An optical fiber bienzyme sensor based on the luminol chemiluminescent reaction was developed and demonstrated to be sensitive to glucose. Glucose oxidase(GOD) and horseradish peroxidase(HRP) were co-immobilized by mi...An optical fiber bienzyme sensor based on the luminol chemiluminescent reaction was developed and demonstrated to be sensitive to glucose. Glucose oxidase(GOD) and horseradish peroxidase(HRP) were co-immobilized by microencapsulation in a sol-gel film derived from tetraethyl orthosilicate(TEOS). The calibration plots for glucose were established by the optical fiber glucose sensor fabricated by attaching the bienzyme silica gel onto the glass window of the fiber bundle. The linear range was 0 2-2 mmol/L and the detection limit was approximately 0 12 mmol/L. The relative standard deviation was 5.3% ( n =6). The proposed biosensor was applied to glucose assay in ofloxacin injection successfully.展开更多
Luciferase from firefly lantern extract was immobilized on CNBr activated Sepharose 4B. The kinetic properties of immobilized luciferase were extensively studied. The K m′ for D luciferin is 11.9 μmol/L, the ...Luciferase from firefly lantern extract was immobilized on CNBr activated Sepharose 4B. The kinetic properties of immobilized luciferase were extensively studied. The K m′ for D luciferin is 11.9 μmol/L, the optimum pH and temperature for Sepharose bound enzyme were 7.8 and 25℃ respectively. A luminescence fiber optic biosensor, making use of immobilized crude luciferase, was developed for assay of ATP. The peak light intensity was linear with respect to ATP concentration in range of 10 -9 -10 -5 mol/L. A biological application was also demonstrated with the determination of serum ATP from rats bred in low versus normal oxygen environments.展开更多
文摘An optical fiber bienzyme sensor based on the luminol chemiluminescent reaction was developed and demonstrated to be sensitive to glucose. Glucose oxidase(GOD) and horseradish peroxidase(HRP) were co-immobilized by microencapsulation in a sol-gel film derived from tetraethyl orthosilicate(TEOS). The calibration plots for glucose were established by the optical fiber glucose sensor fabricated by attaching the bienzyme silica gel onto the glass window of the fiber bundle. The linear range was 0 2-2 mmol/L and the detection limit was approximately 0 12 mmol/L. The relative standard deviation was 5.3% ( n =6). The proposed biosensor was applied to glucose assay in ofloxacin injection successfully.
文摘Luciferase from firefly lantern extract was immobilized on CNBr activated Sepharose 4B. The kinetic properties of immobilized luciferase were extensively studied. The K m′ for D luciferin is 11.9 μmol/L, the optimum pH and temperature for Sepharose bound enzyme were 7.8 and 25℃ respectively. A luminescence fiber optic biosensor, making use of immobilized crude luciferase, was developed for assay of ATP. The peak light intensity was linear with respect to ATP concentration in range of 10 -9 -10 -5 mol/L. A biological application was also demonstrated with the determination of serum ATP from rats bred in low versus normal oxygen environments.