期刊文献+
共找到38篇文章
< 1 2 >
每页显示 20 50 100
Actuator and sensor fault isolation in a class of nonlinear dynamical systems
1
作者 Hamed Tirandaz Christodoulos Keliris Marios M.Polycarpou 《Journal of Automation and Intelligence》 2024年第2期57-72,共16页
Fault isolation in dynamical systems is a challenging task due to modeling uncertainty and measurement noise,interactive effects of multiple faults and fault propagation.This paper proposes a unified approach for isol... Fault isolation in dynamical systems is a challenging task due to modeling uncertainty and measurement noise,interactive effects of multiple faults and fault propagation.This paper proposes a unified approach for isolation of multiple actuator or sensor faults in a class of nonlinear uncertain dynamical systems.Actuator and sensor fault isolation are accomplished in two independent modules,that monitor the system and are able to isolate the potential faulty actuator(s)or sensor(s).For the sensor fault isolation(SFI)case,a module is designed which monitors the system and utilizes an adaptive isolation threshold on the output residuals computed via a nonlinear estimation scheme that allows the isolation of single/multiple faulty sensor(s).For the actuator fault isolation(AFI)case,a second module is designed,which utilizes a learning-based scheme for adaptive approximation of faulty actuator(s)and,based on a reasoning decision logic and suitably designed AFI thresholds,the faulty actuator(s)set can be determined.The effectiveness of the proposed fault isolation approach developed in this paper is demonstrated through a simulation example. 展开更多
关键词 Actuator and sensor fault isolation Adaptive approximation Observer-based fault diagnosis Reasoning-based decision logic
下载PDF
Fault isolation of air handling unit based on neural network 被引量:2
2
作者 杜志敏 晋欣桥 +1 位作者 杨学宾 范波 《Journal of Southeast University(English Edition)》 EI CAS 2010年第2期355-358,共4页
Aiming at various faults in an air conditioning system,the fault characteristics are analyzed.The influence of the faults on the energy consumption and thermal comfort of the system are also discussed.The simulation r... Aiming at various faults in an air conditioning system,the fault characteristics are analyzed.The influence of the faults on the energy consumption and thermal comfort of the system are also discussed.The simulation results show that the measurement faults of the supply air temperature can lead to the increase in energy consumption.According to the fault characteristics,a data-driven method based on a neural network is presented to detect and diagnose the faults of air handling units.First,the historical data are selected to train the neural network so that it can recognize and predict the operation of the system.Then,the faults can be diagnosed by calculating the relative errors denoting the difference between the measuring values and the prediction outputs.Finally,the fault diagnosis strategy using the neural network is validated by using a simulator based on the TRNSYS platform.The results show that the neural network can diagnose different faults of the temperature,the flow rate and the pressure sensors in the air conditioning system. 展开更多
关键词 air handling unit fault characteristics fault isolation neural network
下载PDF
Fault Isolation by Partial Dynamic Principal Component Analysis in Dynamic Process 被引量:18
3
作者 李荣雨 荣冈 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2006年第4期486-493,共8页
Principal component analysis (PCA) is a useful tool in process fault detection, but offers little support on fault isolation. In this article, structured residual with strong isolation property is introduced. Althou... Principal component analysis (PCA) is a useful tool in process fault detection, but offers little support on fault isolation. In this article, structured residual with strong isolation property is introduced. Although it is easy to get the residual by transformation matrix in static process, unfortunately, it becomes hard in dynamic process under control loop. Therefore, partial dynamic PCA(PDPCA) is proposed to obtain structured residual and enhance the isolation ability of dynamic process monitoring, and a compound statistic is introduced to resolve the problem resulting from independent variables in every variable subset. Simulations on continuous stirred tank reactor (CSTR) show the effectiveness of the proposed method. 展开更多
关键词 fault isolation structured residual dynamic principal component analysis partial principal componentanalysis
下载PDF
A FAULT ISOLATION EXPERT SYSTEM FOR ENGINE INDICATION AND CREW ALERTING SYSTEM
4
作者 杨忠 刘正埙 +1 位作者 左洪福 吴惠祥 《Transactions of Nanjing University of Aeronautics and Astronautics》 EI 1998年第1期48-52,共5页
This paper is devoted to develop an expert system to manage the fault isolation and maintenance knowledge of the engine indication and crew alerting system (EICAS). The object oriented programming (OOP) technique and... This paper is devoted to develop an expert system to manage the fault isolation and maintenance knowledge of the engine indication and crew alerting system (EICAS). The object oriented programming (OOP) technique and the microsoft foundation class (MFC) are applied to set up a frame decision tree (FDT) which incorporates the expert system′s knowledge base, inference engine and user interface. Once a fault symptom indicated by the EICAS is input, by inferring step by step, the expert system can locate it in the engine and provide some homologous constructive maintenance advice. 展开更多
关键词 expert system object oriented ENGINE fault isolation
下载PDF
A Multi-level Approach for Complex Fault Isolation Based on Structured Residuals 被引量:4
5
作者 叶鲁彬 石向荣 梁军 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2011年第3期462-472,共11页
In industrial processes,there exist faults that have complex effect on process variables.Complex and simple faults are defined according to their effect dimensions.The conventional approaches based on structured resid... In industrial processes,there exist faults that have complex effect on process variables.Complex and simple faults are defined according to their effect dimensions.The conventional approaches based on structured residuals cannot isolate complex faults.This paper presents a multi-level strategy for complex fault isolation.An extraction procedure is employed to reduce the complex faults to simple ones and assign them to several levels.On each level,faults are isolated by their different responses in the structured residuals.Each residual is obtained insensitive to one fault but more sensitive to others.The faults on different levels are verified to have different residual responses and will not be confused.An entire incidence matrix containing residual response characteristics of all faults is obtained,based on which faults can be isolated.The proposed method is applied in the Tennessee Eastman process example,and the effectiveness and advantage are demonstrated. 展开更多
关键词 MULTI-LEVEL structured residuals principal component analysis complex fault isolation Tennessee Eastman process
下载PDF
Improved RBF network application in analog circuit fault isolation 被引量:1
6
作者 禹航 肖明清 赵鑫 《Journal of Measurement Science and Instrumentation》 CAS 2012年第1期70-74,共5页
One kind of steepest descent incremental projection learning algorithm for improving the training of radial basis function(RBF)neural network is proposed,which is applied to analog circuit fault isolation.This algorit... One kind of steepest descent incremental projection learning algorithm for improving the training of radial basis function(RBF)neural network is proposed,which is applied to analog circuit fault isolation.This algorithm simplified the structure of network through optimum output layer coefficient with incremental projection learning(IPL)algorithm,and adjusted the parameters of the neural activation function to control the network scale and improve the network approximation ability.Compared to the traditional algorithm,the improved algorithm has quicker convergence rate and higher isolation precision.Simulation results show that this improved RBF network has much better performance,which can be used in analog circuit fault isolation field. 展开更多
关键词 analog circuit fault isolation RBF network IPL algorithm steepest descent algorithm
下载PDF
Fast Fault Isolation and Restoration of Looped MV Network
7
作者 马士聪 徐丙垠 高厚磊 《Transactions of Tianjin University》 EI CAS 2008年第2期148-152,共5页
A new fault isolation and restoration technique employing local Ethemet network for the looped MV circuit is presented. It can isolate all short circuit faults in the loop within 300 ms and restore the supply of healt... A new fault isolation and restoration technique employing local Ethemet network for the looped MV circuit is presented. It can isolate all short circuit faults in the loop within 300 ms and restore the supply of healthy sections in less than 1.2 s. A reliable fault location method of isolating the single phase-to-ground fault (SPGF) in the non-effectively earthed network, which makes use of the fault generated transient signals, is also proposed. And the method locates the SPGF by examining transient zero-mode current correlation, which is not influenced by the neutral grounding mode and need no additional device. Laboratory test and simulation results show the proposed techniques are feasible, and significantly improve the supply reliability. 展开更多
关键词 fault isolation and restoration non-effectively earthed neutral system transient zero-mode current optical fibre Ethernet
下载PDF
Study of Test Flow Optimization Method in Radar Fault Isolation
8
作者 Zhi-Hua Li Qing Zheng Xiao-An Song 《Journal of Electronic Science and Technology of China》 2009年第4期395-398,共4页
In order to optimize test flow after the default flow is modified by a tester, a new software framework for the radar fault isolation is illustrated. This framework separates all mapping algorithms from test flows so ... In order to optimize test flow after the default flow is modified by a tester, a new software framework for the radar fault isolation is illustrated. This framework separates all mapping algorithms from test flows so as to modify flow and to insert mapping algorithm dynamically in testing process. Based on this framework, a kind of optimization method of test flow is proposed and studied. By defining an objective function, we can evaluate all candidate test flows so as to get an optimized flow. An example explains how to search the flow from candidate flows. 展开更多
关键词 Automatic test fault isolation optimi- zation RADAR software framework.
下载PDF
Adaptive partitioning PCA model for improving fault detection and isolation 被引量:6
9
作者 刘康玲 金鑫 +1 位作者 费正顺 梁军 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2015年第6期981-991,共11页
In chemical process, a large number of measured and manipulated variables are highly correlated. Principal component analysis(PCA) is widely applied as a dimension reduction technique for capturing strong correlation ... In chemical process, a large number of measured and manipulated variables are highly correlated. Principal component analysis(PCA) is widely applied as a dimension reduction technique for capturing strong correlation underlying in the process measurements. However, it is difficult for PCA based fault detection results to be interpreted physically and to provide support for isolation. Some approaches incorporating process knowledge are developed, but the information is always shortage and deficient in practice. Therefore, this work proposes an adaptive partitioning PCA algorithm entirely based on operation data. The process feature space is partitioned into several sub-feature spaces. Constructed sub-block models can not only reflect the local behavior of process change, namely to grasp the intrinsic local information underlying the process changes, but also improve the fault detection and isolation through the combination of local fault detection results and reduction of smearing effect.The method is demonstrated in TE process, and the results show that the new method is much better in fault detection and isolation compared to conventional PCA method. 展开更多
关键词 Adaptive partitioning fault detection fault isolation Principal component analysis
下载PDF
ASCS Online Fault Detection and Isolation Based on an Improved MPCA 被引量:3
10
作者 PENG Jianxin LIU Haiou +2 位作者 HU Yuhui XI Junqiang CHEN Huiyan 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2014年第5期1047-1056,共10页
Multi-way principal component analysis(MPCA)has received considerable attention and been widely used in process monitoring.A traditional MPCA algorithm unfolds multiple batches of historical data into a two-dimensio... Multi-way principal component analysis(MPCA)has received considerable attention and been widely used in process monitoring.A traditional MPCA algorithm unfolds multiple batches of historical data into a two-dimensional matrix and cut the matrix along the time axis to form subspaces.However,low efficiency of subspaces and difficult fault isolation are the common disadvantages for the principal component model.This paper presents a new subspace construction method based on kernel density estimation function that can effectively reduce the storage amount of the subspace information.The MPCA model and the knowledge base are built based on the new subspace.Then,fault detection and isolation with the squared prediction error(SPE)statistic and the Hotelling(T2)statistic are also realized in process monitoring.When a fault occurs,fault isolation based on the SPE statistic is achieved by residual contribution analysis of different variables.For fault isolation of subspace based on the T2 statistic,the relationship between the statistic indicator and state variables is constructed,and the constraint conditions are presented to check the validity of fault isolation.Then,to improve the robustness of fault isolation to unexpected disturbances,the statistic method is adopted to set the relation between single subspace and multiple subspaces to increase the corrective rate of fault isolation.Finally fault detection and isolation based on the improved MPCA is used to monitor the automatic shift control system(ASCS)to prove the correctness and effectiveness of the algorithm.The research proposes a new subspace construction method to reduce the required storage capacity and to prove the robustness of the principal component model,and sets the relationship between the state variables and fault detection indicators for fault isolation. 展开更多
关键词 multi-way principal component analysis(MPCA) fault detection fault isolation automatic shift control system
下载PDF
Robust Nonlinear Analytic Redundancy for Fault Detection and Isolation in Mobile Robot 被引量:2
11
作者 Bibhrajit Halder Nilanjan Sarkar 《International Journal of Automation and computing》 EI 2007年第2期177-182,共6页
A robust nonlinear analytical redundancy (RNLAR) technique is presented to detect and isolate actuator and sensor faults in a mobile robot. Both model-plant-mismatch (MPM) and process disturbance are considered du... A robust nonlinear analytical redundancy (RNLAR) technique is presented to detect and isolate actuator and sensor faults in a mobile robot. Both model-plant-mismatch (MPM) and process disturbance are considered during fault detection. The RNLAR is used to design primary residual vectors (PRV), which are highly sensitive to the faults and less sensitive to MPM and process disturbance, for sensor and actuator fault detection. The PRVs are then transformed into a set of structured residual vectors (SRV) for fault isolation. Experimental results on a Pioneer 3-DX mobile robot are presented to justify the effectiveness of the RNLAR scheme. 展开更多
关键词 fault detection fault isolation nonlinear systems ROBUSTNESS uncertainty.
下载PDF
Short-circuit fault analysis and isolation strategy for matrix converters
12
作者 王莉娜 L.De Lillo +2 位作者 C.Brunson L.Empringham P.Wheeler 《Journal of Central South University》 SCIE EI CAS CSCD 2015年第9期3458-3470,共13页
The behavior of matrix converter(MC) drive systems under the condition of MC short-circuit faults is comprehensively investigated. Two isolation strategies using semiconductors and high speed fuses(HSFs) for MC short-... The behavior of matrix converter(MC) drive systems under the condition of MC short-circuit faults is comprehensively investigated. Two isolation strategies using semiconductors and high speed fuses(HSFs) for MC short-circuit faults are examined and their performances are compared. The behavior of MC drive systems during the fuse action time under different operating conditions is explored. The feasibility of fault-tolerant operation during the fuse action time is also studied. The basic selection laws for the HSFs and the requirements for the passive components of the MC drive system from the point view of short-circuit faults are also discussed. Simulation results are used to demonstrate the feasibility of the proposed isolation strategies. 展开更多
关键词 matrix converter short-circuit fault fault analysis fault behavior fault isolation
下载PDF
Sensor Fault Detection, Isolation and Reconstruction Using Nonlinear Principal Component Analysis 被引量:5
13
作者 Mohamed-Faouzi Harkat Salah Djelel +1 位作者 Noureddine Doghmane Mohamed Benouaret 《International Journal of Automation and computing》 EI 2007年第2期149-155,共7页
State reconstruction approach is very useful for sensor fault isolation, reconstruction of faulty measurement and the determination of the number of components retained in the principal components analysis (PCA) mod... State reconstruction approach is very useful for sensor fault isolation, reconstruction of faulty measurement and the determination of the number of components retained in the principal components analysis (PCA) model. An extension of this approach based on a Nonlinear PCA (NLPCA) model is described in this paper. The NLPCA model is obtained using five layer neural network. A simulation example is given to show the performances of the proposed approach. 展开更多
关键词 fault detection and isolation RECONSTRUCTION nonlinear PCA (NLPCA) neural networks.
下载PDF
Multiobjective fault detection and isolation for flexible air-breathing hypersonic vehicle 被引量:4
14
作者 Xuejing Cai Fen Wu 《Journal of Systems Engineering and Electronics》 SCIE EI CSCD 2011年第1期52-62,共11页
An application of the multiobjective fault detection and isolation(FDI) approach to an air-breathing hypersonic vehicle(HSV) longitudinal dynamics subject to disturbances is presented.Maintaining sustainable and s... An application of the multiobjective fault detection and isolation(FDI) approach to an air-breathing hypersonic vehicle(HSV) longitudinal dynamics subject to disturbances is presented.Maintaining sustainable and safe flight of HSV is a challenging task due to its strong coupling effects,variable operating conditions and possible failures of system components.A common type of system faults for aircraft including HSV is the loss of effectiveness of its actuators and sensors.To detect and isolate multiple actuator/sensor failures,a faulty linear parameter-varying(LPV) model of HSV is derived by converting actuator/system component faults into equivalent sensor faults.Then a bank of LPV FDI observers is designed to track individual fault with minimum error and suppress the effects of disturbances and other fault signals.The simulation results based on the nonlinear flexible HSV model and a nominal LPV controller demonstrate the effectiveness of the fault estimation technique for HSV. 展开更多
关键词 fault detection and isolation(FDI) hypersonic vehicle(HSV) actuator and sensor faults multiobjective optimization.
下载PDF
Performance of the geometric approach to fault detection and isolation in SISO,MISO,SIMO and MIMO systems 被引量:2
15
作者 RAHIMI N. SADEGHI M. H. MAHJOOB M. J. 《Journal of Zhejiang University-Science A(Applied Physics & Engineering)》 SCIE EI CAS CSCD 2007年第9期1443-1451,共9页
In this paper, a geometric approach to fault detection and isolation (FDI) is applied to a Multiple-Input Multipie-Output (MIMO) model of a frame and the FDI results are compared to the ones obtained in the Single... In this paper, a geometric approach to fault detection and isolation (FDI) is applied to a Multiple-Input Multipie-Output (MIMO) model of a frame and the FDI results are compared to the ones obtained in the Single-Input Single-Output (SISO), Multiple-Input Single-Output (MISO), and Single-Input Multiple-Output (SIMO) cases. A proper distance function based on parameters obtained from parametric system identification method is used in the geometric approach. ARX (Auto Regressive with exogenous input) and VARX (Vector ARX) models with 12 parameters are used in all of the above-mentioned models. The obtained results reveal that by increasing the number of inputs, the classification errors reduce, even in the case of applying only one of the inputs in the computations. Furthermore, increasing the number of measured outputs in the FDI scheme results in decreasing classification errors. Also, it is shown that by using probabilistic space in the distance function, fault diagnosis scheme has better performance in comparison with the deterministic one. 展开更多
关键词 fault detection and isolation (FDI) Multivariate systems Parametric system identification Linear regression Distance functions
下载PDF
A Fault Detection and Isolation Scheme Based on Parity Space Method for Discrete Time-delay System 被引量:1
16
作者 王红雨 田作华 +1 位作者 施颂椒 翁正新 《Journal of Donghua University(English Edition)》 EI CAS 2008年第3期304-307,共4页
A Fault detection and isolation(FDI)scheme for discrete time-delay system is proposed in this paper,which can not only detect but also isolate the faults.A time delay operator is introduced to resolve the problem bro... A Fault detection and isolation(FDI)scheme for discrete time-delay system is proposed in this paper,which can not only detect but also isolate the faults.A time delay operator is introduced to resolve the problem brought by the time-delay system.The design and computation for the FDI system is carried by computer math tool Maple,which can easily deal with the symbolic computation.Residuals in the form of parity space can be deduced from the recursion of the system equations.Further more,a generalized residual set is created using the freedom of the parity space redundancy.Thus,both fault detection and fault isolation have been accomplished.The proposed method has been verified by a numerical example. 展开更多
关键词 fault detection and isolation parity space time-delay system
下载PDF
Hybrid Fault Diagnosis and Isolation for Component and Sensor of APU in a Distributed Control System
17
作者 LU Feng YIN Zihan +3 位作者 ZHOU Xin ZHANG Yufei WANG Qin HUANG Jinquan 《Transactions of Nanjing University of Aeronautics and Astronautics》 EI CSCD 2022年第4期467-481,共15页
This paper addresses the gas path component and sensor fault diagnosis and isolation(FDI) for the auxiliary power unit(APU). A nonlinear dynamic model and a distributed state estimator are combined for the distributed... This paper addresses the gas path component and sensor fault diagnosis and isolation(FDI) for the auxiliary power unit(APU). A nonlinear dynamic model and a distributed state estimator are combined for the distributed control system. The distributed extended Kalman filter(DEKF)is served as a state estimator,which is utilized to estimate the gas path components’ flow capacity. The DEKF includes one main filter and five sub-filter groups related to five sensors of APU and each sub-filter yields local state flow capacity. The main filter collects and fuses the local state information,and then the state estimations are feedback to the sub-filters. The packet loss model is introduced in the DEKF algorithm in the APU distributed control architecture. FDI strategy with a performance index named weight sum of squared residuals(WSSR) is designed and used to identify the APU sensor fault by removing one sub-filter each time. The very sensor fault occurs as its performance index WSSR is different from the remaining sub-filter combinations. And the estimated value of the soft redundancy replaces the fault sensor measurement to isolate the fault measurement. It is worth noting that the proposed approach serves for not only the sensor failure but also the hybrid fault issue of APU gas path components and sensors. The simulation and comparison are systematically carried out by using the APU test data,and the superiority of the proposed methodology is verified. 展开更多
关键词 auxiliary power unit(APU) gas path fault sensor fault diagnosis and isolation packet loss model Kalman filter
下载PDF
Isolation of Whole-plant Multiple Oscillations via Non-negative Spectral Decompositio 被引量:2
18
作者 夏春明 郑建荣 John Howell 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2007年第3期353-360,共8页
Constrained spectral non-negative matrix factorization(NMF)analysis of perturbed oscillatory process control loop variable data is performed for the isolation of multiple plant-wide oscillatory sources.The technique i... Constrained spectral non-negative matrix factorization(NMF)analysis of perturbed oscillatory process control loop variable data is performed for the isolation of multiple plant-wide oscillatory sources.The technique is described and demonstrated by analyzing data from both simulated and real plant data of a chemical process plant. Results show that the proposed approach can map multiple oscillatory sources onto the most appropriate control loops,and has superior performance in terms of reconstruction accuracy and intuitive understanding compared with spectral independent component analysis(ICA). 展开更多
关键词 process monitoring multiple oscillations non-negative matrix factorization SPARSE spectral analysis fault isolation
下载PDF
Diagnosis of process faults and sensor faults in a class of nonlinear uncertain systems 被引量:2
19
作者 Niharika Sonti 《Journal of Systems Engineering and Electronics》 SCIE EI CSCD 2011年第1期22-32,共11页
This paper presents a fault diagnosis method for process faults and sensor faults in a class of nonlinear uncertain systems.The fault detection and isolation architecture consists of a fault detection estimator and a ... This paper presents a fault diagnosis method for process faults and sensor faults in a class of nonlinear uncertain systems.The fault detection and isolation architecture consists of a fault detection estimator and a bank of adaptive isolation estimators,each corresponding to a particular fault type.Adaptive thresholds for fault detection and isolation are presented.Fault detectability conditions characterizing the class of process faults and sensor faults that are detectable by the presented method are derived.A simulation example of robotic arm is used to illustrate the effectiveness of the fault diagnosis method. 展开更多
关键词 fault detection fault isolation fault detectability ROBUSTNESS sensor bias process faults.
下载PDF
Hybrid robust fault detection and isolation of satellite reaction wheel actuators
20
作者 H.Abbasi Nozari S.J.Sadati Rostami +1 位作者 Paolo Castaldi Silvio Simani 《Journal of Control and Decision》 EI 2024年第1期117-131,共15页
In this paper,a combined robust fault detection and isolation scheme is studied for satellite system subject to actuator faults,external disturbances,and parametric uncertainties.The proposed methodology incorporates ... In this paper,a combined robust fault detection and isolation scheme is studied for satellite system subject to actuator faults,external disturbances,and parametric uncertainties.The proposed methodology incorporates a residual generation module,including a bank of filters,into an intelligent residual evaluation module.First,residual filters are designed based on an improved nonlinear differential algebraic approach so that they are not affected by external disturbances.The residual evaluation module is developed based on the suggested series and parallel forms.Further,a new ensemble classification scheme defined as blended learning integrates heterogeneous classifiers to enhance the performance.A wide range of simulations is carried out in a high-fidelity satellite simulator subject to the constant and time-varying actuator faults in the presence of disturbances,manoeuvres,uncertainties,and noises.The obtained results demonstrate the effectiveness of the proposed robust fault detection and isolation method compared to the traditional nonlinear differential algebraic approach. 展开更多
关键词 Robust fault detection and isolation reaction wheels blended learning series and parallel fault detection and isolation forms satellite attitude control system
原文传递
上一页 1 2 下一页 到第
使用帮助 返回顶部