期刊文献+
共找到18,659篇文章
< 1 2 250 >
每页显示 20 50 100
Unloading and successful treatment with bioresorbable stents during percutaneous coronary intervention:A case report 被引量:2
1
作者 Tao Sun Ming-Xue Zhang +7 位作者 Yan Zeng Li-Hua Ruan Yi Zhang Cheng-Long Yang Zhang Qin Jing Wang Hai-Mei Zhu Yun Long 《World Journal of Cardiology》 2024年第8期484-490,共7页
BACKGROUND With the development of percutaneous coronary intervention(PCI),the number of interventional procedures without implantation,such as bioresorbable stents(BRS)and drug-coated balloons,has increased annually.... BACKGROUND With the development of percutaneous coronary intervention(PCI),the number of interventional procedures without implantation,such as bioresorbable stents(BRS)and drug-coated balloons,has increased annually.Metal drug-eluting stent unloading is one of the most common clinical complications.Comparatively,BRS detachment is more concealed and harmful,but has yet to be reported in clinical research.In this study,we report a case of BRS unloading and successful rescue.This is a case of a 59-year-old male with the following medical history:“Type 2 diabetes mellitus”for 2 years,maintained with metformin extended-release tablets,1 g PO BID;“hypertension”for 20 years,with long-term use of metoprolol sustained-release tablets,47.5 mg PO QD;“hyperlipidemia”for 20 years,without regular medication.He was admitted to the emergency department of our hospital due to intermittent chest pain lasting 18 hours,on February 20,2022 at 15:35.Electrocardiogram results showed sinus rhythm,ST-segment elevation in leads I and avL,and poor R-wave progression in leads V1–3.High-sensitivity troponin I level was 4.59 ng/mL,indicating an acute high lateral wall myocardial infarction.The patient’s family requested treatment with BRS,without implanta-tion.During PCI,the BRS became unloaded but was successfully rescued.The patient was followed up for 2 years;he had no episodes of angina pectoris and was in generally good condition.CONCLUSION We describe a case of a 59-year-old male experienced BRS unloading and successful rescue.By analyzing images,the causes of BRS unloading and the treatment plan are discussed to provide insights for BRS release operations.We discuss preventive measures for BRS unloading. 展开更多
关键词 Coronary artery diseases Percutaneous coronary intervention Bioresorbable stents stent unloading stent release Intravascular ultrasound Case report
下载PDF
Longitudinal stent compression of everolimus-eluting stent: A report of 2 cases 被引量:1
2
作者 Rajesh Vijayvergiya Alok Kumar +1 位作者 Smit Shrivastava Naveen K Kamana 《World Journal of Cardiology》 CAS 2013年第8期313-316,共4页
Second generation drug eluting stents(DES) have shown better safety and efficacy in comparison to first generation DES,because of thinner struts,nondurable polymers and coating with better anti-proliferative drugs.The... Second generation drug eluting stents(DES) have shown better safety and efficacy in comparison to first generation DES,because of thinner struts,nondurable polymers and coating with better anti-proliferative drugs.The newer DES with cobalt alloy base have demonstrated a greater trackability,deliverability,conformability,flexibility and radio-opacity.However,these thin strut stents have a downside of poor longitudinal axial strength,and therefore get easily deformed/ compressed at their end with a slight trauma during exchange of various catheters.We hereby report two cases of "longitudinal stent compression(LSC)" of everolimus-eluting stent,which happened during percutaneous coronary intervention of right coronary artery.Both the cases were successfully managed with non-compliant balloon dilatation.Various reasons for LSC and its management are discussed in the article. 展开更多
关键词 COMPLICATION everolimus-eluting stent Longitudinal stent compression PERCUTANEOUS CORONARY intervention stent structure stent deformation
下载PDF
Outcomes of a non-randomised audit of single pigtail suture stents in urolithiasis management of Asian patients in Singapore
3
作者 Ee Jean Lim Zhen Wei Choo +8 位作者 Reshma Mangat Pradeep Durai Sarvajit Biligere Yiquan Tan Loh Hin Yeung Marcus Nicole Andrea Seet Li Ting Chin Tiong Heng Stefania Ferreti Vineet Gauhar 《Asian Journal of Urology》 CSCD 2024年第2期324-330,共7页
Objective:Double-J(DJ)ureteric stents are commonly placed perioperatively for semirigid or flexible ureteroscopic renal surgery.It is believed that lesser stent material within the bladder mitigates stent-related symp... Objective:Double-J(DJ)ureteric stents are commonly placed perioperatively for semirigid or flexible ureteroscopic renal surgery.It is believed that lesser stent material within the bladder mitigates stent-related symptoms.This study aimed to evaluate the J-Fil ureteral stent,a single pigtail suture stent compared with conventional DJ stent in relation to stent symptoms in an Asian population undergoing ureterorenal intervention.Methods:Based on internal audit committee recommendation approval,the records of 50 patients retrieved,available data of 41 patients who were prospectively enrolled into two groups(Group 1[J-Fil stent group],n=21 and Group 2[DJ stent group],n=20)between August 2020 to January 2021,were analysed.Parameters compared were nature of procedure,stone location and size,ease of deployment or removal,and complications.A modified universal stent symptom questionnaire was used to assess morbidity of stent symptoms within 48 h of insertion and at removal.Results:Both groups had similar median age,distribution in male to female ratio,and stone size.The overall median universal stent symptom questionnaire score at insertion was similar for bladder pain,flank or loin pain,and quality of life between Group 1 and 2;however,at removal Group 1 fared significantly better than Group 2,especially for flank or loin pain and pain at voiding.Both groups had similar ease in insertion with no hospital readmissions.Conclusion:Our audit favoured the single pigtail suture stent in Asian ureters in mitigating stent-related issues.It showed a good safety profile with easy deployment and removal.It promises a new standard in stenting. 展开更多
关键词 stent URETEROSCOPY Pigtail suture stent Asianpatient Flexible ureteroscopic renal surgery
下载PDF
Can we predict the incidence of high-grade Clavien-Dindo complications in patients with forgotten encrusted stents undergoing endourologic management?
4
作者 Praanjal Gupta Ramanitharan Manikandan +3 位作者 Lalgudi Narayanan Dorairajan Kodakattil Sreenivasan Sreerag Sidhartha Kalra Swapnil Singh Kushwaha 《Asian Journal of Urology》 CSCD 2024年第1期99-104,共6页
Objective:Ureteral stents are customarily inserted to facilitate urinary drainage,but they come with their own glitches of being forgotten and/or encrusted leading to serious consequences.The present study aimed to re... Objective:Ureteral stents are customarily inserted to facilitate urinary drainage,but they come with their own glitches of being forgotten and/or encrusted leading to serious consequences.The present study aimed to report the complications in patients with forgotten and encrusted stents according to the Clavien-Dindo system specific to urological procedures and identify the factors leading to high-grade(Clavien-Dindo Grade 4A or above)complications.Methods:The hospital records of patients with forgotten encrusted double-J stents over a period of 8 years were reviewed.The parameters recorded included patient demographics,indwelling time,need for percutaneous nephrostomy,hemodialysis,urine culture,blood culture,total blood counts,serum creatinine,radiologic findings,management techniques,number of surgical interventions,modified Clavien-Dindo complications,follow-up,and mortality,if any.Results:Forty patients were included in the study.The median age was 52(range 6-85)years.Of the total,25(62.5%)patients had a“significant”stent load;31(77.5%)had renal failure or acute kidney injury on presentation;19(47.5%)patients had sepsis at presentation.Among the patients presented with sepsis,11(57.9%)patients demonstrated a positive urine culture;and 7/11(63.6%)patients exhibited pan-resistant organisms.Twelve out of 40(30.0%)patients in our series developed high-grade Clavien-Dindo complications.On univariate analysis,sepsis at presentation(p=0.007),stent load(p=0.031),diabetes(p=0.023),positive urine culture(p=0.007),and stent indwelling time of more than 1 year(p=0.031)were found to be significant.On multivariate logistic regression analysis,sepsis at presentation(p=0.017)and positive urine culture(p=0.016)were significant predictors for high-grade complications.Conclusion:It is prudent to identify specific risk factors,namely sepsis at presentation and positive urine culture to triage and optimize these patients before surgical management. 展开更多
关键词 Forgotten Encrusted stent Outcome Predictor Clavien-Dindo complication
下载PDF
Revolutionizing palliative care:Electrocautery-enhanced lumenapposing metal stents in endoscopic-ultrasound-guided biliary drainage for malignant obstructions
5
作者 Nirmal Kumar Reddy Onteddu Naga Sai Rasagna Mareddy +2 位作者 Sai Swarupa R Vulasala Jayabharath Onteddu Mayur Virarkar 《World Journal of Gastrointestinal Surgery》 SCIE 2024年第7期2358-2361,共4页
Patients with malignant biliary obstruction,following endoscopic retrograde cholangiopancreatography(ERCP)failure could be referred for endoscopicultrasound-guided biliary drainage through electrocautery-enhanced(ECE)... Patients with malignant biliary obstruction,following endoscopic retrograde cholangiopancreatography(ERCP)failure could be referred for endoscopicultrasound-guided biliary drainage through electrocautery-enhanced(ECE)lumen-apposing metal stent(LAMS)placement.However,the efficacy and safety of ECE-LAMS in this scenario have remained debatable due to minimal scientific evidence.The current confirmed 91.0%clinical success,96.7%technical success,7.3%reintervention rate,and 17.5%adverse events,following the treatment of malignant biliary obstruction with ECE-LAMS delivery.Finally,ECE-LAMS proved to be a generalizable strategy for managing biliary obstruction for patients who were excluded from ERCP. 展开更多
关键词 Endoscopic retrograde cholangiopancreatography Electrocautery-enhancedlumen-apposing metal stent Biliary drainage Biliary stent Endoscopic ultrasound
下载PDF
Defining failure of endoluminal biliary drainage in the era of endoscopic ultrasound and lumen apposing metal stents
6
作者 Faisal S Ali Sushovan Guha 《World Journal of Gastroenterology》 SCIE CAS 2024年第29期3534-3537,共4页
The role of endoscopy in pathologies of the bile duct and gallbladder has seen notable advancements over the past two decades.With advancements in stent technology,such as the development of lumen-apposing metal stent... The role of endoscopy in pathologies of the bile duct and gallbladder has seen notable advancements over the past two decades.With advancements in stent technology,such as the development of lumen-apposing metal stents,and adoption of endoscopic ultrasound and electrosurgical principles in therapeutic endoscopy,what was once considered endoscopic failure has transformed into failure of an approach that could be salvaged by a second-or third-line endoscopic strategy.Incorporation of these advancements in routine patient care will require formal training and multidisciplinary acceptance of established techniques and collaboration for advancement of experimental techniques to generate robust evidence that can be utilized to serve patients to the best of our ability. 展开更多
关键词 Endoscopic ultrasound Guided biliary drainage GALLBLADDER Biliary obstruction Lumen-apposing metal stent
下载PDF
Long-term outcomes of titanium-nitride-oxide coated stents and drug-eluting stents in acute coronary syndrome:A systematic review and meta-analysis
7
作者 Muhammad Ahmed Ali Fahim Afia Salman +12 位作者 Hira Anas Khan Syed Muhammad Hasan Muskan FatimaBhojani Sarah Aslam Amna Zia Ul Haq Vishal Reddy Bejugam Beena Muntaha Nasir Wajiha Gul Abdul Moeed Abdelrahman S Abdalla Muhammad Majid Muhammad Sohaib Asghar Md Al Hasibuzzaman 《World Journal of Cardiology》 2024年第5期293-305,共13页
BACKGROUND In severe cases of coronary artery disease,percutaneous coronary intervention provide promising results.The stent used could be a drug-eluting stent(DES)or a titanium-nitride-oxide coated stent(TiNOS).AIM T... BACKGROUND In severe cases of coronary artery disease,percutaneous coronary intervention provide promising results.The stent used could be a drug-eluting stent(DES)or a titanium-nitride-oxide coated stent(TiNOS).AIM To compare the 5-year effectiveness and safety of the two stent types.METHODS The following systematic review and meta-analysis was conducted in accordance with the preferred reporting items for systematic reviews and meta-analysis guidelines,and PubMed/MEDLINE,Scopus,and Cochrane Central were searched from inception till August 2023.Primary outcomes were major adverse cardiac events(MACE),cardiac death,myocardial infarction(MI),cardiac death or MI,and ischemia-driven total lesion revascularization(ID-TLR).RESULTS Four randomized controlled trials(RCT),which analyzed a sum total of 3045 patients with acute coronary syndrome(ACS)after a median follow-up time of 5 years were included.Though statistically insignificant,an increase in the ID-TLR was observed in patients receiving TiNOSs vs DESs.In addition,MI,cardiac death and MI,and definite stent thrombosis(DST)were significantly decreased in the TiNOS arm.Baseline analysis revealed no significant results with meta-regression presenting non-ST elevated MI(NSTEMI)as a statistically significant covariate in the outcome of MACE.CONCLUSION TiNOS was found to be superior to DES in terms of MI,cardiac death or MI,and DST outcomes,however,the effect of the two stent types on ID-TLR and MACE was not significant.A greater number of studies are required to establish an accurate comparison of patient outcomes in TiNOS and DES. 展开更多
关键词 stents DRUG-ELUTING Major adverse cardiac events All-cause death META-ANALYSIS
下载PDF
Unveiling the potential of electrocautery-enhanced lumen-apposing metal stents in endoscopic ultrasound-guided biliary drainage
8
作者 Meer M Chisthi 《World Journal of Gastrointestinal Surgery》 SCIE 2024年第7期1956-1959,共4页
This editorial delves into Peng et al's article,published in the World Journal of Gastrointestinal Surgery.Peng et al's meta-analysis investigates the effectiveness of electrocautery-enhanced lumen-apposing me... This editorial delves into Peng et al's article,published in the World Journal of Gastrointestinal Surgery.Peng et al's meta-analysis investigates the effectiveness of electrocautery-enhanced lumen-apposing metal stents(ECE-LAMS)in ultrasound-guided biliary drainage for alleviating malignant biliary obstruction.Examining 14 studies encompassing 620 participants,the research underscores a robust technical success rate of 96.7%,highlighting the efficacy of ECE-LAMS,particularly in challenging cases which have failed endoscopic retrograde cholangio pancreatography.A clinical success rate of 91.0% underscores its impact on symptom alleviation,while a reasonably tolerable adverse event rate of 17.5% is observed.However,the 7.3% re-intervention rate stresses the need for post-procedural monitoring.Subgroup analyses validate consistent outcomes,bolstering the applicability of ECE-LAMS.These findings advocate for the adoption of ECELAMS as an appropriate approach for biliary palliation,urging further exploration in real-world clinical contexts.They offer valuable insights for optimizing interventions targeting malignant biliary obstruction management. 展开更多
关键词 Biliary drainage Electrocautery-enhanced lumen-apposing metal stent Endoscopic retrograde cholangiopancreatography Endoscopic ultrasound Malignant biliary obstruction
下载PDF
Safety and efficacy of Kaffes intraductal self-expanding metal stents in the management of post-liver transplant anastomotic strictures
9
作者 Chee Lim Jonathan Ng +4 位作者 Babak Sarraf Rhys Vaughan Marios Efthymiou Leonardo Zorron Cheng Tao Pu Sujievvan Chandran 《World Journal of Transplantation》 2024年第2期88-98,共11页
BACKGROUND Endoscopic management is the first-line therapy for post-liver-transplant anas-tomotic strictures.Although the optimal duration of treatment with plastic stents has been reported to be 8-12 months,data on s... BACKGROUND Endoscopic management is the first-line therapy for post-liver-transplant anas-tomotic strictures.Although the optimal duration of treatment with plastic stents has been reported to be 8-12 months,data on safety and duration for metal stents in this setting is scarce.Due to limited access to endoscopic retrograde cholan-giopancreatography(ERCP)during the coronavirus disease 2019 pandemic in our centre,there was a change in practice towards increased usage and length-of-stay of the Kaffes biliary intraductal self-expanding stent in patients with suitable anatomy.This was mainly due to the theoretical benefit of Kaffes stents allowing for longer indwelling periods compared to the traditional plastic stents.METHODS Adult liver transplant recipients aged 18 years and above who underwent ERCP were retrospectively identified during a 10-year period through a database query.Unplanned admissions post-Kaffes stent insertion were identified manually through electronic and scanned medical records.The main outcome was the incidence of complications when stents were left indwelling for 3 months vs 6 months.Stent efficacy was calculated via rates of stricture recurrence between patients that had stenting courses for≤120 d or>120 d.RESULTS During the study period,a total of 66 ERCPs with Kaffes insertion were performed in 54 patients throughout their stenting course.In 33 ERCPs,the stent was removed or exchanged on a 3-month interval.No pancreatitis,perfor-ations or deaths occurred.Minor post-ERCP complications were similar between the 3-month(abdominal pain and intraductal migration)and 6-month(abdominal pain,septic shower and embedded stent)groups-6.1%vs 9.1%respectively,P=0.40.All strictures resolved at the end of the stenting course,but the stenting course was variable from 3 to 22 months.The recurrence rate for stenting courses lasting for up to 120 d was 71.4%and 21.4%for stenting courses of 121 d or over(P=0.03).There were 28 patients that were treated with a single ERCP with Kaffes,21 with removal after 120 d and 7 within 120 d.There was a significant improvement in stricture recurrence when the Kaffes was removed after 120 d when a single ERCP was used for the entire stenting course(71.0%vs 10.0%,P=0.01).CONCLUSION Utilising a single Kaffes intraductal fully-covered metal stent for at least 4 months is safe and efficacious for the management of post-transplant anastomotic strictures. 展开更多
关键词 Liver transplantation CHOLANGIOPANCREATOGRAPHY Endoscopic retrograde CONSTRICTION PATHOLOGIC Self expandable metallic stents Bile duct diseases CHOLESTASIS
下载PDF
Research on the Status Quo and Optimization of Centralized Procurement of Coronary Stents
10
作者 Zhang Yuting Liu Xiaoxi 《Asian Journal of Social Pharmacy》 2024年第1期20-28,共9页
Objective To study the impact of the first national centralized procurement of coronary stents on patients’psychology,the economy of medical institutions,and the survival and development of the coronary stents indust... Objective To study the impact of the first national centralized procurement of coronary stents on patients’psychology,the economy of medical institutions,and the survival and development of the coronary stents industry,and to provide suggestions on perfecting procedures to better carry out the centralized procurement of coronary stents.Methods Literature analysis was used to investigate the results of the procurement of coronary stent in a province and a hospital.Results and Conclusion The centralized procurement of coronary stents has alleviated the economic pressure of patients,but it has many problems.Therefore,this paper proposes some suggestions,such as promoting the orderly development of the coronary stent industry,improving the evaluation link of the centralized procurement of coronary stents,adopting the accurate reporting model to ensure the quality of coronary stents and improving the standardization of clinical services. 展开更多
关键词 volume procurement coronary stent medical resource
下载PDF
Preliminary Clinical Outcomes after Implantation of Newer-Generation Biodegradable Polymer-Coated Everolimus-Eluting Stent in “Real-World” Patients with Coronary Artery Disease
11
作者 Manjinder Singh Sandhu Harish Sanadhya +5 位作者 Shailendra Trivedi Paramu Mangalanandan Rashmit Pandya Asif Raheem Vineet Malik Bharat Chanana 《World Journal of Cardiovascular Diseases》 2016年第12期468-476,共10页
Background and Objective: In the contemporary practice, the use of drug-eluting stents is still associated with low mortality benefits, restenosis and stent thrombosis. To address these issues, newer generation, thin-... Background and Objective: In the contemporary practice, the use of drug-eluting stents is still associated with low mortality benefits, restenosis and stent thrombosis. To address these issues, newer generation, thin-strut, biodegradable polymer coated stents has been designed. Thus, the aim of the study is to assess the safety and clinical performance of the Everoflex (Sahajanand Medical Technologies Pvt. Ltd., Surat, India), a newer generation biodegradable polymer coated everolimus-eluting stent, in unselected “real-world” patients with coronary artery disease. Methods: It is a multicentre, retrospective, non-randomized, single-arm study enrolling all the consecutive patients who underwent implantation with the Everoflex for coronary artery disease from April 2014 to March 2016. The primary end-point of the study is 30-day major adverse cardiovascular events (MACE) rate, which consists of cardiac death, myocardial infarction, target lesion revascularization and target vessel revascularization. Stent thrombosis was also analyzed and reported. Results: A total of 340 patients were intervened successfully with 395 everolimus eluting stents (1.3 ± 0.6 stents per patient). Out of total patients (58.7 ± 10.5 years), 77.9% were male and comorbidities like diabetes and hypertension were observed in 31.2% and 35.3% patients, respectively. According to ACC/AHA classification, there were 34.4% type B lesions and 53.2% type C lesions, indicating a higher proportion of complexity involved. Moreover, 57.9% patients had multivessel disease and there were 15.4% total occlusions. At 30 days, follow-up was completed in 100% patients. The MACE was found to be 1.5%, which is a composite of 1.2% cardiac death and 0.3% target lesion revascularization. Stent thrombosis at 30 days was found to be 0.3%. Conclusion: The low incidence of MACE and stent thrombosis clearly depicts excellent safety and clinical performance of the Everoflex in unselected real world patients with coronary artery disease. 展开更多
关键词 Drug-Eluting stents EVEROLIMUS Biodegradable Polymer Treatment Outcome
下载PDF
Safety and Efficacy of a Novel Everolimus-Eluting Stent System in “Real-World” Patients with Coronary Artery Disease: A Report of Preliminary Outcomes
12
作者 Sridhar Kasturi Srinivas Polasa +6 位作者 Shailender Singh Vijay Kumar Reddy Kondal Rao Ganesh Mathan Shiva Kumar Bandimida Manikandhar Pendyala Chandrashekar Challa 《World Journal of Cardiovascular Diseases》 2016年第12期458-467,共11页
Introduction: Tetrilimus (Sahajanand Medical Technologies Pvt. Ltd., Surat, India) is a recently-introduced biodegradable-polymer coated everolimus-eluting cobalt-chromium coronary stent system with an ultra-thin stru... Introduction: Tetrilimus (Sahajanand Medical Technologies Pvt. Ltd., Surat, India) is a recently-introduced biodegradable-polymer coated everolimus-eluting cobalt-chromium coronary stent system with an ultra-thin strut thickness. We aimed to evaluate the clinical outcomes with Tetrilimus coronary stents in “real-world” patients with coronary artery disease. Methods: In this retrospective, single-arm, open-label, multi-center registry, all consecutive patients who received Tetrilimus stents between July-2015 and April-2016 at two tertiary-care centers in India were analyzed. Primary endpoint was 30-day incidence of major adverse cardiac events (MACE), defined as a composite of cardiac death, myocardial infarction, target lesion revascularization, and target vessel revascularization. The Academic Research Consortium (ARC)-defined stent thrombosis was assessed as additional safety endpoint. Results: During the study period, 280 Tetrilimus stents (1.4 ± 0.5 stent/patient) were implanted to treat 252 coronary lesions (1.1 ± 0.3 stent/lesion) in 208 patients (age: 57.5 ± 11.9 years). Of study population, 65.9% were males, 46.6% were hypertensives, 25% were diabetics, 36.5% were alcoholics, 29.3% were smokers, 13.9% were tobacco chewers, 5.3% had previous revascularization, and 45.2% displayed multi-vessel disease. Of treated lesions, 67.5% were complex and 18.7% had total occlusion. Average length and diameter of implanted stents were 25.5 ± 8.8 mm and 2.9 ± 0.3 mm respectively. Subsequently, 30-day MACE were reported in 2 (0.96%) patients;both cases owing to in-hospital cardiac deaths. Events of stent thrombosis or noncardiac death were not reported in any patient. Conclusion: Low MACE rates and absence of stent thrombosis at early 30-day follow-up indicates that Tetrilimus everolimus-eluting stents may have encouraging safety and efficacy in unselected “real-world” patients with coronary artery disease. 展开更多
关键词 Biodegradable Polymer Percutaneous Coronary Intervention everolimus-eluting
下载PDF
Composite bioabsorbable vascular stents via 3D bio-printing and electrospinning for treating stenotic vessels 被引量:13
13
作者 刘媛媛 向科 +2 位作者 李瑜 陈海萍 胡庆夕 《Journal of Southeast University(English Edition)》 EI CAS 2015年第2期254-258,共5页
A new type of vascular stent is designed for treating stenotic vessels. Aiming at overcoming the shortcomings of existing equipment and technology for preparing a bioabsorbable vascular stent (BVS), a new method whi... A new type of vascular stent is designed for treating stenotic vessels. Aiming at overcoming the shortcomings of existing equipment and technology for preparing a bioabsorbable vascular stent (BVS), a new method which combines 3D bio-printing and electrospinning to prepare the composite bioabsorbable vascular stent (CBVS) is proposed. The inner layer of the CBVS can be obtained through 3D bio- printing using poly-p-dioxanone (PPDO). The thin nanofiber film that serves as the outer layer can be built through electrospinning using mixtures of chitosan-PVA (poly (vinyl alcohol)). Tests of mechanical properties show that the stent prepared through 3D bio-printing combined with electrospinning is better than that prepared through 3D bio- printing alone. Cells cultivated on the CBVS adhere and proliferate better due to the natural, biological chitosan in the outer layer. The proposed complex process and method can provide a good basis for preparing a controllable drug-carrying vascular stent. Overall, the CBVS can be a good candidate for treating stenotic vessels. 展开更多
关键词 3D three-dimensional bio-printing bioabsorbable vascular stent (BVS) ELECTROSPINNING CELLPROLIFERATION composite forming
下载PDF
Stents for colorectal obstruction:Past,present,and future 被引量:10
14
作者 Eui Joo Kim Yoon Jae Kim 《World Journal of Gastroenterology》 SCIE CAS 2016年第2期842-852,共11页
Since the development of uncovered self-expanding metal stents(SEMS) in the 1990 s, endoscopic stents have evolved dramatically. Application of new materialsand new designs has expanded the indications for enteral SEM... Since the development of uncovered self-expanding metal stents(SEMS) in the 1990 s, endoscopic stents have evolved dramatically. Application of new materialsand new designs has expanded the indications for enteral SEMS. At present, enteral stents are considered the first-line modality for palliative care, and numerous types of enteral stents are under development for extended clinical usage, beyond a merely palliative purpose. Herein, we will discuss the current status and the future development of lower enteral stents. 展开更多
关键词 COLON OBSTRUCTION stent Self-expandingmetal stents Self-expanding metal stents
下载PDF
Placement of prophylactic pancreatic stents to prevent post-endoscopic retrograde cholangiopancreatography pancreatitis in high-risk patients: A meta-analysis 被引量:16
15
作者 Qing-Qing Shi Xiao-Yi Ning +2 位作者 Ling-Ling Zhan Guo-Du Tang Xiao-Ping Lv 《World Journal of Gastroenterology》 SCIE CAS 2014年第22期7040-7048,共9页
AIM: To assess the effectiveness of pancreatic stents for preventing pancreatitis in high-risk patients after endoscopic retrograde cholangiopancreatography (ERCP).
关键词 Pancreatic stent Endoscopic retrograde cholangiopancreatography PANCREATITIS HYPERAMYLASEMIA META-ANALYSIS
下载PDF
Advantages and disadvantages of biodegradable platforms in drug eluting stents 被引量:7
16
作者 Agustina Rodriguez-Granillo Bibiana Rubilar +1 位作者 Gaston Rodriguez-Granillo Alfredo E Rodriguez 《World Journal of Cardiology》 CAS 2011年第3期84-92,共9页
Coronary angioplasty with drug-eluting stent(DES)implantation is currently the most common stent procedure worldwide.Since the introduction of DES,coronary restenosis as well as the incidence of target vessel and targ... Coronary angioplasty with drug-eluting stent(DES)implantation is currently the most common stent procedure worldwide.Since the introduction of DES,coronary restenosis as well as the incidence of target vessel and target lesion revascularization have been significantly reduced.However,the incidence of very late stent thrombosis beyond the first year after stent deployment has more commonly been linked to DES than to baremetal stent(BMS)implantation.Several factors have been associated with very late stent thrombosis after DES implantation,such as delayed healing,inflammation,stent mal-apposition and endothelial dysfunction. Some of these adverse events were associated with the presence of durable polymers,which were essential to allow the elution of the immunosuppressive drug in the first DES designs.The introduction of erodable polymers in DES technology has provided the potential to complete the degradation of the polymer simultaneously or immediately after the release of the immunosuppressive drug,after which a BMS remains in place.Several DES designs with biodegradable(BIO)polymers have been introduced in preclinical and clinical studies, including randomized trials.In this review,we analyze the clinical results from 6 observational and randomized studies with BIO polymers and discuss advantages and disadvantages of this new technology. 展开更多
关键词 POLYMERS Drug eluting stents BIODEGRADABLE POLYMERS stents THROMBOSIS RESTENOSIS
下载PDF
Palliation of malignant esophageal obstruction and fistulas with self expandable metallic stents 被引量:9
17
作者 Ahmet Dobrucali Erkan Caglar 《World Journal of Gastroenterology》 SCIE CAS CSCD 2010年第45期5739-5745,共7页
AIM: To evaluate the efficacy of self expandable metallic stents (SEMS) in patients with malignant esophageal obstruction and fistulas. METHODS: SEMS were implanted in the presence of fluoroscopic guidance in patients... AIM: To evaluate the efficacy of self expandable metallic stents (SEMS) in patients with malignant esophageal obstruction and fistulas. METHODS: SEMS were implanted in the presence of fluoroscopic guidance in patients suffering from advanced and non-resectable esophageal, cardiac and invasive lung cancer between 2002 and 2009. All procedures were performed under conscious sedation. All patients had esophagus obstruction and/or fistula. In all patients who required reintervention, recurrence of dysphagia, hemorrhage, and fistula formation were indications for further endoscopy. Patients' files were scanned retrospectively and the obtained data were analyzed using SPSS 13.0 for Windows. The χ 2 test was used for categorical data and was analysis of variance for noncategorical data. Patients' long-term survival was assessed using the Kaplan-Meier method. RESULTS: Stents were successfully implanted in 90 patients using fluoroscopic guidance. Reasons for stent implantation in these patients were esophageal stricture (77/90, 85.5%), external pressure (8/90, 8.8%) and tracheo-esophageal fistula (5/90, 5.5%). Dysphagia scores (mean ± SD) were 3.37 ± 0.52 before and 0.90 ± 0.43 after stent implantation (P = 0.002). Intermittent, nonmassive hemorrhage due to the erosion caused by the distal end of the stent in the stomach occurred in only one patient who received implementation at cardioesophageal junction. Mean survival following stenting was 134.14 d (95% confidence interval: 94.06-174.21).CONCLUSION: SEMS placement is safe and effective in the palliation of dysphagia in selected patients with malignant esophageal strictures. 展开更多
关键词 ESOPHAGUS cancer Stenosis stents Complication DYSPHAGIA
下载PDF
Biodegradable stents in gastrointestinal endoscopy 被引量:11
18
作者 Vicente Lorenzo-Zú?iga Vicente Moreno-de-Vega +1 位作者 Ingrid Marín Jaume Boix 《World Journal of Gastroenterology》 SCIE CAS 2014年第9期2212-2217,共6页
Biodegradable stents(BDSs)are an attractive option to avoid ongoing dilation or surgery in patients with benign stenoses of the small and large intestines.The experience with the currently the only BDS for endoscopic ... Biodegradable stents(BDSs)are an attractive option to avoid ongoing dilation or surgery in patients with benign stenoses of the small and large intestines.The experience with the currently the only BDS for endoscopic placement,made of Poly-dioxanone,have shown promising results.However some aspects should be improved as are the fact that BDSs lose their radial force over time due to the degradable material,and that can cause stent-induced mucosal or parenchymal injury.This complication rate and modest clinical efficacy has to be carefully considered in individual patients prior to placement of BDSs.Otherwise,the price of these stents therefore it is nowadays an important limitation. 展开更多
关键词 Biodegradable stents STRICTURES ENDOSCOPY Endoscopic placement Stenoses
下载PDF
Lumen-apposing metal stents for malignant biliary obstruction: Is this the ultimate horizon of our experience? 被引量:7
19
作者 Andrea Anderloni Edoardo Troncone +4 位作者 Alessandro Fugazza Annalisa Cappello Giovanna Del Vecchio Blanco Giovanni Monteleone Alessandro Repici 《World Journal of Gastroenterology》 SCIE CAS 2019年第29期3857-3869,共13页
In the last years, endoscopic ultrasonography (EUS) has evolved from a purely diagnostic technique to a more and more complex interventional procedure, with the possibility to perform several type of therapeutic inter... In the last years, endoscopic ultrasonography (EUS) has evolved from a purely diagnostic technique to a more and more complex interventional procedure, with the possibility to perform several type of therapeutic interventions. Among these, EUS-guided biliary drainage (BD) is gaining popularity as a therapeutic approach after failed endoscopic retrograde cholangiopancreatography in distal malignant biliary obstruction (MBO), due to the avoidance of external drainage, a lower rate of adverse events and re-interventions, and lower costs compared to percutaneous trans-hepatic BD. Initially, devices created for luminal procedures (e.g., luminal biliary stents) have been adapted to the new trans-luminal EUSguided interventions, with predictable shortcomings in technical success, outcome and adverse events. More recently, new metal stents specifically designed for transluminal drainage, namely lumen-apposing metal stents (LAMS), have been made available for EUS-guided procedures. An electrocautery enhanced delivery system (EC-LAMS), which allows direct access of the delivery system to the target lumen, has subsequently simplified the classic multi-step procedure of EUS-guided drainages. EUS-BD using LAMS and ECLAMS has been demonstrated effective and safe, and currently seems one of the most performing techniques for EUS-BD. In this Review, we summarize the evolution of the EUS-BD in distal MBO, focusing on the novelty of LAMS and analyzing the unresolved questions about the possible role of EUS as the first therapeutic option to achieve BD in this setting of patients. 展开更多
关键词 Interventional ENDOSCOPIC ULTRASONOGRAPHY ENDOSCOPIC ultrasonography-guided BILIARY drainage ENDOSCOPIC ultrasonography-guided choledocho-duodenostomy BILIARY METAL stent Lumen-apposing METAL stent
下载PDF
Temporary self-expanding metallic stents for achalasia: A prospective study with a long-term follow-up 被引量:10
20
作者 Ying-Sheng Cheng Fang Ma +5 位作者 Ying-Sheng Cheng Yong-Dong Li Jun-Gong Zhao Chun-Gen Wu Ni-Wei Chen Wei-Xiong Chen 《World Journal of Gastroenterology》 SCIE CAS CSCD 2010年第40期5111-5117,共7页
AIM: To compare the efficacy of self-expanding metallic stents (SEMSs) for the long-term clinical treatment of achalasia. METHODS: Ninety achalasic patients were treated with a temporary SEMS with a diameter of 20 mm ... AIM: To compare the efficacy of self-expanding metallic stents (SEMSs) for the long-term clinical treatment of achalasia. METHODS: Ninety achalasic patients were treated with a temporary SEMS with a diameter of 20 mm (n = 30, group A), 25 mm (n = 30, group B) or 30 mm (n = 30, group C). Data on clinical symptoms, complications and treatment outcomes were collected, and follow-up was made at 6 mo and at 1, 3-5, 5-8, 8-10 and > 10 years, postoperatively.RESULTS: Stent placement was successful in all patients. Although chest pain occurrence was high, stent migration was less in group C than in groups A and B. The clinical remission rate at 5-8, 8-10 and > 10 years in group C was higher than that in the other two groups. The treatment failure rate was lower in group C (13%) than in groups A (53%) and B (27%). SEMSs in group C resulted in reduced dysphagia scores and lowered esophageal sphincter pressures, as well as normal levels of barium height and width during all the follow-up time periods. Conversely, these parameters increased over time in groups A and B. The primary patency in group C was longer than in groups A and B. CONCLUSION: A temporary SEMS with a diameter of 30 mm is associated with a superior long-term clinical efficacy in the treatment of achalasia compared with a SEMS with a diameter of 20 mm or 25 mm. 展开更多
关键词 ACHALASIA DYSPHAGIA Self-expanding metallic stents COMPARISON
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部