Abnormal SEP reflects dysfunction of the medial lemniscus and posterior cervical cord. These structures are likely to be affected in Chiari malformation. Therefore, SEP abnormalities may provide valuable information i...Abnormal SEP reflects dysfunction of the medial lemniscus and posterior cervical cord. These structures are likely to be affected in Chiari malformation. Therefore, SEP abnormalities may provide valuable information in patients with CM. However, the consistency of SEP abnormality or normality with the damage is a matter of research. Knowing whether median nerve somatosensory evoked potential (SEP) is useful in revealing subclinical damage in patients with Chiari malformation is important in the treatment and follow-up plan of the disease. The aim of this study was to investigate the relationship between median nerve SEP values and the severity of cerebellar ectopia in patients with Chiari type 1 malformation. Median nerve SEP values were obtained from 30 healthy individuals and 146 individuals with Chiari malformation. The cerebellar ectopia degree and McRae line length were measured. SEP values were not significantly different between groups. The McRae line was found to be significantly shorter in the control group than in the Chiari malformation group (p = 0.031). There was no correlation between the degree of cerebellar ectopia and the length of the McRae line (r = 0.002, p = 0.979). Neither cerebellar ectopy degree nor McRae line length had a relationship with SEP values (r = -0.153, p = 0.066;r = -0.056, p = 0.500, respectively). There was no difference in cerebellar ectopy degree or SEP values between the groups with cerebellar ectopy with and without a syrinx (p = 0.899;p = 0.080, respectively). Likewise, McRae line length was not found to be related to the presence of a syrinx (p = 0.139). Median nerve SEP examination was not beneficial for diagnosing asymptomatic-oligosymptomatic Chiari malformation as a subclinical injury, whether accompanied by syringomyelia or not.展开更多
It remains unclear whether spinal cord ischemia-reperfusion injury caused by ischemia and other non-mechanical factors can be monitored by somatosensory evoked potentials. Therefore, we monitored spinal cord ischemia-...It remains unclear whether spinal cord ischemia-reperfusion injury caused by ischemia and other non-mechanical factors can be monitored by somatosensory evoked potentials. Therefore, we monitored spinal cord ischemia-reperfusion injury in rabbits using somatosensory evoked potential detection technology. The results showed that the somatosensory evoked potential latency was significantly prolonged and the amplitude significantly reduced until it disappeared during the period of spinal cord ischemia. After reperfusion for 30-180 minutes, the amplitude and latency began to gradually recover; at 360 minutes of reperfusion, the latency showed no significant difference compared with the pre-ischemic value, while the somatosensory evoked potential amplitude in- creased, and severe hindlimb motor dysfunctions were detected. Experimental findings suggest that changes in somatosensory evoked potentia~ ~atency can reflect the degree of spinat cord ischemic injury, while the amplitude variations are indicators of the late spinal cord reperfusion injury, which provide evidence for the assessment of limb motor function and avoid iatrogenic spinal cord injury.展开更多
AIM: To evaluate the effect of sodium tungstate on visual evoked potentials(VEPs) in diabetic rats.· METHODS: Wistar rats were randomly divided into three groups as normal control, diabetic control and diabet...AIM: To evaluate the effect of sodium tungstate on visual evoked potentials(VEPs) in diabetic rats.· METHODS: Wistar rats were randomly divided into three groups as normal control, diabetic control and diabetic rats treated with sodium tungstate. Diabetes was induced by single intraperitoneal injection of streptozotocin(50 mg/kg). Sodium tungstate [40 mg/(kg·d)]was administered for 12 wk and then VEPs were recorded.Additionally, thiobarbituric acid reactive substance(TBARS) levels were measured in brain tissues.·RESULTS: The latencies of P1, N1, P2, N2 and P3 waves were significantly prolonged in diabetic rats compared with control group. Diabetes mellitus caused an increase in the lipid peroxidation process that was accompanied by changes in VEPs. However, prolonged latencies of VEPs for all components returned to control levels in sodium tungstate-treated group. The treatment of sodium tungstate significantly decreased brain TBARS levels and depleted the prolonged latencies of VEP components compared with diabetic control group.· CONCLUSION: Sodium tungstate shows protective effects on visual pathway in diabetic rats, and it can be worthy of further study for potential use.展开更多
AIM: To evaluate the use of short-duration transient visual evoked potentials(VEP) and color reflectivity discretization analysis(CORDA) in glaucomatous eyes,eyes suspected of having glaucoma,and healthy eyes.MET...AIM: To evaluate the use of short-duration transient visual evoked potentials(VEP) and color reflectivity discretization analysis(CORDA) in glaucomatous eyes,eyes suspected of having glaucoma,and healthy eyes.METHODS: The study included 136 eyes from 136 subjects: 49 eyes with glaucoma,45 glaucoma suspect eyes,and 42 healthy eyes.Subjects underwent Humphrey visual field(VF) testing,VEP testing,as well as peripapillary retinal nerve fiber layer optical coherence tomography imaging studies with post-acquisition CORDA applied.Statistical analysis was performed using means and ranges,ANOVA,post-hoc comparisons using Turkey's adjustment,Fisher's Exact test,area under the curve,and Spearman correlation coefficients.RESULTS: Parameters from VEP and CORDA correlated significantly with VF mean deviation(MD)(P〈0.05).In distinguishing glaucomatous eyes from controls,VEP demonstrated area under the curve(AUC) values of 0.64-0.75 for amplitude and 0.67-0.81 for latency.The CORDA HR1 parameter was highly discriminative for glaucomatous eyes vs controls(AUC=0.94).CONCLUSION: Significant correlations are found between MD and parameters of short-duration transient VEP and CORDA,diagnostic modalities which warrant further consideration in identifying glaucoma characteristics.展开更多
Objective: Optimization of combining electroencephalography (EEG), short latency somatosensory evoked potentials (SLSEP) and transcranial Doppler (TCD) techniques to diagnose brain death. Methods: One hundred and elev...Objective: Optimization of combining electroencephalography (EEG), short latency somatosensory evoked potentials (SLSEP) and transcranial Doppler (TCD) techniques to diagnose brain death. Methods: One hundred and eleven patients (69 males, 42 females) from the major hospitals of Zhejiang Province were examined with portable EEG, SLSEP and TCD devices. Re-examinations occurred ≤12 h later. Results: The first examination revealed that the combination of SLSEP and EEG led to more sensitive diagnoses than the combination of SLSEP and TCD. Re-examination confirmed this and also revealed that the combination of TCD and EEG was the most sensitive. Conclusion: The results show that using multiple techniques to diagnose brain death is superior to using single method, and that the combination of SLSEP and EEG is better than other combinations.展开更多
BACKGROUND: Some previous studies have shown that exercise is an important factor that affects the latencies of visual-evoked potentials (VEPs). OBJECTIVE: To investigate the effects of spending a period of time u...BACKGROUND: Some previous studies have shown that exercise is an important factor that affects the latencies of visual-evoked potentials (VEPs). OBJECTIVE: To investigate the effects of spending a period of time undergoing tennis training on the latencies of VEPs by comparing the latencies of VEPs before tennis training with those after 8 weeks of tennis training. DESIGN, TIME AND SETTING: The non-randomly concurrent controlled experiment was performed in the Department of Human Movement Sciences, Physical Education College, Shandong Normal University from April to June 2007. PARTICIPANTS: In total, 45 healthy volunteers from Shandong Normal University were selected as subjects, including 31 students majoring in physical education (11 males and 5 females participated in the tennis training plan for 8 weeks), and 14 students from other subjects. Informed consent was obtained. According to whether they were majoring in physical education or not, and whether or not they took part in tennis training, the students were divided into 3 groups: a tennis group of physical education students (n = 16) a non-tennis group of physical education students (n =15) and a non-tennis group of non-physical education students (n = 14). METHODS: The subjects in the tennis group took part in a regular tennis training plan of 2 hours a day and 3 days per week, for 8 weeks, while the subjects in two non-tennis groups were not in the tennis training plan The NDI-200 neural electricity tester (Shanghai Haishen Medical Electronic Instrument Co., Ltd.) was used to measure VEPs before and after the experiment in all three groups, and to compare the latencies of VEPs recorded before training with those recorded after training. MAIN OUTCOME MEASURES: Comparison of the changes in latencies of VEPs before and after 8 weeks of tennis training. RESULTS: All 45 subjects finished the test and datas from all were included in the statistical analysis. There were no significant differences among all the three groups before tennis training, but the female subjects in each group showed significantly shorter N75 latencies than male subjects of the same group (P 〈 0.05). Comparing the latencies of VEPs after training with those recorded before training, the N75, P100 and N145 latencies were all found to be significantly shorter than before training in the tennis group (P 〈 0.05), but the N75, P100 and N145 latencies were unaffected in the two non-tennis groups (P 〉 0.05); some latencies were even significantly longer than the before-training values. CONCLUSION: Special tennis training for 8 weeks can make the subjects' VEP latencies significantly shorter. Thus, VEP latencies can change with tennis training.展开更多
Objective To study direct cortical electrical stimulation technique for the recording of motor evoked potentials under general anesthesia in central sulcus lesions. Methods The largest N20-P25 response was recorded fr...Objective To study direct cortical electrical stimulation technique for the recording of motor evoked potentials under general anesthesia in central sulcus lesions. Methods The largest N20-P25 response was recorded from postcentral gyrus by intraoperative monitoring of cortical motor evoked potentials in 10 patients with intracranial lesions near or in the central area. The muscles of upper extremity in all patients were activated by delivering stimulus to cortical areas continuously. Moving the cortical electrodes forward, the largest P20-N25 response, SEP phase reversal,was obtained as a motor center stimulus. In this site of cortex, a short train stimulation elicited reproducible muscle action potentials that could be observed from the oscilloscope without averaging.Results MEPs can be recorded, pre-and post-operatively, without motor deficits of upper limbs in all patients.Conclusion This technique seems to be preferable for intraoperative localization of motor evoked potentials in central sulcus lesions under total intravenous anesthesia.展开更多
Summary: Twenty-seven in-patients with hemiplegia following brain injury were studied by using upper extremity median nerve somatosensory evoked patentials (SVEP), Brunnstrom assessment in hemiplegic hand and assessme...Summary: Twenty-seven in-patients with hemiplegia following brain injury were studied by using upper extremity median nerve somatosensory evoked patentials (SVEP), Brunnstrom assessment in hemiplegic hand and assessment of the patients' activities of daily lioing (ADL) (Barthel index). The upper extremity median nerve SEP on the affected and normal sides was determined. By using Kovindha standard, upper extremity median nerve SEP was graded in accordance with N20. The correlation between the differences of SEP N20 amplitude and the latencies on the both sides and the Barthel index scores was analyzed. A Spearman correlation analysis was made between the median nerve SEP N20 grades and Brunnstrom stages in hand or ADL on the affected side. The results showed that upper extremity median nerve SEP grades were positively correlated with those of the Brunnstrom stages in hand (r 1=0.6925, P 1<0.01). The correlation coefficient between SEP N20 grades and patients' ADL grades was r 2=0.5015, P 2<0 01. It was concluded that upper extremity median nerve SEP could be used as a sensitive electrophysiological predictor to clinically assess hemiplegic hand function. SEP N20 might play a role in predicting the ADL of the patients with hemiplegia to some extent, but could not be used as a sensitive predictor to directly observe and predict the ADL of the patients.展开更多
Sensory abnormalities are common in individuals with autism spectrum disorders (ASD) but are often difficult to assess using standard behavioral methods. Evoked potentials provide objective, non-invasive electrophysio...Sensory abnormalities are common in individuals with autism spectrum disorders (ASD) but are often difficult to assess using standard behavioral methods. Evoked potentials provide objective, non-invasive electrophysiological measures of neural sensory processing that could be useful for clinical and investigative studies of individuals with low-functioning autism who are unable to perform behavioral testing. Despite increased use, the reliability of sensory evoked potentials has not been established for individuals with low-functioning autism. Establishing reliability is important for validating the utility of sensory evoked potentials. In this study, we explored the feasibility of assessing the test-retest reliability of sensory evoked potentials using repeat recordings, acquired over 2.5- and 6-month intervals, from a minimally verbal adult with low-functioning autism. Repeat auditory and visual evoked potential recordings showed high test-retest reliability, with cross-correlation coefficients ≥ 0.80. This case demonstrates the feasibility of establishing test-retest reliability for individuals with low-functioning autism and supports the utility of sensory evoked potentials in clinical and investigative ASD studies.展开更多
Objective: To evaluate the diagnostic and prognostic values in patients with delayed encephalopathy after acute carbon monoxide poisoning. Methods: The tibial nerve somatosensory evoked potentials (SEPs), vision e...Objective: To evaluate the diagnostic and prognostic values in patients with delayed encephalopathy after acute carbon monoxide poisoning. Methods: The tibial nerve somatosensory evoked potentials (SEPs), vision evoked potentials (VEPs), and brain stem audition evoked potentials(BAEPs) were performed in 32 healthy adults and 43 patients with delayed encephalopathy after acute carbon monoxide poisoning. Results: This paper indicated abnormalities of tibial nerve SEPs in 31 patients (31/43, 72.1%), VEPs in 17 patients (17/28, 60.7%), and BAEPs in 14, patients (14/43, 32.6%). These results showed that the greatest diagnostic value was SEPs, followed by VEPs and, BAEPs with the lowest sensitivity. Conclusion: Multimodality evoked potentials (EPs) can be used for evaluating the diagnostic and prognostic values in cases of delayed encephalopathy after acute carbon monoxide poisoning.展开更多
BACKGROUND: The wave form, latency and wave amplitude of visual evoked potentials (VEP) are obviously affected by the stimulative parameters, physiological status of the subjects and anesthetics, thus there are greate...BACKGROUND: The wave form, latency and wave amplitude of visual evoked potentials (VEP) are obviously affected by the stimulative parameters, physiological status of the subjects and anesthetics, thus there are greater normal variations and individual differences. The features of flash VEP (F-VEP) are to be observed. OBJECTIVE: To observe and compare the differences of F-VEP latencies and wave amplitudes between eyes in rabbits, and investigate the correlation with sex and the side of eyes. DESIGN: A comparative animal experiment. SETTING: Department of Neurosurgery, General Hospital of Chinese PLA. MATERIALS: The experiment was carried out in the neurophysiological laboratory of the Institute of Neurosciences, General Hospital of Chinese PLA from September 2004 to February 2005. Thirty big-ear rabbits of clean degree, 15 males and 15 females, weighing 2.0-2.5 kg, were provided by the animal center of the General Hospital of Chinese PLA. METHODS: Viking-IV perioperative monitor and flash stimulator for special use were applied. The rabbits were anesthetized with intramuscular injection of compound ketamine. The recording electrode was placed at 3 mm anterior to exoccipital tuberosity (onion, Oz), and the reference electrode was placed at the ear edge of the same side. The stimulative frequency was 1.9 Hz, and the amplifier was 50 μV; The range of wave filter was 5 Hz for high pass and 100 Hz for low pass; The average overlapping was 200 times, and the analytical time was 250 ms. MAIN OUTCOME MEASURES: Comparison of F-VEP wave forms; F-VEP latencies and wave amplitudes. RESULTS: All the 30 rabbits were involved in the analysis of results. ① Comparison of F-VEP wave forms in rabbits: The F-VEP waves mainly manifested as positive-negative-positive (PNP). The F-VEP manifestations to light stimulations were extremely similar between left and right eyes, and the wave amplitudes of both eyes were obviously increased. ② Determinations of F-VEP latencies and wave amplitudes: There were no significant differences in the latencies and wave amplitudes of F-VEP between the two groups (P > 0.05), the latencies of P1, N1 and P2 waves of left eye were (32.59±2.01), (43.85±4.35) and (66.20±8.13) ms, respectively, and the wave amplitudes of P1, N1 and P2 waves of left eye were (16.45±10.22), (7.93±3.56) and (17.62±8.18) μV. F-VEP latencies were stable with small changes, whereas amplitudes had greater changes. CONCLUSION: ① The latency and wave amplitudes F-VEP were stable with good repetition. ② The latencies and wave amplitudes had no significant differences between males and females, as well as between left and right eyes. Further investigation should be undertaken on the animal and clinical field.展开更多
Introduction: Many women think about reduction mammaplasty for different reasons. The effect of surgery on the beast sensibility is one of the greatest concerns after reconstructive reductive breast surgery through it...Introduction: Many women think about reduction mammaplasty for different reasons. The effect of surgery on the beast sensibility is one of the greatest concerns after reconstructive reductive breast surgery through its affect on patient’s social life and psychological health. The dermatomal somatosensory evoked potential (D-SEP) is a new method to quantitatively evaluate breast sensibility. Patients and Methods: Twenty-five women enrolled in this study presenting with breast enlargement, underwent mammary reduction by using the inferior pyramidal breast reduction technique using the same operative technique described by Robbins with some modifications. All D-SEP amplitudes and latencies were calculated preoperatively and then were reassessed six and twelve months post-surgery in each breast. Result: The results revealed that there is a significant difference in the D-SEP latency pre- and post-operatively. The statistically significant decrease in latency and the breast size demonstrated indicates that the sensibility improved after breast reduction surgery both at six and twelve months. There is also a significant increase in the D-SEP amplitude pre- and post-operatively. The negative and statistically significant increase in amplitude with the decrease in breast size demonstrated indicates that the sensibility improved after breast reduction surgery both at six and twelve months. Conclusion: This study concluded that breast sensibility will improve after breast reduction as indicated by significant reduction of D-SEP latencies and increase of its amplitudes. Our results confirm an inverse relationship between breast size and sensibility, with improvement in sensibility after breast reduction.展开更多
Objective Evaluate the sensitivity and reliability of visual evoked potential to flash (F-VEP) in detecting bilirubin neurotoxicity and approach the risk parameters of bilirubin neurotoxicity in hyper-bilirubinemia ne...Objective Evaluate the sensitivity and reliability of visual evoked potential to flash (F-VEP) in detecting bilirubin neurotoxicity and approach the risk parameters of bilirubin neurotoxicity in hyper-bilirubinemia newborns. Methods Based on the successful establishment of animal models for acute bilirubin encephalopathy by intraperitoneal infusion of bilirubin with a dosage of 100~200μg/g body weight to 1-week-old guinea pigs, the F-VEP was recorded in animal models and human neonates with hyperbilirubinemia, and the sensitivity and reliability of F-VEP in detecting bilirubin neurotoxicity were evaluated. Results F-VEP features and its P1 latency significantly correlated to brain adenosine triphosphate (ATP) level, neurobeha-vioral and neuropathological changes in experimental bilirubin encephalopathy; neonates with hyperbiliru-binemia showed significant F-VEP changes characterized by absence of P1 or P1 latency prolonged in 1~7-day-old newborns, especially when the jaundice was caused by immun oincompatibility and infectious diseases. Conclusion F-VEP would be a good discriminator for bilirubin neurotoxicity, and can become a promising technique in monitoring bilirubin encephalopathy.展开更多
Objective To investigate the status of evoked potentials in obsessive-compulsive disorder(OCD). Methods Evoked potentials P300, auditory brainstem response (ABR) and visual evoked potential ( VEP) were recorded from 3...Objective To investigate the status of evoked potentials in obsessive-compulsive disorder(OCD). Methods Evoked potentials P300, auditory brainstem response (ABR) and visual evoked potential ( VEP) were recorded from 35 OCD patients and 28 normal controls (NC) with a Nicolet Spirit Instrument. 23 of the OCD patients were followed up after 5 months with the same markers. Results Compared with NC, OCD patients showed decreased P3 of P300 amplitude (OCD group 3. 5 ±1. 6μv vs. NC group 5.9 ±2. 1μv, P <0. 01), delayed V latency (6.4±0. 4ms vs. 5. 5 ±0. 3ms, P <0. 01) and increased V amplitude(0. 35±0. 1μv vs. 0. 16 ±0.09μv, P <0. 05) of ABR and delayed P2 of VEP latency (199±39ms vs. 183±28ms, P <0. 05). The follow-up measures of evoked potentials suggested that decreased P3 of P300 amplitude and delayed P2 of VEP latency might be state markers of OCD, while decreased V amplitude and delayed V of ABR latency might be trait markers of OCD. Conclusion The changes of P300 and VEP are related to clinical status of OCD patients, while the association between ABR and OCD symptoms need to be further investigated.展开更多
We observed the steady-state visually evoked potential(SSVEP) from a healthy subject using a compact quad-channel potassium spin exchange relaxation-free(SERF) optically pumped magnetometer(OPM). To this end, 30 s of ...We observed the steady-state visually evoked potential(SSVEP) from a healthy subject using a compact quad-channel potassium spin exchange relaxation-free(SERF) optically pumped magnetometer(OPM). To this end, 30 s of data were collected, and SSVEP-related magnetic responses with signal intensity ranging from 150 fT to 300 f T were observed for all four channels. The corresponding signal to noise ratio(SNR) was in the range of 3.5–5.5. We then used different channels to operate the sensor as a gradiometer. In the specific case of detecting SSVEP, we noticed that the short channel separation distance led to a strongly diminished gradiometer signal. Although not optimal for the case of SSVEP detection, this set-up can prove to be highly useful for other magnetoencephalography(MEG) paradigms that require good noise cancellation.Considering its compactness, low cost, and good performance, the K-SERF sensor has great potential for biomagnetic field measurements and brain-computer interfaces(BCI).展开更多
Aim: Extensive neurophysiological investigations were carried out in 100 healthy subjects and 84 patients with penileerectile dysfunction. Methods: Following examinations were performed, spinal and scalp somatosensory...Aim: Extensive neurophysiological investigations were carried out in 100 healthy subjects and 84 patients with penileerectile dysfunction. Methods: Following examinations were performed, spinal and scalp somatosensory evoked poten-tials (SEPs) to stimulation of the dorsal nerve of penis, motor evoked potentials (MEPs) from bulbocavernosus (BC) inresponse to scalp and spinal root stimulation, and measurement of sacral reflex latency (SRL) from anal sphincter (AS).Results: In the healthy subjects, the mean sensory total conduction time (sensory TCT), as measured at the peak of thescalp P1 (P40) wave was 39.73 ms. The mean sensory central conduction time (sensory CCT = spinal-to-scalp conductiontime) was 28.98 ms. The mean peripheral conduction time (PCP) was 9.40 ins. Transcranial brain stimulation was per-formed by using a magnetic stimulator during voluntary contraction of the examined muscle. Spinal root stimulation wasperformed at rest. Motor total conduction time (motor TCT) to BC muscles was 20.48 ms. Motor central conductiontime (motor CCT) to sacral cord segments controlling BC muscles was 14.42 ms at rest. The mean SRL was 35.13 ms.Conclusion: Combined or isolated abnormalities of SEPs, MEPs, and SRL were found in patients with erectile dysfunc-tion. (Asian J Androl 1999 Sep; 1 : 145 - 150)展开更多
Visual evoked potentials (VEPs) are a series of signals about visual occipital cortex in response to visual stimuli and can be used as one of ob-jective non-invasive neuro-physiological pa-rameters to reflect the visu...Visual evoked potentials (VEPs) are a series of signals about visual occipital cortex in response to visual stimuli and can be used as one of ob-jective non-invasive neuro-physiological pa-rameters to reflect the visual organs and central visual pathway’s functional integrity. Previous studies have shown that acute and chronic ex-ercise could affect VEPs independent from body temperature and other physiological parameters. VEPs may well be used as neuro-physiological criteria in defining the performances of the ath-letes. Different sports training have different effects on VEPs, but the results are not consis-tent. P100 latency is the representative compo-nent of VEPs and it is of high, steady amplitude and of slight intra- and inter-individual variabil-ity so that the index is most commonly used. The purpose of this study was to investigate the specificity and sensitivity of P100 latency to dif-ferent physical activities. The neural electricity device of NDI-200 was used to measure the pattern reversal VEPs of all subjects, including the values of the resting state before and after different events exercise. Different events exer-cise contained an aerobic cycloergometric ex-ercise (7 subjects were conducted to a Bruce Graded Exercise Test on the Monark Ergomedic 839E cycloergometer, THR (target heart rate) = 85% HRmax, 3 times/week, about 10 minutes once time, 6 weeks), tennis training (16 volun-teers, 2 hours/day, 3 days/week, 8 weeks), aerobic Latin exercise (7 subjects, 1 hour/day, 3 days/week, 6 weeks) and the Baduanjin of Health Qigong training (6 subjects, 1 hour/day, 3 days/week, 6 weeks). The VEPs recordings of the control groups obtained synchronized with the experimental groups. SPSS 11.5 for win-dows was used for statistical analysis. A level of P﹤0.05 was accepted as statistically significant. The VEPs P100 latency of post-exercise of all experimental groups except Baduanjin group became shorter significantly compared with those of pre-exercise (P﹤0.05). No significant difference was found between pre-and post- exercise for the control groups. This study showed that exercise could shorten the P100 la-tency significantly. Moreover, it also indicated that VEPs were sensitive to exercise to a certain extent. We concluded that VEPs might well be used as neuro-physiological criteria in defining the performances of the athletes. It was found that the VEPs P100 latency became shorter after most training programs;furthermore, it demon-strated that P100 latency of VEPs had little specificity to different events.展开更多
The combined use of motor .yoked pot'ntlais (MEPs) with F way, recording was cornpared with somatesemory evoked potentials (SEPs) in order to evaluate the clinical value or MEPs incervical spondylotic myelopathy. ...The combined use of motor .yoked pot'ntlais (MEPs) with F way, recording was cornpared with somatesemory evoked potentials (SEPs) in order to evaluate the clinical value or MEPs incervical spondylotic myelopathy. Magnetic stimulation of motor cortex with F wave recording was used assess central motor conduction. time, (CMCT). and central somatoseusory conduction time(CSCT)was evaluated by SEPs in 20 pailents surffring from myeloP8thy of cervical spondylosis. Theresults were comapared with 20 control subjects. The results showed that CMCT of Patients was obviously prolonged then that of contral subjects, the sbnormal rate was 80% which was higher than70K of SEPs slid that the prolongation or CMCT had a good correlation with the severe degree ofmyelopathy. The Painless and noninvasive .magnetic stimulation of PEPs could figure out the compressed degree of motor descending pathway and was. useful technique for diagnosis of cervicalspondylotic myelopathy.展开更多
Objective:To evaluate the changes of brainstem auditory evoked potential (BAEP) in patients with delayed encephalopathy after acute carbon monoxide poisoning. Methods: BAEPs were performed in 32 controls and 40 patien...Objective:To evaluate the changes of brainstem auditory evoked potential (BAEP) in patients with delayed encephalopathy after acute carbon monoxide poisoning. Methods: BAEPs were performed in 32 controls and 40 patients. Wave Ⅰ , Ⅱ , Ⅲ ,Ⅳ, Ⅴ latencies and Ⅰ-Ⅲ , Ⅲ-Ⅴ , Ⅰ-Ⅴ interpeak latencies were measured, respectively. Results: Abnormalities of BAEPs in 13 patients (13/40, 32 %). Among the13 abnormal BAEPs, 3 displayed prolongation of latency to waves in one side, no potential in another side; 5 displayed a similar abnormality which was bilateral prolongation of latency to waves ;and another 5 displayed unilateral latency delay. Compared wave Ⅰ , Ⅱ , Ⅲ , Ⅳ, Ⅴ latencies and Ⅰ-Ⅲ , Ⅲ-Ⅴ , Ⅰ-Ⅴ interpeak latencies in the patients and the controls, there were no significant differences (P>0.05). Conclusion: BAEPs can be used for evaluating the diagnostic and prognostic values in the cases of delayed encephalopathy after acute carbon monoxide poisoning.展开更多
BACKGROUND: Previous experiments have demonstrated that brainstem auditory evoked potential is affected by exercise, exercise duration, and frequency. OBJECTIVE: Comparing the brainstem auditory evoked potential of ...BACKGROUND: Previous experiments have demonstrated that brainstem auditory evoked potential is affected by exercise, exercise duration, and frequency. OBJECTIVE: Comparing the brainstem auditory evoked potential of students studying folk dance to students studying other subjects. DESIGN: Observational contrast study. SETTING: Physical Education College, Shandong Normal University PARTICIPANTS: Fifty-five female students were enrolled at Shandong Normal University between September and December in 2005, including 21 students that studied folk dance and 34 students that studied other subjects. The age of the folk dance students averaged (19 ± 1) years and dance training length was (6.0 ± 1.5) years. The students that studied other subjects had never taken part in dance training or other physical training, and their age averaged (22 ± 1) years, body height averaged (162 ± 5) cm, body mass averaged (51 ± 6) kg. All subjects had no prior ear disease or history of other neurological disorders. All students provided informed consent for the experimental project. METHODS: The neural electricity tester, NDI-200 (Shanghai Poseidon Medical Electronic Instrument Factory) was used to examine and record Brainstem Auditory Evoked Potential values of the subjects during silence, as well as to transversally analyze the Brainstem Auditory Evoked Potential values. The electrode positions were cleaned and degreased with soapy water, followed by ethanol. The selected bipolar electrodes were situated on the head: recording electrodes were placed at the Baihui acupoint, and the reference electrode was placed at the mastoid of the measured ear, with grounding electrodes in the center of the forehead. Brainstem Auditory Evoked Potential values were elicited by monaural stimulation of a "click" though an earphone; the other ear was sheltered by the white noise. The click intensity was 102 db, the stimulation frequency was 30 Hz, the bandpass filters were 1 000-3 000 Hz, the sensitivity was 5 ta V, and a total of 2 000 sweeps were averaged. Waveform identification and analysis: various components of the Brainstem Auditory Evoked Potential values were identified, and the peak latencies and peak-peak values were analyzed. MAIN OUTCOME MEASURES: Latency of Ⅰ , Ⅱ, Ⅲ, Ⅳ, Ⅴ and Peak-Peak Value of Ⅰ, Ⅲ, Ⅴwere measured. RESULTS: Fifty-five subjects were enrolled in the final analysis, without any loss. Compared to the students who studied other subjects ① Ⅰ -Ⅴ peak latencies (PL): Ⅳ PL of the right ear of the folk dance students was obviously longer (P 〈 0.05); ② Ⅰ, Ⅲ, V peak-peak values:Ⅰ peak-peak values of the right ear were obviously higher (P 〈 0.05). CONCUSION: ① PL of the right ear of the folk dance students was obviously longer, which indicates that dancing results in a stronger sensibility to auditory stimuli. ②. Peak-peak values were obviously higher, which indicates that long-term exercise enhances the music senses and synchrony of auditory nerve impulses.展开更多
文摘Abnormal SEP reflects dysfunction of the medial lemniscus and posterior cervical cord. These structures are likely to be affected in Chiari malformation. Therefore, SEP abnormalities may provide valuable information in patients with CM. However, the consistency of SEP abnormality or normality with the damage is a matter of research. Knowing whether median nerve somatosensory evoked potential (SEP) is useful in revealing subclinical damage in patients with Chiari malformation is important in the treatment and follow-up plan of the disease. The aim of this study was to investigate the relationship between median nerve SEP values and the severity of cerebellar ectopia in patients with Chiari type 1 malformation. Median nerve SEP values were obtained from 30 healthy individuals and 146 individuals with Chiari malformation. The cerebellar ectopia degree and McRae line length were measured. SEP values were not significantly different between groups. The McRae line was found to be significantly shorter in the control group than in the Chiari malformation group (p = 0.031). There was no correlation between the degree of cerebellar ectopia and the length of the McRae line (r = 0.002, p = 0.979). Neither cerebellar ectopy degree nor McRae line length had a relationship with SEP values (r = -0.153, p = 0.066;r = -0.056, p = 0.500, respectively). There was no difference in cerebellar ectopy degree or SEP values between the groups with cerebellar ectopy with and without a syrinx (p = 0.899;p = 0.080, respectively). Likewise, McRae line length was not found to be related to the presence of a syrinx (p = 0.139). Median nerve SEP examination was not beneficial for diagnosing asymptomatic-oligosymptomatic Chiari malformation as a subclinical injury, whether accompanied by syringomyelia or not.
基金supported by the National Natural Science Foundation of China,No.81101370,81101399,81272018the Natural Science Foundation of Jiangsu Province in China,No.BK2011303+2 种基金Jiangsu Province Science and Technology Support Program(Social Development)in China,No.BE2011672University Natural Science Research Foundation of Jiangsu Province for Higher Education,No.12KJB320008College Graduate Research and Innovation Plan of Jiangsu Province in China,No.CXZZ11_0126
文摘It remains unclear whether spinal cord ischemia-reperfusion injury caused by ischemia and other non-mechanical factors can be monitored by somatosensory evoked potentials. Therefore, we monitored spinal cord ischemia-reperfusion injury in rabbits using somatosensory evoked potential detection technology. The results showed that the somatosensory evoked potential latency was significantly prolonged and the amplitude significantly reduced until it disappeared during the period of spinal cord ischemia. After reperfusion for 30-180 minutes, the amplitude and latency began to gradually recover; at 360 minutes of reperfusion, the latency showed no significant difference compared with the pre-ischemic value, while the somatosensory evoked potential amplitude in- creased, and severe hindlimb motor dysfunctions were detected. Experimental findings suggest that changes in somatosensory evoked potentia~ ~atency can reflect the degree of spinat cord ischemic injury, while the amplitude variations are indicators of the late spinal cord reperfusion injury, which provide evidence for the assessment of limb motor function and avoid iatrogenic spinal cord injury.
基金Supported by the Research Foundation of Akdeniz University, Turkey
文摘AIM: To evaluate the effect of sodium tungstate on visual evoked potentials(VEPs) in diabetic rats.· METHODS: Wistar rats were randomly divided into three groups as normal control, diabetic control and diabetic rats treated with sodium tungstate. Diabetes was induced by single intraperitoneal injection of streptozotocin(50 mg/kg). Sodium tungstate [40 mg/(kg·d)]was administered for 12 wk and then VEPs were recorded.Additionally, thiobarbituric acid reactive substance(TBARS) levels were measured in brain tissues.·RESULTS: The latencies of P1, N1, P2, N2 and P3 waves were significantly prolonged in diabetic rats compared with control group. Diabetes mellitus caused an increase in the lipid peroxidation process that was accompanied by changes in VEPs. However, prolonged latencies of VEPs for all components returned to control levels in sodium tungstate-treated group. The treatment of sodium tungstate significantly decreased brain TBARS levels and depleted the prolonged latencies of VEP components compared with diabetic control group.· CONCLUSION: Sodium tungstate shows protective effects on visual pathway in diabetic rats, and it can be worthy of further study for potential use.
文摘AIM: To evaluate the use of short-duration transient visual evoked potentials(VEP) and color reflectivity discretization analysis(CORDA) in glaucomatous eyes,eyes suspected of having glaucoma,and healthy eyes.METHODS: The study included 136 eyes from 136 subjects: 49 eyes with glaucoma,45 glaucoma suspect eyes,and 42 healthy eyes.Subjects underwent Humphrey visual field(VF) testing,VEP testing,as well as peripapillary retinal nerve fiber layer optical coherence tomography imaging studies with post-acquisition CORDA applied.Statistical analysis was performed using means and ranges,ANOVA,post-hoc comparisons using Turkey's adjustment,Fisher's Exact test,area under the curve,and Spearman correlation coefficients.RESULTS: Parameters from VEP and CORDA correlated significantly with VF mean deviation(MD)(P〈0.05).In distinguishing glaucomatous eyes from controls,VEP demonstrated area under the curve(AUC) values of 0.64-0.75 for amplitude and 0.67-0.81 for latency.The CORDA HR1 parameter was highly discriminative for glaucomatous eyes vs controls(AUC=0.94).CONCLUSION: Significant correlations are found between MD and parameters of short-duration transient VEP and CORDA,diagnostic modalities which warrant further consideration in identifying glaucoma characteristics.
文摘Objective: Optimization of combining electroencephalography (EEG), short latency somatosensory evoked potentials (SLSEP) and transcranial Doppler (TCD) techniques to diagnose brain death. Methods: One hundred and eleven patients (69 males, 42 females) from the major hospitals of Zhejiang Province were examined with portable EEG, SLSEP and TCD devices. Re-examinations occurred ≤12 h later. Results: The first examination revealed that the combination of SLSEP and EEG led to more sensitive diagnoses than the combination of SLSEP and TCD. Re-examination confirmed this and also revealed that the combination of TCD and EEG was the most sensitive. Conclusion: The results show that using multiple techniques to diagnose brain death is superior to using single method, and that the combination of SLSEP and EEG is better than other combinations.
文摘BACKGROUND: Some previous studies have shown that exercise is an important factor that affects the latencies of visual-evoked potentials (VEPs). OBJECTIVE: To investigate the effects of spending a period of time undergoing tennis training on the latencies of VEPs by comparing the latencies of VEPs before tennis training with those after 8 weeks of tennis training. DESIGN, TIME AND SETTING: The non-randomly concurrent controlled experiment was performed in the Department of Human Movement Sciences, Physical Education College, Shandong Normal University from April to June 2007. PARTICIPANTS: In total, 45 healthy volunteers from Shandong Normal University were selected as subjects, including 31 students majoring in physical education (11 males and 5 females participated in the tennis training plan for 8 weeks), and 14 students from other subjects. Informed consent was obtained. According to whether they were majoring in physical education or not, and whether or not they took part in tennis training, the students were divided into 3 groups: a tennis group of physical education students (n = 16) a non-tennis group of physical education students (n =15) and a non-tennis group of non-physical education students (n = 14). METHODS: The subjects in the tennis group took part in a regular tennis training plan of 2 hours a day and 3 days per week, for 8 weeks, while the subjects in two non-tennis groups were not in the tennis training plan The NDI-200 neural electricity tester (Shanghai Haishen Medical Electronic Instrument Co., Ltd.) was used to measure VEPs before and after the experiment in all three groups, and to compare the latencies of VEPs recorded before training with those recorded after training. MAIN OUTCOME MEASURES: Comparison of the changes in latencies of VEPs before and after 8 weeks of tennis training. RESULTS: All 45 subjects finished the test and datas from all were included in the statistical analysis. There were no significant differences among all the three groups before tennis training, but the female subjects in each group showed significantly shorter N75 latencies than male subjects of the same group (P 〈 0.05). Comparing the latencies of VEPs after training with those recorded before training, the N75, P100 and N145 latencies were all found to be significantly shorter than before training in the tennis group (P 〈 0.05), but the N75, P100 and N145 latencies were unaffected in the two non-tennis groups (P 〉 0.05); some latencies were even significantly longer than the before-training values. CONCLUSION: Special tennis training for 8 weeks can make the subjects' VEP latencies significantly shorter. Thus, VEP latencies can change with tennis training.
基金Science and Technology Committee of Shanghai, China (024119019).
文摘Objective To study direct cortical electrical stimulation technique for the recording of motor evoked potentials under general anesthesia in central sulcus lesions. Methods The largest N20-P25 response was recorded from postcentral gyrus by intraoperative monitoring of cortical motor evoked potentials in 10 patients with intracranial lesions near or in the central area. The muscles of upper extremity in all patients were activated by delivering stimulus to cortical areas continuously. Moving the cortical electrodes forward, the largest P20-N25 response, SEP phase reversal,was obtained as a motor center stimulus. In this site of cortex, a short train stimulation elicited reproducible muscle action potentials that could be observed from the oscilloscope without averaging.Results MEPs can be recorded, pre-and post-operatively, without motor deficits of upper limbs in all patients.Conclusion This technique seems to be preferable for intraoperative localization of motor evoked potentials in central sulcus lesions under total intravenous anesthesia.
文摘Summary: Twenty-seven in-patients with hemiplegia following brain injury were studied by using upper extremity median nerve somatosensory evoked patentials (SVEP), Brunnstrom assessment in hemiplegic hand and assessment of the patients' activities of daily lioing (ADL) (Barthel index). The upper extremity median nerve SEP on the affected and normal sides was determined. By using Kovindha standard, upper extremity median nerve SEP was graded in accordance with N20. The correlation between the differences of SEP N20 amplitude and the latencies on the both sides and the Barthel index scores was analyzed. A Spearman correlation analysis was made between the median nerve SEP N20 grades and Brunnstrom stages in hand or ADL on the affected side. The results showed that upper extremity median nerve SEP grades were positively correlated with those of the Brunnstrom stages in hand (r 1=0.6925, P 1<0.01). The correlation coefficient between SEP N20 grades and patients' ADL grades was r 2=0.5015, P 2<0 01. It was concluded that upper extremity median nerve SEP could be used as a sensitive electrophysiological predictor to clinically assess hemiplegic hand function. SEP N20 might play a role in predicting the ADL of the patients with hemiplegia to some extent, but could not be used as a sensitive predictor to directly observe and predict the ADL of the patients.
文摘Sensory abnormalities are common in individuals with autism spectrum disorders (ASD) but are often difficult to assess using standard behavioral methods. Evoked potentials provide objective, non-invasive electrophysiological measures of neural sensory processing that could be useful for clinical and investigative studies of individuals with low-functioning autism who are unable to perform behavioral testing. Despite increased use, the reliability of sensory evoked potentials has not been established for individuals with low-functioning autism. Establishing reliability is important for validating the utility of sensory evoked potentials. In this study, we explored the feasibility of assessing the test-retest reliability of sensory evoked potentials using repeat recordings, acquired over 2.5- and 6-month intervals, from a minimally verbal adult with low-functioning autism. Repeat auditory and visual evoked potential recordings showed high test-retest reliability, with cross-correlation coefficients ≥ 0.80. This case demonstrates the feasibility of establishing test-retest reliability for individuals with low-functioning autism and supports the utility of sensory evoked potentials in clinical and investigative ASD studies.
基金The Department of Education in Henan (2000320042)
文摘Objective: To evaluate the diagnostic and prognostic values in patients with delayed encephalopathy after acute carbon monoxide poisoning. Methods: The tibial nerve somatosensory evoked potentials (SEPs), vision evoked potentials (VEPs), and brain stem audition evoked potentials(BAEPs) were performed in 32 healthy adults and 43 patients with delayed encephalopathy after acute carbon monoxide poisoning. Results: This paper indicated abnormalities of tibial nerve SEPs in 31 patients (31/43, 72.1%), VEPs in 17 patients (17/28, 60.7%), and BAEPs in 14, patients (14/43, 32.6%). These results showed that the greatest diagnostic value was SEPs, followed by VEPs and, BAEPs with the lowest sensitivity. Conclusion: Multimodality evoked potentials (EPs) can be used for evaluating the diagnostic and prognostic values in cases of delayed encephalopathy after acute carbon monoxide poisoning.
文摘BACKGROUND: The wave form, latency and wave amplitude of visual evoked potentials (VEP) are obviously affected by the stimulative parameters, physiological status of the subjects and anesthetics, thus there are greater normal variations and individual differences. The features of flash VEP (F-VEP) are to be observed. OBJECTIVE: To observe and compare the differences of F-VEP latencies and wave amplitudes between eyes in rabbits, and investigate the correlation with sex and the side of eyes. DESIGN: A comparative animal experiment. SETTING: Department of Neurosurgery, General Hospital of Chinese PLA. MATERIALS: The experiment was carried out in the neurophysiological laboratory of the Institute of Neurosciences, General Hospital of Chinese PLA from September 2004 to February 2005. Thirty big-ear rabbits of clean degree, 15 males and 15 females, weighing 2.0-2.5 kg, were provided by the animal center of the General Hospital of Chinese PLA. METHODS: Viking-IV perioperative monitor and flash stimulator for special use were applied. The rabbits were anesthetized with intramuscular injection of compound ketamine. The recording electrode was placed at 3 mm anterior to exoccipital tuberosity (onion, Oz), and the reference electrode was placed at the ear edge of the same side. The stimulative frequency was 1.9 Hz, and the amplifier was 50 μV; The range of wave filter was 5 Hz for high pass and 100 Hz for low pass; The average overlapping was 200 times, and the analytical time was 250 ms. MAIN OUTCOME MEASURES: Comparison of F-VEP wave forms; F-VEP latencies and wave amplitudes. RESULTS: All the 30 rabbits were involved in the analysis of results. ① Comparison of F-VEP wave forms in rabbits: The F-VEP waves mainly manifested as positive-negative-positive (PNP). The F-VEP manifestations to light stimulations were extremely similar between left and right eyes, and the wave amplitudes of both eyes were obviously increased. ② Determinations of F-VEP latencies and wave amplitudes: There were no significant differences in the latencies and wave amplitudes of F-VEP between the two groups (P > 0.05), the latencies of P1, N1 and P2 waves of left eye were (32.59±2.01), (43.85±4.35) and (66.20±8.13) ms, respectively, and the wave amplitudes of P1, N1 and P2 waves of left eye were (16.45±10.22), (7.93±3.56) and (17.62±8.18) μV. F-VEP latencies were stable with small changes, whereas amplitudes had greater changes. CONCLUSION: ① The latency and wave amplitudes F-VEP were stable with good repetition. ② The latencies and wave amplitudes had no significant differences between males and females, as well as between left and right eyes. Further investigation should be undertaken on the animal and clinical field.
文摘Introduction: Many women think about reduction mammaplasty for different reasons. The effect of surgery on the beast sensibility is one of the greatest concerns after reconstructive reductive breast surgery through its affect on patient’s social life and psychological health. The dermatomal somatosensory evoked potential (D-SEP) is a new method to quantitatively evaluate breast sensibility. Patients and Methods: Twenty-five women enrolled in this study presenting with breast enlargement, underwent mammary reduction by using the inferior pyramidal breast reduction technique using the same operative technique described by Robbins with some modifications. All D-SEP amplitudes and latencies were calculated preoperatively and then were reassessed six and twelve months post-surgery in each breast. Result: The results revealed that there is a significant difference in the D-SEP latency pre- and post-operatively. The statistically significant decrease in latency and the breast size demonstrated indicates that the sensibility improved after breast reduction surgery both at six and twelve months. There is also a significant increase in the D-SEP amplitude pre- and post-operatively. The negative and statistically significant increase in amplitude with the decrease in breast size demonstrated indicates that the sensibility improved after breast reduction surgery both at six and twelve months. Conclusion: This study concluded that breast sensibility will improve after breast reduction as indicated by significant reduction of D-SEP latencies and increase of its amplitudes. Our results confirm an inverse relationship between breast size and sensibility, with improvement in sensibility after breast reduction.
文摘Objective Evaluate the sensitivity and reliability of visual evoked potential to flash (F-VEP) in detecting bilirubin neurotoxicity and approach the risk parameters of bilirubin neurotoxicity in hyper-bilirubinemia newborns. Methods Based on the successful establishment of animal models for acute bilirubin encephalopathy by intraperitoneal infusion of bilirubin with a dosage of 100~200μg/g body weight to 1-week-old guinea pigs, the F-VEP was recorded in animal models and human neonates with hyperbilirubinemia, and the sensitivity and reliability of F-VEP in detecting bilirubin neurotoxicity were evaluated. Results F-VEP features and its P1 latency significantly correlated to brain adenosine triphosphate (ATP) level, neurobeha-vioral and neuropathological changes in experimental bilirubin encephalopathy; neonates with hyperbiliru-binemia showed significant F-VEP changes characterized by absence of P1 or P1 latency prolonged in 1~7-day-old newborns, especially when the jaundice was caused by immun oincompatibility and infectious diseases. Conclusion F-VEP would be a good discriminator for bilirubin neurotoxicity, and can become a promising technique in monitoring bilirubin encephalopathy.
基金Supported by the Fund of ' 100 Distinguished Investigator' of Shanghai Sanitary Authorities(97BR030)Fund of Clinical Medicine Center of Shanghai Mental Disorder(ZX02A14).
文摘Objective To investigate the status of evoked potentials in obsessive-compulsive disorder(OCD). Methods Evoked potentials P300, auditory brainstem response (ABR) and visual evoked potential ( VEP) were recorded from 35 OCD patients and 28 normal controls (NC) with a Nicolet Spirit Instrument. 23 of the OCD patients were followed up after 5 months with the same markers. Results Compared with NC, OCD patients showed decreased P3 of P300 amplitude (OCD group 3. 5 ±1. 6μv vs. NC group 5.9 ±2. 1μv, P <0. 01), delayed V latency (6.4±0. 4ms vs. 5. 5 ±0. 3ms, P <0. 01) and increased V amplitude(0. 35±0. 1μv vs. 0. 16 ±0.09μv, P <0. 05) of ABR and delayed P2 of VEP latency (199±39ms vs. 183±28ms, P <0. 05). The follow-up measures of evoked potentials suggested that decreased P3 of P300 amplitude and delayed P2 of VEP latency might be state markers of OCD, while decreased V amplitude and delayed V of ABR latency might be trait markers of OCD. Conclusion The changes of P300 and VEP are related to clinical status of OCD patients, while the association between ABR and OCD symptoms need to be further investigated.
基金Project supported by the National Key Research and Development Program of China(Grant Nos.2016YFA0300600 and 2016YFA0301500)the Strategic Priority Research Program of Chinese Academy of Sciences(Grant Nos.XDB07030000 and XDBS32000000)+1 种基金the National Natural Science Foundation of China(Grant Nos.11474347 and 31730039)the Fund from the Ministry of Science and Technology of China(Grant No.2015CB351701)
文摘We observed the steady-state visually evoked potential(SSVEP) from a healthy subject using a compact quad-channel potassium spin exchange relaxation-free(SERF) optically pumped magnetometer(OPM). To this end, 30 s of data were collected, and SSVEP-related magnetic responses with signal intensity ranging from 150 fT to 300 f T were observed for all four channels. The corresponding signal to noise ratio(SNR) was in the range of 3.5–5.5. We then used different channels to operate the sensor as a gradiometer. In the specific case of detecting SSVEP, we noticed that the short channel separation distance led to a strongly diminished gradiometer signal. Although not optimal for the case of SSVEP detection, this set-up can prove to be highly useful for other magnetoencephalography(MEG) paradigms that require good noise cancellation.Considering its compactness, low cost, and good performance, the K-SERF sensor has great potential for biomagnetic field measurements and brain-computer interfaces(BCI).
文摘Aim: Extensive neurophysiological investigations were carried out in 100 healthy subjects and 84 patients with penileerectile dysfunction. Methods: Following examinations were performed, spinal and scalp somatosensory evoked poten-tials (SEPs) to stimulation of the dorsal nerve of penis, motor evoked potentials (MEPs) from bulbocavernosus (BC) inresponse to scalp and spinal root stimulation, and measurement of sacral reflex latency (SRL) from anal sphincter (AS).Results: In the healthy subjects, the mean sensory total conduction time (sensory TCT), as measured at the peak of thescalp P1 (P40) wave was 39.73 ms. The mean sensory central conduction time (sensory CCT = spinal-to-scalp conductiontime) was 28.98 ms. The mean peripheral conduction time (PCP) was 9.40 ins. Transcranial brain stimulation was per-formed by using a magnetic stimulator during voluntary contraction of the examined muscle. Spinal root stimulation wasperformed at rest. Motor total conduction time (motor TCT) to BC muscles was 20.48 ms. Motor central conductiontime (motor CCT) to sacral cord segments controlling BC muscles was 14.42 ms at rest. The mean SRL was 35.13 ms.Conclusion: Combined or isolated abnormalities of SEPs, MEPs, and SRL were found in patients with erectile dysfunc-tion. (Asian J Androl 1999 Sep; 1 : 145 - 150)
文摘Visual evoked potentials (VEPs) are a series of signals about visual occipital cortex in response to visual stimuli and can be used as one of ob-jective non-invasive neuro-physiological pa-rameters to reflect the visual organs and central visual pathway’s functional integrity. Previous studies have shown that acute and chronic ex-ercise could affect VEPs independent from body temperature and other physiological parameters. VEPs may well be used as neuro-physiological criteria in defining the performances of the ath-letes. Different sports training have different effects on VEPs, but the results are not consis-tent. P100 latency is the representative compo-nent of VEPs and it is of high, steady amplitude and of slight intra- and inter-individual variabil-ity so that the index is most commonly used. The purpose of this study was to investigate the specificity and sensitivity of P100 latency to dif-ferent physical activities. The neural electricity device of NDI-200 was used to measure the pattern reversal VEPs of all subjects, including the values of the resting state before and after different events exercise. Different events exer-cise contained an aerobic cycloergometric ex-ercise (7 subjects were conducted to a Bruce Graded Exercise Test on the Monark Ergomedic 839E cycloergometer, THR (target heart rate) = 85% HRmax, 3 times/week, about 10 minutes once time, 6 weeks), tennis training (16 volun-teers, 2 hours/day, 3 days/week, 8 weeks), aerobic Latin exercise (7 subjects, 1 hour/day, 3 days/week, 6 weeks) and the Baduanjin of Health Qigong training (6 subjects, 1 hour/day, 3 days/week, 6 weeks). The VEPs recordings of the control groups obtained synchronized with the experimental groups. SPSS 11.5 for win-dows was used for statistical analysis. A level of P﹤0.05 was accepted as statistically significant. The VEPs P100 latency of post-exercise of all experimental groups except Baduanjin group became shorter significantly compared with those of pre-exercise (P﹤0.05). No significant difference was found between pre-and post- exercise for the control groups. This study showed that exercise could shorten the P100 la-tency significantly. Moreover, it also indicated that VEPs were sensitive to exercise to a certain extent. We concluded that VEPs might well be used as neuro-physiological criteria in defining the performances of the athletes. It was found that the VEPs P100 latency became shorter after most training programs;furthermore, it demon-strated that P100 latency of VEPs had little specificity to different events.
文摘The combined use of motor .yoked pot'ntlais (MEPs) with F way, recording was cornpared with somatesemory evoked potentials (SEPs) in order to evaluate the clinical value or MEPs incervical spondylotic myelopathy. Magnetic stimulation of motor cortex with F wave recording was used assess central motor conduction. time, (CMCT). and central somatoseusory conduction time(CSCT)was evaluated by SEPs in 20 pailents surffring from myeloP8thy of cervical spondylosis. Theresults were comapared with 20 control subjects. The results showed that CMCT of Patients was obviously prolonged then that of contral subjects, the sbnormal rate was 80% which was higher than70K of SEPs slid that the prolongation or CMCT had a good correlation with the severe degree ofmyelopathy. The Painless and noninvasive .magnetic stimulation of PEPs could figure out the compressed degree of motor descending pathway and was. useful technique for diagnosis of cervicalspondylotic myelopathy.
基金Supported by the Department of Education in Henan (2000320042)
文摘Objective:To evaluate the changes of brainstem auditory evoked potential (BAEP) in patients with delayed encephalopathy after acute carbon monoxide poisoning. Methods: BAEPs were performed in 32 controls and 40 patients. Wave Ⅰ , Ⅱ , Ⅲ ,Ⅳ, Ⅴ latencies and Ⅰ-Ⅲ , Ⅲ-Ⅴ , Ⅰ-Ⅴ interpeak latencies were measured, respectively. Results: Abnormalities of BAEPs in 13 patients (13/40, 32 %). Among the13 abnormal BAEPs, 3 displayed prolongation of latency to waves in one side, no potential in another side; 5 displayed a similar abnormality which was bilateral prolongation of latency to waves ;and another 5 displayed unilateral latency delay. Compared wave Ⅰ , Ⅱ , Ⅲ , Ⅳ, Ⅴ latencies and Ⅰ-Ⅲ , Ⅲ-Ⅴ , Ⅰ-Ⅴ interpeak latencies in the patients and the controls, there were no significant differences (P>0.05). Conclusion: BAEPs can be used for evaluating the diagnostic and prognostic values in the cases of delayed encephalopathy after acute carbon monoxide poisoning.
文摘BACKGROUND: Previous experiments have demonstrated that brainstem auditory evoked potential is affected by exercise, exercise duration, and frequency. OBJECTIVE: Comparing the brainstem auditory evoked potential of students studying folk dance to students studying other subjects. DESIGN: Observational contrast study. SETTING: Physical Education College, Shandong Normal University PARTICIPANTS: Fifty-five female students were enrolled at Shandong Normal University between September and December in 2005, including 21 students that studied folk dance and 34 students that studied other subjects. The age of the folk dance students averaged (19 ± 1) years and dance training length was (6.0 ± 1.5) years. The students that studied other subjects had never taken part in dance training or other physical training, and their age averaged (22 ± 1) years, body height averaged (162 ± 5) cm, body mass averaged (51 ± 6) kg. All subjects had no prior ear disease or history of other neurological disorders. All students provided informed consent for the experimental project. METHODS: The neural electricity tester, NDI-200 (Shanghai Poseidon Medical Electronic Instrument Factory) was used to examine and record Brainstem Auditory Evoked Potential values of the subjects during silence, as well as to transversally analyze the Brainstem Auditory Evoked Potential values. The electrode positions were cleaned and degreased with soapy water, followed by ethanol. The selected bipolar electrodes were situated on the head: recording electrodes were placed at the Baihui acupoint, and the reference electrode was placed at the mastoid of the measured ear, with grounding electrodes in the center of the forehead. Brainstem Auditory Evoked Potential values were elicited by monaural stimulation of a "click" though an earphone; the other ear was sheltered by the white noise. The click intensity was 102 db, the stimulation frequency was 30 Hz, the bandpass filters were 1 000-3 000 Hz, the sensitivity was 5 ta V, and a total of 2 000 sweeps were averaged. Waveform identification and analysis: various components of the Brainstem Auditory Evoked Potential values were identified, and the peak latencies and peak-peak values were analyzed. MAIN OUTCOME MEASURES: Latency of Ⅰ , Ⅱ, Ⅲ, Ⅳ, Ⅴ and Peak-Peak Value of Ⅰ, Ⅲ, Ⅴwere measured. RESULTS: Fifty-five subjects were enrolled in the final analysis, without any loss. Compared to the students who studied other subjects ① Ⅰ -Ⅴ peak latencies (PL): Ⅳ PL of the right ear of the folk dance students was obviously longer (P 〈 0.05); ② Ⅰ, Ⅲ, V peak-peak values:Ⅰ peak-peak values of the right ear were obviously higher (P 〈 0.05). CONCUSION: ① PL of the right ear of the folk dance students was obviously longer, which indicates that dancing results in a stronger sensibility to auditory stimuli. ②. Peak-peak values were obviously higher, which indicates that long-term exercise enhances the music senses and synchrony of auditory nerve impulses.