This study examined the thermal effects of building′s external wall surfaces, using observational data of spatial-temporal distribution of surface temperature, air temperature, and heat flux into and out of external ...This study examined the thermal effects of building′s external wall surfaces, using observational data of spatial-temporal distribution of surface temperature, air temperature, and heat flux into and out of external surface. Results indicate that external wall surface temperature and nearby air temperature vary with the change of orientation, height and season. In general, the external wall surface temperature is lower near the ground, and is higher near the roof, than nearby air temperature. But north wall surface temperature is mostly lower than nearby air temperature at the same height; south wall surface temperature during the daytime in December, and west wall surface temperature all day in August, is respectively higher than nearby air temperature. The heat fluxes into and out of external wall surfaces show the differences that exist in the various orientations, heights and seasons. In December, south wall surface at the lower sites emits heat and north wall surface at the higher sites absorbs heat. In April, all external wall surfaces, emit heat near the ground and absorb heat near the roof. In August, west wall surface all day emits heat, and other wall surfaces just show the commensurate behavior with that in April.展开更多
Internal and external wall surface temperatures (Tws) in April, August and December in Kunming, a city in low latitude plateau, were investigated. Results showed that the Tws in April were of the highest among the thr...Internal and external wall surface temperatures (Tws) in April, August and December in Kunming, a city in low latitude plateau, were investigated. Results showed that the Tws in April were of the highest among the three, followed by August and December. The Tws differences among walls with different orientation were higher in April and December when the weather tends to be sunny, and lower in August with more cloudy days in the time. In April and August, Tws of E-wall was the highest, followed by S- and N-wall. But in December Tws of S-wall might be sometimes higher than E one. Diurnal range of internal Tws was usually smaller than that of the external, with also a time lag for the occurrence of its maximum and minimum. The results can serve as a basis for further research on building microclimate and urban architecture designs. It also gives suggestions for similar studies in other areas.展开更多
Bushfire-related building losses cause adverse economic impacts to countries prone to bushfires.Building materials and components play a vital role in reducing these impacts.However,due to high costs of experimental s...Bushfire-related building losses cause adverse economic impacts to countries prone to bushfires.Building materials and components play a vital role in reducing these impacts.However,due to high costs of experimental studies and lack of numerical studies,the heat transfer behavior of building’s external components in bushfire-prone areas has not been adequately investigated.Often large-scale heat transfer models are developed using Computational Fluid Dynamics(CFD)tools,and the availability of CFD models for heat transfer in building components improves the understanding of the behavior of systems and systems of systems.Therefore,this paper uses a numerical modeling approach to investigate the bushfire/wildfire resistance of external Light gauge Steel Framed(LSF)wall systems.Both full-scale and small-scale heat transfer models were developed for the LSF wall systems.Experimental results of six internal and external LSF wall systems with varying plasterboard thickness and cladding material were used to validate the developed models.The study was then extended to investigate the bushfire resistance of seven external wall systems under two different bushfire flame zone conditions.The results illustrate the significant effects of fire curves,LSF wall components and configuration on the heat transfer across the walls.They have shown 1)the favorable performance of steel cladding and Autoclaved Aerated Concrete(AAC)panels when used on the external side of wall systems and 2)the adequacy of thin-walled steel studs’load-bearing capacity during bushfire exposures.This study has shown that most of the investigated external LSF walls could be reused with cost-effective retrofitting such as replacing the Fire Side(FS)steel cladding after bushfire exposures.Overall,this study has advanced the understanding of the behavior of external light steel framed walls under bushfire flame zone conditions.展开更多
As the variation and timely meeting thermal environment requirement of indoor air temperature has a close relationship with the thermal performance of building external wall under discontinuous radiant heating conditi...As the variation and timely meeting thermal environment requirement of indoor air temperature has a close relationship with the thermal performance of building external wall under discontinuous radiant heating condition, one appropriate assessment method or index for assessing the building external wall thermal performance is very necessary. In order to reasonably evaluate the thermal performance of external wall under discontinuous radiant heating condition and build the direct connections and interactions among the indoor air temperature, external wall inner surface temperature and outdoor air temperature, the first and second impact factors of temperature deviation were established, based on one mathematical model of room heat transfer. For one experimental room and four types of external walls under discontinuous radiant heating condition, both the influence of the external wall inner surface temperature deviation on the indoor air temperature and that of the outdoor air temperature deviation on the external wall inner surface temperature were determined effectively with the first and second impact factors of temperature deviation. In addition, favourable performance for the self-insulation and inner insulation walls were found, due to their superiority in effectively and timely improving the indoor thermal environment under discontinuous radiant heating condition.展开更多
文摘This study examined the thermal effects of building′s external wall surfaces, using observational data of spatial-temporal distribution of surface temperature, air temperature, and heat flux into and out of external surface. Results indicate that external wall surface temperature and nearby air temperature vary with the change of orientation, height and season. In general, the external wall surface temperature is lower near the ground, and is higher near the roof, than nearby air temperature. But north wall surface temperature is mostly lower than nearby air temperature at the same height; south wall surface temperature during the daytime in December, and west wall surface temperature all day in August, is respectively higher than nearby air temperature. The heat fluxes into and out of external wall surfaces show the differences that exist in the various orientations, heights and seasons. In December, south wall surface at the lower sites emits heat and north wall surface at the higher sites absorbs heat. In April, all external wall surfaces, emit heat near the ground and absorb heat near the roof. In August, west wall surface all day emits heat, and other wall surfaces just show the commensurate behavior with that in April.
基金Key project from the Natural Science Foundation of China (59836250)
文摘Internal and external wall surface temperatures (Tws) in April, August and December in Kunming, a city in low latitude plateau, were investigated. Results showed that the Tws in April were of the highest among the three, followed by August and December. The Tws differences among walls with different orientation were higher in April and December when the weather tends to be sunny, and lower in August with more cloudy days in the time. In April and August, Tws of E-wall was the highest, followed by S- and N-wall. But in December Tws of S-wall might be sometimes higher than E one. Diurnal range of internal Tws was usually smaller than that of the external, with also a time lag for the occurrence of its maximum and minimum. The results can serve as a basis for further research on building microclimate and urban architecture designs. It also gives suggestions for similar studies in other areas.
基金the Australian Research Council(ARC Grant Nos.DE180101598 and DP200102704)Queensland University of Technology(QUT)for providing financial support.
文摘Bushfire-related building losses cause adverse economic impacts to countries prone to bushfires.Building materials and components play a vital role in reducing these impacts.However,due to high costs of experimental studies and lack of numerical studies,the heat transfer behavior of building’s external components in bushfire-prone areas has not been adequately investigated.Often large-scale heat transfer models are developed using Computational Fluid Dynamics(CFD)tools,and the availability of CFD models for heat transfer in building components improves the understanding of the behavior of systems and systems of systems.Therefore,this paper uses a numerical modeling approach to investigate the bushfire/wildfire resistance of external Light gauge Steel Framed(LSF)wall systems.Both full-scale and small-scale heat transfer models were developed for the LSF wall systems.Experimental results of six internal and external LSF wall systems with varying plasterboard thickness and cladding material were used to validate the developed models.The study was then extended to investigate the bushfire resistance of seven external wall systems under two different bushfire flame zone conditions.The results illustrate the significant effects of fire curves,LSF wall components and configuration on the heat transfer across the walls.They have shown 1)the favorable performance of steel cladding and Autoclaved Aerated Concrete(AAC)panels when used on the external side of wall systems and 2)the adequacy of thin-walled steel studs’load-bearing capacity during bushfire exposures.This study has shown that most of the investigated external LSF walls could be reused with cost-effective retrofitting such as replacing the Fire Side(FS)steel cladding after bushfire exposures.Overall,this study has advanced the understanding of the behavior of external light steel framed walls under bushfire flame zone conditions.
基金financial support from the Huimin Project of Chengdu Science and Technology Grant No. 2015-HM01-00548-SFthe National Nature Science Foundation of China under Grant No. 51308361Science and Technology Plan Project in Sichuan province Grant No. 2014GZ0133
文摘As the variation and timely meeting thermal environment requirement of indoor air temperature has a close relationship with the thermal performance of building external wall under discontinuous radiant heating condition, one appropriate assessment method or index for assessing the building external wall thermal performance is very necessary. In order to reasonably evaluate the thermal performance of external wall under discontinuous radiant heating condition and build the direct connections and interactions among the indoor air temperature, external wall inner surface temperature and outdoor air temperature, the first and second impact factors of temperature deviation were established, based on one mathematical model of room heat transfer. For one experimental room and four types of external walls under discontinuous radiant heating condition, both the influence of the external wall inner surface temperature deviation on the indoor air temperature and that of the outdoor air temperature deviation on the external wall inner surface temperature were determined effectively with the first and second impact factors of temperature deviation. In addition, favourable performance for the self-insulation and inner insulation walls were found, due to their superiority in effectively and timely improving the indoor thermal environment under discontinuous radiant heating condition.
文摘为了对比日光温室传统保温蓄热后墙与基于毛细管网的主动式集放热系统(AHSCTM)的集放热性能,对AHSCTM的集放热性能进行了测试,构建了AHSCTM水温模型,利用一维差分法对相同环境条件下的外保温复合墙(370 mm黏土砖和100 mm聚苯乙烯板复合而成)日间储热量和夜间放热量进行了模拟。结果表明,AHSCTM的日间储热量和夜间放热量分别为相同条件下外保温复合墙的84.4%~111.3%和74.8%~100.7%,AHSCTM的COP(Coefficient of performance)为1.1~2.4。在夜间运行期间,AHSCTM放热量是相同时间段内外保温复合墙的98.2%~172.5%。因此,与外保温复合墙相比,AHSCTM有利于提高室内最低气温。改进AHSCTM的日间储热量和夜间放热量得到大幅提升,分别较外保温复合墙高67.6%~112.1%和69.0%~128.3%,COP可达2.8~7.0。改进AHSCTM的储放热性能优于外保温复合墙,说明利用改进AHSCTM配合保温墙体替代传统保温蓄热后墙是可行的。