In this study, 16 patients (19 eyes) with nonarteritic anterior ischemic optic neuropathy in the acute stage (within 4 weeks) and resolving stage (after 12 weeks) were diagnosed by a series of complete ophthalmi...In this study, 16 patients (19 eyes) with nonarteritic anterior ischemic optic neuropathy in the acute stage (within 4 weeks) and resolving stage (after 12 weeks) were diagnosed by a series of complete ophthalmic examinations, including fundus examination, optical coherence tomography and fluorescein fundus angiography, and visual field defects were measured with standard automated perimetry. The contralateral uninvolved eyes were used as controls. The retinal nerve fiber layer thickness was determined by optical coherence tomography which showed that the mean retinal nerve fiber layer thickness and the retinal nerve fiber layer thickness from temporal, superior, nasal and inferior quadrants were significantly higher for all measurements in the acute stage than the corresponding normal values. In comparison, the retinal nerve fiber layer thickness from each optic disc quadrant was found to be significantly lower when measured at the resolving stages, than in the control group. Statistical analysis on the correlation between optic disc nerve fiber layer thickness and visual defects demonstrated a positive correlation in the acute stage and a negative correlation in the resolving stage. Our experimental findings indicate that optical coherence tomography is a useful diagnostic method for nonarteritic anterior ischemic optic neuropathy and can be used to evaluate the effect of treatment.展开更多
In this review, we summarize the progression of several parameters assessed by spectral-domain optical coherence tomography (SD-OCT) in recent years for the detection of glaucoma. Monitoring the progression of defec...In this review, we summarize the progression of several parameters assessed by spectral-domain optical coherence tomography (SD-OCT) in recent years for the detection of glaucoma. Monitoring the progression of defects in the retinal nerve fiber layer (RNFL) thickness is essential. Imaging and analysis of retinal ganglion cells (RGCs) and inner plexiform layer (IPL), respectively, have been of great importance. Optic nerve head (ONH) topography obtained from 3D SD-OCT images is another crucial step. Other important assessments involve locating the Bruch's membrane opening (BMO), estimating the optic disc size and rim area, and measuring the lamina cribrosa displacement. Still other parameters found in the past three years for glaucoma diagnosis comprise central retinal artery resistive index, optic disc perfusion in optical coherence tomography angiography (OCTA) study, peripapillary choroidal thickness, and choroidal area in SD-OCT. Recently, several more ocular fundus parameters have been found, and compared with the earlier parameters to judge the accuracy of diagnosis. While a few of these parameters have been widely used in clinical practice, a fair number are still in the experimental stage.展开更多
基金supported by the National Natural Science Foundation of China,No.81173440the Natural Science Foundation of Shandong Province,No.ZR2009CL038
文摘In this study, 16 patients (19 eyes) with nonarteritic anterior ischemic optic neuropathy in the acute stage (within 4 weeks) and resolving stage (after 12 weeks) were diagnosed by a series of complete ophthalmic examinations, including fundus examination, optical coherence tomography and fluorescein fundus angiography, and visual field defects were measured with standard automated perimetry. The contralateral uninvolved eyes were used as controls. The retinal nerve fiber layer thickness was determined by optical coherence tomography which showed that the mean retinal nerve fiber layer thickness and the retinal nerve fiber layer thickness from temporal, superior, nasal and inferior quadrants were significantly higher for all measurements in the acute stage than the corresponding normal values. In comparison, the retinal nerve fiber layer thickness from each optic disc quadrant was found to be significantly lower when measured at the resolving stages, than in the control group. Statistical analysis on the correlation between optic disc nerve fiber layer thickness and visual defects demonstrated a positive correlation in the acute stage and a negative correlation in the resolving stage. Our experimental findings indicate that optical coherence tomography is a useful diagnostic method for nonarteritic anterior ischemic optic neuropathy and can be used to evaluate the effect of treatment.
基金Supported by the National Natural Science Foundation of China(No.81300755)the Key Project of the Natural Science Foundation of the Higher Educational Bureau of Anhui Province(No.KJ2013A147)
文摘In this review, we summarize the progression of several parameters assessed by spectral-domain optical coherence tomography (SD-OCT) in recent years for the detection of glaucoma. Monitoring the progression of defects in the retinal nerve fiber layer (RNFL) thickness is essential. Imaging and analysis of retinal ganglion cells (RGCs) and inner plexiform layer (IPL), respectively, have been of great importance. Optic nerve head (ONH) topography obtained from 3D SD-OCT images is another crucial step. Other important assessments involve locating the Bruch's membrane opening (BMO), estimating the optic disc size and rim area, and measuring the lamina cribrosa displacement. Still other parameters found in the past three years for glaucoma diagnosis comprise central retinal artery resistive index, optic disc perfusion in optical coherence tomography angiography (OCTA) study, peripapillary choroidal thickness, and choroidal area in SD-OCT. Recently, several more ocular fundus parameters have been found, and compared with the earlier parameters to judge the accuracy of diagnosis. While a few of these parameters have been widely used in clinical practice, a fair number are still in the experimental stage.