期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
Weatherability Studies on External Insulation Thermal System of Expanded Polystyrene Board,Polystyrene Granule and Polyurethane Foam 被引量:5
1
作者 尹秀琴 《Journal of Wuhan University of Technology(Materials Science)》 SCIE EI CAS 2010年第6期1027-1032,共6页
Atmospheric exposure tests including two experimental stages of high temperature-spraying water cycle and heating-refrigeration cycle were carried out on three currently used ETIS of expanded polystyrene(EPS) board,... Atmospheric exposure tests including two experimental stages of high temperature-spraying water cycle and heating-refrigeration cycle were carried out on three currently used ETIS of expanded polystyrene(EPS) board,polystyrene granule mortar and polyurethane foam in order to study the weatherablility of external thermal insulation system(ETIS).The change rules of adhesive strength were hereby studied at different time period of atmospheric exposure tests.The experimental results show that the adhesive strength of three kinds of ETIS changes a little during high temperature-spraying water cycle,but the adhesive strength of ETIS with EPS board decreases significantly after heating-refrigeration cycle.The lowering rate of adhesive strength with painting finishes is obviously faster than that of tile finishes for ETIS of EPS board during heating-refrigeration cycle.The weatherability of ETIS with EPS board is worse than the other two,and ETIS of polystyrene granule mortar and polyurethane foam are more suitable than ETIS of EPS board in cold area. 展开更多
关键词 external thermal insulation system EPS board polystyrene granule atmospheric exposure tests adhesive strength
下载PDF
Evaluation of repeated exposure systemic toxicity test of PVC with new plasticizer on rats via dual parenteral routes
2
作者 Li Hou Chunguang Fan +3 位作者 Chenghu Liu Qiujin Qu ChunrenWang Yanping Shi 《Regenerative Biomaterials》 SCIE 2018年第1期9-14,共6页
Systemic toxicity caused by repeated exposure to both polar and nonpolar leachables of di(2-ethylhexyl)-1,2-cyclohexane plasticized polyvinyl chloride(PVC)was evaluated with dual routes of parenteral administration me... Systemic toxicity caused by repeated exposure to both polar and nonpolar leachables of di(2-ethylhexyl)-1,2-cyclohexane plasticized polyvinyl chloride(PVC)was evaluated with dual routes of parenteral administration method on rats in the study.Experimental group and control group were designed by researchers.Tail intravenous injection with 0.9%sodium chloride injection extracts and intraperitoneal injection with corn oil extracts were conducted to the experimental rats while tail intravenous injection with 0.9%sodium chloride Injection and intraperitoneal injection with corn oil were conducted to the control rats.After 14 days,blood specimens were collected for clinical pathology(hematology and clinical chemistry)analysis.Selected organs were weighed and a histopathological examination was conducted.As a result,compared with the control animals,there were no toxicity-related changes on the parameters above.The results show that the rats do not show obvious systemic toxicity reaction caused by repeated exposure with dual routes of parenteral administration method on rats after administration with both polar and nonpolar exacts of di(2-ethylhexyl)-1,2-cyclohexane plasticized PVC simultaneously up for 14 days. 展开更多
关键词 plasticized PVC repeated exposure systemic toxicity test dual routes of parenteral administration method
原文传递
Correlation between indoor and outdoor corrosion tests for coal train body steel in a coal medium environment 被引量:2
3
作者 Jia-liang Song Jun-hang Chen +3 位作者 Pan Yi Na-na Chen Zhao-liang Li Kui Xiao 《Journal of Iron and Steel Research International》 SCIE EI CAS CSCD 2022年第9期1495-1504,共10页
Q345B carbon steel as well as Q450NQR1 and S500AW weathering steels were subjected to outdoor exposure corrosion tests in coal environments and indoor periodic immersion accelerated corrosion tests with a simulated co... Q345B carbon steel as well as Q450NQR1 and S500AW weathering steels were subjected to outdoor exposure corrosion tests in coal environments and indoor periodic immersion accelerated corrosion tests with a simulated coal leaching solution.The corrosion kinetics were studied by the weight loss method,and the corrosion morphology and corrosion product composition were observed and analyzed by scanning electron microscopy,energy-dispersive spectroscopy and X-ray diffraction.Afterward,correlation analysis of the indoor and outdoor tests was carried out by the gray correlation analysis method.The results show that the relationship between the corrosion weight loss and corrosion time of the three steels conforms to follow the exponent power law.In particular,Q450NQR1 steel has the best corrosion resistance.The types of corrosion products and the distribution of elements in the rust layer of the three steels are similar in the indoor and outdoor tests.The gray correlation degrees of the three steels in the indoor and outdoor tests are all greater than 0.6;thus,the two corrosion tests have a good correlation.Based on this,the accelerated simulation test method of the coal leaching solution is determined,and life prediction models of three steels in coal leaching solution are established to simulate the corrosion of the bottom board and side board. 展开更多
关键词 Coal train body steel Coal environment-Corrosion Outdoor exposure test Indoor acceleration test Correlation
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部