Thermodynamic concepts required for the thermodynamic calculation of the potentials of electrodes for high temperature applications are briefly reviewed. A thermodynamic approach to the calculation of half cell potent...Thermodynamic concepts required for the thermodynamic calculation of the potentials of electrodes for high temperature applications are briefly reviewed. A thermodynamic approach to the calculation of half cell potentials and the standard chemical potential of an electron at high temperatures which are related to the Standard Hydrogen Electrode(SHE) is discussed. As examples, an external Ag/AgCl reference electrode and a YSZ(Ag|O_2) pH sensor for high temperature applications are analyzed by using the thermodynamic approach to derive a high temperature pH measurement equation. The two electrodes are employed to measure high temperature pH and the measured pH was compared with the calculated pH by using a solution chemistry method. Concepts and principles for electrode kinetics are also briefly introduced and a modification to the Tafel equations is suggested.展开更多
The objective of this study is to demonstrate that tensile stress resulting due to applied force on cornea can be accurately measured by using a time-domain common-path optical coherence tomography (OCT) system with...The objective of this study is to demonstrate that tensile stress resulting due to applied force on cornea can be accurately measured by using a time-domain common-path optical coherence tomography (OCT) system with an external contact reference. The unique design of the common-path OCT is utilized to set up an imaging system in which a chicken eye is placed adjacent to a glass plate serving as the external reference plane for the imaging system. As the force is applied to the chicken eye, it presses against the reference glass plate. The modified OCT image obtained is used to calculate the size of contact area, which is then used to derive the tensile stress on the cornea. The drop in signal levels upon contact of reference glass plate with the tissue are extremely sharp because of the sharp decline in reference power levels itself, thus providing us with an accurate measurement of contact area. The experimental results were in good agreement with the numerical predictions. The results of this study might be useful in providing new insights and ideas to improve the precision and safety of currently used ophthalmic surgical techniques. This research outlines a method which could be used to provide high resolution OCT images and a precise feedback of the forces applied to the cornea simultaneously.展开更多
文摘Thermodynamic concepts required for the thermodynamic calculation of the potentials of electrodes for high temperature applications are briefly reviewed. A thermodynamic approach to the calculation of half cell potentials and the standard chemical potential of an electron at high temperatures which are related to the Standard Hydrogen Electrode(SHE) is discussed. As examples, an external Ag/AgCl reference electrode and a YSZ(Ag|O_2) pH sensor for high temperature applications are analyzed by using the thermodynamic approach to derive a high temperature pH measurement equation. The two electrodes are employed to measure high temperature pH and the measured pH was compared with the calculated pH by using a solution chemistry method. Concepts and principles for electrode kinetics are also briefly introduced and a modification to the Tafel equations is suggested.
文摘The objective of this study is to demonstrate that tensile stress resulting due to applied force on cornea can be accurately measured by using a time-domain common-path optical coherence tomography (OCT) system with an external contact reference. The unique design of the common-path OCT is utilized to set up an imaging system in which a chicken eye is placed adjacent to a glass plate serving as the external reference plane for the imaging system. As the force is applied to the chicken eye, it presses against the reference glass plate. The modified OCT image obtained is used to calculate the size of contact area, which is then used to derive the tensile stress on the cornea. The drop in signal levels upon contact of reference glass plate with the tissue are extremely sharp because of the sharp decline in reference power levels itself, thus providing us with an accurate measurement of contact area. The experimental results were in good agreement with the numerical predictions. The results of this study might be useful in providing new insights and ideas to improve the precision and safety of currently used ophthalmic surgical techniques. This research outlines a method which could be used to provide high resolution OCT images and a precise feedback of the forces applied to the cornea simultaneously.