanger is proposed. The new structure can sleeve the tubes in bundle alternatively to create a vor...A novel strip-coil-baffle structure used to enhance heat transfer and support the tube bundle for a tube-shell heat exchanger is proposed. The new structure can sleeve the tubes in bundle alternatively to create a vortex flow in a heat exchanger. The numerical simulation on the flow and heat transfer characteristics for this new structure heat exchanger is conducted. The computational domain consists of two strip-coil sleeved tubes and two bare tubes oppositely placed at each comer of a square. The velocity and temperature fields in such strip-coil-baffled channel are simulated using FLUENT software. The effects of the strip-coil-baffles on heat transfer enhancement and flow resistance in relation to the Reynolds number are analyzed. The results show that this new structure bundle can enhance the heat transfer coefficient up to a range of 40% to 55% in comparison with a bare tube bundle; meanwhile, higher flow resistance is also accompanied. It is believe that the strip-coil- baffled heat exchanger should have promising applications in many industry fields.展开更多
The physical models of the outer and inner half coil jackets were simplified to two types of coiled ducts.The mathematic models of incompressible fluid at the condition of laminar flow and heat transfer in the two typ...The physical models of the outer and inner half coil jackets were simplified to two types of coiled ducts.The mathematic models of incompressible fluid at the condition of laminar flow and heat transfer in the two types of jackets for cooling process reactor were set up and solved by the semi-implicit method for pressure linked equa-tions consistent (SIMPLEC) algorithm based on a control volume method.The flow and temperature fields were given and the effects of Dean and Prandtl numbers on flow and heat transfer were studied.The results show that flow in the inner half coil jacket is found to exhibit transition of secondary flow pattern from two vortices to four vortices when the Dean number increases,but that in the outer half coil jacket is not found.The critical Dean num-ber is about 96.The inner half coil jacket has stronger heat transfer ability than the outer half coil jacket and this superiority is more evident with larger Prandtl number.However,as the Dean number is greater than 105,the flow resistance enhances more severely in the inner jacket than the outer jacket.For both jackets,the centers of the heated wall are the poorest for heat transfer.展开更多
This paper deals with the experimental investigation on Nusselt number,friction factor and thermal en-hancement factor of a double pipe heat exchanger equipped with twisted tape consisting wire nails(WN-TT) and plain ...This paper deals with the experimental investigation on Nusselt number,friction factor and thermal en-hancement factor of a double pipe heat exchanger equipped with twisted tape consisting wire nails(WN-TT) and plain twisted tapes(P-TT) with three different twist ratios of y 2.0,4.4 and 6.0. Test runs are conducted using the water as the working fluid with Reynolds number range between 2000 and 12000 for WN-TT and P-TT. It is found that Nusselt number,friction factor and thermal enhancement factor in the tube equipped with WN-TT appreciably higher than those in the tube fitted with P-TT and plain tube. Over the range considered Nusselt number,friction factor and thermal enhancement factor in a tube with WN-TT are respectively,1.08 to 1.31,1.1 to 1.75 and 1.05 to 1.13 times of those in tube with P-TT. The better performance of WN-TT is due to combined effects of the follow-ing factors:(1) common swirling flow generated by P-TT,(2) additional turbulence offered by the wire nails. Em-pirical correlations for Nusselt number,friction factor and thermal enhancement factor are also formulated from the experimental results of WN-TT and P-TT.展开更多
The influences of circular-ring turbulators (CRT) and twisted tape (TT) swirl generators on the heat transfer enhancement, pressure drop and thermal performance factor characteristics in a round tube are reported....The influences of circular-ring turbulators (CRT) and twisted tape (TT) swirl generators on the heat transfer enhancement, pressure drop and thermal performance factor characteristics in a round tube are reported. The circular-ring turbulators were individually employed and together with the twisted tape swirl generators in the heated section of the tube. Three different pitch ratios (I/D = 1.0, 1.5, and 2.0) of the CRT and three different twist ratios (y/W= 3, 4, and 5) of the TT were introduced. The experiments were conducted using air as the working fluid under a uniform wall heat flux condition, for the Reynolds number between 6000 and 20000. The experimental results reveal that the heat transfer rate, friction factor and thermal performance factor of the combined CRT and qT are considerably higher than those of CRT alone. For the range examined, the Sncreases of mean Nusselt number, friction factor and thermal performance, in the tube equipped with combined devices, respectively, are 25.8%, 82.8% and 6.3% over those in the tube with the CRT alone. The highest thermal performance factor of 1.42 is found for the combined device consisting of the CRT with l/D = 1.0 and TT with y/W= 3. The correlations of the Nusselt number, friction factor and thermal performance factor of the tubes with combined devices are also developed in terms of Reynolds number, Prandtl number, twist ratio and pitch ratio.展开更多
Heat transfer,friction factor and thermal enhancement factor characteristics of a double pipe heat exchanger fitted with square-cut twisted tapes(STT) and plain twisted tapes(PTT) are investigated experimentally u...Heat transfer,friction factor and thermal enhancement factor characteristics of a double pipe heat exchanger fitted with square-cut twisted tapes(STT) and plain twisted tapes(PTT) are investigated experimentally using the water as working fluid.The tapes(STT and PTT) have three twist ratios(y=2.0,4.4 and 6.0) and the Reynolds number ranges from 2000 to 12000.The experimental results reveal that heat transfer rate,friction factor and thermal enhancement factor in the tube equipped with STT are significantly higher than those fitted with PTT. The additional disturbance and secondary flow in the vicinity of the tube wall generated by STT are higher compared to that induced by the PTT is referred as the reason for better performance.Over the range considered,the Nusselt number,friction factor and thermal enhancement factor in a tube with STT are respectively,1.03 to 1.14,1.05 to 1.25 and 1.02 to 1.06 times of those in tube with PTT.An empirical correlation is also formulated to match with experimental data of Nusselt number and friction factor for STT and PTT.展开更多
This paper presents the heat transfer characteristics of A1203-water nanofluid in a coiled agitated vessel with propeller agitator. The experimental study was conducted using 0.10%, 0.20% and 0.30% volume concentra ti...This paper presents the heat transfer characteristics of A1203-water nanofluid in a coiled agitated vessel with propeller agitator. The experimental study was conducted using 0.10%, 0.20% and 0.30% volume concentra tion of A1203-water nanofluids. The results showed considerable enhancement of convective heat transfer using the nanofluids. The empirical correlations developed for Nusselt number in terms of Reynolds number, Prandtl number, viscosity ratio and volume concentration fit with the experimental data within ±10%. The heat transfer characteris tics were also simulated using computational fluid dynamics using FLUENT software with the standard ke model and multiple reference frame were adopted. The computational fluid dynamics (CFD) predicted Nusselt number agrees well with the experimental value and the discrepancy is found to be less than +8%.展开更多
The backward-facing step is a critical problem existing in many engineering and industrial applications.In this study,a semi-porous baffle(the root of the baffle is a porous medium and the tip is solid) is placed behi...The backward-facing step is a critical problem existing in many engineering and industrial applications.In this study,a semi-porous baffle(the root of the baffle is a porous medium and the tip is solid) is placed behind the step.The effects of the length of the porous part,and the baffle location on the energy transfer and pressure drop are studied in different Reynolds numbers(Re=100,200,300,400,500).The effect of the Darcy number of the porous medium on the aforementioned parameters is also investigated.Both the local maximum and average relative Nusselt numbers(divided by the Nusselt of the base case with no baffle at the same Reynolds) and relative pressure drop(calculated as the relative Nusselt number) are reported.The results show that by adoption of the proper length of the porous medium,the average relative and maximum local Nusselt numbers could be enhanced by 20% and 90%,respectively.Low permeable porous media give better energy transfer.For example,porous media with Da=10^(-5) give 30% better maximum local Nusselt number and about 7% higher average Nusselt number with respect to the same case with Da=10^(-2).展开更多
The single-phase pressure drop and heat transfer in a rotor-assembled strand inserted tube were measured using water as the working fluid.Experiment using a smooth tube was carried out to calibrate the experimental sy...The single-phase pressure drop and heat transfer in a rotor-assembled strand inserted tube were measured using water as the working fluid.Experiment using a smooth tube was carried out to calibrate the experimental system and the data reduction method.In the experiment,fixed mounts were used to eliminate the entrance effect. The experimental results of smooth tube show that employment of fixed mounts leads to a visible bias of friction factor at relative low Reynolds numbers,although it does not significantly affect the Nusselt numbers.The measured data of inserted tube reveal that rotor-assembled strand can significantly improve heat transfer with the Nusselt number increased by 101.6%-106.6%and the overall heat transfer coefficient increased by 58.1%-67.4%within the Reynolds number range of 20000 to 36000.Meanwhile,friction factor increases by 52.2%-84.2%within the same Reynolds number range.The correlations of Nusselt number and friction factor as function of the Reynolds number and Prandtl number were determined through multivariant linear normal regression.展开更多
The paper presents a 3D numerical simulation of turbulent heat transfer and flow characteristics in converging-diverging tubes (CDs) and converging-diverg)ng tubes.equi.pped with twin counter-swirling twisted tapes...The paper presents a 3D numerical simulation of turbulent heat transfer and flow characteristics in converging-diverging tubes (CDs) and converging-diverg)ng tubes.equi.pped with twin counter-swirling twisted tapes (CDTs). The effects of Reynolds number (Re= 10000-20000), pitch length (P= 11.25, 22.5 mm), rib height (e = 0.5, 0.8, 1.1 ram), pitch ratio (8= 1 " 8, 5 " 4, 8 " 1), gap distance between twin t)visted tapes (b = 0.5, 4.5, 8.5 mm) and tape number (n = 2, 3, 4, 5, 6) on Nusselt number (Nu), Iriction tactor 0') and thermal enhancement factor (r/) are investigated under uniform heat flux conditions,using water as working fluid. In order to illustrate the heat transter and tlu^d tlow mechamsms, flow structures m ~StJs and ~SDIs are presented. The obtained results reveal that all geometric parameters have important effects on the thermal performance of CD and CDT, and both CD and CDT show better thermal performance than plain tube at the constant pumping power. It is also found that the increases in the Nusselt number and friction factor for CDT are, respectively, up to 6.3%-35.7% and 1.75-5.3 times of thecorresponding bare CD. All CDTs have good thermal perbrmance with greater than 1 which indicates that the compound heat transfer technique of CDT is commendable for the maximum enhanced heat transfer rate.展开更多
The application of vortex generators in tube-finned heat exchangers is very universal.The vortex generators can generate secondary flow,and as we all know secondary flow can obviously strengthen heat transfer.To use v...The application of vortex generators in tube-finned heat exchangers is very universal.The vortex generators can generate secondary flow,and as we all know secondary flow can obviously strengthen heat transfer.To use vortex generators much more efficiently in the circle tube-finned heat exchangers,the intensity correlation study between secondary flow and heat transfer is needed.22 different structures of circle tube-finned heat exchangers were numerically studied,including the plain fin cases and the cases with vortex generators.In addition,the influence of fin spacing,transverse and longitudinal tube pitch,heights and attack angle of vortex generators,positions of vortex generators and shape of vortex generators on heat transfer and fluid flow are studied,too.The non-dimensional parameter Se is applied to quantify the secondary flow intensity.The results show that Se can describe the secondary flow intensity very well.There is very close corresponding relationship between overall averaged Nu and volumetrically averaged Se for all the researched cases and the relational expression is obtained.However,there is no one-to-one correlation not only between Re and f but also between volumetrically averaged Se and f for all the studied cases.展开更多
Experimental and numerical investigations have been conducted to study turbulent flow of water and heat transfer characteristics in a rectangular channel with discontinuous crossed ribs and grooves.The tests investiga...Experimental and numerical investigations have been conducted to study turbulent flow of water and heat transfer characteristics in a rectangular channel with discontinuous crossed ribs and grooves.The tests investigated the overall heat transfer performance and friction factor in ribbed and ribbed-grooved channels with rib angle of 30°.The experimental results show that the overall thermo-hydraulic performance for ribbed-grooved channel is increased by 10%-13.6% when compared to ribbed channel.The investigation on the effects of different rib angles and rib pitches on heat transfer characteristics and friction factor in ribbed-grooved channel was carried out using Fluent with SST(shear-stress transport) k-ω turbulence model.The numerical results indicate that the case for rib angle of 45° shows the best overall thermo-hydraulic performance,about 18%-36% higher than the case for rib angle of 0°.In addition,the flow patterns and local heat transfer characteristics for ribbed and ribbed-grooved channels based on the numerical simulation were also analyzed to reveal the mechanism of heat transfer enhancement.展开更多
This study examines the heat transfer enhancement from a horizontal rectangular fin embedded with triangular perforations (their bases parallel and toward the fin tip) under natural convection. The fin's heat dissi...This study examines the heat transfer enhancement from a horizontal rectangular fin embedded with triangular perforations (their bases parallel and toward the fin tip) under natural convection. The fin's heat dissipation rate is compared to that of an equivalent solid one. The parameters considered are geometrical dimensions and thermal properties of the fin and the perforations. The gain in the heat transfer enhancement and the fin weight reduction due to the perforations are considered. The study shows that the heat dissipation from the perforated fin for a certain range of triangular perforation dimensions and spaces between perforations result in improvement in the heat transfer over the equivalent solid fin. The heat transfer enhancement of the perforated fin increases as the fin thermal conductivity and its thickness are increased.展开更多
Heat transfer enhancement in vertical tubes plays an important role on the thermal performance of many heat exchangers and thermal devices.In this work,laminar mixed convection of airflow in a vertical dimpled tube wa...Heat transfer enhancement in vertical tubes plays an important role on the thermal performance of many heat exchangers and thermal devices.In this work,laminar mixed convection of airflow in a vertical dimpled tube was numerically investigated.Three-dimensional elliptical governing equations were solved using the finite-volume technique.For a given dimpled pitch,the effects of three different dimple heights(h/D=0.013,0.027,0.037) have been studied at different Richardson numbers(0.1,1.0 and 1.5).The generated vortex in the vicinity of the dimple destructs the thermal boundary layer and enhances the heat transfer.Therefore,lower wall temperature is seen where the dimples are located.Fluid flow velocity at the near-wall region significantly increases because of buoyancy forces with the increase of Richardson numbers.Such an acceleration at the near-wall region makes the dimples more effective at higher Richardson number.Using a dimpled tube enhances the heat transfer coefficient.However,the pressure drop is not important.For instance,in the case of Ri=1.5 and h/D=0.037,20% gains in the heat transfer enhancement only costs2.5% in the pressure loss.In general,it is recommended using a dimpled tube where the effects of buoyancy forces are important.展开更多
文摘The effects of the ionic wind on the heat transfer rate from a heated vertical flat plate are described. The ionic wind is induced by three different types of discharge, corona discharge, dielectric barrier discharge (DBD) and dc glow discharge. The heat transfer coefficients for the heated copperplate under free convection conditions with and without an ionic wind are obtained by measuring the temperature and the heating power of the copper plate. It has been proved that the convective heat transfer coefficients increase by several times with the help of the ionic wind. With the ionic wind induced by a uniform dc glow discharge, the heat transfer coefficient of the heated copper plate is highly enhanced compared with those induced by a corona discharge or DBD. With the use of DBD, the breakdown voltage is increased significantly, which is helpful in avoiding a breakdown when heat transfer is enhanced by the ionic wind. In addition, it makes the application of the ionic wind much safer.
基金supported by the National Natural Science Foundation of China(No.52075249)the Foundation of Jiangsu Key Laboratory of Bionic Functional Materials(No.NJ2020026)
文摘Enhanced pool boiling heat transfer of the porous structure is critical to the thermal management technology.In this paper,pool boiling heat transfer experiments are performed on copper foam welded surfaces in de-ionized water to investigate the effects of basic parameters of copper foam on heat transfer enhancement.Boiling phenomenon is observed to facilitate the understanding of enhancement mechanism.The results show that copper foam welded surfaces can significantly enhance the pool boiling heat transfer performance,reduce the boiling incipience temperature by 7-9℃,and reach two times heat transfer coefficient compared with smooth plain surfaces due to numerous nucleation sites,extended surface areas,and enhanced turbulent effect.Pore density and thickness of foam have two side effects on heat transfer.
基金Sponsored by the National Natural Science Special Foundation of China(Grant No.50323001)Xi'an Jiaotong University Doctoral Foundation forTeacher.
文摘Presents a set of data for flow and heat transfer of finned-tube bundle under the condition of high air flow velocity. Air flow and heat transfer over a 4 × 4 ( columns × rows) finned-tube heat exchanger with rectangular fins was investigated experimentally in a wind tunnel with constant wall temperatures condition. The air flow velocity based on the minimum flow cross-section area over flow channel ranged from 13.8 to 50. 2 m/s, the heal transfer rate ranged from 21.8 to47. 1 kW, and the air temperatures increase ranged from 10. 9 to 19. 8 ℃. The present results were compared with results calculated from correlations proposed by CSPE. For air flow velocity less than 25 m/s, these two results of heat transfer agreed well with each other, whereas for larger velocity, our test data disagreed with the CSPE correlations. For the friction factor, present data are much higher than the predicted results in the whole range. Finally, correlations for friction factors and heat transfer coefficients are DrODosed based on the experimental results.
基金supported by the National Natural Science Foundation of China(Grant Nos.U20A20301,51825601)。
文摘The heat generation of electronic devices is increasing dramatically,which causes a serious bottleneck in the thermal management of electronics,and overheating will result in performance deterioration and even device damage.With the development of micro-machining technologies,the microchannel heat sink(MCHS)has become one of the best ways to remove the considerable amount of heat generated by high-power electronics.It has the advantages of large specific surface area,small size,coolant saving and high heat transfer coefficient.This paper comprehensively takes an overview of the research progress in MCHSs and generalizes the hotspots and bottlenecks of this area.The heat transfer mechanisms and performances of different channel structures,coolants,channel materials and some other influencing factors are reviewed.Additionally,this paper classifies the heat transfer enhancement technology and reviews the related studies on both the single-phase and phase-change flow and heat transfer.The comprehensive review is expected to provide a theoretical reference and technical guidance for further research and application of MCHSs in the future.
基金supported by JSPS KAKENHI Grant Number 22K03947.
文摘Extended experiments were conducted on the oscillation characteristics of merged liquid slugs in a horizontally oriented polymer pulsating heat pipe(PHP).The PHP’s serpentine channel comprised 14 parallel channels with a width of 1.3 mm and a height of 1.1 mm.The evaporator and condenser sections were 25 and 50 mm long,respectively,and the adiabatic section in between was 75mmlong.Using a plastic 3D printer and semi-transparent filament made from acrylonitrile butadiene styrene,the serpentine channel was printed directly onto a thin polycarbonate sheet to form the PHP.The PHP was charged with hydrofluoroether-7100.In the experiments,the evaporator section was heated,and the condenser section was cooled using high-temperature and low-temperature thermostatic baths,respectively.Flow patterns of the working fluid were obtained with temperature distributions of the PHP.A mathematical model was developed to analyze the flow patterns.Themerged liquid slugs were observed in every two channels,and their oscillation characteristics were found to be approximately the same in time and space.It was also found that the oscillations of the merged liquid slugs became slower,but the heat transfer rate of the PHP increased with a decrease in the filling ratio of the working fluid.This is because vapor condensation was enhanced in vapor plugs as the filling ratio decreased.However,the filling ratio had a lower limit,and the heat transfer rate was maximum when the filling ratio was 40.6%in the present experimental range.
基金The National Natural Science Foundation of China (No.50976022)the National Key Technology R&D Program of China during the 11th Five-Year Plan Period (No.2008BAJ12B02)
文摘The flow characteristics of shell-side fluid in the tube-and-shell heat exchangers with trisection helical baffles with 35° inclined angles are numerically analyzed. The secondary flow distribution of the fluid in the shell-side channel is focused on. The results on meridian planes indicate that in the shell-side channel, the center part of fluid has an outward tendency because of the centrifugal force, and the peripheral region fluid has an inward tendency under the centripetal force. So in a spiral cycle, the fluid is divided into the upper and lower beams of streamlines, at the same time the Dean vortices are formed near the left baffle, and then the fluid turns to centripetal flow near the right baffle. Finally the two beams of streamlines merge in the main flow. The results of a number of parallel slices between two parallel baffles with the same sector in a swirl cycle also show the existence of the secondary flow and some backward flows at the V-gaps of the adjacent baffles. The secondary flows have a positive effect on mixing fluid by promoting the momentum and mass exchange between fluid particles near the tube wall and in the main stream, and thus they will enhance the heat transfer of the helix heat exchanger.
文摘A mathematical model was established for condensation on surfaces of verticalcorrugated plates based on the mechanism of heat transfer enhancement to thin down the liquid filmdue to surface tension effect between corrugated plate surfaces and liquid films. The relative heattransfer coefficients of condensation on corrugation plates were calculated in contrast withequivalent vertical plane ones. The heat transfer enhancement effects for the main geometricparameters such as pitch, height, corrugation angle, tilt angle, and fillet radii of corrugationswere analyzed to guide the optimization of corrugation structure for application. A two-scalecorrugation is suggested, which can compromise both the enhanced heat transfer effect and adequatecross section area for flows, and it makes the heat transfer coefficient 1 to 2 times more than thatof an equivalent plane one.
基金The National Basic Research Program of China(973Program) (NoG2000026303)the National Natural Science Foun-dation of China (No50176008)
文摘A novel strip-coil-baffle structure used to enhance heat transfer and support the tube bundle for a tube-shell heat exchanger is proposed. The new structure can sleeve the tubes in bundle alternatively to create a vortex flow in a heat exchanger. The numerical simulation on the flow and heat transfer characteristics for this new structure heat exchanger is conducted. The computational domain consists of two strip-coil sleeved tubes and two bare tubes oppositely placed at each comer of a square. The velocity and temperature fields in such strip-coil-baffled channel are simulated using FLUENT software. The effects of the strip-coil-baffles on heat transfer enhancement and flow resistance in relation to the Reynolds number are analyzed. The results show that this new structure bundle can enhance the heat transfer coefficient up to a range of 40% to 55% in comparison with a bare tube bundle; meanwhile, higher flow resistance is also accompanied. It is believe that the strip-coil- baffled heat exchanger should have promising applications in many industry fields.
基金Supported by the National Key Technologies Research and Development Program during the 10th Five-year Plan Period(2004BA319B1)the Educational Commission of Liaoning Province of China(2008S117)
文摘The physical models of the outer and inner half coil jackets were simplified to two types of coiled ducts.The mathematic models of incompressible fluid at the condition of laminar flow and heat transfer in the two types of jackets for cooling process reactor were set up and solved by the semi-implicit method for pressure linked equa-tions consistent (SIMPLEC) algorithm based on a control volume method.The flow and temperature fields were given and the effects of Dean and Prandtl numbers on flow and heat transfer were studied.The results show that flow in the inner half coil jacket is found to exhibit transition of secondary flow pattern from two vortices to four vortices when the Dean number increases,but that in the outer half coil jacket is not found.The critical Dean num-ber is about 96.The inner half coil jacket has stronger heat transfer ability than the outer half coil jacket and this superiority is more evident with larger Prandtl number.However,as the Dean number is greater than 105,the flow resistance enhances more severely in the inner jacket than the outer jacket.For both jackets,the centers of the heated wall are the poorest for heat transfer.
文摘This paper deals with the experimental investigation on Nusselt number,friction factor and thermal en-hancement factor of a double pipe heat exchanger equipped with twisted tape consisting wire nails(WN-TT) and plain twisted tapes(P-TT) with three different twist ratios of y 2.0,4.4 and 6.0. Test runs are conducted using the water as the working fluid with Reynolds number range between 2000 and 12000 for WN-TT and P-TT. It is found that Nusselt number,friction factor and thermal enhancement factor in the tube equipped with WN-TT appreciably higher than those in the tube fitted with P-TT and plain tube. Over the range considered Nusselt number,friction factor and thermal enhancement factor in a tube with WN-TT are respectively,1.08 to 1.31,1.1 to 1.75 and 1.05 to 1.13 times of those in tube with P-TT. The better performance of WN-TT is due to combined effects of the follow-ing factors:(1) common swirling flow generated by P-TT,(2) additional turbulence offered by the wire nails. Em-pirical correlations for Nusselt number,friction factor and thermal enhancement factor are also formulated from the experimental results of WN-TT and P-TT.
文摘The influences of circular-ring turbulators (CRT) and twisted tape (TT) swirl generators on the heat transfer enhancement, pressure drop and thermal performance factor characteristics in a round tube are reported. The circular-ring turbulators were individually employed and together with the twisted tape swirl generators in the heated section of the tube. Three different pitch ratios (I/D = 1.0, 1.5, and 2.0) of the CRT and three different twist ratios (y/W= 3, 4, and 5) of the TT were introduced. The experiments were conducted using air as the working fluid under a uniform wall heat flux condition, for the Reynolds number between 6000 and 20000. The experimental results reveal that the heat transfer rate, friction factor and thermal performance factor of the combined CRT and qT are considerably higher than those of CRT alone. For the range examined, the Sncreases of mean Nusselt number, friction factor and thermal performance, in the tube equipped with combined devices, respectively, are 25.8%, 82.8% and 6.3% over those in the tube with the CRT alone. The highest thermal performance factor of 1.42 is found for the combined device consisting of the CRT with l/D = 1.0 and TT with y/W= 3. The correlations of the Nusselt number, friction factor and thermal performance factor of the tubes with combined devices are also developed in terms of Reynolds number, Prandtl number, twist ratio and pitch ratio.
文摘Heat transfer,friction factor and thermal enhancement factor characteristics of a double pipe heat exchanger fitted with square-cut twisted tapes(STT) and plain twisted tapes(PTT) are investigated experimentally using the water as working fluid.The tapes(STT and PTT) have three twist ratios(y=2.0,4.4 and 6.0) and the Reynolds number ranges from 2000 to 12000.The experimental results reveal that heat transfer rate,friction factor and thermal enhancement factor in the tube equipped with STT are significantly higher than those fitted with PTT. The additional disturbance and secondary flow in the vicinity of the tube wall generated by STT are higher compared to that induced by the PTT is referred as the reason for better performance.Over the range considered,the Nusselt number,friction factor and thermal enhancement factor in a tube with STT are respectively,1.03 to 1.14,1.05 to 1.25 and 1.02 to 1.06 times of those in tube with PTT.An empirical correlation is also formulated to match with experimental data of Nusselt number and friction factor for STT and PTT.
文摘This paper presents the heat transfer characteristics of A1203-water nanofluid in a coiled agitated vessel with propeller agitator. The experimental study was conducted using 0.10%, 0.20% and 0.30% volume concentra tion of A1203-water nanofluids. The results showed considerable enhancement of convective heat transfer using the nanofluids. The empirical correlations developed for Nusselt number in terms of Reynolds number, Prandtl number, viscosity ratio and volume concentration fit with the experimental data within ±10%. The heat transfer characteris tics were also simulated using computational fluid dynamics using FLUENT software with the standard ke model and multiple reference frame were adopted. The computational fluid dynamics (CFD) predicted Nusselt number agrees well with the experimental value and the discrepancy is found to be less than +8%.
文摘The backward-facing step is a critical problem existing in many engineering and industrial applications.In this study,a semi-porous baffle(the root of the baffle is a porous medium and the tip is solid) is placed behind the step.The effects of the length of the porous part,and the baffle location on the energy transfer and pressure drop are studied in different Reynolds numbers(Re=100,200,300,400,500).The effect of the Darcy number of the porous medium on the aforementioned parameters is also investigated.Both the local maximum and average relative Nusselt numbers(divided by the Nusselt of the base case with no baffle at the same Reynolds) and relative pressure drop(calculated as the relative Nusselt number) are reported.The results show that by adoption of the proper length of the porous medium,the average relative and maximum local Nusselt numbers could be enhanced by 20% and 90%,respectively.Low permeable porous media give better energy transfer.For example,porous media with Da=10^(-5) give 30% better maximum local Nusselt number and about 7% higher average Nusselt number with respect to the same case with Da=10^(-2).
基金Supported by the National High Technology Research and Development Program of China(2007BAF13B01)
文摘The single-phase pressure drop and heat transfer in a rotor-assembled strand inserted tube were measured using water as the working fluid.Experiment using a smooth tube was carried out to calibrate the experimental system and the data reduction method.In the experiment,fixed mounts were used to eliminate the entrance effect. The experimental results of smooth tube show that employment of fixed mounts leads to a visible bias of friction factor at relative low Reynolds numbers,although it does not significantly affect the Nusselt numbers.The measured data of inserted tube reveal that rotor-assembled strand can significantly improve heat transfer with the Nusselt number increased by 101.6%-106.6%and the overall heat transfer coefficient increased by 58.1%-67.4%within the Reynolds number range of 20000 to 36000.Meanwhile,friction factor increases by 52.2%-84.2%within the same Reynolds number range.The correlations of Nusselt number and friction factor as function of the Reynolds number and Prandtl number were determined through multivariant linear normal regression.
基金Supported by the Science and Technology Key Projects of Shanxi Province(2011A080804012)
文摘The paper presents a 3D numerical simulation of turbulent heat transfer and flow characteristics in converging-diverging tubes (CDs) and converging-diverg)ng tubes.equi.pped with twin counter-swirling twisted tapes (CDTs). The effects of Reynolds number (Re= 10000-20000), pitch length (P= 11.25, 22.5 mm), rib height (e = 0.5, 0.8, 1.1 ram), pitch ratio (8= 1 " 8, 5 " 4, 8 " 1), gap distance between twin t)visted tapes (b = 0.5, 4.5, 8.5 mm) and tape number (n = 2, 3, 4, 5, 6) on Nusselt number (Nu), Iriction tactor 0') and thermal enhancement factor (r/) are investigated under uniform heat flux conditions,using water as working fluid. In order to illustrate the heat transter and tlu^d tlow mechamsms, flow structures m ~StJs and ~SDIs are presented. The obtained results reveal that all geometric parameters have important effects on the thermal performance of CD and CDT, and both CD and CDT show better thermal performance than plain tube at the constant pumping power. It is also found that the increases in the Nusselt number and friction factor for CDT are, respectively, up to 6.3%-35.7% and 1.75-5.3 times of thecorresponding bare CD. All CDTs have good thermal perbrmance with greater than 1 which indicates that the compound heat transfer technique of CDT is commendable for the maximum enhanced heat transfer rate.
基金supported by the National Natural Science Foundation of China(Nos.51868035,51866006,51468028)Foundation of a Hundred Youth Talents Training Program of Lanzhou Jiaotong Universitythe Science and Technology Plan of Gansu Province(No.18JR3RA121).
文摘The application of vortex generators in tube-finned heat exchangers is very universal.The vortex generators can generate secondary flow,and as we all know secondary flow can obviously strengthen heat transfer.To use vortex generators much more efficiently in the circle tube-finned heat exchangers,the intensity correlation study between secondary flow and heat transfer is needed.22 different structures of circle tube-finned heat exchangers were numerically studied,including the plain fin cases and the cases with vortex generators.In addition,the influence of fin spacing,transverse and longitudinal tube pitch,heights and attack angle of vortex generators,positions of vortex generators and shape of vortex generators on heat transfer and fluid flow are studied,too.The non-dimensional parameter Se is applied to quantify the secondary flow intensity.The results show that Se can describe the secondary flow intensity very well.There is very close corresponding relationship between overall averaged Nu and volumetrically averaged Se for all the researched cases and the relational expression is obtained.However,there is no one-to-one correlation not only between Re and f but also between volumetrically averaged Se and f for all the studied cases.
基金Supported by the Guangdong Science and Technology Project (2008A01070003)
文摘Experimental and numerical investigations have been conducted to study turbulent flow of water and heat transfer characteristics in a rectangular channel with discontinuous crossed ribs and grooves.The tests investigated the overall heat transfer performance and friction factor in ribbed and ribbed-grooved channels with rib angle of 30°.The experimental results show that the overall thermo-hydraulic performance for ribbed-grooved channel is increased by 10%-13.6% when compared to ribbed channel.The investigation on the effects of different rib angles and rib pitches on heat transfer characteristics and friction factor in ribbed-grooved channel was carried out using Fluent with SST(shear-stress transport) k-ω turbulence model.The numerical results indicate that the case for rib angle of 45° shows the best overall thermo-hydraulic performance,about 18%-36% higher than the case for rib angle of 0°.In addition,the flow patterns and local heat transfer characteristics for ribbed and ribbed-grooved channels based on the numerical simulation were also analyzed to reveal the mechanism of heat transfer enhancement.
文摘This study examines the heat transfer enhancement from a horizontal rectangular fin embedded with triangular perforations (their bases parallel and toward the fin tip) under natural convection. The fin's heat dissipation rate is compared to that of an equivalent solid one. The parameters considered are geometrical dimensions and thermal properties of the fin and the perforations. The gain in the heat transfer enhancement and the fin weight reduction due to the perforations are considered. The study shows that the heat dissipation from the perforated fin for a certain range of triangular perforation dimensions and spaces between perforations result in improvement in the heat transfer over the equivalent solid fin. The heat transfer enhancement of the perforated fin increases as the fin thermal conductivity and its thickness are increased.
文摘Heat transfer enhancement in vertical tubes plays an important role on the thermal performance of many heat exchangers and thermal devices.In this work,laminar mixed convection of airflow in a vertical dimpled tube was numerically investigated.Three-dimensional elliptical governing equations were solved using the finite-volume technique.For a given dimpled pitch,the effects of three different dimple heights(h/D=0.013,0.027,0.037) have been studied at different Richardson numbers(0.1,1.0 and 1.5).The generated vortex in the vicinity of the dimple destructs the thermal boundary layer and enhances the heat transfer.Therefore,lower wall temperature is seen where the dimples are located.Fluid flow velocity at the near-wall region significantly increases because of buoyancy forces with the increase of Richardson numbers.Such an acceleration at the near-wall region makes the dimples more effective at higher Richardson number.Using a dimpled tube enhances the heat transfer coefficient.However,the pressure drop is not important.For instance,in the case of Ri=1.5 and h/D=0.037,20% gains in the heat transfer enhancement only costs2.5% in the pressure loss.In general,it is recommended using a dimpled tube where the effects of buoyancy forces are important.