For developing ultra-high voltage(UHV) AC power transmission systems,it is important to precisely estimate and to limit the radio interference(RI) level of power lines.Based on the stochastic characteristics in amplit...For developing ultra-high voltage(UHV) AC power transmission systems,it is important to precisely estimate and to limit the radio interference(RI) level of power lines.Based on the stochastic characteristics in amplitude and repetition rate of induced corona current,by using the probability theory and mathematical statistics,we establish a stochastic model for the wide-sense stationary random process of corona discharges.Then combining the stochastic model with model-propagation-analysis method,the RI levels under three-phase UHV AC transmission lines are calculated.The results of the calculation based on stochastic model method and International Council on Large Electric Systems(CIGRE) excitation function are compared with that based on semi-empirical method and some other excitation functions.The stochastic model based on different excitation functions is also adopted to simulate the RI levels under finite test lines with two opened terminations.The results indicate that with the same average maximum gradient on conductor surface and the same conductor type,the number of corona discharge per unit length is one of the main reasons that causes the difference between different excitation functions.It is also concluded that for a long test line,the effect of standing wave on RI field strength is negligible in the middle of the line,but obvious near both terminations: for a 10-km line,the maximum difference in RI field strength is 2.78 dB,between the peak value of the standing wave near the ends and the steady value near the middle of the line.展开更多
Long span ultra-high voltage(UHV) transmission lines have serious aeolian vibration problems. To control these vibrations,we improved the energy balance method in the following aspects:the wind power input,the conduct...Long span ultra-high voltage(UHV) transmission lines have serious aeolian vibration problems. To control these vibrations,we improved the energy balance method in the following aspects:the wind power input,the conductor self-damping,and the damper dissipated power. Meanwhile,we built a theoretical mechanical model of β wire dampers and derived energy dissipation calculation formulae. This permits the vibration energy dissipated by β wire dampers can be considered in the energy balance method. Then,we developed a computer program based on the improved energy balance method using Matlab,and analyzed UHV long span ground wires of the Han River long span project in P. R. China. The results show that the combination of β wire dampers and Stockbridge dampers can reduce vibration of UHV long span transmission lines,which provides a reference for research and construction of UHV engineering projects.展开更多
The impact of 500 kV transmission lines of Anqing power plant across the lake wetland reserve along the Yangtze River on the safety of the ecosystem was taken as the researched object.The power frequency electric fiel...The impact of 500 kV transmission lines of Anqing power plant across the lake wetland reserve along the Yangtze River on the safety of the ecosystem was taken as the researched object.The power frequency electric field intensity(PFEFI),power frequency magnetic field intensity(PFMFI),radio interference,construction noise,vegetation destruction and the influence on water quality were investigated and monitored,and the influences of PFEFI,PFMFI,radio interference and construction noise on wild animals,especially the habitats and migration of birds were mainly researched.The direct and indirect influences on the surrounding environment as well as plants and animals in sensitive areas were analyzed and predicted.The results firstly showed there existed a 182 400m^3 stereo-space(PFEFI>4kV/m)which made flying birds unsafe under the lowest height 11 mof the lines,which fills the gap in the research of this field.Finally,some operational protection countermeasures were put forward at the current technical level to achieve the win-win goal of economic development and natural protection.展开更多
This paper uses CT to gain the energy directly from the high-voltage transmission line, to address the problem of power supply for monitoring system in high voltage side of transmission line. The draw-out power coil c...This paper uses CT to gain the energy directly from the high-voltage transmission line, to address the problem of power supply for monitoring system in high voltage side of transmission line. The draw-out power coil can induce voltage from the transmission line, using single-chip microcomputer to analog and output PMW wave to control the charging module, provides a stable 3.4 V DC voltage to the load, and solve the problem of easy saturating of core. The power supply based on this kind of draw-out power coil has undergone the overall testing, and it is verified-showing that it can properly work in a non-saturated status within the current range of 50 - 1000 A, and provide a stable output. The equipment also design protection circuit to improve the reliability to avid the impacts of the impulse current or short-circuit current. It effectively solves the problem of power supply for On-line Monitoring System of Transmission.展开更多
Voltage source converter(VSC) based high voltage direct current(HVDC) transmission is most suited for the wind farm as it allows flexibility for reactive power control in multi-terminal transmission lines and transmit...Voltage source converter(VSC) based high voltage direct current(HVDC) transmission is most suited for the wind farm as it allows flexibility for reactive power control in multi-terminal transmission lines and transmits low power over smaller distance. In this work, a new method has been proposed to detect the fault, identify the section of faults and classify the pole of the fault in DC transmission lines fed from onshore wind farm. In the proposed scheme, voltage signal from rectifier end terminal is extracted with sampling frequency of 1 k Hz given as the input to the detection, classification and section discrimi-nation module. In this work, severe AC faults are also considered for section discrimination. Proposed method uses fuzzy inference system(FIS) to carry out all relaying task. The reach setting of the relay is 99.9% of the transmission line. Besides, the protection covers and discriminates the grounding fault with fault resistance up to 300 Ω.Considering the results of the proposed method, it can beused effectively in real power network.展开更多
Meteorological conditions during ice accretion on the 500 kV high voltage transmission lines and test cables are presented, together with a calculation of liquid water content (LWC). The data include meteorological ob...Meteorological conditions during ice accretion on the 500 kV high voltage transmission lines and test cables are presented, together with a calculation of liquid water content (LWC). The data include meteorological observations and real-time ice accretion on the transmission lines of the central China power grid, from 2008 to 2009 in Hubei Province. Also included are observations of ice thickness, microphysics of fog droplets, and other relevant data from a nearby automated weather station at Enshi radar station, from January to March 2009. Results show that temperature at Zhangen tower #307 was correlated with the temperature at Enshi radar station. The temperature on the surface of the high voltage transmission line was 2-4°C higher than ambient air temperature, although the temperatures were positively correlated. Ice formation temperature was about -2°C and ice shedding temperature was about -2 to -1°C on the high voltage transmission line, both of which were lower than the temperature threshold values on the test cable. Ice thickness was significantly affected by temperature variation when the ice was thin. The calculated LWC was correlated with observed LWC, although the calculated value was greater.展开更多
基金supported by Science and Technology Project of SGCC(SG1021)
文摘For developing ultra-high voltage(UHV) AC power transmission systems,it is important to precisely estimate and to limit the radio interference(RI) level of power lines.Based on the stochastic characteristics in amplitude and repetition rate of induced corona current,by using the probability theory and mathematical statistics,we establish a stochastic model for the wide-sense stationary random process of corona discharges.Then combining the stochastic model with model-propagation-analysis method,the RI levels under three-phase UHV AC transmission lines are calculated.The results of the calculation based on stochastic model method and International Council on Large Electric Systems(CIGRE) excitation function are compared with that based on semi-empirical method and some other excitation functions.The stochastic model based on different excitation functions is also adopted to simulate the RI levels under finite test lines with two opened terminations.The results indicate that with the same average maximum gradient on conductor surface and the same conductor type,the number of corona discharge per unit length is one of the main reasons that causes the difference between different excitation functions.It is also concluded that for a long test line,the effect of standing wave on RI field strength is negligible in the middle of the line,but obvious near both terminations: for a 10-km line,the maximum difference in RI field strength is 2.78 dB,between the peak value of the standing wave near the ends and the steady value near the middle of the line.
基金Funded by the Natural Science Foundation of China (No. 50878093).
文摘Long span ultra-high voltage(UHV) transmission lines have serious aeolian vibration problems. To control these vibrations,we improved the energy balance method in the following aspects:the wind power input,the conductor self-damping,and the damper dissipated power. Meanwhile,we built a theoretical mechanical model of β wire dampers and derived energy dissipation calculation formulae. This permits the vibration energy dissipated by β wire dampers can be considered in the energy balance method. Then,we developed a computer program based on the improved energy balance method using Matlab,and analyzed UHV long span ground wires of the Han River long span project in P. R. China. The results show that the combination of β wire dampers and Stockbridge dampers can reduce vibration of UHV long span transmission lines,which provides a reference for research and construction of UHV engineering projects.
基金Supported by the Provincial Governmental Foundation for Forestry of Anhui Province in 2013(2136203)
文摘The impact of 500 kV transmission lines of Anqing power plant across the lake wetland reserve along the Yangtze River on the safety of the ecosystem was taken as the researched object.The power frequency electric field intensity(PFEFI),power frequency magnetic field intensity(PFMFI),radio interference,construction noise,vegetation destruction and the influence on water quality were investigated and monitored,and the influences of PFEFI,PFMFI,radio interference and construction noise on wild animals,especially the habitats and migration of birds were mainly researched.The direct and indirect influences on the surrounding environment as well as plants and animals in sensitive areas were analyzed and predicted.The results firstly showed there existed a 182 400m^3 stereo-space(PFEFI>4kV/m)which made flying birds unsafe under the lowest height 11 mof the lines,which fills the gap in the research of this field.Finally,some operational protection countermeasures were put forward at the current technical level to achieve the win-win goal of economic development and natural protection.
文摘This paper uses CT to gain the energy directly from the high-voltage transmission line, to address the problem of power supply for monitoring system in high voltage side of transmission line. The draw-out power coil can induce voltage from the transmission line, using single-chip microcomputer to analog and output PMW wave to control the charging module, provides a stable 3.4 V DC voltage to the load, and solve the problem of easy saturating of core. The power supply based on this kind of draw-out power coil has undergone the overall testing, and it is verified-showing that it can properly work in a non-saturated status within the current range of 50 - 1000 A, and provide a stable output. The equipment also design protection circuit to improve the reliability to avid the impacts of the impulse current or short-circuit current. It effectively solves the problem of power supply for On-line Monitoring System of Transmission.
文摘Voltage source converter(VSC) based high voltage direct current(HVDC) transmission is most suited for the wind farm as it allows flexibility for reactive power control in multi-terminal transmission lines and transmits low power over smaller distance. In this work, a new method has been proposed to detect the fault, identify the section of faults and classify the pole of the fault in DC transmission lines fed from onshore wind farm. In the proposed scheme, voltage signal from rectifier end terminal is extracted with sampling frequency of 1 k Hz given as the input to the detection, classification and section discrimi-nation module. In this work, severe AC faults are also considered for section discrimination. Proposed method uses fuzzy inference system(FIS) to carry out all relaying task. The reach setting of the relay is 99.9% of the transmission line. Besides, the protection covers and discriminates the grounding fault with fault resistance up to 300 Ω.Considering the results of the proposed method, it can beused effectively in real power network.
基金supported by the National Key Technology R&D Program (2008BAC48B01)the National Natural Science Foundation of China (40775012)+1 种基金the Jiangsu Province Qinglan Project for Cloud Fog Precipitation and Aerosol Research Groupthe Priority Academic Program Development of Jiangsu Higher Education Institutions
文摘Meteorological conditions during ice accretion on the 500 kV high voltage transmission lines and test cables are presented, together with a calculation of liquid water content (LWC). The data include meteorological observations and real-time ice accretion on the transmission lines of the central China power grid, from 2008 to 2009 in Hubei Province. Also included are observations of ice thickness, microphysics of fog droplets, and other relevant data from a nearby automated weather station at Enshi radar station, from January to March 2009. Results show that temperature at Zhangen tower #307 was correlated with the temperature at Enshi radar station. The temperature on the surface of the high voltage transmission line was 2-4°C higher than ambient air temperature, although the temperatures were positively correlated. Ice formation temperature was about -2°C and ice shedding temperature was about -2 to -1°C on the high voltage transmission line, both of which were lower than the temperature threshold values on the test cable. Ice thickness was significantly affected by temperature variation when the ice was thin. The calculated LWC was correlated with observed LWC, although the calculated value was greater.