Introduction:Parallel stent-stent grafting is a major endovascular technique used to preserve the supra-aortic branches during thoracic endovascular aortic repair(TEVAR)of aortic pathologies involving the aortic arch....Introduction:Parallel stent-stent grafting is a major endovascular technique used to preserve the supra-aortic branches during thoracic endovascular aortic repair(TEVAR)of aortic pathologies involving the aortic arch.The short-and mid-term results of this technique are satisfactory;however,endoleak remains a major concern.Thus,here we designed a new chimney stent-graft to decrease the endoleak rate.Aim:To testify the feasibility and safety of the new chimney stent-graft system in a canine model.Material and methods:Six Labrador retrievers were used.Pre-operative data were collected and all operations were performed under general anesthesia.The main and chimney stent-grafts were implanted through the abdominal aorta and left subclavian artery approaches,respectively.Completion digital subtraction angiography(DSA)was performed to confirm the immediate outcomes.All dogs were fed separately for 6 months and sacrificed after aortic angiography.The thoracic aorta and the main and chimney stent-grafts were harvested for histopathologic examination.Results:No complications were found in follow-up DSA.All branch arteries were patent.In?ammatory responses were observed around the stent-grafts in 3 experimental animals,and slight hyperplasia was observed in the surrounding tissues compared with the normal vessels.There was no mural thrombus in the stent,endothelial cells were noted on the inner surface of the stent,and thrombus was formed in the outer skirt and gutter area.The histopathologic examinations revealed similar results to those of gross necropsy observations.Conclusions:This study demonstrated the feasibility and safety of the Longuette stent-graft and the first to report a revised stent-graft specific for chimney technique.展开更多
Superior long-term anchorage of the bridging stent-grafts from the fenestrated main body endograft could be achieved with the addition of a flared cuff,capable of preventing the previously observed fabric fraying arou...Superior long-term anchorage of the bridging stent-grafts from the fenestrated main body endograft could be achieved with the addition of a flared cuff,capable of preventing the previously observed fabric fraying around the fenestration as a result of the balloon angioplasty of the seal zone.This novel stent cuff design will also facilitate more complete biointegration of the devices,eliminate the hemodynamic variation as well as significantly reduce the possibility of a Type III endoleak.The feasibility of this concept is demonstrated by observations made from in-situ tests performed in a Beta endograft design.Flared cuffs made of poly(ε-caprolactone)supported with a weft-knitted polyester structure can be manufactured with various configurations to optimize the transition from the main body of the endograft,thus preventing the currently marketed designs’hemodynamic perturbation while also promoting endograft biointegration.This concept represents an evolution in branch graft design,which may enhance the long-term durability of customized fenestrations and open new applications for in-vivo graft fenestration in the near future.Further ongoing investigation to optimize its structure,X-ray opacity,fixation to the flared stent,and material biocompatibility are still required to build upon this concept’s proof.展开更多
文摘Introduction:Parallel stent-stent grafting is a major endovascular technique used to preserve the supra-aortic branches during thoracic endovascular aortic repair(TEVAR)of aortic pathologies involving the aortic arch.The short-and mid-term results of this technique are satisfactory;however,endoleak remains a major concern.Thus,here we designed a new chimney stent-graft to decrease the endoleak rate.Aim:To testify the feasibility and safety of the new chimney stent-graft system in a canine model.Material and methods:Six Labrador retrievers were used.Pre-operative data were collected and all operations were performed under general anesthesia.The main and chimney stent-grafts were implanted through the abdominal aorta and left subclavian artery approaches,respectively.Completion digital subtraction angiography(DSA)was performed to confirm the immediate outcomes.All dogs were fed separately for 6 months and sacrificed after aortic angiography.The thoracic aorta and the main and chimney stent-grafts were harvested for histopathologic examination.Results:No complications were found in follow-up DSA.All branch arteries were patent.In?ammatory responses were observed around the stent-grafts in 3 experimental animals,and slight hyperplasia was observed in the surrounding tissues compared with the normal vessels.There was no mural thrombus in the stent,endothelial cells were noted on the inner surface of the stent,and thrombus was formed in the outer skirt and gutter area.The histopathologic examinations revealed similar results to those of gross necropsy observations.Conclusions:This study demonstrated the feasibility and safety of the Longuette stent-graft and the first to report a revised stent-graft specific for chimney technique.
基金This work was supported by“the Fundamental Research Funds for the Central Universities”(2232019D3-16)(China)the 111 Project 2.0“Biomedical Textile Materials Science and Technology”(B07024)(China)+3 种基金the Shanghai Science and Technology Support Project(18441902600)(China)the Engineering Research Center of Technical Textiles Ministry of Education(China)the Department of Surgery at Laval University(Quebec,Canada)the Fonds de Recherche de chirurgie vasculaire of the CHU(Quebec,Canada).The generous gift of device,by Medtronic and Vascutek is greatly acknowledged.The authors extend their appreciation to Boyin Qin,Yvan Douville,Pascal Rheaume,and Raymond Labbe.
文摘Superior long-term anchorage of the bridging stent-grafts from the fenestrated main body endograft could be achieved with the addition of a flared cuff,capable of preventing the previously observed fabric fraying around the fenestration as a result of the balloon angioplasty of the seal zone.This novel stent cuff design will also facilitate more complete biointegration of the devices,eliminate the hemodynamic variation as well as significantly reduce the possibility of a Type III endoleak.The feasibility of this concept is demonstrated by observations made from in-situ tests performed in a Beta endograft design.Flared cuffs made of poly(ε-caprolactone)supported with a weft-knitted polyester structure can be manufactured with various configurations to optimize the transition from the main body of the endograft,thus preventing the currently marketed designs’hemodynamic perturbation while also promoting endograft biointegration.This concept represents an evolution in branch graft design,which may enhance the long-term durability of customized fenestrations and open new applications for in-vivo graft fenestration in the near future.Further ongoing investigation to optimize its structure,X-ray opacity,fixation to the flared stent,and material biocompatibility are still required to build upon this concept’s proof.