期刊文献+
共找到4篇文章
< 1 >
每页显示 20 50 100
Application of Luxol Fast Blue staining in locating the corticospinal tract in adult rats 被引量:1
1
作者 Su Liu1, Guangyu Shen1, Guangming Lü2, Xiaosong Gu3 1Department of Rehabilitation Medicine, Affiliated Hospital of Nantong University, Nantong 226001, Jiangsu Province, China 2Department of Human Anatomy, Nantong University, Nantong 226001, Jiangsu Province, China 3Jiangsu Key Laboratory of Nerve Regeneration, Nantong 226001, Jiangsu Province, China 《Neural Regeneration Research》 SCIE CAS CSCD 2006年第7期642-644,共3页
BACKGROUND: There are many methods for myelin staining, mordant, or oil-soluble dye or the special reaction of osmic acid with lipoid is used according to different principles. The commonly used methods are classic We... BACKGROUND: There are many methods for myelin staining, mordant, or oil-soluble dye or the special reaction of osmic acid with lipoid is used according to different principles. The commonly used methods are classic Well staining, classic lithium carbonate-haematine staining, fast green staining, silver staining, etc. Luxol Fast Blue can brightly stain myelin sheath, and has certain specificity. The background can be very clean if there is proper differentiation, whereas Luxol Fast Blue is cheap and convenient to operate, thus it is an ideal staining reagent for routine myelin sheath. OBJECTIVE: To show the corticospinal tract of normal adult rats with Luxol Fast Blue staining method. DESIGN: A repetitive measurement design. SETTINGS: Institute of Nuerobiology, Nantong University; Department of Rehabilitation Medicine, Affiliated Hospital of Nantong University. MATERIALS: Six healthy adult male SD rats of clean degree, weighing averagely 300 g, were provided by the experimental animal center of Nantong University. 1 g/L Luxol Fast Blue solution was provided by Sigma Company; Leica CM1900 cryostat microtome by Leica Company; Leica DMR microscope by Leica Company. METHODS: The experiment was carried out in the Staff Room of Human Anatomy, Nantong University in May 2005. The rats were given intraperitoneal injection of combined anesthetic (2 mL/kg), then the chest was open for perfusing saline and phosphate buffer containing formamint via heart. Brain and spinal cord were removed after 1 hour then fixed, then changed to phosphate buffer (pH 7.4) containing 300 g/L saccharu at 4 ℃, and stayed overnight, tissue blocks at pyramid, decussation of pyramid and cervical, thoracic, lumbar and sacral segments of spinal cord were removed to prepare continuous horizontal frozen sections (30 μm) after sedimentation, the sections were dried at room temperature. The corticospinal tract of normal adult rats were shown with Luxol Fast Blue staining method, and observed under Leica DMR microscope. MAIN OUTCOME MEASURES: Positive fibers in Luxol Fast Blue staining. RESULTS: After the Luxol Fast Blue staining, the labeled myelinated nerve fibers were bright blue. They located in the pyramid, decussation of pyramid and the ventral part of posterior funiculus in cervical, thoracic, lumbar and sacral segments of spinal cord. CONCLUSION: Luxol Fast Blue staining method may manifest the distribution of corticospinal tract with clear distinct in adult rats. 展开更多
关键词 application of Luxol fast Blue staining in locating the corticospinal tract in adult rats
下载PDF
Fast Measurement of Dielectric Conductivity for Space Application by Surface Potential Decay Method 被引量:1
2
作者 全荣辉 周凯 +2 位作者 方美华 池卫英 张振龙 《Chinese Physics Letters》 SCIE CAS CSCD 2017年第6期104-106,共3页
Surface potential decay of polymers for electrical insulation can help to determine the dark conductivity for spacecraft charging analysis. Due to the existence of radiation-induced conductivity, it decays fast in the... Surface potential decay of polymers for electrical insulation can help to determine the dark conductivity for spacecraft charging analysis. Due to the existence of radiation-induced conductivity, it decays fast in the first few hours after irradiation and exponentially slowly for the remaining time. The measurement of dark conductivity with this method usually takes the slow part and needs a couple of days. Integrating the Fowler formula into the deep dielectric charging equations, we obtain a new expression for the fast decay part. The experimental data of different materials, dose rates and temperatures are fitted by the new expression. Both the dark conductivity and the radiation-induced conductivity are derived and compared with other methods. The result shows a good estimation of dark conductivity and radiation-induced conductivity in high-resistivity polymers, which enables a fast measurement of dielectric conductivity within about 600 rain after irradiation. 展开更多
关键词 fast Measurement of Dielectric Conductivity for Space application by Surface Potential Decay Method
下载PDF
APPLICATIONS OF FAST SIMULATED ANNEALING IN NEURAL NETWORKS
3
作者 Yi Lin CAO Qing Zhang +1 位作者 LU Shu Ting YANG(Department of Chemistry, Henan Normal University, Xinxiang, 453002)Hong Lin LIU(Shanghai Institute of Mentallurgy, Academia Sinica, Shanghai, 200050) 《Chinese Chemical Letters》 SCIE CAS CSCD 1996年第4期365-366,共2页
Fast simulated annealing is implemented into the learning process of neural network to replace the traditional back-propagation algorithm. The new procedure exhibits performance fast in learning and accurate in predic... Fast simulated annealing is implemented into the learning process of neural network to replace the traditional back-propagation algorithm. The new procedure exhibits performance fast in learning and accurate in prediction compared to the traditional neural networks. Two numerical data sets were used to illustrate its use in chemistry. 展开更多
关键词 fast applicationS OF fast SIMULATED ANNEALING IN NEURAL NETWORKS
下载PDF
Simplified Fast Transient Control in Coolerless Pump EDFA for Metro Applications
4
作者 J.J. Pan Wei Wang +4 位作者 Xiangdong Qiu Mingjie Zhang Kejian Guan Joy Jiang Jonathan Zhang 《光学学报》 EI CAS CSCD 北大核心 2003年第S1期-,共2页
A novel optical transient suppression technique to dramatically reduce gain variation of EDFA with un-cooled pump is demonstrated experimentally, showing excellent performance of 50us transient time with no more than ... A novel optical transient suppression technique to dramatically reduce gain variation of EDFA with un-cooled pump is demonstrated experimentally, showing excellent performance of 50us transient time with no more than 0.5dB excursion and 0.25dB offset. 展开更多
关键词 EDFA of Simplified fast Transient Control in Coolerless Pump EDFA for Metro applications for in
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部