期刊文献+
共找到1,802篇文章
< 1 2 91 >
每页显示 20 50 100
Numerical simulation on boiling heat transfer of evaporation cooling in a billet reheating furnace
1
作者 冯明杰 王恩刚 +2 位作者 王海 李艳东 刘兵 《Journal of Central South University》 SCIE EI CAS CSCD 2016年第6期1515-1524,共10页
The boiling heat transfer of evaporation cooling in a billet reheating furnace was simulated.The results indicate that the bubbles easily aggregate inside of the elbow and upper side of the horizontal regions in theπ... The boiling heat transfer of evaporation cooling in a billet reheating furnace was simulated.The results indicate that the bubbles easily aggregate inside of the elbow and upper side of the horizontal regions in theπshaped support tubes.The circulation velocity increasing helps to improve the uniformity of vapor distribution and decrease the difference of vapor volume fraction between upper and down at end of the horizontal sections.With the increase of circulation velocity,the resistance loss and the circulation ratio both increase,but the former will decrease with the increase of work pressure. 展开更多
关键词 FURNACE evaporation cooling subcooled flow boiling support tube two-fluid model
下载PDF
Experimental Study of Air Conditioning Unit of Evaporative Cooling Assisted Mechanical Refrigeration 被引量:3
2
作者 HUANG Xiang,XU Fang-cheng,WU Jun-mei(Xi’an polytechnic University,Xi’an,Shaanxi 710048,China) 《湖南大学学报(自然科学版)》 EI CAS CSCD 北大核心 2009年第S1期106-110,共5页
The evaporative cooling,which assists the refrigeration machinery air-conditioning systems test-rig,has been designed.Its structure and working principle were described,and the performance test was conducted and analy... The evaporative cooling,which assists the refrigeration machinery air-conditioning systems test-rig,has been designed.Its structure and working principle were described,and the performance test was conducted and analyzed.The test shows that making full use of the evaporative cooling "free cooling" in Spring and Autumn seasons can fully meet the requirements of air-conditioned comfort through the switch of the function in different seasons.Taking into account the evaporative cooling fan and pump energy consumption,compared with the traditional mechanical refrigeration system,more than 80 percent of energy can be saved,and the energy efficiency ratio of the Unit(EER)is as high as 7.63.Using the two stages of indirect evaporative cooling to pre-cool the new wind in summer,under the conditions of the same air supply temperature requirements,0.83 kg/s chilled water saved can be equivalent to the traditional mechanical refrigeration system,and when the new wind ratio up to 50 percent,more than 10 percent load was reduced in mechanical refrigeration system.The overall EER increased about 35 percent. 展开更多
关键词 evaporATIVE cooling mechanical REFRIGERATION air-conditionING unit EER
下载PDF
Stark-potential evaporative cooling of polar molecules in a novel optical-access opened electrostatic trap 被引量:1
3
作者 孙慧 王振霞 +3 位作者 王琴 李兴佳 刘建平 印建平 《Chinese Physics B》 SCIE EI CAS CSCD 2015年第11期196-205,共10页
We propose a novel optical-access opened electrostatic trap to study the Stark-potential evaporative cooling of polar molecules by using two charged disk electrodes with a central hole of radius r0 = 1.5 mm, and deriv... We propose a novel optical-access opened electrostatic trap to study the Stark-potential evaporative cooling of polar molecules by using two charged disk electrodes with a central hole of radius r0 = 1.5 mm, and derive a set of new analytical equations to calculate the spatial distributions of the electrostatic field in the above charged-disk layout. Afterwards, we calculate the electric-field distributions of our electrostatic trap and the Stark potential for cold ND3 molecules, and analyze the dependences of both the electric field and the Stark potential on the geometric parameters of our charged-disk scheme, and find an optimal condition to form a desirable trap with the same trap depth in the x, y, and z directions. Also, we propose a desirable scheme to realize an efficient loading of cold polar molecules in the weak-field-seeking states, and investigate the dependences of the loading efficiency on both the initial forward velocity of the incident molecular beam and the loading time by Monte Carlo simulations. Our study shows that the maximal loading efficiency of our trap scheme can reach about 95%, and the corresponding temperature of the trapped cold molecules is about 28.8 inK. Finally, we study the Stark-potential evaporative cooling for cold polar molecules in our trap by the Monte Carlo method, and find that our simulated evaporative cooling results are consistent with our developed analytical model based on trapping-potential evaporative cooling. 展开更多
关键词 evaporative cooling electrostatic trap Monte Carlo simulations
下载PDF
Enhanced Evaporation of Ternary Mixtures in Porous Medium with Microcolumn Configuration
4
作者 Bo Zhang Yunxie Huang +4 位作者 Peilin Cui Zhiguo Wang Duo Ding Zhenhai Pan Zhenyu Liu 《Frontiers in Heat and Mass Transfer》 EI 2024年第4期997-1016,共20页
The high surface area of porous media enhances its efficacy for evaporative cooling,however,the evaporation of pure substances often encounters issues including local overheating and unstable heat transfer.To address ... The high surface area of porous media enhances its efficacy for evaporative cooling,however,the evaporation of pure substances often encounters issues including local overheating and unstable heat transfer.To address these challenges,a volume of fluid(VOF)model integrated with a species transport model was developed to predict the evaporation processes of ternary mixtures(water,glycerol,and 1,2-propylene glycol)in porous ceramics in this study.It reveals that the synergistic effects of thermal conduction and convective heat transfer significantly influence the mixtures evaporation,causing the fluctuations in evaporation rates.The obtained result shows a significant increase in water evaporation rates with decreasing the microcolumn size.At a pore size of 30μm and a porosity of 30%,an optimal balance between capillary forces and flow resistance yields a peak water release rate of 96.0%.Furthermore,decreasing the glycerol content from 70%to 60%enhances water release by 10.6%.The findings in this work propose the approaches to optimize evaporative cooling technologies by controlling the evaporation of mixtures in porous media. 展开更多
关键词 Ternary mixtures porous medium evaporation numerical simulation evaporative cooling
下载PDF
Evaporative Cooling Applied in Thermal Power Plants:A Review of the State-ofthe-Art and Typical Case Studies 被引量:1
5
作者 Tiantian Liu Huimin Pang +7 位作者 Suoying He Bin Zhao Zhiyu Zhang Jucheng Wang Zhilan Liu Xiang Huang Yuetao Shi Ming Gao 《Fluid Dynamics & Materials Processing》 EI 2023年第9期2229-2265,共37页
A review is conducted about the application of the evaporative cooling technology in thermal power plants.Different case studies are considered,namely,evaporative air conditioners,evaporative cooling in direct air-coo... A review is conducted about the application of the evaporative cooling technology in thermal power plants.Different case studies are considered,namely,evaporative air conditioners,evaporative cooling in direct air-cooled systems,gas turbine inlet cooling,wet cooling towers,and hybrid cooling towers with a crosswind effect.Some effort is provided to describe the advantages related to direct evaporative cooling when it is applied in thermal power plants and illustrate the research gaps,which have not been filled yet.In particular,typical case studies are intentionally used to compare the cooling performances when direct evaporative cooling is implemented in different types of cooling towers,including the natural draft wet cooling tower(NDWCT)and the pre-cooled natural draft dry cooling tower(NDDCT).It is shown that the NDWCT provides the best cooling performance in terms of power station cooling,followed by the pre-cooled NDDCT,and the NDDCT;moreover,the evaporative pre-cooling is able to enhance the cooling performance of NDDCT.Besides,on a yearly basis,better NDDCT cooling performances can be obtained by means of a spray-based pre-cooling approach with respect to wet media pre-cooling.Therefore,the use of nozzle spray is suggested for improvement in the performance of indirect/direct air-cooling systems with controlled water consumption. 展开更多
关键词 Direct evaporative cooling cooling tower cooling performance wet media nozzle spray thermal power plants
下载PDF
A Mathematical Model of an Evaporative Cooling Pad Using Sintered Nigerian Clay 被引量:1
6
作者 Chukwuneke Jeremiah Lekwuwa Ajike Chinagorom Ogbu +1 位作者 Achebe Chinonso Hubert Okolie Paul Chukwulozie 《Journal of Minerals and Materials Characterization and Engineering》 2012年第11期1113-1120,共8页
Overtime, reduction in the amount of heat generated in engineering systems in operations have been of great concern and have continuously been under study. It is in line with the above that this research work develope... Overtime, reduction in the amount of heat generated in engineering systems in operations have been of great concern and have continuously been under study. It is in line with the above that this research work developed a mathematical model of an evaporative cooling pad using sintered Nigerian clay. A physical model of the evaporative cooling phenomenon was developed followed by the derivation of the governing equations describing the energy and mass transfer for the clay model from the laws of conservation of continuum mechanics. A set of reasonable and appropriate as-sumptions were imposed upon the physical model. Constitutive relationships were also developed for further analysis of the developed equations. The finite element model of numerical methods was used to analyse the energy transfer governing equations which resulted in the determination of the temperature of the exposed boundary surface at any given time, t2 after the commencement of the evaporative cooling processes. In this paper, it was found out that surface temperature differences could be as much as 6?C in the first cycle of evaporative cooling with the potential of further reduction. Further, an equation for the prediction of the effectiveness of an evaporative cooling system using clay modeled cooling pads was developed. The findings in this research work can be applied in the design, construction and maintenance of evaporative coolers used to dissipate waste heat when a large amount of natural water is not readily available or if for environmental and safety reasons the large water body can no longer absorb waste heat. 展开更多
关键词 evaporATIVE cooling NIGERIAN CLAY Finite Difference Model Energy TRANSFER cooling PAD Moulded CLAY Material Heat TRANSFER Refrigeration Temperature
下载PDF
Collision of cold CaF molecules: Towards evaporative cooling
7
作者 Yuefeng Gu Yunxia Huang +1 位作者 Chuanliang Li Xiaohua Yang 《Chinese Physics B》 SCIE EI CAS CSCD 2019年第3期161-167,共7页
Long range intermolecular interaction potential surface of CaF(~2∑^+) was simulated by employing the MOLPRO program and using the RCCSD(T)/def2-TZVP theory. The predicted data were further fitted to obtain the collis... Long range intermolecular interaction potential surface of CaF(~2∑^+) was simulated by employing the MOLPRO program and using the RCCSD(T)/def2-TZVP theory. The predicted data were further fitted to obtain the collision crosssection. The elastic collision cross-section of CaF at the temperature around 2 mK is as high as 6.5 × 10^(-9) cm^2 and the collision rate is over 4.1 × 10~6 Hz. Additionally, we found that an orientation electric field will simplify the intermolecular interaction potential function from quaternary into ternary and the collision cross-section will be raised by about three orders. All-optical evaporative cooling of cold CaF is discussed in the conclusion. 展开更多
关键词 INTERMOLECULAR interaction potential energy surface COLD COLLISION evaporATIVE cooling
下载PDF
Surface-induced evaporative cooling
8
作者 柯敏 颜波 +1 位作者 程锋 王育竹 《Chinese Physics B》 SCIE EI CAS CSCD 2009年第10期4274-4280,共7页
The effects of surface-induced evaporative cooling on an atom chip are investigated. The evolutions of temperature, number and phase-space density of the atom cloud are measured when the atom cloud is brought close to... The effects of surface-induced evaporative cooling on an atom chip are investigated. The evolutions of temperature, number and phase-space density of the atom cloud are measured when the atom cloud is brought close to the surface. Rapid decrease of the temperature and number of the atoms is found when the atom-surface distance is 〈 100 ttm. A gain of about a factor of five on the phase-space density is obtained. It is found that the efficiency of the surface-induced evaporative cooling depends on the atom-surface distance and the shape of the evaporative trap. When the atoms are moved very close to the surface, severe heating is observed, which dominates when the holding time is 〉 8 ms. It is important that the surface-induced evaporative cooling offers novel possibilities for the realization of a continuous condensation, where a spatially varying evaporative cooling is required. 展开更多
关键词 atom chip atom-surface distance surface-induced evaporative cooling
下载PDF
Experimental investigation of evaporative cooling mixture of bosonic ^(87)Rb and fermionic ^(40)K atoms with microwave and radio frequency radiation
9
作者 王鹏军 熊德智 +1 位作者 付正坤 张靖 《Chinese Physics B》 SCIE EI CAS CSCD 2011年第1期515-520,共6页
We investigate sympathetic cooling fermions 40K by evaporatively cooling bosonic 87Rb atoms in a magnetic trap with microwave and radio frequency induced evaporations in detail. The mixture of bosonic and fermionic at... We investigate sympathetic cooling fermions 40K by evaporatively cooling bosonic 87Rb atoms in a magnetic trap with microwave and radio frequency induced evaporations in detail. The mixture of bosonic and fermionic atoms is prepared in their polarized spin states IF = 9/2, mF = 9/2) for 40K and IF = 2, mF=2〉 for 87Rb, which is trapped in Quadrupole-Ioffe-Configuration trap. Comparing microwave with radio frequency evaporatively cooling bosonic STRb atoms with sympathetically cooling Fermi gas 40K, we find that the presence of rubidium atoms in the [2, 1} Zeeman states, which are generated in the evaporative process, gives rise to a significant loss of 40K due to inelastic collisions. Thus, the rubidium atoms populated in the [2, 1} Zeeman states should be removed in order to effectively perform sympathetically cooling 40K with the evaporatively cooled STRb atoms. 展开更多
关键词 microwave and radio frequency induced evaporation sympathetically cooling inelasticcollisions
下载PDF
Light-induced evaporative cooling in a magneto-optical trap
10
作者 马红玉 成华东 +1 位作者 王育竹 刘亮 《Chinese Physics B》 SCIE EI CAS CSCD 2008年第11期4180-4183,共4页
This paper presents an experimental demonstration of light-induced evaporative cooling in a magneto-optical trap. An additional laser is used to interact with atoms at the edge of the atomic cloud in the trap. These a... This paper presents an experimental demonstration of light-induced evaporative cooling in a magneto-optical trap. An additional laser is used to interact with atoms at the edge of the atomic cloud in the trap. These atoms get an additional force and evaporated away from the trap by both the magnetic field and laser fields. The remaining atoms have lower kinetic energy and thus are cooled. It reports the measurements on the temperature and atomic number after the evaporative cooling with different parameters including the distance between the laser and the centre of the atomic cloud, the detuning, the intensity. The results show that the light-induced evaporative cooling is a way to generate an ultra-cold atom source. 展开更多
关键词 evaporative cooling magneto-optical trap
下载PDF
The Effects of Evaporative Cooling on Folliculogenesis and Ovarian Hormones during the Estrous Cycle of Dairy Holstein Cows during the Summer Months in Saudi Arabia
11
作者 Mohamed Jafar Al-Hassan 《Open Journal of Veterinary Medicine》 2018年第10期175-185,共11页
Heat stress is identified as a major cause of lower productive and reproductive performance in animal farming. This situation is more common in Saudi Arabia than in other countries because of extremely high ambient te... Heat stress is identified as a major cause of lower productive and reproductive performance in animal farming. This situation is more common in Saudi Arabia than in other countries because of extremely high ambient temperatures experienced during the summers. The evaporative cooling cow group had significantly increased serum E2 concentrations on days 7 and 14 - 19 of their estrous cycles, and significantly decreased serum P4 concentrations on days 7 - 18 of their estrous cycles. Evaporative cooling plus shade lowered ambient temperatures (41.80 ± 0.74 versus 47.40?C ± 0.84?C) have increased the relative humidity (0.33 ± 0.01 versus 0.24 ± 0.01) and decreased the temperature humidity index (80.24 ± 0.60 versus 84.77 ± 0.68) when compared with shade alone. However, cows under shade alone, compared to cows under evaporative cooling with shade, had a larger number of small (10.04 ± 0.54 versus 4.72 ± 0.58), medium (2.80 ± 0.21 versus 1.79 ± 0.17), and large follicles (6.82 ± 0.28 versus 5.66 ± 0.22). These results demonstrated that while evaporative cooling had positive effects on dairy cows in this experiment, changes could have been more profound, if installations of curtains and fans were implemented, which might need further investigation. 展开更多
关键词 evaporATIVE cooling FOLLICULOGENESIS Heat Stress E2 and P4
下载PDF
Modeling and Simulation of Evaporative Cooling System in Controlled Environment Greenhouse
12
作者 Faten Hosney Fahmy Hanaa Mohamed Farghally +1 位作者 Ninet Mohamed Ahmed A. A. Nafeh 《Smart Grid and Renewable Energy》 2012年第1期67-71,共5页
Greenhouses are used for the main purpose of improving the environmental conditions in which plants are grown. There are many parameters can affect the growing of plants inside greenhouse, such as air temperature and ... Greenhouses are used for the main purpose of improving the environmental conditions in which plants are grown. There are many parameters can affect the growing of plants inside greenhouse, such as air temperature and relative humidity. The adjustment of these parameters is achieved by selecting appropriate control actions. This work proposes a controlling technique for greenhouse indoor temperature and relative humidity. The proposed greenhouse cooling system temperature controller is designed to adjust the air volume flow rate in pad-fan cooling system to fix the greenhouse indoor temperature at 20?C and 70% relative humidity. The designed control technique is realized to ensure the required and continuous operation of the greenhouse. Moreover, this work present, a complete mathematical modeling and simulation of cooling system is introduced. In addition, a computer model based on MATLAB SIMULINK software has been used to predict the temperature and relative humidity profiles inside the greenhouse. The results are realized the requirements of the greenhouse cooling system environment. 展开更多
关键词 Pad-Fan evaporATIVE cooling System PI CONTROLLER and GREENHOUSE
下载PDF
Observation of Atomic Dynamic Behaviors in the Evaporative Cooling by In-Situ Imaging the Plugged Hole of Ultracold Atoms
13
作者 Tian-You Gao Dong-Fang Zhang +2 位作者 Ling-Ran Kong Rui-Zong Li Kai-Jun Jiang 《Chinese Physics Letters》 SCIE CAS CSCD 2018年第8期58-61,共4页
We experimentally observe the dynamic evolution of atoms in the evaporative cooling, by in-situ imaging the plugged hole of ultracold atoms. Ultracold rubidium atoms confined in a magnetic trap are plugged using a blu... We experimentally observe the dynamic evolution of atoms in the evaporative cooling, by in-situ imaging the plugged hole of ultracold atoms. Ultracold rubidium atoms confined in a magnetic trap are plugged using a blue-detuned laser beam with a waist of 20 m at a wavelength of 767 nm. We probe the variation of the atomic temperature and width versus the radio frequency in the evaporative cooling. Both the behaviors are in good agreement with the calculation of the trapping potential dressed by the rf signal above the threshold temperature,while deviating from the calculation near the phase transition. To accurately obtain the atomic width, we use the plugged hole as the reference to optimize the optical imaging system by precisely minimizing the artificial structures due to the defocus effect. 展开更多
关键词 Observation of Atomic Dynamic Behaviors in the evaporative cooling by In-Situ Imaging the Plugged Hole of Ultracold Atoms
下载PDF
Modelling and Solution of a Ablation-Transpiration Cooling Control Systems
14
作者 郭宝珠 郝涌 《Journal of Beijing Institute of Technology》 EI CAS 1994年第2期114-121,共8页
A controlled model of thermal shield of ablation with trapspiration cooling is develoed. The existence and uniqueness of the classical solution can be obtained by Friedman and Jiang's methods. The positivity of th... A controlled model of thermal shield of ablation with trapspiration cooling is develoed. The existence and uniqueness of the classical solution can be obtained by Friedman and Jiang's methods. The positivity of the solution is proved and the conditions for the coolant flux under which the abladtion process will complete in finite time are also determined. Finally, we show the existence of critical coolant flux beyond which the ablation material begin melting. 展开更多
关键词 ablation evaporative cooling dristributed parameter system the boundary
下载PDF
Studying the Role Played by Evaporative Cooler on the Performance of GE Gas Turbine Existed in Shuaiba North Electric Generator Power Plant 被引量:1
15
作者 O. R. AL-Hamdan A. A. Saker 《Energy and Power Engineering》 2013年第6期391-400,共10页
It’s well known that the performance of a gas turbine (efficiency, heat rate and power generated) is largely dependent on mass flow rate of air, inlet air temperature and turbine inlet temperature (TIT). As turbine i... It’s well known that the performance of a gas turbine (efficiency, heat rate and power generated) is largely dependent on mass flow rate of air, inlet air temperature and turbine inlet temperature (TIT). As turbine inlet temperature is dependent on quantity of burned fuel so that this factor is dropped out from this paper. It’s also known that gas turbines are constant volume machines i.e. at a given shaft speed they always move the same volume of air, but the power out-put of a turbine depends on the flow of mass through it. This is precisely the reason why on hot days, when air is less dense, power output falls off. A rise of one degree Centigrade temperature of inlet air decreases the power output by 1% and at the same time heat rate of the turbine also goes up. This is a matter of great concern to power producers. Many techniques have been developed to cool the inlet air to gas turbine. Some of these techniques to decrease the inlet air temperature are discussed here. The evaporative cooling technique is taken as a case study in this paper. A comparative studying is carried out between a unit using this technique and the same unit when the evaporative cooler is idle. The results advert to an increase in power output by 11.07% and a decrease in heat rate by approximately 4% when inlet air temperature drops from 50°C to 26°C. 展开更多
关键词 Gas TURBINE SHAFT Speed Power Output The evaporATIVE cooling Technique
下载PDF
Technology and Studies for Greenhouse Cooling
16
作者 Hugang Li Shuangxi Wang 《World Journal of Engineering and Technology》 2015年第3期73-77,共5页
Greenhouse technology is an efficient and viable option, especially for the sustainable crop production in the regions of adverse climatic conditions. High summer temperature is one of the worst effects on greenhouse ... Greenhouse technology is an efficient and viable option, especially for the sustainable crop production in the regions of adverse climatic conditions. High summer temperature is one of the worst effects on greenhouse crop production throughout the year. The main purpose of this paper is to present some technologies and studies for greenhouse cooling in summer. In the paper, some applicable and practical cooling technologies have been discussed. The choice of efficient cooling method depends on many aspects, such as local climate, agronomic condition, design and covering materials. To achieve desirable benefits, the combination of different cooling methods is necessarily used. Analysis of earlier studies revealed that a naturally ventilated greenhouse with larger ventilation areas (15% - 30%), provided at the ridge and side covered with insect-proof nets of 20 - 40 mesh size with covering material properties of NIR (near infrared radiation) reflection during the day and FIR (far infrared radiation) reflection during night was suitable for greenhouse production throughout year in some special regions. Evaporation cooling is the most effective cooling method for controlling the temperature and humidity inside a greenhouse. However, its suitability is restricted to the respective region and climate when the humidity level is high. The entry of unwanted radiation or light can be controlled by the use of shading. Researches show that shade net application with different perforated mesh size and their evaluation with respect to local climate and region are necessary to get cooling benefits in summer. 展开更多
关键词 GREENHOUSE cooling Technologies and STUDIES NATURAL Ventilation evaporation cooling SHADING
下载PDF
Experimental Study on the Thermal Performances of a Tube-Type Indirect Evaporative Cooler
17
作者 Tiezhu Sun Huan Sun +2 位作者 Tingzheng Tang Yongcheng Yan Peixuan Li 《Fluid Dynamics & Materials Processing》 EI 2023年第10期2519-2531,共13页
The so-called indirect evaporative cooling technology is widely used in air conditioning applications.The thermal characterization of tube-type indirect evaporative coolers,however,still presents challenges which need... The so-called indirect evaporative cooling technology is widely used in air conditioning applications.The thermal characterization of tube-type indirect evaporative coolers,however,still presents challenges which need to be addressed to make this technology more reliable and easy to implement.This experimental study deals with the performances of a tube-type indirect evaporative cooler based on an aluminum tube with a 10 mm diameter.In particular,the required tests were carried out considering a range of dry-bulb temperatures between 16℃ and 18℃ and a temperature difference between the wet-bulb and dry-bulb temperature of 2℃∼4℃.The integrated convective heat transfer coefficient inside the tube in the drenching condition has been found to lie in the range between 36.10 and 437.4(W/(m^(2)⋅K)). 展开更多
关键词 Tubular indirect evaporative cooler integrated convection heat transfer coefficient evaporative cooling thermal engineering calculation energy saving
下载PDF
Applying Neural Network in Evaporative Cooler Performance Prediction
18
作者 强天伟 沈恒根 +1 位作者 黄翔 宣永梅 《Journal of Donghua University(English Edition)》 EI CAS 2007年第3期400-403,共4页
The back-propagation (BP) neural network is created to predict the performance of a direct evaporative cooling (DEC) air conditioner with GLASdek pads. The experiment data about the performance of the DEC air cond... The back-propagation (BP) neural network is created to predict the performance of a direct evaporative cooling (DEC) air conditioner with GLASdek pads. The experiment data about the performance of the DEC air conditioner are obtained. Some experiment data are used to train the network until these data can approximate a function, then, simulate the network with the remanent data. The predicted result shows satisfying effects. 展开更多
关键词 neural network direct evaporative cooling airconditioner evaporative cooler) TRAIN simulate
下载PDF
Evaporation Heat Transfer Characteristics from a Sintered Powder Wick Structure Sandwiched between Two Solid Walls
19
作者 Yasushi Koito Shoma Hitotsuya +1 位作者 Takamitsu Takayama Kenta Hashimoto 《Frontiers in Heat and Mass Transfer》 EI 2023年第1期33-46,共14页
An ultra-thin flattened heat pipe has been developed with a centered wick structure.This structure is essential to make the heat pipe thinner.However,the centered wick structure reduces the evaporation and condensatio... An ultra-thin flattened heat pipe has been developed with a centered wick structure.This structure is essential to make the heat pipe thinner.However,the centered wick structure reduces the evaporation and condensation surface areas of the wick structure because it is sandwiched between heat pipe walls.In this study,because detailed discussion has not been made,heat transfer experiments were conducted for the wick structure sandwiched between two solid walls.This study focused on the evaporation heat transfer characteristics from the sandwiched wick structure.The experiments were conducted with three wick structures,that is,strip-shaped sintered copper powders with thicknesses of 0.5,1.0,and 1.5 mm.Water was used as working fluid.The capillary pumping performance,that is,the liquid lifting velocities of the three wick structures were the same.The experimental results of the three wick structures were compared regarding the relation between the evaporation heat transfer rate and the superheat of the working fluid.The heat transfer experiments were also conducted when one of the solid walls was removed from the wick structure.It was confirmed that even if the wick structure was sandwiched between the solid walls,sufficient evaporation of the working fluid occurred from the thin sides of the wick structure. 展开更多
关键词 Heat transfer ultra-thin heat pipe centered wick structure restricted evaporation surface thermal design electronics cooling
下载PDF
Case Study of Indirect Adiabatic Cooling System in Historical Building
20
作者 Art.s Brahrnanis Armrs Lesinskis Andris Krumins 《Journal of Energy and Power Engineering》 2014年第2期313-317,共5页
The objective of the present study is to investigate the efficiency of indirect adiabatic chiller-based cooling system efficiency dependence of outdoor air humidity. The system is located in historical building, in te... The objective of the present study is to investigate the efficiency of indirect adiabatic chiller-based cooling system efficiency dependence of outdoor air humidity. The system is located in historical building, in temperate climate of Latvia. The data about electricity consumption, water consumption, chiller operation stages, cooling average temperatures and outdoor air parameters have been acquired for the period of 2.5 month, during the cooling season. Using data collected by BACnet based BMS controllers and adiabatic chiller control system, we have analyzed operation efficiency of the chiller and its dependence of outdoor air humidity. Data range for the period from August 1st till October 13th, 2011 was taken for deeper analysis, which showed that in temperature range 22.0 ± 0.5 ℃ for the studied period of time chiller's COP is slightly dependent on the outdoor air moisture. 展开更多
关键词 Indirect evaporative cooling historical building.
下载PDF
上一页 1 2 91 下一页 到第
使用帮助 返回顶部