期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
A low-noise widely tunable Gm-C filter with frequency calibration
1
作者 王彧 刘静 +1 位作者 闫娜 闵昊 《Journal of Semiconductors》 EI CAS CSCD 2016年第9期88-95,共8页
A fourth-order Gm-C Chebyshev low-pass filter is presented as channel selection filter for reconfigurable multi-mode wireless receivers. Low-noise technologies are proposed in optimizing the noise characteristics of b... A fourth-order Gm-C Chebyshev low-pass filter is presented as channel selection filter for reconfigurable multi-mode wireless receivers. Low-noise technologies are proposed in optimizing the noise characteristics of both the Gm cells and the filter topology. A frequency tuning strategy is used by tuning both the transconductance of the Gm cells and the capacitance of the capacitor banks. To achieve accurate cut-off frequencies, an on-chip calibration circuit is presented to compensate for the frequency inaccuracy introduced by process variation. The filter is fabricated in a 0.13 m CMOS process. It exhibits a wide programmable bandwidth from 322.5 k Hz to20 MHz. Measured results show that the filter has low input referred noise of 5.9 n V/(Hz)^(1/2) and high out-of-band IIP3 of 16.2 d Bm. It consumes 4.2 and 9.5 m W from a 1 V power supply at its lowest and highest cut-off frequencies respectively. 展开更多
关键词 Gm-C filter CMOS technology operational transconductance amplifier low noise frequency calibration
原文传递
A Wavelength Monitoring System Using Tunable MEMS Filter Calibrated by F-P Laser
2
作者 H. Y. Tam P. K. A. Wai W. H. Chung 《光学学报》 EI CAS CSCD 北大核心 2003年第S1期615-616,共2页
We report a wavelength and power monitoring system based on a scanning MEMS filter as wavelength discriminator and a near threshold-biased Fabry-Perot diode laser as wavelength reference. This system is capable of mon... We report a wavelength and power monitoring system based on a scanning MEMS filter as wavelength discriminator and a near threshold-biased Fabry-Perot diode laser as wavelength reference. This system is capable of monitoring 250 channels of DWDM signal at 25 GHz ITU Grid with an error of less than ±8 pm. 展开更多
关键词 DWDM FP LD MEMS A Wavelength Monitoring System Using Tunable MEMS filter Calibrated by F-P Laser by
原文传递
Magnetometer Compensation Scheme and Experimental Results on ZDPS-1A Pico-satellite 被引量:3
3
作者 HAN Ke WANG Hao +1 位作者 XIANG Tian JIN Zhonghe 《Chinese Journal of Aeronautics》 SCIE EI CSCD 2012年第3期430-436,共7页
In a pico-satellite with small volume, measurements from on-board three-axis magnetometer (TAM) are not accurate, as it can be easily disturbed by other electronic systems. To improve its accuracy, a scheme of compe... In a pico-satellite with small volume, measurements from on-board three-axis magnetometer (TAM) are not accurate, as it can be easily disturbed by other electronic systems. To improve its accuracy, a scheme of compensation methods is introduced in this article. The scheme is based on an improved meast, rement model of pico-satellite TAM, and it mainly consists of three steps. First, in satellite design stage, several techniques are recommended to simplify the afterwards compensations. Then after satellite assembly, TAM ground tests and pre-launch calibration with least-square batch filter are introduced to improve magnetometer performance. At the end, a post-launch calibration with unscented Kalman filter (UKF) is implemented with in-orbit data. The compensation scheme is used in the development of Chinese pico-satellite ZDPS-1A made by Zhejiang University. Results show that with the introduced compensation scheme, the maximum error of ZDPS-1A TAM can be reduced from 80 mG to 6 naG (1 G=10^-4T). 展开更多
关键词 pico-satellite MAGNETOMETERS calibration least-square filter Kalman filter
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部