The correct method used in forest soil respiration measurement by Li-6400 is a premise of data quality control. According to the study in a larch plantation, collars should be inserted at 12 hours in advance to effici...The correct method used in forest soil respiration measurement by Li-6400 is a premise of data quality control. According to the study in a larch plantation, collars should be inserted at 12 hours in advance to efficiently reduce the influence of CO2 spring-out.Moreover, collar insertion depth substantially affected soil respiration measurement, i.e. when collar was shallowly inserted into soil,transversal gas diffusion and the CO2 re-spring-out caused by unstable collars in the measurement could lead to overestimating soil respiration rate; however, when collar was deeply inserted into soil, root respiration decline caused by root-cut and the most active respiratory of the surface soil separated by the inserted collars could lead to underestimating soil respiration rate. Furthermore, an error less than 5% could be guaranteed in typical sunny day if the target [CO2] was set to the mean value of ambient [CO2] in most time of the day, but it should be carefully set in early morning and late afternoon according to changing ambient [CO2]. This protocol of measurement is useful in real measurement.展开更多
基金National Natural Science Foundation of China (30300271),Program of Key Basic Research from Ministry of Science and Technology (2004CCA02700) and Sina-Japan cooperation project on larch forest study.
文摘The correct method used in forest soil respiration measurement by Li-6400 is a premise of data quality control. According to the study in a larch plantation, collars should be inserted at 12 hours in advance to efficiently reduce the influence of CO2 spring-out.Moreover, collar insertion depth substantially affected soil respiration measurement, i.e. when collar was shallowly inserted into soil,transversal gas diffusion and the CO2 re-spring-out caused by unstable collars in the measurement could lead to overestimating soil respiration rate; however, when collar was deeply inserted into soil, root respiration decline caused by root-cut and the most active respiratory of the surface soil separated by the inserted collars could lead to underestimating soil respiration rate. Furthermore, an error less than 5% could be guaranteed in typical sunny day if the target [CO2] was set to the mean value of ambient [CO2] in most time of the day, but it should be carefully set in early morning and late afternoon according to changing ambient [CO2]. This protocol of measurement is useful in real measurement.