It is challenging to make an ultrafast diagnosis of the temporal evolution of small and short-lived plasma in two dimensions. To overcome this difficulty, we have developed a well-timed diagnostic utilizing an x-ray s...It is challenging to make an ultrafast diagnosis of the temporal evolution of small and short-lived plasma in two dimensions. To overcome this difficulty, we have developed a well-timed diagnostic utilizing an x-ray streak camera equipped with a row of multi-pinhole arrays. By processing multiple sets of one-dimensional streaked image data acquired from various pinholes, we are capable of reconstructing high-resolution two-dimensional images with a temporal resolution of 38 ps and a spatial resolution of 18 μm. The temporal fiducial pulses accessed from external sources can advance the precise timing and accurately determine the arrival time of the laser. Moreover, it can correct the nonlinear sweeping speed of the streak camera. The effectiveness of this diagnostic has been successfully verified at the Shenguang-II laser facility,providing an indispensable tool for observing complex physical phenomena, such as the implosion process of laser-fusion experiments.展开更多
Objective This study aims to quantify the uncertainties of CyberKnife Synchrony fiducial tracking for liver stereotactic body radiation therapy(SBRT)cases,and evaluate the required planning target volume(PTV)margins.M...Objective This study aims to quantify the uncertainties of CyberKnife Synchrony fiducial tracking for liver stereotactic body radiation therapy(SBRT)cases,and evaluate the required planning target volume(PTV)margins.Methods A total of 11 liver tumor patients with a total of 57 fractions,who underwent SBRT with synchronous fiducial tracking,were enrolled for the present study.The correlation/prediction model error,geometric error,and beam targeting error were quantified to determine the patient-level and fraction-level individual composite treatment uncertainties.The composite uncertainties and multiple margin recipes were compared for scenarios with and without rotation correction during treatment.Results The correlation model error-related uncertainty was 4.3±1.8,1.4±0.5 and 1.8±0.7 mm in the superior-inferior(SI),left-right,and anterior-posterior directions,respectively.These were the primary contributors among all uncertainty sources.The geometric error significantly increased for treatments without rotation correction.The fraction-level composite uncertainties had a long tail distribution.Furthermore,the generally used 5-mm isotropic margin covered all uncertainties in the left-right and anterior-posterior directions,and only 75%of uncertainties in the SI direction.In order to cover 90%of uncertainties in the SI direction,an 8-mm margin would be needed.For scenarios without rotation correction,additional safety margins should be added,especially in the superior-inferior and anterior-posterior directions.Conclusion The present study revealed that the correlation model error contributes to most of the uncertainties in the results.Most patients/fractions can be covered by a 5-mm margin.Patients with large treatment uncertainties might need a patient-specific margin.展开更多
基金supported by the Strategic Priority Research Program of the Chinese Academy of Sciences (Grant Nos. XDA25030700 and XDA25030500)the National Key R&D Program of China (Grant Nos. 2022YFA1603200 and 2022YFA1603203)the National Natural Science Foundation of China (Grant Nos. 12175018, 12135001, 12075030, and 11903006)。
文摘It is challenging to make an ultrafast diagnosis of the temporal evolution of small and short-lived plasma in two dimensions. To overcome this difficulty, we have developed a well-timed diagnostic utilizing an x-ray streak camera equipped with a row of multi-pinhole arrays. By processing multiple sets of one-dimensional streaked image data acquired from various pinholes, we are capable of reconstructing high-resolution two-dimensional images with a temporal resolution of 38 ps and a spatial resolution of 18 μm. The temporal fiducial pulses accessed from external sources can advance the precise timing and accurately determine the arrival time of the laser. Moreover, it can correct the nonlinear sweeping speed of the streak camera. The effectiveness of this diagnostic has been successfully verified at the Shenguang-II laser facility,providing an indispensable tool for observing complex physical phenomena, such as the implosion process of laser-fusion experiments.
基金This project was supported by the National Key R&D Program of China(No.2016YFC105300).
文摘Objective This study aims to quantify the uncertainties of CyberKnife Synchrony fiducial tracking for liver stereotactic body radiation therapy(SBRT)cases,and evaluate the required planning target volume(PTV)margins.Methods A total of 11 liver tumor patients with a total of 57 fractions,who underwent SBRT with synchronous fiducial tracking,were enrolled for the present study.The correlation/prediction model error,geometric error,and beam targeting error were quantified to determine the patient-level and fraction-level individual composite treatment uncertainties.The composite uncertainties and multiple margin recipes were compared for scenarios with and without rotation correction during treatment.Results The correlation model error-related uncertainty was 4.3±1.8,1.4±0.5 and 1.8±0.7 mm in the superior-inferior(SI),left-right,and anterior-posterior directions,respectively.These were the primary contributors among all uncertainty sources.The geometric error significantly increased for treatments without rotation correction.The fraction-level composite uncertainties had a long tail distribution.Furthermore,the generally used 5-mm isotropic margin covered all uncertainties in the left-right and anterior-posterior directions,and only 75%of uncertainties in the SI direction.In order to cover 90%of uncertainties in the SI direction,an 8-mm margin would be needed.For scenarios without rotation correction,additional safety margins should be added,especially in the superior-inferior and anterior-posterior directions.Conclusion The present study revealed that the correlation model error contributes to most of the uncertainties in the results.Most patients/fractions can be covered by a 5-mm margin.Patients with large treatment uncertainties might need a patient-specific margin.