Research on Verification Method of Motor Startups in Nuclear Power Plants Based on Topology Recognition
1
作者 Li Baozhu Dong Weijie Chen Chao 《系统仿真学报》 CAS CSCD 北大核心 2024年第12期2813-2823,共11页
There are many motors in operation or on standby in nuclear power plants,and the startup of group motors will have a great impact on the voltage of the emergency bus.At present,there is no special or inexpensive softw... There are many motors in operation or on standby in nuclear power plants,and the startup of group motors will have a great impact on the voltage of the emergency bus.At present,there is no special or inexpensive software to solve this problem,and the experience of engineers is not accurate enough.Therefore,this paper developed a method and system for the startup calculation of group motors in nuclear power plants and proposed an automatic generation method of circuit topology in nuclear power plants.Each component in the topology was given its unique number,and the component class could be constructed according to its type and upper and lower connections.The subordination and topology relationship of switches,buses,and motors could be quickly generated by the program according to the component class,and the simplified direct power flow algorithm was used to calculate the power flow for the startup of group motors according to the above relationship.Then,whether the bus voltage is in the safe range and whether the voltage exceeds the limit during the startup of the group motor could be judged.The practical example was used to verify the effectiveness of the method.Compared with other professional software,the method has high efficiency and low cost. 展开更多
关键词 power supply for nuclear power plant automatic topology recognition startup of group motor simplified direct power flow algorithm verification method
下载PDF
Review of Thermal Design of SiC Power Module for Motor Drive in Electrical Vehicle Application
2
作者 Puqi Ning Xiaoshuang Hui +3 位作者 Dongrun Li Yuhui Kang Jiajun Yang Chaohui Liu 《CES Transactions on Electrical Machines and Systems》 EI CSCD 2024年第3期332-346,共15页
In the current vehicle electric propulsion systems,the thermal design of power modules heavily relies on empirical knowledge,making it challenging to effectively optimize irregularly arranged Pinfin structures,thereby... In the current vehicle electric propulsion systems,the thermal design of power modules heavily relies on empirical knowledge,making it challenging to effectively optimize irregularly arranged Pinfin structures,thereby limiting their performance.This paper aims to review the underlying mechanisms of how irregularly arranged Pinfins influence the thermal characteristics of power modules and introduce collaborative thermal design with DC bus capacitor and motor.Literature considers chip size,placement,coolant flow direction with the goal of reducing thermal resistance of power modules,minimizing chip junction temperature differentials,and optimizing Pinfin layouts.In the first step,algorithms should efficiently generating numerous unique irregular Pinfin layouts to enhance optimization quality.The second step is to efficiently evaluate Pinfin layouts.Simulation accuracy and speed should be ensured to improve computational efficiency.Finally,to improve overall heat dissipation effectiveness,papers establish models for capacitors,motors,to aid collaborative Pinfin optimization.These research outcomes will provide essential support for future developments in high power density motor drive for vehicles. 展开更多
关键词 Thermal design power module Pinfin motor drive
下载PDF
Study on Matching a 300 MVA Motor Generator with an Ohmic Heating Power Supply in HL-2M 被引量:6
3
作者 彭建飞 宣伟民 +3 位作者 王海兵 李华俊 王英翘 王树锦 《Plasma Science and Technology》 SCIE EI CAS CSCD 2013年第3期300-302,共3页
A new 300 MVA/1350 MJ motor generator (MG) will be built to feed all of the poloidal field power supplies (PFPS) and auxiliary heating power supplies of the HL-2M tokamak. The MG has a vertical-shaft salient pole ... A new 300 MVA/1350 MJ motor generator (MG) will be built to feed all of the poloidal field power supplies (PFPS) and auxiliary heating power supplies of the HL-2M tokamak. The MG has a vertical-shaft salient pole 6-phase synchronous generator and a coaxial 8500 kW induction motor. The Ohmic heating power supply (OHPS) consisting of 4-quadrant DC pulsed convertor is the one with the highest parameters among the PFPS. Therefore, the match between the generator and the OHPS is very important. The matching study with Matlab/Simulink is described in this paper. The simulation results show that the subtransient reactance of the generator is closely related to the inversion operation of the OHPS. By setting various subtransient reactance in the simulation generator model and considering the cost reduction, the optimized parameters are obtained as xd" = 0.405 p.u. at 100 Hz for the generator. The models built in the simulation can be used as an important tool for studying the dynamic characteristics and the control strategy of other HL-2M PFPSes. 展开更多
关键词 motor generator ohmic heating power supply load matching six-phase gen-erator subtransient reactance
下载PDF
A Review of Gallium Nitride Power Device and Its Applications in Motor Drive 被引量:6
4
作者 Xiaofeng Ding Yang Zhou Jiawei Cheng 《CES Transactions on Electrical Machines and Systems》 CSCD 2019年第1期54-64,共11页
Wide band-gap gallium nitride(GaN)device has the advantages of large band-gap,high electron mobility and low dielectric constant.Compared with traditional Si devices,these advantages make it suitable for fast-switchin... Wide band-gap gallium nitride(GaN)device has the advantages of large band-gap,high electron mobility and low dielectric constant.Compared with traditional Si devices,these advantages make it suitable for fast-switching and high-power-density power electronics converters,thus reducing the overall weight,volume and power consumption of power electronic systems.As a review paper,this paper summarizes the characteristics and development of the state-of-art GaN power devices with different structures,analyzes the research status,and forecasts the application prospect of GaN devices.In addition,the problems and challenges of GaN devices were discussed.And thanks to the advantages of GaN devices,both the power density and efficiency of motor drive system are improved,which also have been presented in this paper. 展开更多
关键词 GAN motor drive power device
下载PDF
STUDY ON POWER SPARE COEFFICIENT OF ELECTRICAL MOTOR IN LARGE PUMP STATION BASED ON RELIABILITY 被引量:1
5
作者 QiuBaoyun HuangJiyan YuanShouqi 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2004年第4期498-501,共4页
Characters of head of low head pump station and the pump shaft power areanalyzed. Influence of each single factor on pump shaft power is expressed as change of specificshaft power. (non-dimensional) and the probabilit... Characters of head of low head pump station and the pump shaft power areanalyzed. Influence of each single factor on pump shaft power is expressed as change of specificshaft power. (non-dimensional) and the probability density function is determined. Influences ofmultiple factors on pump shaft power are analyzed. Method of calculating none over-loadedprobability of motor by integration by successive reductions is put forward and then relationbetween power spare coefficient and none over-loaded reliability of electric motor is established.Influences of all factors on pump shaft power being considered completely; power spare coefficientsof motor are calculated in three kinds of heads (changing and unchanging), two kinds of dirty-outconditions. Electrical motor power spare coefficients should be chosen as 1.20 approx 1.44, 1.11approx 1.19, 1.09 approx.14 respectively when pump heads are 4, 7, 9.5 m. The results mean much toreasonable choose of electrical motors in large pump stations, increasing reliability of pump unitsand saving equipment investment. 展开更多
关键词 Large pump station Electrical motor power spare coefficient Probability ofnone over-loaded
下载PDF
Optimal design of linear switched reluctance motor for sea wave power generation 被引量:2
6
作者 Zhao Xin Dongqin Xiong +2 位作者 Teng Yun Zhe Chen Guangwei Liu 《Global Energy Interconnection》 EI CAS CSCD 2022年第4期434-447,共14页
The switchless reluctance motor’s non-permanent magnet structure design ensures its high reliability in the marine environment;thus,it is a feasible solution for the generator of a sea wave power generation system.Ho... The switchless reluctance motor’s non-permanent magnet structure design ensures its high reliability in the marine environment;thus,it is a feasible solution for the generator of a sea wave power generation system.However,the corresponding thrust density and efficiency remain insufficient.This study focused on a new type of flat linear switched reluctance motor(LSRM),using the finite element software to establish a structural model,and optimized the design with the goal of improving the efficiency and energy density.The entropy method was adopted for sensitivity stratification to objectively select weights to avoid the influence of subjectively selected different proportional weights on the optimization results.Based on the entropy method,the sensitivity of different structural parameters was stratified,and the simulated annealing algorithm,response surface method,and single parameter scanning method were combined for optimization.Finally,the optimal structural size parameters of the motor were determined.Based on the two-dimensional finite element method,to simulate the electromagnetic performance of the reluctance motor under different operating conditions,such as thrust,loss,and efficiency,changes in motor performance before and after optimization were compared to verify the high power generation efficiency and energy density of the optimized linear motor. 展开更多
关键词 Linear switch reluctance motor Wave power Hierarchical optimization Generation efficiency
下载PDF
Research on the variable speed system of large power alternating current motor 被引量:1
7
作者 Li Chongjian 《Engineering Sciences》 EI 2012年第1期30-37,共8页
The development status of the variable speed system of large power AC(alternating current)motor drive in China is introduced.The large power AC drive fed by AC-AC converters(cycloconverters)has developed greatly,and s... The development status of the variable speed system of large power AC(alternating current)motor drive in China is introduced.The large power AC drive fed by AC-AC converters(cycloconverters)has developed greatly,and some innovations on the theory and engineering technique have been realized.They have been applied to rolling mills,mine hoists,and so on,and remarkable economic and social benefit has been achieved.The development of AC drive fed by large power IGCT(integrated gate commutated thyristors)AC-DC-AC converter is also introduced.It has excellent performance and reliable operation,and has been used in traction. 展开更多
关键词 large power AC motor CYCLOCONVERTER AC-DC-AC converter IGCT
下载PDF
An Investigation of Power Converters Fed BLDC Motor for Adjustable Speed 被引量:1
8
作者 Subramaniam Kaliappan Dr. Ramachandran Rajeswari 《Circuits and Systems》 2016年第8期1369-1378,共10页
This paper reports the converter topologies which are employed for better Power Factor Correction at the input side. The Power Factor Correction is an important factor when considering the Power Quality. Based on the ... This paper reports the converter topologies which are employed for better Power Factor Correction at the input side. The Power Factor Correction is an important factor when considering the Power Quality. Based on the converter topologies, the Bridgeless converters are preferred in order to reduce the number of switching devices, losses associated with it and improve the Power Quality further more. This paper investigates about the Power Factor performances and conduction losses of the Bridgeless Power Factor Corrector Converters which see through the benefits and limitations by analyzing the Bridgeless Buck-Boost Converter, Bridgeless SEPIC converter and Bridgeless CUK converter. The resultant voltage is fed to the BLDC motor which is rapidly replacing the Induction motor for its better operating characteristics. These strategies are being analyzed using the MATLAB/Simulink software and the results are verified through the experimental analysis. The converter choice is preferred through the performance characteristics and Power Factor Correction at the supply. The Power Factor obtained should be within the acceptable limits under IEC 61000-3-2 standards. 展开更多
关键词 BLDC motor power Factor Correction power Quality PFC Converters
下载PDF
New Approach to the Power Selection for Asynchronous Motor
9
作者 高建华 胡洪国 杨汝清 《Journal of Donghua University(English Edition)》 EI CAS 2001年第2期133-139,共7页
The heating calculation of three-phase squirrel- cage asynchronous motor on the condition of starting for a prescribed rotary angle is firstly studied with time dissection method and its corresponding algorithm is pro... The heating calculation of three-phase squirrel- cage asynchronous motor on the condition of starting for a prescribed rotary angle is firstly studied with time dissection method and its corresponding algorithm is provided. Then based upon the algorithm, a new method for motor power selection is established. Motor initial power determined by load power ischecked and modified in terms of time crit erion, heating criterion,and starting torque criterion.An appropriate motor power which meets three criterions is obtained at last, in the meantime, working displacement matrix andfrequency matrix used for control are acquired. Lifting motor of MDJ1800 low-level high- speed palletizer is taken as a reaI case in the paper. 展开更多
关键词 time dissection heating calculation frequent starting power selection THREE-PHASE squirrel-cage ASYNCHRONOUS motor
下载PDF
Dynamic Equivalent Method of Motor Loads for Power Systems Based on the Weighted
10
作者 Bo Hong Hanmei Hu +1 位作者 Ting Chen Qinfeng Li 《Journal of Power and Energy Engineering》 2014年第4期416-422,共7页
Dynamic equivalence can not only largely reduce the system size and the computation time but also stress the dominant features of the system [1]-[3]. This paper firstly recommends the basic concept of dynamic equivale... Dynamic equivalence can not only largely reduce the system size and the computation time but also stress the dominant features of the system [1]-[3]. This paper firstly recommends the basic concept of dynamic equivalent and the status of both domestic and abroad development in this area. The most existing equivalent methods usually only deal with static load models and neglect the dynamic characteristics of loads such as induction motors. In addition, the existing polymerization method which is based on the frequency domain algorithm of induction electric machines parameters takes a long time to equivalent for the large system, then the new method based on the weighted is proposed. Then, the basic steps for dynamic equivalence with the weighted method are introduced as follows. At first, the clustering criterion of motor loads based on time domain simulation is given. The motors with similar dynamic characteristics are classified into one group. Then, the simplication of the buses of motors in same group and network is carried out. Finally, parameters of the equivalent motor are calculated and the equivalent system is thus obtained based on the weighted. This aggregation method is applied to the simple distribution system of 4 generators. Simulation results show that the method can quickly obtain polymerization parameters of generator groups and the aggregation model retains the dynamic performance of the original model with good accuracy, the active and reactive power fitting error is smaller as well. 展开更多
关键词 power System DYNAMIC EQUIVALENT INDUCTION motors Parameter AGGREGATION The WEIGHTED Method
下载PDF
Frequency control system based on power factor control of asynchronous motor
11
作者 孟庆春 杨飞霞 任志玲 《Journal of Coal Science & Engineering(China)》 2005年第2期86-89,共4页
Deduced the relationship between the power factor (PF) and the angular fre-quency according to the simplified equivalent circuit of asynchronous motor, forming a power factor auto-control system. An anti-interference ... Deduced the relationship between the power factor (PF) and the angular fre-quency according to the simplified equivalent circuit of asynchronous motor, forming a power factor auto-control system. An anti-interference circuit was also introduced in the middle voltage link of inverter to avoid the shift of the optimum PF point caused by the change of the load and the reliable run of the control system was assured. The experi-ment results show that it has a good self-adaptation in the whole scope of speed ad-justment and an obvious economization on energy while it runs under load. 展开更多
关键词 asynchronous motor power factor(PF) auto-control economization on energy
下载PDF
Switching of Capacitors in an Asymmetric Induction Motor with Single-Phase Power,Triggering Several Applied Loads
12
作者 Prado Wellington Marcos Antonio Geraldo Caixeta Guimarães 《Journal of Energy and Power Engineering》 2020年第3期90-99,共10页
xThis study has as its objective to collaborate with the expansion in the market of electric energy in rural areas,offering as such an innovative prospect to the solution of associated problems through use of the asym... xThis study has as its objective to collaborate with the expansion in the market of electric energy in rural areas,offering as such an innovative prospect to the solution of associated problems through use of the asymmetric three-phase induction motor,supplied by a single-phase source.In this system,capacitor switching is applied during operation,while theoretical and practical results are presented for the application of this switching in a three-phase asymmetric induction motor of 20 hp. 展开更多
关键词 Startup current capacitor switching three-phase induction motor asymmetric motor power factor
下载PDF
Power Factor Improvement of AC-DC Converter Based on Separately Excited DC Motor Using Passive Filter
13
作者 Shazia Baloch Mukhtiar Ahmed Mahar +1 位作者 Raza Haider Shakeel Ahmed 《Open Journal of Energy Efficiency》 2016年第3期71-77,共8页
In industries DC motor drives are very essential due to their high performance applications such as its reliability, ease of control, low cost and simplicity. And speed control of these motors is very easy due to powe... In industries DC motor drives are very essential due to their high performance applications such as its reliability, ease of control, low cost and simplicity. And speed control of these motors is very easy due to power electronic AC-DC converters. These power electronic converters are with prominent low power factor and higher Total Harmonic Distortion (THD). These converters operate only for short time resulting non-sinusoidal waveform. This problem of harmonic distortion can be mitigated by reshaping the non-sinusoidal waveform to pure sine wave. Different wave shaping techniques have been developed by using different filters among which one is tuned passive filter. This paper proposed power factor improvement and harmonic mitigation of AC-DC converters based on separately excited DC motor using tuned passive filter. In this context experimental model is designed and results are analyzed by power quality analyzer. 展开更多
关键词 DC motors AC-DC Converters power Factor Total Harmonic Distortion Passive Filters
下载PDF
Efficiency of collective myosin Ⅱ motors studied with an elastic coupling power-stroke ratchet model
14
作者 Zi-Qing Wang Jin-Fang Li +2 位作者 Ying-Ge Xie Guo-Dong Wang Yao-Gen Shu 《Chinese Physics B》 SCIE EI CAS CSCD 2018年第12期559-562,共4页
We proposed a modified ratchet model including power-stroke and elastic coupling to study the efficiency of collective non-processive motors such as myosin Ⅱ in muscle. Our theoretical results are in good agreement w... We proposed a modified ratchet model including power-stroke and elastic coupling to study the efficiency of collective non-processive motors such as myosin Ⅱ in muscle. Our theoretical results are in good agreement with the experimental data. Our study not only reveals that the maximum efficiency depends on elasticity and is independent of transition rates but also indicates that the parameters fitted to fast muscle are different from those fitted to a slow one. The latter may imply that the structure of the fast muscle is different from that of the slow one. The main reason that our model succeeds is that velocity in this model is an independent variable. 展开更多
关键词 efficiency of collective non-processive motors ratchet model power-stroke elasticity
下载PDF
Modeling and Validation of Thrust Prediction of Underwater Solid Rocket Motor
15
作者 Shilin Hu Chao Yin +1 位作者 Wei Kang Muyao Xue 《World Journal of Engineering and Technology》 2024年第4期1090-1104,共15页
The solid rocket motor driven system is one of the common ways for submarines to launch underwater missiles. It has significant advantages in improving the missile’s water exit speed, anti-interference capability, an... The solid rocket motor driven system is one of the common ways for submarines to launch underwater missiles. It has significant advantages in improving the missile’s water exit speed, anti-interference capability, and enemy striking power. The prediction of the underwater loading is a preliminary factor for the power system design of the underwater vehicle. This paper presents a rapid prediction method and validated by the experimental study for the underwater thrust of the solid rocket motor. Based on the potential flow assumption of the water field, a model of the bubble and a one-dimensional quasi-steady model of the nozzle are established to directly solve the flow status of the nozzle. The aerodynamic thrust and hydrodynamic thrust have been calculated and analyzed. The calculation results are within 5% error of the experimental results. Moreover, a design platform to predict the underwater thrust of the solid rocket motor has been developed based on Python and the PyQt library, which shows excellent system adaptability and computational efficiency. 展开更多
关键词 power System Design Underwater Vehicle Solid Rocket motor Thrust Prediction
下载PDF
基于Power Systems Blockset的电路与电机仿真分析 被引量:1
16
作者 郑亚民 蒋保臣 《电气电子教学学报》 2003年第2期55-58,共4页
介绍了基于PowerSystemsBlockset电路与电机的仿真分析法 ,建立了电路模型并进行了正弦稳态仿真分析 ,又建立了电机仿真模型并获得了电机的工作特性 ,另外对绕线式异步电机转子回路串电阻的启动过程进行了仿真。仿真结果与理论分析一致 ... 介绍了基于PowerSystemsBlockset电路与电机的仿真分析法 ,建立了电路模型并进行了正弦稳态仿真分析 ,又建立了电机仿真模型并获得了电机的工作特性 ,另外对绕线式异步电机转子回路串电阻的启动过程进行了仿真。仿真结果与理论分析一致 ,且建模与仿真过程非常简洁 ,说明该方法非常适于电路的正弦稳态分析和异步电机及其拖动系统的动态仿真。 展开更多
关键词 powerSystemsBlockset 电路 电机 电力系统模块库
下载PDF
Rockwell Micro800PLC与Power flex变频器控制电机
17
作者 胡霞 刘张 《煤矿机械》 2015年第9期305-308,共4页
Rockwell Micro800系列PLC通过Ethernet/IP端口接入Ethernet中,与其他的通讯设备相连接,因此可以将PLC与Power Flex变频器进行连接,然后通过在变频器的组态界面中添加外接设备后,进行实际设备的连接,如此将PLC与变频器和电机连接在一起... Rockwell Micro800系列PLC通过Ethernet/IP端口接入Ethernet中,与其他的通讯设备相连接,因此可以将PLC与Power Flex变频器进行连接,然后通过在变频器的组态界面中添加外接设备后,进行实际设备的连接,如此将PLC与变频器和电机连接在一起。通过在Micro800控制器的编程软件中编写程序,通过上传设备信息和下载程序到PLC中来实现对电机的正反转和启动停止等控制,还可以修改变频器的参数来达到改变电机状态的目的。 展开更多
关键词 ROCKWELL micro800 PLC power Flex变频器 电机控制
下载PDF
Direct Torque Control System and Sensorless Technique of Permanent Magnet Synchronous Motor 被引量:10
18
作者 胡育文 田淳 +2 位作者 游志青 汤立新 M.F.Rahman 《Chinese Journal of Aeronautics》 SCIE EI CAS CSCD 2003年第2期97-102,共6页
The direct torque control theory has achieved great success in the control ofinduction motors. However, in the DTC drive system of Permanent Magnet Synchronous Machine (PMSM)proposed a few years ago, there are many ba... The direct torque control theory has achieved great success in the control ofinduction motors. However, in the DTC drive system of Permanent Magnet Synchronous Machine (PMSM)proposed a few years ago, there are many basic theoretical problems that must be clarified. Thispaper describes an investigation about the effect of the zero voltage space vectors in the DTCsystem of PMSM and points out that if using the zero voltage space vectors rationally, not only canthe DTC system be driven successfully but also the torque ripple is reduced and the performance ofthe system is improved. This paper also studies the sensorless technique in the DTC system of PMSMand configures the DTC system of PMSM with sensorless technique including zero voltage spacevectors. Numerical simulations and experimental tests have proved the theory correct. In thecondition of sensor-less, the DTC system of PMSM is wide-rangely speed adjusting, and the ratio ofspeed adjustment is 1: 100. 展开更多
关键词 power electronics direct torque control permanent magnet motors SENSORLESS stator flux linkage
下载PDF
Sliding Mode Control in Power Converters and Drives: A Review 被引量:7
19
作者 Ligang Wu Jianxing Liu +1 位作者 Sergio Vazquez Sudip K.Mazumder 《IEEE/CAA Journal of Automatica Sinica》 SCIE EI CSCD 2022年第3期392-406,共15页
Sliding mode control(SMC)has been studied since the 1950s and widely used in practical applications due to its insensitivity to matched disturbances.The aim of this paper is to present a review of SMC describing the k... Sliding mode control(SMC)has been studied since the 1950s and widely used in practical applications due to its insensitivity to matched disturbances.The aim of this paper is to present a review of SMC describing the key developments and examining the new trends and challenges for its application to power electronic systems.The fundamental theory of SMC is briefly reviewed and the key technical problems associated with the implementation of SMC to power converters and drives,such chattering phenomenon and variable switching frequency,are discussed and analyzed.The recent developments in SMC systems,future challenges and perspectives of SMC for power converters are discussed. 展开更多
关键词 motor drive power electronics systems sliding mode control
下载PDF
A Study of Motor Bearing Fault Diagnosis using Modulation Signal Bispectrum Analysis of Motor Current Signals 被引量:3
20
作者 Ahmed Alwodai Tie Wang +3 位作者 Zhi Chen Fengshou Gu Robert Cattley Andrew Ball 《Journal of Signal and Information Processing》 2013年第3期72-79,共8页
Failure of induction motors are a large concern due to its influence over industrial production. Motor current signature analysis (MCSA) is common practice in industry to find motor faults. This paper presents a new a... Failure of induction motors are a large concern due to its influence over industrial production. Motor current signature analysis (MCSA) is common practice in industry to find motor faults. This paper presents a new approach to detection and diagnosis of motor bearing faults based on induction motor stator current analysis. Tests were performed with three bearing conditions: baseline, outer race fault and inner race fault. Because the signals associated with faults produce small modulations to supply component and high nose levels, a modulation signal bispectrum (MSB) is used in this paper to detect and diagnose different motor bearing defects. The results show that bearing faults can induced a detestable amplitude increases at its characteristic frequencies. MSB peaks show a clear difference at these frequencies whereas conventional power spectrum provides change evidences only at some of the frequencies. This shows that MSB has a better and reliable performance in extract small changes from the faulty bearing for fault detection and diagnosis. In addition, the study also show that current signals from motors with variable frequency drive controller have too much noise and it is unlikely to discriminate the small bearing fault component. 展开更多
关键词 INDUCTION motor motor Current SIGNATURE power Spectrum BISPECTRUM motor BEARING
下载PDF