期刊文献+
共找到94,679篇文章
< 1 2 250 >
每页显示 20 50 100
Comparative Analysis of Continuous versus Intermittent Proton Pump Inhibitor Therapy in Patients with Upper Gastrointestinal Bleeding Due to Ulcers
1
作者 Abraamyan Feruza Misra P. Neeladri 《Open Journal of Gastroenterology》 CAS 2024年第3期99-107,共9页
Upper gastrointestinal bleeding (UGIB) presents as a prevalent clinical challenge, with annual incidence rates ranging from 80 to 150 cases per 100,000 individuals. Guidelines for managing patients with UGIB due to bl... Upper gastrointestinal bleeding (UGIB) presents as a prevalent clinical challenge, with annual incidence rates ranging from 80 to 150 cases per 100,000 individuals. Guidelines for managing patients with UGIB due to bleeding ulcers recommend a continuous infusion of proton pump inhibitors (PPI). However, studies comparing intermittent dosing of PPI therapy show that this regimen achieves similar clinical benefits. If the clinical efficacy remains equivalent, intermittent dosing will be more cost-effective for patients and the health care system. Our research study aims to analyze the comparative effectiveness of intermittent versus continuous PPI therapy after endoscopic treatment in patients with UGIB, focusing on such endpoints as rebleeding risk at 3-and 7-day mortality rates. Methods: Resources searched included MEDLINE, EMBASE, PUBMED, and the Cochrane Central Register of Controlled Trials databases from January 2010 through December 2023 with the inclusion of meta-analysis, systematic review, review, or ACG guideline recommendations. Results of the analysis show how recommendations regarding high vs. low PPI regimen changed over time: from no difference in regimen in 2010 to recommending continuous regimen in 2012 to declaring insufficient evidence between choosing one regimen over another in 2013 to determine that both regimens were comparable to each other in 2014-2018 and finally to recommending both regimens in 2021. To conclude, our review shows that in patients with bleeding ulcers and high-risk endoscopic findings, intermittent PPI therapy is non-inferior to continuous PPI infusion for three days, seven days bleeding risk or mortality rates;however, it remains challenging to determine the most optimal intermittent regimen due to heterogeneity of RCTs included in meta-analyses, and further trials will need to be performed. 展开更多
关键词 Upper Gastrointestinal Bleeding PPI continuous INTERMITTENT BOLUS REGIMENS Review
下载PDF
Strengthening effect of prefabrication(10-12)tensile twinning on AZ80+0.4%Ce magnesium alloy and inhibition mechanism of discontinuous precipitation
2
作者 Zhen Wang Xi Zhao +5 位作者 Zhimin Zhang Yaojin Wu Kai Chen Xianwei Ren Dengkui Wang Wei Wang 《Journal of Magnesium and Alloys》 SCIE EI CAS CSCD 2024年第5期1918-1930,共13页
This paper provided an effective method to further improve the mechanical properties of the AZ80+0.4%Ce magnesium alloy wheel spoke.The effect of high strength and ductility was obtained with a yield strength of 295.3... This paper provided an effective method to further improve the mechanical properties of the AZ80+0.4%Ce magnesium alloy wheel spoke.The effect of high strength and ductility was obtained with a yield strength of 295.36 MPa,an elongation of 10%,by the combination of pre-deformation(7%deformation)and two-stage aging treatment(120℃/9 h+175℃/24 h).The evolution of the microstructure and properties of the alloy was explored under the coupling conditions of different pre-deformation degrees and multi-stage aging.The results show that,pre-deformation introduced a large number of(1012)tensile twinning and dislocations,which greatly promoted the probability of continuous precipitates(CPs)appearing.On the contrary,the discontinuous precipitates(DPs)were limited by the vertical and horizontal twin structure.As a result,the pre-nucleation method of two-stage aging increased the proportion of CPs by 34%-38%.Owing to the DPs was effectively suppressed,the alloy's yield strength has been greatly improved.Besides,under multi-stage aging,the twin boundaries induce protruding nucleation to form static recrystallization by hindering the migration of dislocations,and the matrix swallows the twins,then the texture gradually tilts from the two poles to the basal plane.As an important supplement,the grain refinement and oblique texture promoted the improvement of the yield strength of the component. 展开更多
关键词 Magnesium alloy Pre-deformed Two-stage aging Tensile twinning continuous precipitates Texture
下载PDF
Enhanced measurement precision with continuous interrogation during dynamical decoupling
3
作者 张军 杜鹏 +3 位作者 敬雷 徐鹏 尤力 张文献 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第3期88-94,共7页
Dynamical decoupling(DD)is normally ineffective when applied to DC measurement.In its straightforward implementation,DD nulls out DC signal as well while suppressing noise.This work proposes a phase relay method that ... Dynamical decoupling(DD)is normally ineffective when applied to DC measurement.In its straightforward implementation,DD nulls out DC signal as well while suppressing noise.This work proposes a phase relay method that is capable of continuously interrogating the DC signal over many DD cycles.We illustrate its efficacy when applied to the measurement of a weak DC magnetic field with an atomic spinor Bose-Einstein condensate.Sensitivities approaching standard quantum limit or Heisenberg limit are potentially realizable for a coherent spin state or a squeezed spin state of 10000 atoms,respectively,while ambient laboratory level noise is suppressed by DD.Our work offers a practical approach to mitigate the limitations of DD to DC measurement and would find other applications for resorting coherence in quantum sensing and quantum information processing research. 展开更多
关键词 quantum sensing continuous interrogation quantum magnetometer dynamical decoupling Heisenberg limit
下载PDF
Improvement and security analysis of multi-ring discrete modulation continuous variable quantum secret sharing scheme
4
作者 姜欢窈 聂敏 +3 位作者 杨光 孙爱晶 张美玲 裴昌幸 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第7期189-197,共9页
In order to avoid the complexity of Gaussian modulation and the problem that the traditional point-to-point communication DM-CVQKD protocol cannot meet the demand for multi-user key sharing at the same time, we propos... In order to avoid the complexity of Gaussian modulation and the problem that the traditional point-to-point communication DM-CVQKD protocol cannot meet the demand for multi-user key sharing at the same time, we propose a multi-ring discrete modulation continuous variable quantum key sharing scheme(MR-DM-CVQSS). In this paper, we primarily compare single-ring and multi-ring M-symbol amplitude and phase-shift keying modulations. We analyze their asymptotic key rates against collective attacks and consider the security key rates under finite-size effects. Leveraging the characteristics of discrete modulation, we improve the quantum secret sharing scheme. Non-dealer participants only require simple phase shifters to complete quantum secret sharing. We also provide the general design of the MR-DM-CVQSS protocol.We conduct a comprehensive analysis of the improved protocol's performance, confirming that the enhancement through multi-ring M-PSK allows for longer-distance quantum key distribution. Additionally, it reduces the deployment complexity of the system, thereby increasing the practical value. 展开更多
关键词 discrete modulation continuous variable quantum secret sharing scheme
下载PDF
Irregular initial solidification by mold thermal monitoring in the continuous casting of steels:A review
5
作者 Qiuping Li Guanghua Wen +3 位作者 Fuhang Chen Ping Tang Zibing Hou Xinyun Mo 《International Journal of Minerals,Metallurgy and Materials》 SCIE EI CAS CSCD 2024年第5期1003-1015,共13页
Occasional irregular initial solidification phenomena,including stickers,deep oscillation marks,depressions,and surface cracks of strand shells in continuous casting molds,are important limitations for developing the ... Occasional irregular initial solidification phenomena,including stickers,deep oscillation marks,depressions,and surface cracks of strand shells in continuous casting molds,are important limitations for developing the high-efficiency continuous casting of steels.The application of mold thermal monitoring(MTM) systems,which use thermocouples to detect and respond to temperature variations in molds,has become an effective method to address irregular initial solidification phenomena.Such systems are widely applied in numerous steel companies for sticker breakout prediction.However,monitoring the surface defects of strands remains immature.Hence,indepth research is necessary to utilize the potential advantages and comprehensive monitoring of MTM systems.This paper summarizes what is included in the irregular initial solidification phenomena and systematically reviews the current state of research on these phenomena by the MTM systems.Furthermore,the influences of mold slag behavior on monitoring these phenomena are analyzed.Finally,the remaining problems of the formation mechanisms and investigations of irregular initial solidification phenomena are discussed,and future research directions are proposed. 展开更多
关键词 irregular initial solidification mold thermal monitoring continuous casting mold slag THERMOCOUPLE
下载PDF
Effect of continuous nursing on rehabilitation of older patients with joint replacement after discharge
6
作者 Xiao-Yan Qi Hong-Yan Zhou Yu-Hong Xing 《World Journal of Clinical Cases》 SCIE 2024年第21期4558-4565,共8页
BACKGROUND Joint replacement is a common treatment for older patients with high incidences of hip joint diseases.However,postoperative recovery is slow and complications are common,which reduces surgical effectiveness... BACKGROUND Joint replacement is a common treatment for older patients with high incidences of hip joint diseases.However,postoperative recovery is slow and complications are common,which reduces surgical effectiveness.Therefore,patients require long-term,high-quality,and effective nursing interventions to promote rehabilitation.Continuity of care has been used successfully in other diseases;however,little research has been conducted on older patients who have undergone hip replacement.AIM To explore the clinical effect of continuous nursing on rehabilitation after discharge of older individuals who have undergone joint replacement.METHODS A retrospective analysis was performed on the clinical data of 113 elderly patients.Patients receiving routine nursing were included in the convention group(n=60),and those receiving continuous nursing,according to various methods,were included in the continuation group(n=53).Harris score,short form 36(SF-36)score,complication rate,and readmission rate were compared between the convention and continuation groups.RESULTS After discharge,Harris and SF-36 scores of the continuation group were higher than those of the convention group.The Harris and SF-36 scores of the two groups showed an increasing trend with time,and there was an interaction effect between group and time(Harris score:F_(intergroup effect)=376.500,F_(time effect)=20.090,Finteraction effect=4.824;SF-36 score:F_(intergroup effect)=236.200,Ftime effect=16.710,Finteraction effect=5.584;all P<0.05).Furthermore,the total complication and readmission rates in the continuation group were lower(P<0.05).CONCLUSION Continuous nursing could significantly improve hip function and quality of life in older patients after joint replacement and reduce the incidence of complications and readmission rates. 展开更多
关键词 continuous nursing DISCHARGE Older adults Joint replacement REHABILITATION EFFECT
下载PDF
THE ABSENCE OF SINGULAR CONTINUOUS SPECTRUM FOR PERTURBED JACOBI OPERATORS
7
作者 傅钲淇 黎雄 《Acta Mathematica Scientia》 SCIE CSCD 2024年第2期515-531,共17页
This paper is mainly about the spectral properties of a class of Jacobi operators(H_(c,b)u)(n)=c_(n)u(n+1)+c_(n-1)u(n-1)+b_(n)u(n),.where∣c_(n)−1∣=O(n^(−α))and b_(n)=O(n^(−1)).We will show that,forα≥1,the singula... This paper is mainly about the spectral properties of a class of Jacobi operators(H_(c,b)u)(n)=c_(n)u(n+1)+c_(n-1)u(n-1)+b_(n)u(n),.where∣c_(n)−1∣=O(n^(−α))and b_(n)=O(n^(−1)).We will show that,forα≥1,the singular continuous spectrum of the operator is empty. 展开更多
关键词 Jacobi operator singular continuous spectrum Prüfer variables
下载PDF
Existence of a Hölder Continuous Extension on Embedded Balls of the 3-Torus for the Periodic Navier Stokes Equations
8
作者 Terry E. Moschandreou 《Advances in Pure Mathematics》 2024年第2期118-138,共21页
This article gives a general model using specific periodic special functions, which is degenerate elliptic Weierstrass P functions whose presence in the governing equations through the forcing terms simplify the perio... This article gives a general model using specific periodic special functions, which is degenerate elliptic Weierstrass P functions whose presence in the governing equations through the forcing terms simplify the periodic Navier Stokes equations (PNS) at the centers of cells of the 3-Torus. Satisfying a divergence-free vector field and periodic boundary conditions respectively with a general spatio-temporal forcing term which is smooth and spatially periodic, the existence of solutions which have finite time singularities can occur starting with the first derivative and higher with respect to time. The existence of a subspace of the solution space where v<sub>3</sub> is continuous and {C, y<sub>1</sub>, y<sub>1</sub><sup>2</sup>}, is linearly independent in the additive argument of the solution in terms of the Lambert W function, (y<sub>1</sub><sup>2</sup>=y<sub>2</sub>, C∈R) together with the condition v<sub>2</sub>=-2y<sub>1</sub>v<sub>1</sub>. On this subspace, the Biot Savart Law holds exactly [see Section 2 (Equation (13))]. Also on this subspace, an expression X (part of PNS equations) vanishes which contains all the expressions in derivatives of v<sub>1</sub> and v<sub>2</sub> and the forcing terms in the plane which are related as with the cancellation of all such terms in governing PDE. The y<sub>3</sub> component forcing term is arbitrarily small in ε ball where Weierstrass P functions touch the center of the ball both for inviscid and viscous cases. As a result, a significant simplification occurs with a v<sub>3 </sub>only governing PDE resulting. With viscosity present as v changes from zero to the fully viscous case at v =1 the solution for v<sub>3</sub> reaches a peak in the third component y<sub>3</sub>. Consequently, there exists a dipole which is not centered at the center of the cell of the Lattice. Hence since the dipole by definition has an equal in magnitude positive and negative peak in y<sub>3</sub>, then the dipole Riemann cut-off surface is covered by a closed surface which is the sphere and where a given cell of dimensions [-1, 1]<sup>3</sup> is circumscribed on a sphere of radius 1. For such a closed surface containing a dipole it necessarily follows that the flux at the surface of the sphere of v<sub>3</sub> wrt to surface normal n is zero including at the points where the surface of sphere touches the cube walls. At the finite time singularity on the sphere a rotation boundary condition is deduced. It is shown that v<sub>3</sub> is spatially finite on the Riemann Sphere and the forcing is oscillatory in y<sub>3</sub> component if the velocity v3</sub> is. It is true that . A boundary condition on the sphere shows the rotation of a sphere of viscous fluid. Finally on the sphere a solution for v3</sub> is obtained which is proven to be Hölder continuous and it is shown that it is possible to extend Hölder continuity on the sphere uniquely to all of the interior of the ball. 展开更多
关键词 Navier-Stokes PNS 3-Torus PERIODIC Ball Sphere Hölder continuous Riemann-Surface Uniqueness
下载PDF
Large-scale particle trapping by acoustic vortices with a continuously variable topological charge
9
作者 庄昊霏 张清源 +2 位作者 胡格昊 王青东 杜立彬 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第7期398-406,共9页
Strengthened directivity with higher-order side lobes can be generated by the transducer with a larger radius at a higher frequency. The multi-annular pressure distributions are displayed in the cross-section of the a... Strengthened directivity with higher-order side lobes can be generated by the transducer with a larger radius at a higher frequency. The multi-annular pressure distributions are displayed in the cross-section of the acoustic vortices(AVs)which are formed by side lobes. In the near field, particles can be trapped in the valley region between the two annuli of the pressure peak, and cannot be moved to the vortex center. In this paper, a trapping method based on a sector transducer array is proposed, which is characterized by the continuously variable topological charge(CVTC). This acoustic field can not only enlarge the range of particle trapping but also improve the aggregation degree of the trapped particles. In the experiments, polyethylene particles with a diameter of 0.2 mm are trapped into the multi-annular valleys by the AV with a fixed topological charge. Nevertheless, by applying the CVTC, particles outside the radius of the AV can cross the pressure peak successfully and move to the vortex center. Theoretical studies are also verified by the experimental particles trapping using the AV with the continuous variation of three topological charges, and suggest the potential application of large-scale particle trapping in biomedical engineering. 展开更多
关键词 acoustic vortices sector transducer array trapping particle continuously variable topological charge
下载PDF
Application and Evaluation of Continuous Care Model Based on the Omaha System in Stroke Patients after Discharge
10
作者 Jia LI Yumei GUO Xiaochun LI 《Medicinal Plant》 2024年第1期79-81,84,共4页
[Objectives]To explore the effect of continuous nursing model based on the Omaha system on stroke patients.[Methods]A total of 40 stroke patients in the inpatient department of the Rehabilitation Department of Affilia... [Objectives]To explore the effect of continuous nursing model based on the Omaha system on stroke patients.[Methods]A total of 40 stroke patients in the inpatient department of the Rehabilitation Department of Affiliated Hospital of Jinggangshan University were selected and divided into two groups by the random number table method.Patients in the control group were given routine nursing,and those of the observation group were given continuous nursing based on the Omaha system theory.The score of neurological impairment,daily living ability scale and the quality of life,as well as patients satisfaction rate before and after treatment were compared between the two groups.[Results]The score of neurological impairment,daily living activity ability and the quality of life,as well as patients nursing satisfaction rate in the observation group were significantly better than those of the control group,with statistical significance(P<0.05).[Conclusions]The continuous nursing model based on the Omaha system can significantly improve the neurological function of stroke patients,improve their quality of life and life ability,and promote their rehabilitation. 展开更多
关键词 Omaha system continuous nursing STROKE
下载PDF
Microarrow sensor array with enhanced skin adhesion for transdermal continuous monitoring of glucose and reactive oxygen species
11
作者 Xinshuo Huang Baoming Liang +9 位作者 Shantao Zheng Feifei Wu Mengyi He Shuang Huang Jingbo Yang Qiangqiang Ouyang Fanmao Liu Jing Liu Hui-jiuan Chen Xi Xie 《Bio-Design and Manufacturing》 SCIE EI CAS CSCD 2024年第1期14-30,共17页
Conventional blood sampling for glucose detection is prone to cause pain and fails to continuously record glucose fluctuations in vivo.Continuous glucose monitoring based on implantable electrodes could induce pain an... Conventional blood sampling for glucose detection is prone to cause pain and fails to continuously record glucose fluctuations in vivo.Continuous glucose monitoring based on implantable electrodes could induce pain and potential tissue inflammation,and the presence of reactive oxygen species(ROS)due to inflammationmay affect glucose detection.Microneedle technology is less invasive,yet microneedle adhesion with skin tissue is limited.In this work,we developed a microarrow sensor array(MASA),which provided enhanced skin surface adhesion and enabled simultaneous detection of glucose and H_(2)O_(2)(representative of ROS)in interstitial fluid in vivo.The microarrows fabricated via laser micromachining were modified with functional coating and integrated into a patch of a three-dimensional(3D)microneedle array.Due to the arrow tip mechanically interlocking with the tissue,the microarrow array could better adhere to the skin surface after penetration into skin.The MASA was demonstrated to provide continuous in vivo monitoring of glucose and H_(2)O_(2) concentrations,with the detection of H_(2)O_(2) providing a valuable reference for assessing the inflammation state.Finally,the MASA was integrated into a monitoring system using custom circuitry.This work provides a promising tool for the stable and reliable monitoring of blood glucose in diabetic patients. 展开更多
关键词 Microarrow sensor array Glucose sensing Reactive oxygen species sensing Integrated system continuous monitoring
下载PDF
Pain Efficacy of a Home-Based Low-Intensity Continuous Ultrasound Stimulator for Knee Arthritis: A Single-Arm, Open-Label, Prospective Clinical Trial
12
作者 Md. Habibur Rahman Yeon-Gyu Jang +8 位作者 Johny Bajgai Subham Sharma Kchorng Vira Abdul-Nasir Sofian Seong Hoon Goh Yundeok Kim Cheol-Su Kim Doo-Sup Kim Kyu-Jae Lee 《Health》 2024年第7期703-716,共14页
1) Background: Osteoarthritis (OA) is defined as a degenerative joint disease that mainly affects the bone. This study aims to evaluate the effect of low-intensity continuous ultrasound (LICUS) treatment on the knee o... 1) Background: Osteoarthritis (OA) is defined as a degenerative joint disease that mainly affects the bone. This study aims to evaluate the effect of low-intensity continuous ultrasound (LICUS) treatment on the knee of osteoarthritis patients through home-based intervention using the LICUS medical device. 2) Methods: The clinical trials were designed in a single-arm, open-label, and intervention study. Thirty-five participants, including those who dropped out (12%), were screened and enrolled. The patients received LICUS (1.1 MHz, 1.5 W/cm2, collimated beams) on the knee by the instructions of the investigator at home (5 min/session, 3 times/day, for four-weeks). Outcome measures were assessed using the Visual Analog Scale (VAS) as a primary endpoint and the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) as a secondary endpoint to evaluate pain relief and functional recovery of the knee between pre-treatment (baseline) and post-treatment (four-weeks). 3) Results: Knee pain scores measured using the VAS and WOMAC indices were significantly reduced after a four-week treatment with LICUS compared to baseline. Knee stiffness and functional capacity were significantly reduced after the LICUS application. In addition, there were no reports of adverse effects during the study period. 4) Conclusion: Long-term and home-based application of LICUS can be recommended as an alternative option for the treatment of OA patients, as evidenced by the effect of pain relief and knee function recovery. 展开更多
关键词 Knee Osteoarthritis Low-Intensity continuous Ultrasound Stimulator Clinical Trial Visual Analogue Scale Western Ontario and McMaster Universities Osteoarthritis Index
下载PDF
Impact of continuous care on cardiac function in patients with lung cancer complicated by coronary heart disease
13
作者 Ting Gao Jin-Lan Luo +3 位作者 Pan Guo Xi-Wen Hu Xiao-Yan Wei Yan Hu 《World Journal of Clinical Cases》 SCIE 2024年第2期314-321,共8页
BACKGROUND Despite sharing similar pathogenic factors,cancer and coronary heart disease(CHD)occur in comparable populations at similar ages and possess similar susceptibility factors.Consequently,it is increasingly co... BACKGROUND Despite sharing similar pathogenic factors,cancer and coronary heart disease(CHD)occur in comparable populations at similar ages and possess similar susceptibility factors.Consequently,it is increasingly commonplace for patients to experience the simultaneous occurrence of cancer and CHD,a trend that is steadily rising.AIM To determine the impacts of continuing care on lung cancer patients with CHD following percutaneous coronary intervention(PCI).METHODS There were 94 lung cancer patients with CHD following PCI who were randomly assigned to the intervention group(n=38)and the control group(n=41).In the intervention group,continuing care was provided,while in the control group,routine care was provided.An evaluation of cardiac and pulmonary function,medication compliance,a 6-min walk test,and patient quality of life was performed.RESULTS Differences between the two groups were significant in left ventricular ejection fraction,6-min walk test,oxygen uptake,quality of life and medication compliance(P<0.05).In comparison with the control group,the enhancement in the intervention group was more significant.The intervention group had more patients with high medication compliance than the control group,with a statistically significant difference(P<0.05).CONCLUSION After undergoing PCI,lung patients with CHD could benefit from continued care in terms of cardiac and pulmonary function,medications compliance,and quality of life. 展开更多
关键词 Lung cancer continuing care Coronary heart disease Percutaneous coronary intervention
下载PDF
Regulatable Orthotropic 3D Hybrid Continuous Carbon Networks for Efficient Bi-Directional Thermal Conduction
14
作者 Huitao Yu Lianqiang Peng +2 位作者 Can Chen Mengmeng Qin Wei Feng 《Nano-Micro Letters》 SCIE EI CAS CSCD 2024年第10期136-148,共13页
Vertically oriented carbon structures constructed from low-dimen-sional carbon materials are ideal frameworks for high-performance thermal inter-face materials(TIMs).However,improving the interfacial heat-transfer eff... Vertically oriented carbon structures constructed from low-dimen-sional carbon materials are ideal frameworks for high-performance thermal inter-face materials(TIMs).However,improving the interfacial heat-transfer efficiency of vertically oriented carbon structures is a challenging task.Herein,an orthotropic three-dimensional(3D)hybrid carbon network(VSCG)is fabricated by depositing vertically aligned carbon nanotubes(VACNTs)on the surface of a horizontally oriented graphene film(HOGF).The interfacial interaction between the VACNTs and HOGF is then optimized through an annealing strategy.After regulating the orientation structure of the VACNTs and filling the VSCG with polydimethylsi-loxane(PDMS),VSCG/PDMS composites with excellent 3D thermal conductive properties are obtained.The highest in-plane and through-plane thermal conduc-tivities of the composites are 113.61 and 24.37 W m^(-1)K^(-1),respectively.The high contact area of HOGF and good compressibility of VACNTs imbue the VSCG/PDMS composite with low thermal resistance.In addition,the interfacial heat-transfer efficiency of VSCG/PDMS composite in the TIM performance was improved by 71.3%compared to that of a state-of-the-art thermal pad.This new structural design can potentially realize high-performance TIMs that meet the need for high thermal conductivity and low contact thermal resistance in interfacial heat-transfer processes. 展开更多
关键词 Orthotropic continuous structures Hybrid carbon networks Carbon/polymer composites Thermal interface materials
下载PDF
Continuous glucose monitoring metrics in pregnancy with type 1 diabetes mellitus
15
作者 Mohammad Sadiq Jeeyavudeen Mairi Crosby Joseph M Pappachan 《World Journal of Methodology》 2024年第1期6-17,共12页
Managing diabetes during pregnancy is challenging,given the significant risk it poses for both maternal and foetal health outcomes.While traditional methods involve capillary self-monitoring of blood glucose level mon... Managing diabetes during pregnancy is challenging,given the significant risk it poses for both maternal and foetal health outcomes.While traditional methods involve capillary self-monitoring of blood glucose level monitoring and periodic HbA1c tests,the advent of continuous glucose monitoring(CGM)systems has revolutionized the approach.These devices offer a safe and reliable means of tracking glucose levels in real-time,benefiting both women with diabetes during pregnancy and the healthcare providers.Moreover,CGM systems have shown a low rate of side effects and high feasibility when used in pregnancies complicated by diabetes,especially when paired with continuous subcutaneous insulin infusion pump as hybrid closed loop device.Such a combined approach has been demonstrated to improve overall blood sugar control,lessen the occurrence of preeclampsia and neonatal hypoglycaemia,and minimize the duration of neonatal intensive care unit stays.This paper aims to offer a comprehensive evaluation of CGM metrics specifically tailored for pregnancies impacted by type 1 diabetes mellitus. 展开更多
关键词 Type 1 diabetes mellitus continuous glucose monitoring PREGNANCY Glycaemic control continuous glucose monitoring system
下载PDF
A low-frequency pure metal metamaterial absorber with continuously tunable stiffness
16
作者 Xingzhong WANG Shiteng RUI +2 位作者 Shaokun YANG Weiquan ZHANG Fuyin MA 《Applied Mathematics and Mechanics(English Edition)》 SCIE EI CSCD 2024年第7期1209-1224,共16页
To address the incompatibility between high environmental adaptability and deep subwavelength characteristics in conventional local resonance metamaterials,and overcome the deficiencies in the stability of existing ac... To address the incompatibility between high environmental adaptability and deep subwavelength characteristics in conventional local resonance metamaterials,and overcome the deficiencies in the stability of existing active control techniques for band gaps,this paper proposes a design method of pure metal vibration damping metamaterial with continuously tunable stiffness for wideband elastic wave absorption.We design a dual-helix narrow-slit pure metal metamaterial unit,which possesses the triple advantage of high spatial compactness,low stiffness characteristics,and high structural stability,enabling the opening of elastic flexural band gaps in the low-frequency range.Similar to the principle of a sliding rheostat,the introduction of continuously sliding plug-ins into the helical slits enables the continuous variation of the stiffness of the metamaterial unit,achieving a continuously tunable band gap effect.This successfully extends the effective band gap by more than ten times.The experimental results indicate that this metamaterial unit can be used as an additional vibration absorber to absorb the low-frequency vibration energy effectively.Furthermore,it advances the metamaterial absorbers from a purely passive narrowband design to a wideband tunable one.The pure metal double-helix metamaterials retain the subwavelength properties of metamaterials and are suitable for deployment in harsh environments.Simultaneously,by adjusting its stiffness,it substantially broadens the effective band gap range,presenting promising potential applications in various mechanical equipment operating under adverse conditions. 展开更多
关键词 elastic metamaterial absorber continuously tunable stiffness low-frequency vibration damping variable stiffness design pure metal structure
下载PDF
Multi-scale context-aware network for continuous sign language recognition
17
作者 Senhua XUE Liqing GAO +1 位作者 Liang WAN Wei FENG 《虚拟现实与智能硬件(中英文)》 EI 2024年第4期323-337,共15页
The hands and face are the most important parts for expressing sign language morphemes in sign language videos.However,we find that existing Continuous Sign Language Recognition(CSLR)methods lack the mining of hand an... The hands and face are the most important parts for expressing sign language morphemes in sign language videos.However,we find that existing Continuous Sign Language Recognition(CSLR)methods lack the mining of hand and face information in visual backbones or use expensive and time-consuming external extractors to explore this information.In addition,the signs have different lengths,whereas previous CSLR methods typically use a fixed-length window to segment the video to capture sequential features and then perform global temporal modeling,which disturbs the perception of complete signs.In this study,we propose a Multi-Scale Context-Aware network(MSCA-Net)to solve the aforementioned problems.Our MSCA-Net contains two main modules:(1)Multi-Scale Motion Attention(MSMA),which uses the differences among frames to perceive information of the hands and face in multiple spatial scales,replacing the heavy feature extractors;and(2)Multi-Scale Temporal Modeling(MSTM),which explores crucial temporal information in the sign language video from different temporal scales.We conduct extensive experiments using three widely used sign language datasets,i.e.,RWTH-PHOENIX-Weather-2014,RWTH-PHOENIX-Weather-2014T,and CSL-Daily.The proposed MSCA-Net achieve state-of-the-art performance,demonstrating the effectiveness of our approach. 展开更多
关键词 continuous sign language recognition Multi-scale motion attention Multi-scale temporal modeling
下载PDF
Personalized and continuous care intervention affects rehabilitation,living quality,and negative emotions of patients with breast cancer
18
作者 Ling-Xia Kong Yan-Hong Zhao +1 位作者 Zhi-Lin Feng Ting-Ting Liu 《World Journal of Psychiatry》 SCIE 2024年第6期876-883,共8页
BACKGROUND Breast cancer is among the most common malignancies worldwide.With progress in treatment methods and levels,the overall survival period has been prolonged,and the demand for quality care has increased.AIM T... BACKGROUND Breast cancer is among the most common malignancies worldwide.With progress in treatment methods and levels,the overall survival period has been prolonged,and the demand for quality care has increased.AIM To investigate the effect of individualized and continuous care intervention in patients with breast cancer.METHODS Two hundred patients with breast cancer who received systemic therapy at The First Affiliated Hospital of Hebei North University(January 2021 to July 2023)were retrospectively selected as research participants.Among them,134 received routine care intervention(routing group)and 66 received personalized and continuous care(intervention group).Self-rating anxiety scale(SAS),self-rating depression scale(SDS),and Functional Assessment of Cancer Therapy-Breast(FACT-B)scores,including limb shoulder joint activity,complication rate,and care satisfaction,were compared between both groups after care.RESULTS SAS and SDS scores were lower in the intervention group than in the routing group at one and three months after care.The total FACT-B scores and five dimensions in the intervention group were higher than those in the routing group at three months of care.The range of motion of shoulder anteflexion,posterior extension,abduction,internal rotation,and external rotation in the intervention group was higher than that in the routing group one month after care.The incidence of postoperative complications was 18.18%lower in the intervention group than in the routing group(34.33%;P<0.05).Satisfaction with care was 90.91% higher in the intervention group than in the routing group(78.36%;P<0.05).CONCLUSION Personalized and continuous care can alleviate negative emotions in patients with breast cancer,quicken rehabilitation of limb function,decrease the incidence of complications,and improve living quality and care satisfaction. 展开更多
关键词 Breast cancer Personalized care continuous care Negative emotions Living quality Rehabilitation effect
下载PDF
Auto-parametric resonance of a continuous-beam-bridge model under two-point periodic excitation:an experimental investigation and stability analysis
19
作者 Li Yuchun Shen Chao +1 位作者 Liu Wei Li Dong 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2024年第2期445-454,共10页
The auto-parametric resonance of a continuous-beam bridge model subjected to a two-point periodic excitation is experimentally and numerically investigated in this study.An auto-parametric resonance experiment of the ... The auto-parametric resonance of a continuous-beam bridge model subjected to a two-point periodic excitation is experimentally and numerically investigated in this study.An auto-parametric resonance experiment of the test model is conducted to observe and measure the auto-parametric resonance of a continuous beam under a two-point excitation on columns.The parametric vibration equation is established for the test model using the finite-element method.The auto-parametric resonance stability of the structure is analyzed by using Newmark's method and the energy-growth exponent method.The effects of the phase difference of the two-point excitation on the stability boundaries of auto-parametric resonance are studied for the test model.Compared with the experiment,the numerical instability predictions of auto-parametric resonance are consistent with the test phenomena,and the numerical stability boundaries of auto-parametric resonance agree with the experimental ones.For a continuous beam bridge,when the ratio of multipoint excitation frequency(applied to the columns)to natural frequency of the continuous girder is approximately equal to 2,the continuous beam may undergo a strong auto-parametric resonance.Combined with the present experiment and analysis,a hypothesis of Volgograd Bridge's serpentine vibration is discussed. 展开更多
关键词 auto-parametric resonance continuous beam bridge model two-point excitation experimental investigation stability analysis vibration of Volgograd Bridge
下载PDF
Application and management of continuous glucose monitoring in diabetic kidney disease
20
作者 Xin-Miao Zhang Quan-Quan Shen 《World Journal of Diabetes》 SCIE 2024年第4期591-597,共7页
Diabetic kidney disease(DKD)is a common complication of diabetes mellitus that contributes to the risk of end-stage kidney disease(ESKD).Wide glycemic var-iations,such as hypoglycemia and hyperglycemia,are broadly fou... Diabetic kidney disease(DKD)is a common complication of diabetes mellitus that contributes to the risk of end-stage kidney disease(ESKD).Wide glycemic var-iations,such as hypoglycemia and hyperglycemia,are broadly found in diabetic patients with DKD and especially ESKD,as a result of impaired renal metabolism.It is essential to monitor glycemia for effective management of DKD.Hemoglobin A1c(HbA1c)has long been considered as the gold standard for monitoring glycemia for>3 months.However,assessment of HbA1c has some bias as it is susceptible to factors such as anemia and liver or kidney dysfunction.Continuous glucose monitoring(CGM)has provided new insights on glycemic assessment and management.CGM directly measures glucose level in interstitial fluid,reports real-time or retrospective glucose concentration,and provides multiple glycemic metrics.It avoids the pitfalls of HbA1c in some contexts,and may serve as a precise alternative to estimation of mean glucose and glycemic variability.Emerging studies have demonstrated the merits of CGM for precise monitoring,which allows fine-tuning of glycemic management in diabetic patients.Therefore,CGM technology has the potential for better glycemic monitoring in DKD patients.More research is needed to explore its application and management in different stages of DKD,including hemodialysis,peritoneal dialysis and kidney transplantation. 展开更多
关键词 Diabetic kidney disease continuous glucose monitoring Glycemic monitoring HEMODIALYSIS Peritoneal dialysis Kidney transplantation
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部