[Objective] This study aimed to make use of the limited filamentous sludge bulking characteristics to purify water quality and save energy. [Method] The effects of dissolved oxygen (DO) on sludge bulking were explor...[Objective] This study aimed to make use of the limited filamentous sludge bulking characteristics to purify water quality and save energy. [Method] The effects of dissolved oxygen (DO) on sludge bulking were explored by changing the DO con- centration in the aerobiotic pool of NO system from the low load (0.25 kg COD/(kg MLSS.d)) and the medium to high load (0.55 kgCOD/(kg MLSSod)). [Result] In the NO activated sludge system, when the sludge load was 0.25 kg COD/(kg MLSS.d), DO=1.5 mg/L, the sludge index was at around 250, while when the sludge load- ing was 0.55 kg COD/(kg MLSS.d), DO=1.5 mg/L, the sludge index was close to 300, occurring the limited filamentous bulking. The bulked sludge still showed high removal rates to COD, SS, nitrogen and phosphorus. [Conclusion] It could improve the oxygen transfer rate and reduce the aeration rate at low DO conditions to achieve energy-saving.展开更多
基金Supported by the National Natural Science Foundation of China(51208068)~~
文摘[Objective] This study aimed to make use of the limited filamentous sludge bulking characteristics to purify water quality and save energy. [Method] The effects of dissolved oxygen (DO) on sludge bulking were explored by changing the DO con- centration in the aerobiotic pool of NO system from the low load (0.25 kg COD/(kg MLSS.d)) and the medium to high load (0.55 kgCOD/(kg MLSSod)). [Result] In the NO activated sludge system, when the sludge load was 0.25 kg COD/(kg MLSS.d), DO=1.5 mg/L, the sludge index was at around 250, while when the sludge load- ing was 0.55 kg COD/(kg MLSS.d), DO=1.5 mg/L, the sludge index was close to 300, occurring the limited filamentous bulking. The bulked sludge still showed high removal rates to COD, SS, nitrogen and phosphorus. [Conclusion] It could improve the oxygen transfer rate and reduce the aeration rate at low DO conditions to achieve energy-saving.