期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Thermodynamic Foundation for High Temperature Electrochemistry
1
作者 ZHANG W. E. A. Charles J. Congleton 《Chemical Research in Chinese Universities》 SCIE CAS CSCD 2004年第4期494-500,共7页
Thermodynamic concepts required for the thermodynamic calculation of the potentials of electrodes for high temperature applications are briefly reviewed. A thermodynamic approach to the calculation of half cell potent... Thermodynamic concepts required for the thermodynamic calculation of the potentials of electrodes for high temperature applications are briefly reviewed. A thermodynamic approach to the calculation of half cell potentials and the standard chemical potential of an electron at high temperatures which are related to the Standard Hydrogen Electrode(SHE) is discussed. As examples, an external Ag/AgCl reference electrode and a YSZ(Ag|O_2) pH sensor for high temperature applications are analyzed by using the thermodynamic approach to derive a high temperature pH measurement equation. The two electrodes are employed to measure high temperature pH and the measured pH was compared with the calculated pH by using a solution chemistry method. Concepts and principles for electrode kinetics are also briefly introduced and a modification to the Tafel equations is suggested. 展开更多
关键词 High temperature potential Half cell potential external Ag/AgCl reference electrode Standard chemical potential of an electron High temperature pH sensor.
下载PDF
Simultaneous imaging and measurement of tensile stress on cornea by using a common-path optical coherence tomography system with an external contact reference
2
作者 Utkarsh Sharma Jin U.Kang 《Chinese Optics Letters》 SCIE EI CAS CSCD 2008年第12期910-912,共3页
The objective of this study is to demonstrate that tensile stress resulting due to applied force on cornea can be accurately measured by using a time-domain common-path optical coherence tomography (OCT) system with... The objective of this study is to demonstrate that tensile stress resulting due to applied force on cornea can be accurately measured by using a time-domain common-path optical coherence tomography (OCT) system with an external contact reference. The unique design of the common-path OCT is utilized to set up an imaging system in which a chicken eye is placed adjacent to a glass plate serving as the external reference plane for the imaging system. As the force is applied to the chicken eye, it presses against the reference glass plate. The modified OCT image obtained is used to calculate the size of contact area, which is then used to derive the tensile stress on the cornea. The drop in signal levels upon contact of reference glass plate with the tissue are extremely sharp because of the sharp decline in reference power levels itself, thus providing us with an accurate measurement of contact area. The experimental results were in good agreement with the numerical predictions. The results of this study might be useful in providing new insights and ideas to improve the precision and safety of currently used ophthalmic surgical techniques. This research outlines a method which could be used to provide high resolution OCT images and a precise feedback of the forces applied to the cornea simultaneously. 展开更多
关键词 Simultaneous imaging and measurement of tensile stress on cornea by using a common-path optical coherence tomography system with an external contact reference
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部