期刊文献+
共找到129,685篇文章
< 1 2 250 >
每页显示 20 50 100
Fault Ride-Through Capability Enhancement of PV System with Voltage Support Control Strategy 被引量:1
1
作者 Dehui Zeng Gang Wang +1 位作者 Guoqing Pan Haifeng Li 《Open Journal of Applied Sciences》 2013年第2期30-34,共5页
With continuously increasing of photovoltaic (PV) plant’s penetration, it has become a critical issue to improve the fault ride-through capability of PV plant. This paper refers to the German grid code, and the PV sy... With continuously increasing of photovoltaic (PV) plant’s penetration, it has become a critical issue to improve the fault ride-through capability of PV plant. This paper refers to the German grid code, and the PV system is controlled to keep grid connected, as well as inject reactive current to grid when fault occurs. The mathematical model of PV system is established and the fault characteristic is studied with respect to the control strategy. By analyzing the effect of reactive power supplied by the PV system to the point of common coupling (PCC) voltage, this paper proposes an adaptive voltage support control strategy to enhance the fault ride-through capability of PV system. The control strategy fully utilizes the PV system’s capability of voltage support and takes the safety of equipment into account as well. At last, the proposed control strategy is verified by simulation. 展开更多
关键词 PV System fault ride-through VOLTAGE Support Control Strategy
下载PDF
Fault Ride-Through Capability of Full-Power Converter Wind Turbine 被引量:1
2
作者 A.S. Makinen O. Raipala K. Maki S. Repo H. Tuusa 《Journal of Energy and Power Engineering》 2010年第10期29-45,共17页
关键词 电力系统故障 风力发电机组 全功率变换器 能力 风力涡轮机 电源转换器 汽轮机保护 断电
下载PDF
Fault Ride-Through Study of Wind Turbines
3
作者 Xinyan Zhang Xuan Cao +1 位作者 Weiqing Wang Chao Yun 《Journal of Power and Energy Engineering》 2013年第5期25-29,共5页
The installation of wind energy has increased rapidly around the world. The grid codes about the wind energy require wind turbine (WT) has the ability of fault (or low voltage) ride-through (FRT). To study the FRT ope... The installation of wind energy has increased rapidly around the world. The grid codes about the wind energy require wind turbine (WT) has the ability of fault (or low voltage) ride-through (FRT). To study the FRT operation of the wind farms, three methods were discussed. First, the rotor short current of doubly-fed induction generator (DFIG) was limited by introducing a rotor side protection circuit. Second, the voltage of DC bus was limited by a DC energy absorb circuit. Third, STATCOM was used to increase the low level voltages of the wind farm. Simulation under MATLAB was studied and the corresponding results were given and discussed. The methods proposed in this paper can limit the rotor short current and the DC voltage of the DFIG WT to some degree, but the voltage support to the power system during the fault largely depend on the installation place of STATCOM. 展开更多
关键词 WIND Energy fault ride-through DOUBLY-FED INDUCTION GENERATOR WIND FARM
下载PDF
Validation of Full-Converter Wind Power Plant Generic Model Based on Actual Fault Ride-Through Measurements
4
作者 O. Tsernobrovkin A. Perdana +1 位作者 I. Palu J. Kilter 《Journal of Energy and Power Engineering》 2010年第4期54-62,共9页
关键词 功率转换器 模型验证 测量数据 电厂 动力学模型 风力涡轮机 实地测量 实践能力
下载PDF
Fault Ride-Through(FRT)Behavior in VSC-HVDC as Key Enabler of Transmission Systems Using SCADA Viewer Software
5
作者 Samuel Bimenyimana Chen Wang +9 位作者 Godwin Norense Osarumwense Asemota Aphrodis Nduwamungu Francis Mulolani Jean De Dieu Niyonteze Shilpi Bora Chun-Ling Ho Noel Hagumimana Theobald Habineza Waqar Bashir Yiyi Mo 《Energy Engineering》 EI 2022年第6期2369-2406,共38页
The world’s energy consumption and power generation demand will continue to rise.Furthermore,the bulk of the energy resources needed to satisfy the rising demand is far from the load centers.The aforementioned requir... The world’s energy consumption and power generation demand will continue to rise.Furthermore,the bulk of the energy resources needed to satisfy the rising demand is far from the load centers.The aforementioned requires long-distance transmission systems and one way to accomplish this is to use high voltage direct current(HVDC)transmission systems.The main technical issues for HVDC transmission systems are loss of synchronism,variation of quadrature currents,amplitude,the inability of station 1(rectifier),and station 2(inverter)to either inject,or absorb active,or reactive power in the network in any circumstances(before a fault occurs,during having a fault in network and after a fault cleared),and the variations of power transfer capabilities.Additionally,faults impact power quality such as voltage dips and power line outage time.This paper presents a method of overcoming the aforementioned technical issues using voltage-source converter(VSC)based HVDC transmission systems with SCADA VIEWER software and dynamic grid simulator.The benefits include having a higher capacity transmission system and proposed best method for control of active and reactive power transfer capabilities.Simulation results obtained using MATLAB validated the experimental results from SCADA Viewer software.The results indicate that the station’s rectifier or inverter can either inject or absorb either active power or reactive power in any circumstance.Also,the reverse power flow under different modes of operation can ride through faults.At a 100.0%power transfer rate,the rectifier injected 775.0 W into the network.At a 0.0%power transfer rate,the rectifier injected 164.0 W into the network.At a-100.0%rated power,the rectifier injected 1264.0 W into the network and direction was also changed. 展开更多
关键词 fault ride through capability dynamic grid fault simulator asymmetric components negative sequence control
下载PDF
Fault Ride-through Hybrid Controller for MMC-HVDC Transmission System via Switching Control Units Based on Bang-bang Funnel Controller 被引量:1
6
作者 Yang Liu Zehui Lin +1 位作者 Chenying Xu Lei Wang 《Journal of Modern Power Systems and Clean Energy》 SCIE EI CSCD 2023年第2期599-610,共12页
This paper proposes a fault ride-through hybrid controller(FRTHC)for modular multi-level converter based high-voltage direct current(MMC-HVDC)transmission systems.The FRTHC comprises four loops of cascading switching ... This paper proposes a fault ride-through hybrid controller(FRTHC)for modular multi-level converter based high-voltage direct current(MMC-HVDC)transmission systems.The FRTHC comprises four loops of cascading switching control units(SCUs).Each SCU switches between a bang-bang funnel controller(BBFC)and proportional-integral(PI)control loop according to a state-dependent switching law.The BBFC can utilize the full control capability of each control loop using three-value control signals with the maximum available magnitude.A state-dependent switching law is designed for each SCU to guarantee its structural stability.Simulation studies are conducted to verify the superior fault ride-through capability of the MMC-HVDC transmission system controlled by FRTHC,in comparison to that controlled by a vector controller(VC)and a VC with DC voltage droop control(VDRC). 展开更多
关键词 Bang-bang funnel controller(BBFC) fault ride-through hybrid controller modular multi-level converter based high-voltage direct-current(MMC-HVDC) switching control unit
原文传递
Dual-mode Switching Fault Ride-through Control Strategy for Self-synchronous Wind Turbines
7
作者 Xinshou Tian Yongning Chi +3 位作者 Peng Cheng Wei He Yunpeng Zhou Jianzhu Hu 《Journal of Modern Power Systems and Clean Energy》 SCIE EI CSCD 2023年第2期579-588,共10页
The installed capacity of renewable energy generation has continued to grow rapidly in recent years along with the global energy transition towards a 100%renewable-based power system.At the same time,the grid-connecte... The installed capacity of renewable energy generation has continued to grow rapidly in recent years along with the global energy transition towards a 100%renewable-based power system.At the same time,the grid-connected large-scale renewable energy brings significant challenges to the safe and stable operation of the power system due to the loss of synchronous machines.Therefore,self-synchronous wind turbines have attracted wide attention from both academia and industry.However,the understanding of the physical operation mechanisms of self-synchronous wind turbines is not clear.In particular,the transient characteristics and dynamic processes of wind turbines are fuzzy in the presence of grid disturbances.Furthermore,it is difficult to design an adaptive fault ride-through(FRT)control strategy.Thus,a dual-mode switching FRT control strategy for self-synchronous wind turbines is developed.Two FRT control strategies are used.In one strategy,the amplitude and phase of the internal potential are directly calculated according to the voltage drop when a minor grid fault occurs.The other dual-mode switching control strategy in the presence of a deep grid fault includes three parts:vector control during the grid fault,fault recovery vector control,and self-synchronous control.The proposed control strategy can significantly mitigate transient overvoltage,overcurrent,and multifrequency oscillation,thereby resulting in enhanced transient stability.Finally,simulation results are provided to validate the proposed control strategy. 展开更多
关键词 Dual-mode switching self-synchronous wind turbine transient stability fault ride-through(FRT)control
原文传递
A Continuous Fault Ride-through Scheme for DFIGs Under Commutation Failures in LCC-HVDC Transmission Systems
8
作者 Zixuan Zheng Donghui Song +3 位作者 Kaijian Du Xianyong Xiao Jie Ren Qi Xie 《Journal of Modern Power Systems and Clean Energy》 SCIE EI CSCD 2023年第4期1126-1135,共10页
Experimental and theoretical studies have confirmed that,relative to a one-shot voltage fault,a doubly-fed induction generator(DFIG)will suffer a greater transient impact during continuous voltage faults.This paper pr... Experimental and theoretical studies have confirmed that,relative to a one-shot voltage fault,a doubly-fed induction generator(DFIG)will suffer a greater transient impact during continuous voltage faults.This paper presents the design and application of an effective scheme for DFIGs when a commutation failure(CF)occurs in a line-commutated converter based high-voltage direct current(LCC-HVDC)transmission system.First,transient demagnetization control without filters is proposed to offset the electromotive force(EMF)induced by the natural flux and other low-frequency flux components.Then,a rotor-side integrated impedance circuit is designed to limit the rotor overcurrent to ensure that the rotor-side converter(RSC)is controllable.Furthermore,coordinated control of the demagnetization and segmented reactive currents is implemented in the RSC.Comparative studies have shown that the proposed scheme can limit rotor fault currents and effectively improve the continuous fault ride-through capability of DFIGs. 展开更多
关键词 Continuous fault commutation failure(CF) doubly-fed induction generator(DFIG) fault ride-through(FRT)capability high-voltage direct current(HVDC)
原文传递
Enhanced AC Fault Ride-through Control for MMC-integrated System Based on Active PCC Voltage Drop
9
作者 Haihan Ye Wu Chen +3 位作者 Heng Wu Wu Cao Guoqing He Guanghui Li 《Journal of Modern Power Systems and Clean Energy》 SCIE EI CSCD 2023年第4期1316-1330,共15页
When a renewable energy station(RES)connects to the rectifier station(RS)of a modular multilevel converterbased high-voltage direct current(MMC-HVDC)system,the voltage at the point of common coupling(PCC)is determined... When a renewable energy station(RES)connects to the rectifier station(RS)of a modular multilevel converterbased high-voltage direct current(MMC-HVDC)system,the voltage at the point of common coupling(PCC)is determined by RS control methods.For example,RS control may become saturated under fault,and causes the RS to change from an equivalent voltage source to an equivalent current source,making fault analysis more complicated.In addition,the grid code of the fault ride-through(FRT)requires the RES to output current according to its terminal voltage.This changes the fault point voltage and leads to RES voltage regulation and current redistribution,resulting in fault response interactions.To address these issues,this study describes how an MMC-integrated system has five operation modes and three common characteristics under the duration of the fault.The study also reveals several instances of RS performance degradation such as AC voltage loop saturation,and shows that RS power reversal can be significantly improved.An enhanced AC FRT control method is proposed to achieve controllable PCC voltage and continuous power transmission by actively reducing the PCC voltage amplitude.The robustness of the method is theoretically proven under parameter variation and operation mode switching.Finally,the feasibility of the proposed method is verified through MATLAB/Simulink results. 展开更多
关键词 Modular multilevel converter-based high-voltage direct current(MMC-HVDC)system fault ride-through(FRT) voltage loop saturation continuous power transmission point of common coupling(PCC) active voltage drop control
原文传递
Application of MMC with Embedded Energy Storage for Overvoltage Suppression and Fault Ride-through Improvement in Series LCCMMC Hybrid HVDC System
10
作者 Xiaodong Li Zheng Xu Zheren Zhang 《Journal of Modern Power Systems and Clean Energy》 SCIE EI CSCD 2023年第3期1001-1013,共13页
The series line-commutated converter(LCC)and modular multilevel converter(MMC)hybrid high-voltage direct current(HVDC)system provides a more economical and flexible alternative for ultra-HVDC(UHVDC)transmission,which ... The series line-commutated converter(LCC)and modular multilevel converter(MMC)hybrid high-voltage direct current(HVDC)system provides a more economical and flexible alternative for ultra-HVDC(UHVDC)transmission,which is the so-called Baihetan-Jiangsu HVDC(BJ-HVDC)project of China.In one LCC and two MMCs(1+2)operation mode,the sub-module(SM)capacitors suffer the most rigorous overvoltage induced by three-phase-to-ground fault at grid-side MMC and valve-side single-phase-to-ground fault in internal MMC.In order to suppress such huge overvoltage,this paper demonstrates a novel alternative by employing the MMC-based embedded battery energy storage system(MMC-BESS).Firstly,the inducements of SM overvoltage are analyzed.Then,coordinated with MMC-BESS,new fault ride-through(FRT)strategies are proposed to suppress the overvoltage and improve the FRT capability.Finally,several simulation scenarios are carried out on PSCAD/EMTDC.The overvoltage suppression is verified against auxiliary device used in the BJ-HVDC project in a monopolar BJ-HVDC system.Further,the proposed FRT strategies are validated in the southern Jiangsu power grid of China based on the planning data in the summer of 2025.Simulation results show that the MMC-BESS and proposed FRT strategies could effectively suppress the overvoltage and improve the FRT capability. 展开更多
关键词 Line-commutated converter(LCC) modular multilevel converter(MMC) MMC-based embedded battery energy storage system(MMC-BESS) fault ride-through(FRT)capability overvoltage suppression
原文传递
Expert Experience and Data-Driven Based Hybrid Fault Diagnosis for High-SpeedWire Rod Finishing Mills 被引量:1
11
作者 Cunsong Wang Ningze Tang +3 位作者 Quanling Zhang Lixin Gao Haichen Yin Hao Peng 《Computer Modeling in Engineering & Sciences》 SCIE EI 2024年第2期1827-1847,共21页
The reliable operation of high-speed wire rod finishing mills is crucial in the steel production enterprise.As complex system-level equipment,it is difficult for high-speed wire rod finishing mills to realize fault lo... The reliable operation of high-speed wire rod finishing mills is crucial in the steel production enterprise.As complex system-level equipment,it is difficult for high-speed wire rod finishing mills to realize fault location and real-time monitoring.To solve the above problems,an expert experience and data-driven-based hybrid fault diagnosis method for high-speed wire rod finishing mills is proposed in this paper.First,based on its mechanical structure,time and frequency domain analysis are improved in fault feature extraction.The approach of combining virtual value,peak value with kurtosis value index,is adopted in time domain analysis.Speed adjustment and side frequency analysis are proposed in frequency domain analysis to obtain accurate component characteristic frequency and its corresponding sideband.Then,according to time and frequency domain characteristics,fault location based on expert experience is proposed to get an accurate fault result.Finally,the proposed method is implemented in the equipment intelligent diagnosis system.By taking an equipment fault on site,for example,the effectiveness of the proposed method is illustrated in the system. 展开更多
关键词 High-speed wire rod finishing mills expert experience DATA-DRIVEN fault diagnosis
下载PDF
The MW5.5 earthquake on August 6,2023,in Pingyuan,Shandong,China:A rupture on a buried fault 被引量:2
12
作者 Zhe Zhang Lisheng Xu Lihua Fang 《Earthquake Science》 2024年第1期1-12,共12页
On August 6,2023,a magnitude MW5.5 earthquake struck Pingyuan County,Dezhou City,Shandong Province,China.This event was significant as no large earthquakes had been recorded in the region for over a century,and no act... On August 6,2023,a magnitude MW5.5 earthquake struck Pingyuan County,Dezhou City,Shandong Province,China.This event was significant as no large earthquakes had been recorded in the region for over a century,and no active fault had been previously identified.This study collects 1309 P-wave arrival times and 866 S-wave arrival times from 74 seismic stations less than 200 km to the epicenter to constrain the spatial distribution of the mainshock and its 125 early aftershocks by the double difference earthquake relocation method,and selects 864 P-waveforms from 288 stations located within 800 km of the epicenter to constrain the focal mechanism solution of the mainshock through centroid moment tensor inversion.The relocation and the inversion indicate,the Pingyuan MW5.5 earthquake was caused by a rupture on a buried fault,likely an extensive segment of the Gaotang fault.This buried fault exhibited a dip of approximately 75°to the northwest,with a strike of 222°,similar to the Gaotang fault.The rupture initiated at the depth of 18.6 km and propagated upward and northeastward.However,the ground surface was not broken.The total duration of the rupture was~6.0 s,releasing the scalar moment of 2.5895×1017 N·m,equivalent to MW5.54.The moment rate reached the maximum only 1.4 seconds after the rupture initiation,and the 90%scalar moment was released in the first 4.6 s.In the first 1.4 seconds of the rupture process,the rupture velocity was estimated to be 2.6 km/s,slower than the local S-wave velocity.As the rupture neared its end,the rupture velocity decreased significantly.This study provides valuable insights into the seismic characteristics of the Pingyuan MW5.5 earthquake,shedding light on the previously unidentified buried fault responsible for the seismic activity in the region.Understanding the behavior of such faults is crucial for assessing seismic hazards and enhancing earthquake preparedness in the future. 展开更多
关键词 Shandong Pingyuan MW5.5 earthquake double-difference earthquake location centroid moment tensor inversion buried fault
下载PDF
Formation mechanism of fault accommodation zones under combined stress in graben basin:Implications from geomechanical modeling
13
作者 Qi-Qiang Ren Jin-Liang Gao +3 位作者 Rong-Tao Jiang Jin Wang Meng-Ping Li Jian-Wei Feng 《Petroleum Science》 SCIE EI CAS CSCD 2024年第1期54-76,共23页
A fault accommodation zone is a type of structure that is defined as regulating displacement and strain between faults structure.Increasing numbers of fault accommodation zones are being identified in graben basins,in... A fault accommodation zone is a type of structure that is defined as regulating displacement and strain between faults structure.Increasing numbers of fault accommodation zones are being identified in graben basins,indicating the potential exploration target and petroleum accumulation areas.This study aims to analyze the formation mechanism and development of fault accommodation zones under combined stress by a numerical simulation method considering geomechanical modeling.Using three-dimensional(3-D)seismic interpretation and fractal dimension method,exampled with the Dongxin fault zone,the fault activity and fault combination pattern were conducted to quantitatively characterize the activity difference in fault accommodation zones.Combined with mechanical experiment test,a geomehcanical model was established for fault accommodation zones in a graben basin.Integrating the paleostress numerical simulations and structural physical simulation experiment,the developmental characteristics and genetic mechanism of fault accommodation zones were summarized.Influenced by multi movements and combined stresses,three significant tectonic evolution stages of the Dongxing Fault Zone(DXFZ)were distinguished:During the E_(s)^(3)sedimentary period,the large difference in the stress,strain,and rupture distribution in various faults were significant,and this stage was the key generation period for the prototype of the DXFZ,including the FAZ between large-scale faults.During the E_(s)^(2)sedimentary period,the EW-trending symmetric with opposite dipping normal faults and the NE-SW trending faults with large scale were furtherly developed.The junction area of two secondary normal faults were prone to be ruptured,performing significant period for inheriting and developing characteristics of fault accommodation zones.During the Es1 sedimentary period,the high-order faults in the DXFZ exhibited the obvious fault depressions and strike-slip activity,and the fault accommodation zones were furtherly inherited and developed.This stage was the molded and formative period of the FAZ,the low-order faults,and the depression in the DXFZ. 展开更多
关键词 fault accommodation zone Graben basin fault activity Tectonic physical simulation experiment Finite element numerical simulation Dongxin fault zone
下载PDF
Advances in seismological methods for characterizing fault zone structure
14
作者 Yan Cai Jianping Wu +1 位作者 Yaning Liu Shijie Gao 《Earthquake Science》 2024年第2期122-138,共17页
Large earthquakes frequently occur along complex fault systems.Understanding seismic rupture and long-term fault evolution requires constraining the geometric and material properties of fault zone structures.We provid... Large earthquakes frequently occur along complex fault systems.Understanding seismic rupture and long-term fault evolution requires constraining the geometric and material properties of fault zone structures.We provide a comprehensive overview of recent advancements in seismological methods used to study fault zone structures,including seismic tomography,fault zone seismic wave analysis,and seismicity analysis.Observational conditions limit our current ability to fully characterize fault zones,for example,insufficient imaging resolution to discern small-scale anomalies,incomplete capture of crucial fault zone seismic waves,and limited precision in event location accuracy.Dense seismic arrays can overcome these limitations and enable more detailed investigations of fault zone structures.Moreover,we present new insights into the structure of the Anninghe-Xiaojiang fault zone in the southeastern margin of the Qinghai-Xizang Plateau based on data collected from a dense seismic array.We found that utilizing a dense seismic array can identify small-scale features within fault zones,aiding in the interpretation of fault zone geometry and material properties. 展开更多
关键词 fault zone structure TOMOGRAPHY fault zone wave seismic activity Anninghe-Xiaojiang fault zone
下载PDF
Characterization and spatial analysis of coseismic landslides triggered by the Luding Ms 6.8 earthquake in the Xianshuihe fault zone, Southwest China
15
作者 GUO Changbao LI Caihong +10 位作者 YANG Zhihua NI Jiawei ZHONG Ning WANG Meng YAN Yiqiu SONG Deguang ZHANG Yanan ZHANG Xianbing WU Ruian CAO Shichao SHAO Weiwei 《Journal of Mountain Science》 SCIE CSCD 2024年第1期160-181,共22页
On September 5, 2022, a magnitude Ms 6.8 earthquake occurred along the Moxi fault in the southern part of the Xianshuihe fault zone located in the southeastern margin of the Tibetan Plateau,resulting in severe damage ... On September 5, 2022, a magnitude Ms 6.8 earthquake occurred along the Moxi fault in the southern part of the Xianshuihe fault zone located in the southeastern margin of the Tibetan Plateau,resulting in severe damage and substantial economic loss. In this study, we established a coseismic landslide database triggered by Luding Ms 6.8 earthquake, which includes 4794 landslides with a total area of 46.79 km^(2). The coseismic landslides primarily consisted of medium and small-sized landslides, characterized by shallow surface sliding. Some exhibited characteristics of high-position initiation resulted in the obstruction or partial obstruction of rivers, leading to the formation of dammed lakes. Our research found that the coseismic landslides were predominantly observed on slopes ranging from 30° to 50°, occurring at between 1000 m and 2500 m, with slope aspects varying from 90° to 180°. Landslides were also highly developed in granitic bodies that had experienced structural fracturing and strong-tomoderate weathering. Coseismic landslides concentrated within a 6 km range on both sides of the Xianshuihe and Daduhe fault zones. The area and number of coseismic landslides exhibited a negative correlation with the distance to fault lines, road networks, and river systems, as they were influenced by fault activity, road excavation, and river erosion. The coseismic landslides were mainly distributed in the southeastern region of the epicenter, exhibiting relatively concentrated patterns within the IX-degree zones such as Moxi Town, Wandong River basin, Detuo Town to Wanggangping Township. Our research findings provide important data on the coseismic landslides triggered by the Luding Ms 6.8 earthquake and reveal the spatial distribution patterns of these landslides. These findings can serve as important references for risk mitigation, reconstruction planning, and regional earthquake disaster research in the earthquake-affected area. 展开更多
关键词 Luding earthquake Coseismic landslides Remote sensing interpretation Spatial distribution Xianshuihe fault Earthquake fault
下载PDF
An Insight Survey on Sensor Errors and Fault Detection Techniques in Smart Spaces
16
作者 Sheetal Sharma Kamali Gupta +2 位作者 DeepaliGupta Shalli Rani Gaurav Dhiman 《Computer Modeling in Engineering & Sciences》 SCIE EI 2024年第3期2029-2059,共31页
The widespread adoption of the Internet of Things (IoT) has transformed various sectors globally, making themmore intelligent and connected. However, this advancement comes with challenges related to the effectiveness... The widespread adoption of the Internet of Things (IoT) has transformed various sectors globally, making themmore intelligent and connected. However, this advancement comes with challenges related to the effectiveness ofIoT devices. These devices, present in offices, homes, industries, and more, need constant monitoring to ensuretheir proper functionality. The success of smart systems relies on their seamless operation and ability to handlefaults. Sensors, crucial components of these systems, gather data and contribute to their functionality. Therefore,sensor faults can compromise the system’s reliability and undermine the trustworthiness of smart environments.To address these concerns, various techniques and algorithms can be employed to enhance the performance ofIoT devices through effective fault detection. This paper conducted a thorough review of the existing literature andconducted a detailed analysis.This analysis effectively links sensor errors with a prominent fault detection techniquecapable of addressing them. This study is innovative because it paves theway for future researchers to explore errorsthat have not yet been tackled by existing fault detection methods. Significant, the paper, also highlights essentialfactors for selecting and adopting fault detection techniques, as well as the characteristics of datasets and theircorresponding recommended techniques. Additionally, the paper presents amethodical overview of fault detectiontechniques employed in smart devices, including themetrics used for evaluation. Furthermore, the paper examinesthe body of academic work related to sensor faults and fault detection techniques within the domain. This reflectsthe growing inclination and scholarly attention of researchers and academicians toward strategies for fault detectionwithin the realm of the Internet of Things. 展开更多
关键词 ERROR fault detection techniques sensor faults OUTLIERS Internet of Things
下载PDF
Dynamic Vision Enabled Contactless Cross-Domain Machine Fault Diagnosis With Neuromorphic Computing
17
作者 Xinrui Chen Xiang Li +3 位作者 Shupeng Yu Yaguo Lei Naipeng Li Bin Yang 《IEEE/CAA Journal of Automatica Sinica》 SCIE EI CSCD 2024年第3期788-790,共3页
Dear Editor,This letter presents a novel dynamic vision enabled contactless cross-domain fault diagnosis method with neuromorphic computing.The event-based camera is adopted to capture the machine vibration states in ... Dear Editor,This letter presents a novel dynamic vision enabled contactless cross-domain fault diagnosis method with neuromorphic computing.The event-based camera is adopted to capture the machine vibration states in the perspective of vision. 展开更多
关键词 fault LESS DIAGNOSIS
下载PDF
Estimation of Displacement and Extension due to Reverse Drag of Normal Faults: Forward Method
18
作者 Shunshan Xu Angel Francisco Nieto-Samaniego +1 位作者 Huilong Xu Susana Alicia Alaniz-Álvarez 《International Journal of Geosciences》 CAS 2024年第1期25-39,共15页
In the case of reverse drag of normal faulting, the displacement and horizontal extension are determined based on the established equations for the three mechanisms: rigid body, vertical shear and inclined shear. Ther... In the case of reverse drag of normal faulting, the displacement and horizontal extension are determined based on the established equations for the three mechanisms: rigid body, vertical shear and inclined shear. There are three sub-cases of basal detachment for the rigid body model: horizontal detachment, antithetic detachment and synthetic detachment. For the rigid body model, the established equations indicate that the total displacement on the synthetic base (D<sub>t2</sub>) is the largest, that on the horizontal base (D<sub>t1</sub>) is moderate, and that on the antithetic base (D<sub>t3</sub>) is the smallest. On the other hand, the value of (D<sub>t1</sub>) is larger than the displacement for the vertical shear (D<sub>t4</sub>). The value of (D<sub>t1</sub>) is larger than or less than the displacement for the inclined shear (D<sub>t5</sub>) depending on the original fault dip δ<sub>0</sub>, bedding angle θ, and the angle of shear direction β. For all original parameters, the value of D<sub>t5</sub> is less than the value of D<sub>t4</sub>. Also, by comparing three rotation mechanisms, we find that the inclined shear produces largest extension, the rigid body model with horizontal detachment produces the smallest extension, and the vertical shear model produces moderate extension. 展开更多
关键词 fault Rotation fault Drag fault Displacement EXTENSION Forward Model
下载PDF
Experimental investigation on the origin of carbonaceous materials in the fault zone of the Wenchuan earthquake
19
作者 Deyang Shi Yaowei Liu Jin Shi 《Earthquake Science》 2024年第3期189-199,共11页
Carbonaceous materials in seismic fault zones may considerably influence seismic fault slip;however,the formation mechanism of carbonaceous materials remains unclear.In this study,we proposed a novel hypothesis for th... Carbonaceous materials in seismic fault zones may considerably influence seismic fault slip;however,the formation mechanism of carbonaceous materials remains unclear.In this study,we proposed a novel hypothesis for the formation of carbonaceous materials in fault gouge.Thus,we conducted a CO2 hydrogenation experiment in a high-temperature reactor at a co-seismic temperature,with fault gouge formed during the Wenchuan earthquake as the catalyst.Our experimental results demonstrate that carbonaceous materials in fault zones are formed on the fault gouge during the chemical reaction process,suggesting that the carbonaceous materials are possibly generated from the catalytic hydrogenation of CO2,followed by thermal cracking of its products.The results of this study provide a theoretical basis for understanding fault behavior and earthquake physics. 展开更多
关键词 carbon dioxide hydrogenation carbonaceous mineral formation co-seismic temperature fault weakening fault gouge
下载PDF
Autonomous Recommendation of Fault Detection Algorithms for Spacecraft
20
作者 Wenbo Li Baoling Ning 《IEEE/CAA Journal of Automatica Sinica》 SCIE EI CSCD 2024年第1期273-275,共3页
Dear Editor, This letter deals with the problem of algorithm recommendation for online fault detection of spacecraft. By transforming the time series data into distributions and introducing a distribution-aware measur... Dear Editor, This letter deals with the problem of algorithm recommendation for online fault detection of spacecraft. By transforming the time series data into distributions and introducing a distribution-aware measure, a principal method is designed for quantifying the detectabilities of fault detection algorithms over special datasets. 展开更多
关键词 fault introducing LETTER
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部