期刊文献+
共找到4篇文章
< 1 >
每页显示 20 50 100
The Efficiency Analysis of the Exhaust Air Heat Pump System 被引量:1
1
作者 Alo Mikola Teet-Andrus Koiv 《Engineering(科研)》 2014年第13期1037-1045,共9页
This paper is based on long term parameter measurements of the exhaust air heat pumps (EAHP) system in a new built apartment building. The building was equipped with an exhaust air ventilation system and exhaust air h... This paper is based on long term parameter measurements of the exhaust air heat pumps (EAHP) system in a new built apartment building. The building was equipped with an exhaust air ventilation system and exhaust air heat pump for ventilation heat recover. The results of the measurements show that the COP of the EAHP is mainly related to the temperature graph of the heating system and the supply temperature of domestic hot water (DWH). During the measurement period some other impact factors, such as the quality of maintenance, the nighttime temperature graph of the heating system, the reduction of the exhaust air flows in case of low temperatures, mistakes in designing and low building quality, have also played a role. An analysis of energy consumption shows that in winter conditions the COP is about 3.0 and in the transition period about 3.3. The energy recovery value of the EAHP is 0.5. 展开更多
关键词 Heat Pump Exhaust air Heat Pump Heat Recovery Heat Requirement COP The Coefficient of Performance
下载PDF
The effects of exhaust air vent location on thermal comfort inside a residential building equipped with an evaporative cooling system 被引量:2
2
作者 rmin Saraei Samir Farid Moujaes 《Building Simulation》 SCIE EI CSCD 2021年第4期1063-1075,共13页
The location of exhaust air vents of an evaporative cooling system can have significant effects on providing thermal comfort and controlling humidity, temperature and air distribution in buildings. In the current stud... The location of exhaust air vents of an evaporative cooling system can have significant effects on providing thermal comfort and controlling humidity, temperature and air distribution in buildings. In the current study, four different strategies have been evaluated for exhaust air vent locations to provide the optimum thermal comfort inside a typical residential house. This study provides a numerical solution for temperature and relative humidity profiles in the residential house and within the living space in each room typically at a height of 1.8 m or less. By evaluating different exhaust air vent locations in a room, the best strategy(ies) to provide more appropriate thermal comfort condition and obtained and as a conclusion, the exhaust vents should be located on furthest wall away from the entrance of the room and in the middle. The results provided in the current study can eventually be applied in the design of evaporative cooler exhaust vent systems in residential buildings and lead to improve the performance of these systems. 展开更多
关键词 thermal comfort CFD evaporative cooling system exhaust air vents
原文传递
Design and analysis of a novel dual source vapor injection heat pump using exhaust and ambient air
3
作者 Jing Li Yi Fan +5 位作者 Xudong Zhao Xiaoman Bai Jinzhi Zhou Ali Badiei Steve Myers Xiaoli Ma 《Energy and Built Environment》 2022年第1期95-104,共10页
A novel dual source vapor injection heat pump(DSVIHP)using exhaust and ambient air is proposed.The air exhausted from the building first releases energy to the medium-pressure evaporator and is then mixed with the amb... A novel dual source vapor injection heat pump(DSVIHP)using exhaust and ambient air is proposed.The air exhausted from the building first releases energy to the medium-pressure evaporator and is then mixed with the ambient air to heat the low-pressure evaporator.A vapor injection(VI)compressor of two inlets is connected with the low and medium pressure evaporators.It’s first time that a VI compressor is employed to recover the ventilation heat.The system can minimize the ventilation heat loss and provide a unique defrosting approach by using the exhaust waste heat.Fundamentals of the proposed DSVIHP are illustrated.Mathematical models are built.Both energetic and exergetic analyses are carried out under variable conditions.The results indicate that the DSVIHP has superior thermodynamic performance.The superiority is more appreciable at a lower ambient temperature.It has a higher COP than the conventional vapor injection heat pump and air source heat pump by 11.3%and 23.2%respectively at an ambient temperature of-10°C and condensation temperature of 45°C.The waste heat recovery ratio from the exhaust air is more than 100%.The novel DSVIHP has great potential in the cold climate area application. 展开更多
关键词 Dual source vapor injection heat pump Exhaust air Waste heat recovery COP DEFROSTING
原文传递
BTEX pollution caused by motorcycles in the megacity of HoChiMinh 被引量:2
4
作者 Tran Thi Ngoc Lan Pham Anh Minh 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2013年第2期348-356,共9页
Monitoring of benzene, toluene and xylenes (BTEX) was conducted along with traffic counts at 17 roadside sites in urban areas of HoChiMinh. Toluene was the most abundant substance, followed by p,m-xylenes, benzene, ... Monitoring of benzene, toluene and xylenes (BTEX) was conducted along with traffic counts at 17 roadside sites in urban areas of HoChiMinh. Toluene was the most abundant substance, followed by p,m-xylenes, benzene, o-xylene and ethylbenzene. The maximum observed hour-average benzene concentration was 254 μg/m3 . Motorcycles contributed to 91% of the traffic fleet. High correlations among BTEX species, between BTEX concentrations and the volume of on-road motorcycles, and between inter-species ratios in air and in gasoline indicate the motorcycle-exhaust origin of BTEX species. Daily concentrations of benzene, toluene, ethylbenzene, p,m-xylenes and o-xylene were 56, 121, 21, 64 and 23 μg/m 3 , respectively. p,m-xylenes possess the highest ozone formation potential among the BTEX family. 展开更多
关键词 air pollution benzene BTEX HoChiMinh motorcycle exhaust
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部