期刊文献+
共找到8篇文章
< 1 >
每页显示 20 50 100
Multiple failure function based fragility curves for structures equipped with TMD 被引量:2
1
作者 Sina Bakhshinezhad Mohtasham Mohebbi 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2021年第2期471-482,共12页
This paper presents a procedure to develop fragility curves of structures equipped with TMD considering multiple failure functions.The failure criteria considered are maximum inter-story drift ratio as a safety criter... This paper presents a procedure to develop fragility curves of structures equipped with TMD considering multiple failure functions.The failure criteria considered are maximum inter-story drift ratio as a safety criterion,maximum absolute acceleration as a convenience criterion and TMD stroke length.The relationship between intensity measure and responses of the structure was assumed to follow the power-law model,and a regression analysis was used to estimate its properties.A nonlinear eight-story shear building subjected to near-fault earthquakes was used for the numerical studies.Fragility curves using multiple and single failure functions for an uncontrolled structure and a structure equipped with optimal TMDs were developed.Numerical analysis showed that using multiple failure functions led to increasing the fragility when compared with using the single failure function for both the uncontrolled and controlled structures.However,TMDs slightly reduced the seismic fragility and have the capability to improve the reliability of the structure.Also,it was found that the fragility was significantly influenced by the values of the capacity thresholds of both the acceleration of the structure and TMD stroke length,which should be selected by considering the target performance and application of the structure and control device. 展开更多
关键词 fragility curves multiple failure function passive control tuned mass dampers
下载PDF
Comprehensive Reliability Allocation Method for CNC Lathes Based on Cubic Transformed Functions of Failure Mode and Effects Analysis 被引量:8
2
作者 YANG Zhou ZHU Yunpeng +1 位作者 REN Hongrui ZHANG Yimin 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2015年第2期315-324,共10页
Reliability allocation of computerized numerical controlled(CNC)lathes is very important in industry.Traditional allocation methods only focus on high-failure rate components rather than moderate failure rate compon... Reliability allocation of computerized numerical controlled(CNC)lathes is very important in industry.Traditional allocation methods only focus on high-failure rate components rather than moderate failure rate components,which is not applicable in some conditions.Aiming at solving the problem of CNC lathes reliability allocating,a comprehensive reliability allocation method based on cubic transformed functions of failure modes and effects analysis(FMEA)is presented.Firstly,conventional reliability allocation methods are introduced.Then the limitations of direct combination of comprehensive allocation method with the exponential transformed FMEA method are investigated.Subsequently,a cubic transformed function is established in order to overcome these limitations.Properties of the new transformed functions are discussed by considering the failure severity and the failure occurrence.Designers can choose appropriate transform amplitudes according to their requirements.Finally,a CNC lathe and a spindle system are used as an example to verify the new allocation method.Seven criteria are considered to compare the results of the new method with traditional methods.The allocation results indicate that the new method is more flexible than traditional methods.By employing the new cubic transformed function,the method covers a wider range of problems in CNC reliability allocation without losing the advantages of traditional methods. 展开更多
关键词 CNC lathes reliability failure modes and effects analysis(FMEA) cubic transformed function comprehensive allocation
下载PDF
Fault-tolerant finite-time dynamical consensus of double-integrator multi-agent systems with partial agents subject to synchronous self-sensing function failure
3
作者 吴治海 谢林柏 《Chinese Physics B》 SCIE EI CAS CSCD 2022年第12期719-725,共7页
This paper investigates fault-tolerant finite-time dynamical consensus problems of double-integrator multi-agent systems(MASs)with partial agents subject to synchronous self-sensing function failure(SSFF).A strategy o... This paper investigates fault-tolerant finite-time dynamical consensus problems of double-integrator multi-agent systems(MASs)with partial agents subject to synchronous self-sensing function failure(SSFF).A strategy of recovering the connectivity of network topology among normal agents based on multi-hop communication and a fault-tolerant finitetime dynamical consensus protocol with time-varying gains are proposed to resist synchronous SSFF.It is proved that double-integrator MASs with partial agents subject to synchronous SSFF using the proposed strategy of network topology connectivity recovery and fault-tolerant finite-time dynamical consensus protocol with the proper time-varying gains can achieve finite-time dynamical consensus.Numerical simulations are given to illustrate the effectiveness of the theoretical results. 展开更多
关键词 multi-agent systems synchronous self-sensing function failure finite-time dynamical consensus network topology connectivity recovery
下载PDF
Analysis of functional failure mode of commercial deep sub-micron SRAM induced by total dose irradiation
4
作者 郑齐文 崔江维 +5 位作者 周航 余德昭 余学峰 陆妩 郭旗 任迪远 《Chinese Physics B》 SCIE EI CAS CSCD 2015年第10期380-385,共6页
Functional failure mode of commercial deep sub-micron static random access memory(SRAM) induced by total dose irradiation is experimentally analyzed and verified by circuit simulation. We extensively characterize th... Functional failure mode of commercial deep sub-micron static random access memory(SRAM) induced by total dose irradiation is experimentally analyzed and verified by circuit simulation. We extensively characterize the functional failure mode of the device by testing its electrical parameters and function with test patterns covering different functional failure modes. Experimental results reveal that the functional failure mode of the device is a temporary function interruption caused by peripheral circuits being sensitive to the standby current rising. By including radiation-induced threshold shift and off-state leakage current in memory cell transistors, we simulate the influence of radiation on the functionality of the memory cell. Simulation results reveal that the memory cell is tolerant to irradiation due to its high stability, which agrees with our experimental result. 展开更多
关键词 total dose irradiation static random access memory functional failure mode
下载PDF
Echocardiographic Evaluation of Cardiac Dyssynchrony in Patients with Congestive Heart Failure 被引量:1
5
作者 秦川 张丽 +5 位作者 章子铭 王斌 叶舟 王勇 Navin C.Nanda 谢明星 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 2016年第3期434-441,共8页
The present study investigated the application of echocardiography to evaluation of cardiac dyssynchrony in patients with congestive heart failure(CHF). A total of 348 consecutive CHF patients who were admitted for ... The present study investigated the application of echocardiography to evaluation of cardiac dyssynchrony in patients with congestive heart failure(CHF). A total of 348 consecutive CHF patients who were admitted for cardiac resynchronization(CRT) and presented with low ejection fraction(EF) and wide QRS duration were enrolled in this study, along with 388 healthy individuals. Dyssynchrony was assessed based on filling time ratio(FT/RR), left ventricular pre-ejection delay(PED), interventricular mechanical delay(IVMD), longitudinal opposing wall delay(LOWD) and radial septal to posterior wall delay(RSPWD). Response to CRT was defined as a ≥15% increase in EF. The results showed that FT/RR was decreased while PED, IVMD, LOWD and RSPWD were increased in the CHF group compared with the control group(P〈0.01). In the CHF group, FT/RR was negatively correlated with the QRS duration, LV end-diastolic diameter(LVESd), LV end-diastolic volume(LVEDV) and LV end-systolic volume(LVESV)(P〈0.01), but positively with the LVEF(P〈0.01). Additionally, PED, IVMD, LOWD and RSPWD were positively correlated with the QRS duration, LVESd, LVEDV and LVESV(P〈0.01), but negatively with the LVEF(P〈0.01). The CHF group was divided into three subgroups according to the varying degrees of LVEF. FT/RR decreased successively from the LVEF-1 group to the LVEF-2 group to the LVEF-3 group, while the PED, IVMD, LOWD and RSPWD successively increased in the same order(P〈0.01). The CHF group was divided into three subgroups according to the varying degrees of QRS duration, and FT/RR decreased successively in a sequence from the QRS-1 group to the QRS-2 group to the QRS-3 group, while the PED, IVMD, LOWD and RSPWD successively increased in the same order(P〈0.01). Speckle tracking radial dyssynchrony ≥130 ms was predictive of an EF response in patients in QRS-1 group(78% sensitivity, 83% specificity), those in QRS-2 group(83% sensitivity, 77% specificity) and in QRS-3 group(89% sensitivity, 79% specificity). In conclusion, echocardiography is a convenient and sensitive method for evaluating cardiac dyssynchrony in patients with CHF. 展开更多
关键词 echocardiography congestive heart failure cardiac dyssynchrony left ventricular function
下载PDF
Optimal layout model of feeder automation equipment oriented to the type of fault detection and local action
6
作者 Ruizhi Chen Xihong Li Yanbo Chen 《Protection and Control of Modern Power Systems》 SCIE EI 2023年第1期15-29,共15页
In feeder automation transformation there are difficulties in equipment and location selection.To help with this,an optimal layout model of feeder automation equipment oriented to the type of fault detection and local... In feeder automation transformation there are difficulties in equipment and location selection.To help with this,an optimal layout model of feeder automation equipment oriented to the type of fault detection and local action is pro-posed.It analyzes the coordination relationship of the three most common types of automation equipment,i.e.,fault indicator,over-current trip switch and non-voltage trip switch in the fault handling process,and the explicit expres-sions of power outage time caused by a fault on different layouts of the above three types of equipment are given.Given constraints of power supply reliability and the goal of minimizing the sum of equipment-related capital invest-ment and power interruption cost,a mixed-integer quadratic programming model for optimal layout is established,in which the functional failure probability of equipment is linearized using the 3δprinciple in statistics.Finally,the basic characteristics of the proposed model are illustrated by different scenarios on the IEEE RBTS-BUS6 system.It can not only take into account fault location and fault isolation to enhance user power consumption perception,but also can guide precise investment to improve the operational quality and efficiency of a power company. 展开更多
关键词 Feeder automation Equipment layout optimization Power outage time Explicit expression Mixed integer quadratic programming model functional failure probability of equipment
原文传递
Two cases of combined liver-kidney transplantation 被引量:2
7
作者 郑树森 梁廷波 +3 位作者 陈江华 黄东胜 张珉 王逸民 《Chinese Medical Journal》 SCIE CAS CSCD 2000年第12期48-51,共4页
To report the clinical experiences of simultaneous hepatorenal transplantation Methods We performed simultaneous hepatorenal transplantation in one patient with liver cirrhosis of hepatitis B and uremia of chronic n... To report the clinical experiences of simultaneous hepatorenal transplantation Methods We performed simultaneous hepatorenal transplantation in one patient with liver cirrhosis of hepatitis B and uremia of chronic nephritis on February 1, 1999 and one patient with liver cirrhosis of hepatitis B complicated by hepatorenal syndrome on March 12,1999 The donors were heart arrest cases Rapid multiple organ harvesting techniques and UW solution infusion in situ were used Liver and kidney transplantation were orthotopic and ordinary methods, respectively Immunosuppressive drugs consisted of cyclosporine, Cellcept, ALG and cortstco steroids Lamividine was used on day 50 and day 40 postoperation, respectively Results Both transplanted organs rapidly achieved normal function postoperation and the patients recovered well but suffered mild kidney rejection day 110 postoperation in No 1 patient In No 2 patient, acute renal function failure, mental symptoms, muscle spasm, cerebral artery thrombosis, inhalation pneumonia and chronic liver graft rejection ensured sequentially but were controlled The patients have survived for more than nine and eight months, respectively, with normal life quality Conclusions Combined hepatorenal transplant is a radical treatment method for liver and kidney function failure and requires more comprehensive techniques than isolated single organ transplantation Preventing the recurrence of hepatitis B by oral lamividine may be a key to long term survival 展开更多
关键词 liver function failure · uremia · liver transplant · kidney transplant
原文传递
A novel testability model for health management of heading attitude system 被引量:2
8
作者 Liu Guanjun Yang Shuming +1 位作者 Qiu Jing Yang Peng 《Chinese Journal of Aeronautics》 SCIE EI CAS CSCD 2013年第1期201-208,共8页
Prognostics and health management (PHM) is very important to guarantee the reliability and safety of aerospace systems, and sensing and test are the precondition of PHM. Integrating design for testability into early... Prognostics and health management (PHM) is very important to guarantee the reliability and safety of aerospace systems, and sensing and test are the precondition of PHM. Integrating design for testability into early design stage of system early design stage is deemed as a fundamental way to improve PHM performance, and testability model is the base of testability analysis and design. This paper discusses a hierarchical model-based approach to testability modeling and analysis for heading attitude system health management. Quantified directed graph, of which the nodes represent components and tests and the directed edges represent fault propagation paths, is used to describe fault-test dependency, and quantitative testability information is assigned to nodes and directed edges. The fault dependencies between nodes can be obtained by functional fault analysis methodology that captures the physical architecture and material flows such as energy, heat, data, and so on. By incorporating physics of failure models into component, the dynamic process of a failing or degrading component can be projected onto system behavior, i.e., system symptoms. Then, the analysis of extended failure modes, mechanisms and effects is utilized to construct fault evolution-test dependency. Using this integrated model, the designers and system analysts can assess the test suite's fault detectability, fault isolability and fault predictability. And heading attitude system application results show that the proposed model can support testability analysis and design for PHM very well. 展开更多
关键词 Fault evolution functional fault analysis Physics of failure model Prognostics and health management Quantified directed graph Testability analysis
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部