In this study,a detailed analysis of the combustion behaviors of the lithium iron phosphate(LFP)and lithium manganese oxide(LMO)batteries used in electric bicycles was conducted.This research included quantitative mea...In this study,a detailed analysis of the combustion behaviors of the lithium iron phosphate(LFP)and lithium manganese oxide(LMO)batteries used in electric bicycles was conducted.This research included quantitative measurements of the combustion duration,flame height,combustion temperature,heat release rate,and total heat release.The results indicated that LMO batteries exhibited higher combustion temperatures of 600–700°C,flame heights of 70–75 cm,a significantly higher heat release rate of40.1 k W(12 Ah),and a total heat release of 1.04 MJ(12 Ah)compared to LFP batteries with the same capacity.Based on these experimental results,a normalized total heat release(NORTHR)parameter was proposed,demonstrating good universality for batteries with different capacities.Utilizing this parameter,quantitative calculations and optimization of the extinguishing agent dosage were conducted for fires involving these two types of batteries,and the method was validated by extinguishing fires for these two types of battery packs with water-based extinguishing fluids.展开更多
The paper summarizes the structure and water-absorbing mechanism,classification,and preparation method of polymer fire extinguishing gel,and prospects for its application in aerial firefighting,forest ground fire exti...The paper summarizes the structure and water-absorbing mechanism,classification,and preparation method of polymer fire extinguishing gel,and prospects for its application in aerial firefighting,forest ground fire extinguishing,opening of firebreaks,and mitigating human casualties in forest fire extinguishing.展开更多
Fire incidents in commercial vehicles pose significant risks to passengers, drivers, and cargo. Traditional fire extinguishing systems, while effective, may have limitations in terms of response time, coverage, and hu...Fire incidents in commercial vehicles pose significant risks to passengers, drivers, and cargo. Traditional fire extinguishing systems, while effective, may have limitations in terms of response time, coverage, and human intervention [1]. This study investigates the efficacy of a novel fire suppression technology—the Exploding Fire Extinguishing Ball (EFEB) —as an alternative and complementary fire safety solution for commercial vehicles. The research employs a multidisciplinary approach, encompassing engineering, materials science, fire safety, and human factors analysis. A systematic literature review establishes a comprehensive understanding of existing fire suppression technologies, including EFEBs. Subsequently, this study analyzes the unique features of EFEBs, such as automatic activation, as well as manual activation upon exposure to fire, and their potential to provide rapid, localized, and autonomous fire suppression. The study presents original experimental investigations to assess the performance and effectiveness of EFEBs in various fire scenarios representative of commercial vehicles. Experiments include controlled fires in confined spaces and dynamic simulations to emulate real-world fire incidents. Data on activation times, extinguishing capability, and coverage area are collected and analyzed to compare the efficacy of EFEBs with traditional fire extinguishing methods. Furthermore, this research shows the practical aspects of implementing EFEBs in commercial vehicles. A feasibility study examines the integration challenges, cost-benefit analysis, and potential regulatory implications. The study also addresses the impact of EFEBs on vehicle weight, stability, and overall safety. Human factors and user acceptance are crucial elements in adopting new safety technologies. Therefore, this research utilizes an experimental design to assess the performance and effectiveness of EFEBs in various fire scenarios representative of commercial vehicles. This dissertation presents original controlled experiments to emulate real-world fire incidents, including controlled fires in confined spaces and dynamic simulations. The experimental approach ensures rigorous evaluation and objective insights into EFEBs’ potential as an autonomous fire suppression system for commercial vehicles. This includes the perspectives of drivers, passengers, fleet operators, insurance agencies, and regulatory bodies. Factors influencing trust, perceived safety, and willingness to adopt EFEBs are analyzed to provide insights into the successful integration of this technology. The findings of this research will contribute to the knowledge of fire safety technology and expand the understanding of the applicability of EFEBs in commercial vehicles.展开更多
To solve the problem of sealing between the barrel and the rubber ring of shell body during an launching process of aerodynamic extinguishing cannon, a rubber sealing model with bionic dimpled characteristics was esta...To solve the problem of sealing between the barrel and the rubber ring of shell body during an launching process of aerodynamic extinguishing cannon, a rubber sealing model with bionic dimpled characteristics was established based on the theory of bionic dimpled drag reduction and the principle of rubber sealing. In condition that the bionic dimpled characteristic diameters were 1, 2, 3, 4, and 5 mm, respectively, by numerical simulation, the influence of the installing compression of the rubber sealing ring on its surface stress and deformation was analyzed, and sealing performance of the rubber ring with different diameters of bionic dimpled was studied. The results show that the deformation of rubber ring appears prominent nonlinear characteristics when compression is increased from 1.5 mm to 2.5 ram. When the compression is 2.5 mm, the equivalent compression stress on the sealing areas of both sides of the rubber seal is greater than the working pressure of aerodynamic extinguishing cannon, which could meet the sealing requirement and would not cause leakage. So the rubber sealing ring with bionic dimpled surface possesses a good sealing characteristic and has no negative effect on the sealing of shell body; When the compression is 2.5 mm, the larger equivalent stress on the edge of sealing ring and the more even stress distribution in the high pressure area are generated due to the smaller compressive stress on the bionic dimple areas, which lays a foundation for the drag reduction characteristics of the shell body's rubber ring with bionic dimpled surface.展开更多
The dielectric barrier discharge(DBD)is presently used in many fields,in eluding plasma medicine,surface modification,and ozone synthesis;the influe nee of airflow on the DBD is a widely investigated topic.In this wor...The dielectric barrier discharge(DBD)is presently used in many fields,in eluding plasma medicine,surface modification,and ozone synthesis;the influe nee of airflow on the DBD is a widely investigated topic.In this work,a hysteresis characteristic on the initiating and extinguishing boundaries is observed in a nanosecond pulsed DBD,which is sensitive to the variation in the airflow velocities and pulse repetition frequencies(PRFs).It is found that,at a certain airflow velocity,the initiating PRF is higher than the extinguishing PRF.This differenee between the initiating PRF and the extinguishing PRF leads to a hysteresis phenomenon on the initiating and extinguishing boun daries.When the airflow velocity is in creased,both the initiating and extinguishing PRFs are increased and the differenee between the initiating PRF and the extinguishing PRF also increased.The hysteresis width between the initiating and extinguishing boundaries is enhanced.To explain these results,the physical processes involved with the seed particles and the mechanisms of forming discharge channels are discussed.展开更多
Water-based fire extinguishing agent is the main means to deal with smoldering fires.However,due to the hydrophobic properties of the particle surface,the porous medium channel provide resistance and slow down the ext...Water-based fire extinguishing agent is the main means to deal with smoldering fires.However,due to the hydrophobic properties of the particle surface,the porous medium channel provide resistance and slow down the extinguishing agent flow during the downward permeation process.To promote the liquid permeation process in such porous media,this work studied liquid imbibition process and analyzed the oscillating and attenuating process of liquid level in capillary channel by theoretical,experimental,and numerical methods.An empirical mathematical equation was proposed to describe the oscillating process,and the effects of the capillary diameter and contact angle parameters on the transportation process were analyzed.Based on this,the“relay-mode”was proposed to promote the liquid transportation forward.Finally,the transient simulation results of liquid permeation in coal stacks showed when the liquid flowed through the channel with changed diameter from large to small ones,the transportation distance was several times longer than that through the unidiameter ones.The trend of liquid“relay-mode”in capillaries can be used to promote the permeation in granular materials porous media stacks.The relevant results also provide new thoughts to develop the water-based fire extinguishing agents and then improve the firefighting efficiency of deep-seated fire in porous media stacks.展开更多
Various applications of volume dielectric barrier discharges(DBDs)with airflows have attracted significant attention such as in the fields of plasma medicine,surface modification,ozone synthesis,etc.In this work,the n...Various applications of volume dielectric barrier discharges(DBDs)with airflows have attracted significant attention such as in the fields of plasma medicine,surface modification,ozone synthesis,etc.In this work,the nonlinearity characteristics of DBDs in initiating and extinguishing boundaries with airflows are experimentally investigated.It is found that the difference between initiating pulse repetition frequencies(PRFs)and extinguishing PRFs is affected by the addition of airflows.A hysteresis region is produced between these two PRFs.A topological rule of Thom's classification theorem is proposed to investigate the hysteresis phenomenon of discharges with airflows.It is concluded that the discharge state is dependent on the operation route.The discharge state would transit from initiating to extinguishing,or in the opposite direction,while passing along a specific operation route.Based on the topological method,two nonlinear laws of discharge structure transition under the typical operation routes are predicted and verified in the discharge experiments.展开更多
Traditional lightning protection measures can not solve the problem of superimposed lightning strikes.This paper presents a compressing arc extinguishing lightning protection device,which can solve the problem of supe...Traditional lightning protection measures can not solve the problem of superimposed lightning strikes.This paper presents a compressing arc extinguishing lightning protection device,which can solve the problem of superimposed lightning strikes.This device can extinguish the power frequency continuous current arc quickly in 1-2 ms.It is far less than the response time of relay protection,which can avoid lightning trips and improve the reliability of power supply.The computer simulation and engineering practice show that the compressing arc extinguishing device has good protection effect on superimposed lightning strikes.展开更多
According to the physical and chemical characteristics of superfine powder extinguishing agent,three test methods are selected to measure the flow ability.By studying and comparing various test methods,apparatus and c...According to the physical and chemical characteristics of superfine powder extinguishing agent,three test methods are selected to measure the flow ability.By studying and comparing various test methods,apparatus and conditions,the optimum method and conditions to test flow property of superfine powder extinguishing agent are confirmed.展开更多
[Objective] This study was aimed to review the controlling experience of pine wilt disease in the past 25 years, explore the theories and methods of controlling pine wilt disease, and improve the scientific level of c...[Objective] This study was aimed to review the controlling experience of pine wilt disease in the past 25 years, explore the theories and methods of controlling pine wilt disease, and improve the scientific level of controlling techniques and the protection capacity of healthy pine trees. [Method] Eleven items of effects were used to refine the theory of clearing dead pine trees affected by pine wilt disease, namely, "1 priority", "2 objections", "3 principles", "4 measures", and "5 manage- ments". On the basis of comprehensive control and complete removal of the infect- ed pine trees, a variety of comprehensive and efficient controlling methods were developed to carry out targeted chemical ecology trapping, bionic pesticide killing and releasing natural enemies of Sclerodermus guani, Dastarcus helophoroides. High ef- ficient emamectin benzoate immune injection was developed to inject the healthy pine trees for prevention, so as to extinguish the pine wilt disease. [Result] The pine wilt disease dropped from the peak of 3.5 million dead trees with an infecting area of 28 273 hectares in 1999 to 0.068 million with an area of 4 333 hectares in 2012 gradually, reducing by 98.06% in number and 84.84% in area, respectively. On the basis of removal, Dastarcus helophoroides was also released, which could make the number of dead pines decrease more significantly than the control, and af- ter releasing for 5 consecutive years, the dead pine trees dropped to 0.511 plant/hm2 in 2012, with a mortality rate of 0.022 7%, which achieved the control effect, reaching extremely significant level. "Forest land removal+infected trees isolation+natural enemy release" could extinguish the pine wilt disease. The test of isolating 24 heaps of infected pine trees showed that there were 9 heaps of pine trees extinguished the pine wilt disease, which controlled the occurrence of pine wilt disease for 100%, accounting for 37.5% of the total, in which the number of those isolated using iron netting and nylon net were 4 for each, accounting for 88.9%, and there was one heap using polypropylene net, accounting for 11.1%. The invention of em- amectin benzoate immune injection laid the foundation for extinguishing pine wilt disease. The follow checking of the effects of emamectin benzoate immune injection on pine wilt disease found that the number of dead trees caused by pine wilt dis- ease decreased significantly after injecting, and became very small in October of the next year, and the disease was completely extinguished in the third year. [Conclusionl Pine wilt disease could be controlled and extinguished with positive control by using "comprehensive cleaning+industrialized removal", "comprehensive cleaning+ natural enemy release", "comprehensive cleaning+infected trees isolation+natural ene- my release" and "comprehensive cleaning+emamectin benzoate immune".展开更多
Two simplified models for predicting minimum extinguishing concentration(MEC) of ultrafine water mist(UFM)(<10 m) were developed based on limiting oxygen concentration(LOC) and combustion limit temperature(CLT),res...Two simplified models for predicting minimum extinguishing concentration(MEC) of ultrafine water mist(UFM)(<10 m) were developed based on limiting oxygen concentration(LOC) and combustion limit temperature(CLT),respectively.Experiment was conducted using a modified cup burner which can reduce the surface adsorption of UFM.Two typical liquid fuels,n-heptane and ethanol,were used in the experiment.Tests using the same scenario were repeated 20 times or 10 times according to the variance of extinguishing time.The average and the standard deviations of extinguishing time were used to evaluate the fire extinguishing performance of UFM.Experimental results agree well with the model based on LOC,and disagree with the model based on CLT.The disagreements were explained by analyzing flow behavior of UFM.It was concluded that the primary mechanism of fire extinguishment with UFM was oxygen dilution.展开更多
Based on the biological characteristics of Solenopsis invicta and the structural characteristics of its ant nest,a fast and efficient closed treatment device was developed.Compared with the simple chemical treatment c...Based on the biological characteristics of Solenopsis invicta and the structural characteristics of its ant nest,a fast and efficient closed treatment device was developed.Compared with the simple chemical treatment commonly used at present,the developed treatment device(the ant nest control cover)is a fast and efficient method to exterminate S.invicta in 7 d,featured by short course,quick results and good effect.展开更多
With principles of reliability, independence, practicality and economical effi- ciency, a set of intelligent fire alarm system based on AVRmega128 single chip microcomputer was designed to solve problems of fire alarm...With principles of reliability, independence, practicality and economical effi- ciency, a set of intelligent fire alarm system based on AVRmega128 single chip microcomputer was designed to solve problems of fire alarm system in many large- scale warehouses. Using advanced flame sensor, 485 bus communication, computer interactive software and related peripheral devices, this intelligent fire alarm system has functions of sound-light alarm and intelligent fire extinguishing. The human-com- puter interactive software was adopted for the remote control of the alarm main control panel through the 485 bus communication. This design of intelligent fire alarm system shows high reference and practical value to the development of intel- ligent alarm products with high integration and high reliability.展开更多
A study of the evolution of the pulse width in homogeneous dielectric barrier dis- charge at atmospheric pressure with helium as the working gas is reported by using a one- dimensional fluid model. In this paper, a ne...A study of the evolution of the pulse width in homogeneous dielectric barrier dis- charge at atmospheric pressure with helium as the working gas is reported by using a one- dimensional fluid model. In this paper, a new computational method is presented to estimate the pulse width through calculating the time interval between the breakdown voltage and the extinguishing voltage. The effects on the discharge characteristics of the applied voltage and exci- tation frequency are studied based on the computational data. The results of the simulation show that the pulse width is observed to be narrower and the time intervals between two consecutive current pulses decrease with increasing amplitude and excitation frequency, which indicates that the homogeneous discharge is susceptible to the filamentary mode. The simulation results support the conclusion that in order to restrain the transition from the glow mode to filamentary mode, the applied voltage and excitation frequency should be kept within an appropriate range.展开更多
Underground mine fire always exists since the mining activity was practiced.It poses a severe safety hazard to the mine workers and may also cause a tremendous economic loss to the mines.Methods for controlling and ex...Underground mine fire always exists since the mining activity was practiced.It poses a severe safety hazard to the mine workers and may also cause a tremendous economic loss to the mines.Methods for controlling and extinguishing fires in underground mine have long been studied and there have been significant improvements.In order to know clearly about the firefighting technology used,this paper summarizes most of the underground mine firefighting methods used in the United States the past 150 years.This paper describes not only the accepted firefighting theories,but also the technologies,both direct and indirect attacking,in accordance to regulations or codes,with special attention is given to the indirect attack method and its related technologies.Further research needed is also briefly discussed at the end of this paper.展开更多
Water mist technology provides efficient firefighting performance while there is still room for improvement. So varieties of additives have been studied in recent years both at home and abroad. The self-made additives...Water mist technology provides efficient firefighting performance while there is still room for improvement. So varieties of additives have been studied in recent years both at home and abroad. The self-made additives are used to compare the firefighting performance of diesel and heptane fire in open space. By adjusting the concentration of substance in the additives and conducting the experiment under the pressure of 0.3 MPa,0.5 MPa and 0.7 MPa,extinguish time and temperature are measured in the experiment. Through the experiments using different fuels,it can be found when the fuel is heptane that has a lower ignition point and a higher evaporation rate, the water mist additive can still significantly improve the firefighting performance. According to the data based on different concentrations of fluorinated surfactants,we find that fluorinated surfactants are the main substance to improve the performances by changing physical property of water mist. Optimal proportion of the additives for firefighting performance is found by experiment results.展开更多
Two models are defined for predicting the trajectory of a foam jet originating from a fire monitor(hydrant)and the related intensity drop point.An experimental framework is also defined and used accordingly to compare...Two models are defined for predicting the trajectory of a foam jet originating from a fire monitor(hydrant)and the related intensity drop point.An experimental framework is also defined and used accordingly to compare real-time data with the predictions of such models.This mixed theoretical-experimental approach is proven to be effective for the determination of otherwise unknown coefficients which take into account several important factors such as the operation pressure,the elevation angle and the nozzle diameter.It is shown that the mean absolute error is smaller than 20%.展开更多
In the analysis and research of few cases on the characteristics of vertical"burning"and spreading of fire in high-rise buildings in China and overseas,the mechanism of vertical spreading of fire along exter...In the analysis and research of few cases on the characteristics of vertical"burning"and spreading of fire in high-rise buildings in China and overseas,the mechanism of vertical spreading of fire along external wall is caused by hot pressing and wind pressure existing in high-rise buildings.The use of external wall combustible materials and near-window combustible items resulted in the formation of high temperature pyrotechnics and the burning of the external wall.Besides,due to the lack of fire-fighting measurements in high-rise building,it is recommended that the external wall of the high-rise building should be equipped with vertical fire-proof partitioning and non-combustible materials by setting up an automatic fire-fighting water curtain system along the vertical section of the external wall and above the indoor window.Therefore,the automatic sprinkler can be set up to prevent the fire from spreading vertically along the external wall of the building effectively.展开更多
基金supported by the New Energy Vehicle Power Battery Life Cycle Testing and Verification Public Service Platform Project[2022-235-224]the Beijing Science and Technology Planning Project[Z221100005222004]+1 种基金the Key Technologies Research and Development Program[2021YFB2012504]the Beijing Goldenbridge Project[ZZ2023002]。
文摘In this study,a detailed analysis of the combustion behaviors of the lithium iron phosphate(LFP)and lithium manganese oxide(LMO)batteries used in electric bicycles was conducted.This research included quantitative measurements of the combustion duration,flame height,combustion temperature,heat release rate,and total heat release.The results indicated that LMO batteries exhibited higher combustion temperatures of 600–700°C,flame heights of 70–75 cm,a significantly higher heat release rate of40.1 k W(12 Ah),and a total heat release of 1.04 MJ(12 Ah)compared to LFP batteries with the same capacity.Based on these experimental results,a normalized total heat release(NORTHR)parameter was proposed,demonstrating good universality for batteries with different capacities.Utilizing this parameter,quantitative calculations and optimization of the extinguishing agent dosage were conducted for fires involving these two types of batteries,and the method was validated by extinguishing fires for these two types of battery packs with water-based extinguishing fluids.
基金Central Finance Forestry Science and Technology Promotion Demonstration Project(H[2023]TG31).
文摘The paper summarizes the structure and water-absorbing mechanism,classification,and preparation method of polymer fire extinguishing gel,and prospects for its application in aerial firefighting,forest ground fire extinguishing,opening of firebreaks,and mitigating human casualties in forest fire extinguishing.
文摘Fire incidents in commercial vehicles pose significant risks to passengers, drivers, and cargo. Traditional fire extinguishing systems, while effective, may have limitations in terms of response time, coverage, and human intervention [1]. This study investigates the efficacy of a novel fire suppression technology—the Exploding Fire Extinguishing Ball (EFEB) —as an alternative and complementary fire safety solution for commercial vehicles. The research employs a multidisciplinary approach, encompassing engineering, materials science, fire safety, and human factors analysis. A systematic literature review establishes a comprehensive understanding of existing fire suppression technologies, including EFEBs. Subsequently, this study analyzes the unique features of EFEBs, such as automatic activation, as well as manual activation upon exposure to fire, and their potential to provide rapid, localized, and autonomous fire suppression. The study presents original experimental investigations to assess the performance and effectiveness of EFEBs in various fire scenarios representative of commercial vehicles. Experiments include controlled fires in confined spaces and dynamic simulations to emulate real-world fire incidents. Data on activation times, extinguishing capability, and coverage area are collected and analyzed to compare the efficacy of EFEBs with traditional fire extinguishing methods. Furthermore, this research shows the practical aspects of implementing EFEBs in commercial vehicles. A feasibility study examines the integration challenges, cost-benefit analysis, and potential regulatory implications. The study also addresses the impact of EFEBs on vehicle weight, stability, and overall safety. Human factors and user acceptance are crucial elements in adopting new safety technologies. Therefore, this research utilizes an experimental design to assess the performance and effectiveness of EFEBs in various fire scenarios representative of commercial vehicles. This dissertation presents original controlled experiments to emulate real-world fire incidents, including controlled fires in confined spaces and dynamic simulations. The experimental approach ensures rigorous evaluation and objective insights into EFEBs’ potential as an autonomous fire suppression system for commercial vehicles. This includes the perspectives of drivers, passengers, fleet operators, insurance agencies, and regulatory bodies. Factors influencing trust, perceived safety, and willingness to adopt EFEBs are analyzed to provide insights into the successful integration of this technology. The findings of this research will contribute to the knowledge of fire safety technology and expand the understanding of the applicability of EFEBs in commercial vehicles.
基金Project(51275102)supported by the National Natural Science Foundation of ChinaProject(159070220011)supported by the Science and Technology Innovative Research Programs Foundation of Harbin city,ChinaProject(HEUCF110702)supported by the Fundamental Research Funds for the Central Universities of China
文摘To solve the problem of sealing between the barrel and the rubber ring of shell body during an launching process of aerodynamic extinguishing cannon, a rubber sealing model with bionic dimpled characteristics was established based on the theory of bionic dimpled drag reduction and the principle of rubber sealing. In condition that the bionic dimpled characteristic diameters were 1, 2, 3, 4, and 5 mm, respectively, by numerical simulation, the influence of the installing compression of the rubber sealing ring on its surface stress and deformation was analyzed, and sealing performance of the rubber ring with different diameters of bionic dimpled was studied. The results show that the deformation of rubber ring appears prominent nonlinear characteristics when compression is increased from 1.5 mm to 2.5 ram. When the compression is 2.5 mm, the equivalent compression stress on the sealing areas of both sides of the rubber seal is greater than the working pressure of aerodynamic extinguishing cannon, which could meet the sealing requirement and would not cause leakage. So the rubber sealing ring with bionic dimpled surface possesses a good sealing characteristic and has no negative effect on the sealing of shell body; When the compression is 2.5 mm, the larger equivalent stress on the edge of sealing ring and the more even stress distribution in the high pressure area are generated due to the smaller compressive stress on the bionic dimple areas, which lays a foundation for the drag reduction characteristics of the shell body's rubber ring with bionic dimpled surface.
文摘The dielectric barrier discharge(DBD)is presently used in many fields,in eluding plasma medicine,surface modification,and ozone synthesis;the influe nee of airflow on the DBD is a widely investigated topic.In this work,a hysteresis characteristic on the initiating and extinguishing boundaries is observed in a nanosecond pulsed DBD,which is sensitive to the variation in the airflow velocities and pulse repetition frequencies(PRFs).It is found that,at a certain airflow velocity,the initiating PRF is higher than the extinguishing PRF.This differenee between the initiating PRF and the extinguishing PRF leads to a hysteresis phenomenon on the initiating and extinguishing boun daries.When the airflow velocity is in creased,both the initiating and extinguishing PRFs are increased and the differenee between the initiating PRF and the extinguishing PRF also increased.The hysteresis width between the initiating and extinguishing boundaries is enhanced.To explain these results,the physical processes involved with the seed particles and the mechanisms of forming discharge channels are discussed.
基金the funding support of National Natural Science Foundation of China (21978204)
文摘Water-based fire extinguishing agent is the main means to deal with smoldering fires.However,due to the hydrophobic properties of the particle surface,the porous medium channel provide resistance and slow down the extinguishing agent flow during the downward permeation process.To promote the liquid permeation process in such porous media,this work studied liquid imbibition process and analyzed the oscillating and attenuating process of liquid level in capillary channel by theoretical,experimental,and numerical methods.An empirical mathematical equation was proposed to describe the oscillating process,and the effects of the capillary diameter and contact angle parameters on the transportation process were analyzed.Based on this,the“relay-mode”was proposed to promote the liquid transportation forward.Finally,the transient simulation results of liquid permeation in coal stacks showed when the liquid flowed through the channel with changed diameter from large to small ones,the transportation distance was several times longer than that through the unidiameter ones.The trend of liquid“relay-mode”in capillaries can be used to promote the permeation in granular materials porous media stacks.The relevant results also provide new thoughts to develop the water-based fire extinguishing agents and then improve the firefighting efficiency of deep-seated fire in porous media stacks.
基金supported by National Natural Science Foundation of China(Nos.51676053 and 91741204)。
文摘Various applications of volume dielectric barrier discharges(DBDs)with airflows have attracted significant attention such as in the fields of plasma medicine,surface modification,ozone synthesis,etc.In this work,the nonlinearity characteristics of DBDs in initiating and extinguishing boundaries with airflows are experimentally investigated.It is found that the difference between initiating pulse repetition frequencies(PRFs)and extinguishing PRFs is affected by the addition of airflows.A hysteresis region is produced between these two PRFs.A topological rule of Thom's classification theorem is proposed to investigate the hysteresis phenomenon of discharges with airflows.It is concluded that the discharge state is dependent on the operation route.The discharge state would transit from initiating to extinguishing,or in the opposite direction,while passing along a specific operation route.Based on the topological method,two nonlinear laws of discharge structure transition under the typical operation routes are predicted and verified in the discharge experiments.
基金the National Natural Science Foundation of China(No.51467002)Special Projects for Innovation-driven Development(No.2018AA03001Y).
文摘Traditional lightning protection measures can not solve the problem of superimposed lightning strikes.This paper presents a compressing arc extinguishing lightning protection device,which can solve the problem of superimposed lightning strikes.This device can extinguish the power frequency continuous current arc quickly in 1-2 ms.It is far less than the response time of relay protection,which can avoid lightning trips and improve the reliability of power supply.The computer simulation and engineering practice show that the compressing arc extinguishing device has good protection effect on superimposed lightning strikes.
文摘According to the physical and chemical characteristics of superfine powder extinguishing agent,three test methods are selected to measure the flow ability.By studying and comparing various test methods,apparatus and conditions,the optimum method and conditions to test flow property of superfine powder extinguishing agent are confirmed.
基金Supported by the Scientific Research Project of National Level of YANG Zhongqi of Chinese Academy of Forestry(2012AA101503)~~
文摘[Objective] This study was aimed to review the controlling experience of pine wilt disease in the past 25 years, explore the theories and methods of controlling pine wilt disease, and improve the scientific level of controlling techniques and the protection capacity of healthy pine trees. [Method] Eleven items of effects were used to refine the theory of clearing dead pine trees affected by pine wilt disease, namely, "1 priority", "2 objections", "3 principles", "4 measures", and "5 manage- ments". On the basis of comprehensive control and complete removal of the infect- ed pine trees, a variety of comprehensive and efficient controlling methods were developed to carry out targeted chemical ecology trapping, bionic pesticide killing and releasing natural enemies of Sclerodermus guani, Dastarcus helophoroides. High ef- ficient emamectin benzoate immune injection was developed to inject the healthy pine trees for prevention, so as to extinguish the pine wilt disease. [Result] The pine wilt disease dropped from the peak of 3.5 million dead trees with an infecting area of 28 273 hectares in 1999 to 0.068 million with an area of 4 333 hectares in 2012 gradually, reducing by 98.06% in number and 84.84% in area, respectively. On the basis of removal, Dastarcus helophoroides was also released, which could make the number of dead pines decrease more significantly than the control, and af- ter releasing for 5 consecutive years, the dead pine trees dropped to 0.511 plant/hm2 in 2012, with a mortality rate of 0.022 7%, which achieved the control effect, reaching extremely significant level. "Forest land removal+infected trees isolation+natural enemy release" could extinguish the pine wilt disease. The test of isolating 24 heaps of infected pine trees showed that there were 9 heaps of pine trees extinguished the pine wilt disease, which controlled the occurrence of pine wilt disease for 100%, accounting for 37.5% of the total, in which the number of those isolated using iron netting and nylon net were 4 for each, accounting for 88.9%, and there was one heap using polypropylene net, accounting for 11.1%. The invention of em- amectin benzoate immune injection laid the foundation for extinguishing pine wilt disease. The follow checking of the effects of emamectin benzoate immune injection on pine wilt disease found that the number of dead trees caused by pine wilt dis- ease decreased significantly after injecting, and became very small in October of the next year, and the disease was completely extinguished in the third year. [Conclusionl Pine wilt disease could be controlled and extinguished with positive control by using "comprehensive cleaning+industrialized removal", "comprehensive cleaning+ natural enemy release", "comprehensive cleaning+infected trees isolation+natural ene- my release" and "comprehensive cleaning+emamectin benzoate immune".
基金supported by the National Natural Science Foundation of China (Grant No. 51028401)Jiangsu Province-Supporting Science and Technology Program (Project No. BE2010677)the Research Grant Council of the Hong Kong Administrative Region,China (Project No.CityU118909)
文摘Two simplified models for predicting minimum extinguishing concentration(MEC) of ultrafine water mist(UFM)(<10 m) were developed based on limiting oxygen concentration(LOC) and combustion limit temperature(CLT),respectively.Experiment was conducted using a modified cup burner which can reduce the surface adsorption of UFM.Two typical liquid fuels,n-heptane and ethanol,were used in the experiment.Tests using the same scenario were repeated 20 times or 10 times according to the variance of extinguishing time.The average and the standard deviations of extinguishing time were used to evaluate the fire extinguishing performance of UFM.Experimental results agree well with the model based on LOC,and disagree with the model based on CLT.The disagreements were explained by analyzing flow behavior of UFM.It was concluded that the primary mechanism of fire extinguishment with UFM was oxygen dilution.
基金Science and Technology Research Program of Xiamen Customs(2020XK08).
文摘Based on the biological characteristics of Solenopsis invicta and the structural characteristics of its ant nest,a fast and efficient closed treatment device was developed.Compared with the simple chemical treatment commonly used at present,the developed treatment device(the ant nest control cover)is a fast and efficient method to exterminate S.invicta in 7 d,featured by short course,quick results and good effect.
基金Supported by the National Natural Science Foundation of China(11275164)~~
文摘With principles of reliability, independence, practicality and economical effi- ciency, a set of intelligent fire alarm system based on AVRmega128 single chip microcomputer was designed to solve problems of fire alarm system in many large- scale warehouses. Using advanced flame sensor, 485 bus communication, computer interactive software and related peripheral devices, this intelligent fire alarm system has functions of sound-light alarm and intelligent fire extinguishing. The human-com- puter interactive software was adopted for the remote control of the alarm main control panel through the 485 bus communication. This design of intelligent fire alarm system shows high reference and practical value to the development of intel- ligent alarm products with high integration and high reliability.
基金supported by National Natural Science Foundation of China(No.51077089)
文摘A study of the evolution of the pulse width in homogeneous dielectric barrier dis- charge at atmospheric pressure with helium as the working gas is reported by using a one- dimensional fluid model. In this paper, a new computational method is presented to estimate the pulse width through calculating the time interval between the breakdown voltage and the extinguishing voltage. The effects on the discharge characteristics of the applied voltage and exci- tation frequency are studied based on the computational data. The results of the simulation show that the pulse width is observed to be narrower and the time intervals between two consecutive current pulses decrease with increasing amplitude and excitation frequency, which indicates that the homogeneous discharge is susceptible to the filamentary mode. The simulation results support the conclusion that in order to restrain the transition from the glow mode to filamentary mode, the applied voltage and excitation frequency should be kept within an appropriate range.
文摘Underground mine fire always exists since the mining activity was practiced.It poses a severe safety hazard to the mine workers and may also cause a tremendous economic loss to the mines.Methods for controlling and extinguishing fires in underground mine have long been studied and there have been significant improvements.In order to know clearly about the firefighting technology used,this paper summarizes most of the underground mine firefighting methods used in the United States the past 150 years.This paper describes not only the accepted firefighting theories,but also the technologies,both direct and indirect attacking,in accordance to regulations or codes,with special attention is given to the indirect attack method and its related technologies.Further research needed is also briefly discussed at the end of this paper.
基金Opening Fund of State Key Laboratory of Fire Science,University of Science and Technology of China(No.HZ2011-KF04)
文摘Water mist technology provides efficient firefighting performance while there is still room for improvement. So varieties of additives have been studied in recent years both at home and abroad. The self-made additives are used to compare the firefighting performance of diesel and heptane fire in open space. By adjusting the concentration of substance in the additives and conducting the experiment under the pressure of 0.3 MPa,0.5 MPa and 0.7 MPa,extinguish time and temperature are measured in the experiment. Through the experiments using different fuels,it can be found when the fuel is heptane that has a lower ignition point and a higher evaporation rate, the water mist additive can still significantly improve the firefighting performance. According to the data based on different concentrations of fluorinated surfactants,we find that fluorinated surfactants are the main substance to improve the performances by changing physical property of water mist. Optimal proportion of the additives for firefighting performance is found by experiment results.
基金the National Key Research and Development Plan(Grant No.2016YFC0801300).
文摘Two models are defined for predicting the trajectory of a foam jet originating from a fire monitor(hydrant)and the related intensity drop point.An experimental framework is also defined and used accordingly to compare real-time data with the predictions of such models.This mixed theoretical-experimental approach is proven to be effective for the determination of otherwise unknown coefficients which take into account several important factors such as the operation pressure,the elevation angle and the nozzle diameter.It is shown that the mean absolute error is smaller than 20%.
文摘In the analysis and research of few cases on the characteristics of vertical"burning"and spreading of fire in high-rise buildings in China and overseas,the mechanism of vertical spreading of fire along external wall is caused by hot pressing and wind pressure existing in high-rise buildings.The use of external wall combustible materials and near-window combustible items resulted in the formation of high temperature pyrotechnics and the burning of the external wall.Besides,due to the lack of fire-fighting measurements in high-rise building,it is recommended that the external wall of the high-rise building should be equipped with vertical fire-proof partitioning and non-combustible materials by setting up an automatic fire-fighting water curtain system along the vertical section of the external wall and above the indoor window.Therefore,the automatic sprinkler can be set up to prevent the fire from spreading vertically along the external wall of the building effectively.