We present a detailed catalog of 13671 earthquakes in the Eastern Tennessee Seismic Zone(ETSZ)that spans January 1,2005 to July 31,2020.We apply a matched filter detection technique on over 15 years of continuous data...We present a detailed catalog of 13671 earthquakes in the Eastern Tennessee Seismic Zone(ETSZ)that spans January 1,2005 to July 31,2020.We apply a matched filter detection technique on over 15 years of continuous data,resulting in arguably the most complete catalog of seismicity in the ETSZ yet.The magnitudes of newly detected events are determined by computing the amplitude ratio between the detections and templates using a principal component fit.We also compute the b-value for the new catalog and comparatively relocate a subset of newly detected events using XCORLOC and hypoDD,which shows a more defined structure at depth.We find the greatest concentration along and to the east of the New York-Alabama Lineament,as defined by the magnetic anomaly,supporting the argument that this feature likely is related to the generation of seismicity in the ETSZ.We examine seismicity in the vicinity of the Watts Bar Reservoir,which is located about 5 km from the epicenter of the M_(W) 4.4 December 12,2018 Decatur,Tennessee earthquake,and find possible evidence for reservoir modulated seismicity in this region.We also examine seismicity in the entire ETSZ to search for a correlation between shallow earthquakes and seasonal hydrologic changes.Our results show limited evidence for hydrologicallydriven shallow seismicity due to seasonal groundwater levels in the ETSZ,which contradicts previous studies hypothesizing that most intraplate earthquakes are associated with the dynamics of hydrologic cycles.展开更多
In this paper, the robust fault detection filter (RFDF) design problems are studied for nonlinear time-delay systems with unknown inputs. First, a reference residual model is introduced to formulate the RFDF design pr...In this paper, the robust fault detection filter (RFDF) design problems are studied for nonlinear time-delay systems with unknown inputs. First, a reference residual model is introduced to formulate the RFDF design problem as an H∞ model-matching problem. Then appropriate input/output selection matrices are introduced to extend a performance index to the time-delay systems in time domain. The reference residual model designed according to the performance index is an optimal residual generator, which takes into account the robustness against disturbances and sensitivity to faults simultaneously. Applying robust H∞ optimization control technique, the existence conditions of the RFDF for nonlinear time-delay systems with unknown inputs are presented in terms of linear matrix inequality (LMI) formulation, independently of time delay. An illustrative design example is used to demonstrate the validity and applicability of the proposed approach.展开更多
Problems related to the design of observer-based parametric fault detection(PFD) systems are studied. The core of our study is to first describe the faults occurring in systemactuators, sensors and components in the f...Problems related to the design of observer-based parametric fault detection(PFD) systems are studied. The core of our study is to first describe the faults occurring in systemactuators, sensors and components in the form of additive parameter deviations, then to transformthe PFD problems into a similar additive fault setup, based on which an optimal observer-basedoptimization fault detection approach is proposed. A constructive solution optimal in the sense ofminimizing a certain performance index is developed. The main results consist of defining parametricfault detectability, formulating a PFD optimization problem and its solution. A numerical exampleto demonstrate the effectiveness of the proposed approach is provided.展开更多
The problem of fault detection for linear discrete timevarying systems with multiplicative noise is dealt with.By using an observer-based robust fault detection filter(FDF) as a residual generator,the design of the ...The problem of fault detection for linear discrete timevarying systems with multiplicative noise is dealt with.By using an observer-based robust fault detection filter(FDF) as a residual generator,the design of the FDF is formulated in the framework of H ∞ filtering for a class of stochastic time-varying systems.A sufficient condition for the existence of the FDF is derived in terms of a Riccati equation.The determination of the parameter matrices of the filter is converted into a quadratic optimization problem,and an analytical solution of the parameter matrices is obtained by solving the Riccati equation.Numerical examples are given to illustrate the effectiveness of the proposed method.展开更多
Building energy consumption accounts for nearly 40% of global energy consumption, HVAC (Heating, Ventilating, and Air Conditioning) systems are the major building energy consumers, and as one type of HVAC systems, t...Building energy consumption accounts for nearly 40% of global energy consumption, HVAC (Heating, Ventilating, and Air Conditioning) systems are the major building energy consumers, and as one type of HVAC systems, the heat pump air conditioning system, which is more energy-efficient compared to the traditional air conditioning system, is being more widely used to save energy. However, in northern China, extreme climatic conditions increase the cooling and heating load of the heat pump air conditioning system and accelerate the aging of the equipment, and the sensor may detect drifted parameters owing to climate change. This non-linear drifted parameter increases the false alarm rate of the fault detection and the need for unnecessary troubleshooting. In order to overcome the impact of the device aging and the drifted parameter, a Kalman filter and SPC (statistical process control) fault detection method are introduced in this paper. In this method, the model parameter and its standard variance can he estimated by Kalman filter based on the gray model and the real-time data of the air conditioning system. Further, by using SPC to construct the dynamic control limits, false alarm rate is reduced. And this paper mainly focuses on the cold machine failure in the component failure and its soft fault detection. This approach has been tested on a simulation model of the "Sino-German Energy Conservation Demonstration Center" building heat pump air-conditioning system in Shenyang, China, and the results show that the Kalman filter and SPC fault detection method is simple and highly efficient with a low false alarm rate, and it can deal with the difficulties caused by the extreme environment and the non-linear influence of the parameters, and what's more, it provides a good foundation for dynamic fault diagnosis and fault prediction analysis.展开更多
In this paper,the fault detection filter(FDF) design problem for networked control systems(NCSs) with both network-induced delay and data dropout is studied.Based on a new NCSs model proposed recently,an observer-base...In this paper,the fault detection filter(FDF) design problem for networked control systems(NCSs) with both network-induced delay and data dropout is studied.Based on a new NCSs model proposed recently,an observer-based filter is introduced to be the residual generator and formulated as an H∞-optimization problem for systems with two successive delay components.By applying Lyapunov-Krasovskii approach,a new sufficient condition on stability and H∞ performance is derived for systems with two successive delay components in the state.A solution of the optimization problem is then presented in terms of linear matrix inequality(LMI) formulation,dependently of time delay.In order to detect the fault,the residual evaluation problem is also considered.An illustrative design example is employed to demonstrate the validity of the proposed approach.展开更多
The problem of the robust fault detection filter design for time-varying delays switched systems is considered in the framework of mixed H-/H∞. Firstly, the weighted H∞ performance index is utilized as the robustnes...The problem of the robust fault detection filter design for time-varying delays switched systems is considered in the framework of mixed H-/H∞. Firstly, the weighted H∞ performance index is utilized as the robustness performance, and the H- index is used as the sensitivity performance for obtaining the robust fault detection filter. Then a novel multiple Lyapunov-Krasovskii function is proposed for deriving sufficient existence conditions of the robust fault detection filter based on the average dwell time technique. By introducing slack matrix variable, the coupling between the Lyapunov matrix and system matrix is removed, and the conservatism of results is reduced. Based on the robust fault detection filter, residual is generated and evaluated for detecting faults. In addition, the results of this paper are dependent on time delays,and represented in the form of linear matrix inequalities. Finally,the simulation example verifies the effectiveness of the proposed method.展开更多
This paper deals with the problem of optimal fault detection filter (FDF) design for a class of discrete-time switched linear systems under arbitrary switching. By using an observer-based FDF as a residual generator...This paper deals with the problem of optimal fault detection filter (FDF) design for a class of discrete-time switched linear systems under arbitrary switching. By using an observer-based FDF as a residual generator, the design of the FDF is formulated into an optimization problem through maximizing the H_/H∞ or H∞/H∞ performance index. With the aid of an operator optimization method, it is shown that a mode-dependent unified optimal solution can be derived by solving a coupled Riccati equation. A numerical example is given to show the effectiveness of the proposed method.展开更多
Signals from infrared detector are very weak in SO2 concentration measuring system.In order to improve the sensitivity of detection,combining with filter correlation technology and infrared absorption principle,the we...Signals from infrared detector are very weak in SO2 concentration measuring system.In order to improve the sensitivity of detection,combining with filter correlation technology and infrared absorption principle,the weak signal processing circuit is designed according to correlation detection technology.Under laboratory conditions,system performance of SO2 concentration is tested,and the experimental data are analyzed and processed.Then relationship of SO2 concentration and the measuring voltage is provided to prove that the design improves measuring sensitivity of the system.展开更多
In the normal operation condition, a conventional square-root cubature Kalman filter (SRCKF) gives sufficiently good estimation results. However, if the measurements are not reliable, the SRCKF may give inaccurate r...In the normal operation condition, a conventional square-root cubature Kalman filter (SRCKF) gives sufficiently good estimation results. However, if the measurements are not reliable, the SRCKF may give inaccurate results and diverges by time. This study introduces an adaptive SRCKF algorithm with the filter gain correction for the case of measurement malfunctions. By proposing a switching criterion, an optimal filter is selected from the adaptive and conventional SRCKF according to the measurement quality. A subsystem soft fault detection algorithm is built with the filter residual. Utilizing a clear subsystem fault coefficient, the faulty subsystem is isolated as a result of the system reconstruction. In order to improve the performance of the multi-sensor system, a hybrid fusion algorithm is presented based on the adaptive SRCKF. The state and error covariance matrix are also predicted by the priori fusion estimates, and are updated by the predicted and estimated information of subsystems. The proposed algorithms were applied to the vessel dynamic positioning system simulation. They were compared with normal SRCKF and local estimation weighted fusion algorithm. The simulation results show that the presented adaptive SRCKF improves the robustness of subsystem filtering, and the hybrid fusion algorithm has the better performance. The simulation verifies the effectiveness of the proposed algorithms.展开更多
The ultrasonic testing for the defects of complete disbond in multi-layered structure with lower acoustic impedance beneath a high acoustic impedance overburden is one of the difficult problems in ultrasonic nondestru...The ultrasonic testing for the defects of complete disbond in multi-layered structure with lower acoustic impedance beneath a high acoustic impedance overburden is one of the difficult problems in ultrasonic nondestructive testing field. A model of a multi-layered steel-rubber composite plate is depicted. Because the acoustic impedance of the steel differs far from that of the couplant water and the rubber, the energy of the signal reflected from the debonded rubber layers is very weak. More over, the flaw echoes are masked by the strong echoes reverberated in the steel plate. It's nearly impossible to identify the debonding echoes directly. The subband adaptive filtering method is discussed in the paper, where the subband decomposition is performed by mutual wavelet packets decomposition on the criterion of maximizing the cross-correlation between the signals. The simulations on both synthetic and real signals are presented. The echoes from the delaminated flaw at the depth of 5 mm in the rubber from the calculated signal, and echoes from the flaw at the depth of 3 mm from the real signal are extracted successfully.展开更多
In order to improve the accuracy of free flight conflict detection and reduce the false alarm rate, an improved flight conflict detection algorithm is proposed based on Gauss-Hermite particle filter(GHPF). The algor...In order to improve the accuracy of free flight conflict detection and reduce the false alarm rate, an improved flight conflict detection algorithm is proposed based on Gauss-Hermite particle filter(GHPF). The algorithm improves the traditional flight conflict detection method in two aspects:(i) New observation data are integrated into system state transition probability, and Gauss-Hermite Filter(GHF) is used for generating the importance density function.(ii) GHPF is used for flight trajectory prediction and flight conflict probability calculation. The experimental results show that the accuracy of conflict detection and tracing with GHPF is better than that with standard particle filter. The detected conflict probability is more precise with GHPF, and GHPF is suitable for early free flight conflict detection.展开更多
This paper is concerned with the robust fault detection filter (RFDF) design for a class of linear time- invariant systems (LTISs) with output state time delays. Although existing results in literatures study the ...This paper is concerned with the robust fault detection filter (RFDF) design for a class of linear time- invariant systems (LTISs) with output state time delays. Although existing results in literatures study the RFDF for time- delay systems, few is concerned with the output state time-delay systems. The basic idea of our study is to eliminate the time delays of system and transform it to a delay-free system (i.e., a linear time-invariant system without time delays) by the bicausal change of coordinates approach. Then, we design the RFDF for the delay-free LTIS, which is equivalent to the original system with time delays. We first introduce a class of systems with output state time delays, whose fault can be detected by using the RFDF design approach for delay-free systems. Then, since the RFDF design problem can be formulated as a standard H-infinity-model matching problem, it is solved by using H-infinity-optimization LMI techniques. In the last, the adaptive threshold of fault detection is chosen and an illustrative design example is used to demonstrate the validity of the design approach.展开更多
In this paper, an approach for designing robust fault detection filter (RFDF) of networked control systems (NCSs) with unknown inputs is studied. The design aims at implementing the optimal trade-off between robustnes...In this paper, an approach for designing robust fault detection filter (RFDF) of networked control systems (NCSs) with unknown inputs is studied. The design aims at implementing the optimal trade-off between robustness of unknown inputs (including the item produced by networked-induced delay) and sensitivity of fault. The key design issue is to introduce an optimal fault detection filter based on NCSs with the control law compensation as the reference residual model of NCSs and to formulate the RFDF design as a model-matching problem. By applying H∞ optimization technique, linear matrix inequality (LMI) approach is given to solve the model-matching problem. The validity of the proposed approach is shown by a numerical example.展开更多
Echo cancellation plays an important role in current Internet protocol(IP) based voice interactive systems. Voice state detection is an essential part in echo cancellation. It mainly comprises two parts: double tal...Echo cancellation plays an important role in current Internet protocol(IP) based voice interactive systems. Voice state detection is an essential part in echo cancellation. It mainly comprises two parts: double talk detection(DTD) and voice activity detection(VAD). DTD is used to detect doubletalk and prevent filter divergence in the presence of near-end speech, and VAD is used to determine the near-end voice activity and output silence indicator when near-end is silent. However, DTD straightforwardly proceeded may mistakenly declare double talk under double silent condition, coefficients update under the far-end silence condition may lead to filter divergence, and current VAD algorithms may misjudge the residual echo from the near end to be far-end voice. Therefore, a voice detection algorithm combining DTD and far-end VAD is proposed. DTD is implemented when VAD declares far-end speech, filtering and coefficients update will be halted when VAD declares far-end silence, and the far-end VAD adopted is multi-feature VAD based on short-time energy and correlation. The new algorithm can improve the accuracy of DTD, prevent filter divergence, and exclude the circumstance that far-end signal only contains residual echo from near end. Actual test results show that the voice state decision of the new algorithm is accurate, and the performance of echo cancellation is improved.展开更多
Aiming to the reliable estimates of the ionosphere differential corrections for the satellite navigation system in the presence of the ionosphere anomaly, a fault-tolerance estimating method, which is based on the dis...Aiming to the reliable estimates of the ionosphere differential corrections for the satellite navigation system in the presence of the ionosphere anomaly, a fault-tolerance estimating method, which is based on the distributed Kalman filtering, is proposed. The method utilizes the parallel sub-filters for estimating the ionosphere differential corrections. Meanwhile, an infinite norm (IN) method is proposed for the detection of the ionosphere irregularity in the filter processing. Once the anomaly is detected, the sub-filter contaminated by the anomaly measurements will be excluded to ensure the reliability of the estimates. The simulation is conducted to validate the method and the results indicate that the anomaly can be found timely due to the novel fault detection method based on the infinite norm. Because of the parallel sub-filter architecture, the measurements are classified by the spatial distribution so that the ionosphere anomaly can be positioned and excluded more easily. Thus, the method can provide the robust and accurate ionosphere differential corrections.展开更多
Based on the classic filter of progressive triangulated irregular network(TIN) densification, an improved filter is proposed in this paper. In this method, we divide ground points into grids with certain size and se...Based on the classic filter of progressive triangulated irregular network(TIN) densification, an improved filter is proposed in this paper. In this method, we divide ground points into grids with certain size and select the lowest points in the grids to reconstruct TIN in the process of iteration. Compared with the classic filter of progressive TIN densification(PTD), the improved method can filter out attached objects, avoid the interference of low objects and obtain relatively smooth bare-earth. In addition, this proposed filter can reduce memory requirements and be more efficient in processing huge data volume. The experimental results show that the filtering accuracy and efficiency of this method is higher than that of the PTD method.展开更多
基金supported by USGS NHERP grant G20AP00039Matched Filter detection was run on the Extreme Science and Engineering Discovery Environment (XSEDE), which is supported by National Science Foundation (NSF) grant number ACI-1548562it used the Bridges system, which is supported by NSF award number ACI-1445606, at the Pittsburgh Supercomputing Center (PSC).
文摘We present a detailed catalog of 13671 earthquakes in the Eastern Tennessee Seismic Zone(ETSZ)that spans January 1,2005 to July 31,2020.We apply a matched filter detection technique on over 15 years of continuous data,resulting in arguably the most complete catalog of seismicity in the ETSZ yet.The magnitudes of newly detected events are determined by computing the amplitude ratio between the detections and templates using a principal component fit.We also compute the b-value for the new catalog and comparatively relocate a subset of newly detected events using XCORLOC and hypoDD,which shows a more defined structure at depth.We find the greatest concentration along and to the east of the New York-Alabama Lineament,as defined by the magnetic anomaly,supporting the argument that this feature likely is related to the generation of seismicity in the ETSZ.We examine seismicity in the vicinity of the Watts Bar Reservoir,which is located about 5 km from the epicenter of the M_(W) 4.4 December 12,2018 Decatur,Tennessee earthquake,and find possible evidence for reservoir modulated seismicity in this region.We also examine seismicity in the entire ETSZ to search for a correlation between shallow earthquakes and seasonal hydrologic changes.Our results show limited evidence for hydrologicallydriven shallow seismicity due to seasonal groundwater levels in the ETSZ,which contradicts previous studies hypothesizing that most intraplate earthquakes are associated with the dynamics of hydrologic cycles.
基金Project (No. 60574081) supported by the National Natural ScienceFoundation of China
文摘In this paper, the robust fault detection filter (RFDF) design problems are studied for nonlinear time-delay systems with unknown inputs. First, a reference residual model is introduced to formulate the RFDF design problem as an H∞ model-matching problem. Then appropriate input/output selection matrices are introduced to extend a performance index to the time-delay systems in time domain. The reference residual model designed according to the performance index is an optimal residual generator, which takes into account the robustness against disturbances and sensitivity to faults simultaneously. Applying robust H∞ optimization control technique, the existence conditions of the RFDF for nonlinear time-delay systems with unknown inputs are presented in terms of linear matrix inequality (LMI) formulation, independently of time delay. An illustrative design example is used to demonstrate the validity and applicability of the proposed approach.
文摘Problems related to the design of observer-based parametric fault detection(PFD) systems are studied. The core of our study is to first describe the faults occurring in systemactuators, sensors and components in the form of additive parameter deviations, then to transformthe PFD problems into a similar additive fault setup, based on which an optimal observer-basedoptimization fault detection approach is proposed. A constructive solution optimal in the sense ofminimizing a certain performance index is developed. The main results consist of defining parametricfault detectability, formulating a PFD optimization problem and its solution. A numerical exampleto demonstrate the effectiveness of the proposed approach is provided.
基金supported by the National Natural Science Foundation of China (61174121,61121003)the National High Technology Researchand Development Program of China (863 Program) (2008AA121302)+1 种基金the National Basic Research Program of China (973 Program)(2009CB724000)the Research Fund for the Doctoral Program of Higher Education of China
文摘The problem of fault detection for linear discrete timevarying systems with multiplicative noise is dealt with.By using an observer-based robust fault detection filter(FDF) as a residual generator,the design of the FDF is formulated in the framework of H ∞ filtering for a class of stochastic time-varying systems.A sufficient condition for the existence of the FDF is derived in terms of a Riccati equation.The determination of the parameter matrices of the filter is converted into a quadratic optimization problem,and an analytical solution of the parameter matrices is obtained by solving the Riccati equation.Numerical examples are given to illustrate the effectiveness of the proposed method.
基金Supported by the National Natural Science Foundation Committee of China(61503259)China Postdoctoral Science Foundation Funded Project(2017M611261)+1 种基金Chinese Scholarship Council(201608210107)Hanyu Plan of Shenyang Jianzhu University(XKHY2-64)
文摘Building energy consumption accounts for nearly 40% of global energy consumption, HVAC (Heating, Ventilating, and Air Conditioning) systems are the major building energy consumers, and as one type of HVAC systems, the heat pump air conditioning system, which is more energy-efficient compared to the traditional air conditioning system, is being more widely used to save energy. However, in northern China, extreme climatic conditions increase the cooling and heating load of the heat pump air conditioning system and accelerate the aging of the equipment, and the sensor may detect drifted parameters owing to climate change. This non-linear drifted parameter increases the false alarm rate of the fault detection and the need for unnecessary troubleshooting. In order to overcome the impact of the device aging and the drifted parameter, a Kalman filter and SPC (statistical process control) fault detection method are introduced in this paper. In this method, the model parameter and its standard variance can he estimated by Kalman filter based on the gray model and the real-time data of the air conditioning system. Further, by using SPC to construct the dynamic control limits, false alarm rate is reduced. And this paper mainly focuses on the cold machine failure in the component failure and its soft fault detection. This approach has been tested on a simulation model of the "Sino-German Energy Conservation Demonstration Center" building heat pump air-conditioning system in Shenyang, China, and the results show that the Kalman filter and SPC fault detection method is simple and highly efficient with a low false alarm rate, and it can deal with the difficulties caused by the extreme environment and the non-linear influence of the parameters, and what's more, it provides a good foundation for dynamic fault diagnosis and fault prediction analysis.
基金National Natural Science Foundation of China(No.60574081)
文摘In this paper,the fault detection filter(FDF) design problem for networked control systems(NCSs) with both network-induced delay and data dropout is studied.Based on a new NCSs model proposed recently,an observer-based filter is introduced to be the residual generator and formulated as an H∞-optimization problem for systems with two successive delay components.By applying Lyapunov-Krasovskii approach,a new sufficient condition on stability and H∞ performance is derived for systems with two successive delay components in the state.A solution of the optimization problem is then presented in terms of linear matrix inequality(LMI) formulation,dependently of time delay.In order to detect the fault,the residual evaluation problem is also considered.An illustrative design example is employed to demonstrate the validity of the proposed approach.
基金supported by the National Natural Science Foundation of China(6127316261403104)
文摘The problem of the robust fault detection filter design for time-varying delays switched systems is considered in the framework of mixed H-/H∞. Firstly, the weighted H∞ performance index is utilized as the robustness performance, and the H- index is used as the sensitivity performance for obtaining the robust fault detection filter. Then a novel multiple Lyapunov-Krasovskii function is proposed for deriving sufficient existence conditions of the robust fault detection filter based on the average dwell time technique. By introducing slack matrix variable, the coupling between the Lyapunov matrix and system matrix is removed, and the conservatism of results is reduced. Based on the robust fault detection filter, residual is generated and evaluated for detecting faults. In addition, the results of this paper are dependent on time delays,and represented in the form of linear matrix inequalities. Finally,the simulation example verifies the effectiveness of the proposed method.
基金supported by the National Natural Science Foundation of China(6117412161121003+2 种基金61203083)the Research Fund for the Doctoral Program of Higher Education of Chinathe Doctoral Foundation of University of Jinan(XBS1242)
文摘This paper deals with the problem of optimal fault detection filter (FDF) design for a class of discrete-time switched linear systems under arbitrary switching. By using an observer-based FDF as a residual generator, the design of the FDF is formulated into an optimization problem through maximizing the H_/H∞ or H∞/H∞ performance index. With the aid of an operator optimization method, it is shown that a mode-dependent unified optimal solution can be derived by solving a coupled Riccati equation. A numerical example is given to show the effectiveness of the proposed method.
文摘Signals from infrared detector are very weak in SO2 concentration measuring system.In order to improve the sensitivity of detection,combining with filter correlation technology and infrared absorption principle,the weak signal processing circuit is designed according to correlation detection technology.Under laboratory conditions,system performance of SO2 concentration is tested,and the experimental data are analyzed and processed.Then relationship of SO2 concentration and the measuring voltage is provided to prove that the design improves measuring sensitivity of the system.
基金Supported by the National Natural Science Foundation of China (50979017, NSFC60775060) the National High Technology Ship Research Project of China (GJCB09001)
文摘In the normal operation condition, a conventional square-root cubature Kalman filter (SRCKF) gives sufficiently good estimation results. However, if the measurements are not reliable, the SRCKF may give inaccurate results and diverges by time. This study introduces an adaptive SRCKF algorithm with the filter gain correction for the case of measurement malfunctions. By proposing a switching criterion, an optimal filter is selected from the adaptive and conventional SRCKF according to the measurement quality. A subsystem soft fault detection algorithm is built with the filter residual. Utilizing a clear subsystem fault coefficient, the faulty subsystem is isolated as a result of the system reconstruction. In order to improve the performance of the multi-sensor system, a hybrid fusion algorithm is presented based on the adaptive SRCKF. The state and error covariance matrix are also predicted by the priori fusion estimates, and are updated by the predicted and estimated information of subsystems. The proposed algorithms were applied to the vessel dynamic positioning system simulation. They were compared with normal SRCKF and local estimation weighted fusion algorithm. The simulation results show that the presented adaptive SRCKF improves the robustness of subsystem filtering, and the hybrid fusion algorithm has the better performance. The simulation verifies the effectiveness of the proposed algorithms.
基金This work was supported by the National Science Foundation of China (No. 19974063) and the President Foundation of the Institute of Acoustics, Chinese Academy of Sciences.
文摘The ultrasonic testing for the defects of complete disbond in multi-layered structure with lower acoustic impedance beneath a high acoustic impedance overburden is one of the difficult problems in ultrasonic nondestructive testing field. A model of a multi-layered steel-rubber composite plate is depicted. Because the acoustic impedance of the steel differs far from that of the couplant water and the rubber, the energy of the signal reflected from the debonded rubber layers is very weak. More over, the flaw echoes are masked by the strong echoes reverberated in the steel plate. It's nearly impossible to identify the debonding echoes directly. The subband adaptive filtering method is discussed in the paper, where the subband decomposition is performed by mutual wavelet packets decomposition on the criterion of maximizing the cross-correlation between the signals. The simulations on both synthetic and real signals are presented. The echoes from the delaminated flaw at the depth of 5 mm in the rubber from the calculated signal, and echoes from the flaw at the depth of 3 mm from the real signal are extracted successfully.
基金Supported by the Joint Project of National Natural Science Foundation of ChinaCivil Aviation Administration of China(U1333116)
文摘In order to improve the accuracy of free flight conflict detection and reduce the false alarm rate, an improved flight conflict detection algorithm is proposed based on Gauss-Hermite particle filter(GHPF). The algorithm improves the traditional flight conflict detection method in two aspects:(i) New observation data are integrated into system state transition probability, and Gauss-Hermite Filter(GHF) is used for generating the importance density function.(ii) GHPF is used for flight trajectory prediction and flight conflict probability calculation. The experimental results show that the accuracy of conflict detection and tracing with GHPF is better than that with standard particle filter. The detected conflict probability is more precise with GHPF, and GHPF is suitable for early free flight conflict detection.
基金supported by the National Natural Science Foundation of China (Nos. 50977008, 61034005)the National High Technology Research and Development Program of China (No. 2012AA040104)National Basic Research Program of China (No. 2009CB320601)
文摘This paper is concerned with the robust fault detection filter (RFDF) design for a class of linear time- invariant systems (LTISs) with output state time delays. Although existing results in literatures study the RFDF for time- delay systems, few is concerned with the output state time-delay systems. The basic idea of our study is to eliminate the time delays of system and transform it to a delay-free system (i.e., a linear time-invariant system without time delays) by the bicausal change of coordinates approach. Then, we design the RFDF for the delay-free LTIS, which is equivalent to the original system with time delays. We first introduce a class of systems with output state time delays, whose fault can be detected by using the RFDF design approach for delay-free systems. Then, since the RFDF design problem can be formulated as a standard H-infinity-model matching problem, it is solved by using H-infinity-optimization LMI techniques. In the last, the adaptive threshold of fault detection is chosen and an illustrative design example is used to demonstrate the validity of the design approach.
文摘In this paper, an approach for designing robust fault detection filter (RFDF) of networked control systems (NCSs) with unknown inputs is studied. The design aims at implementing the optimal trade-off between robustness of unknown inputs (including the item produced by networked-induced delay) and sensitivity of fault. The key design issue is to introduce an optimal fault detection filter based on NCSs with the control law compensation as the reference residual model of NCSs and to formulate the RFDF design as a model-matching problem. By applying H∞ optimization technique, linear matrix inequality (LMI) approach is given to solve the model-matching problem. The validity of the proposed approach is shown by a numerical example.
基金supported by the National Youth Science Fund Project(61501052)the National Natural Science Foundation of China(61271182)
文摘Echo cancellation plays an important role in current Internet protocol(IP) based voice interactive systems. Voice state detection is an essential part in echo cancellation. It mainly comprises two parts: double talk detection(DTD) and voice activity detection(VAD). DTD is used to detect doubletalk and prevent filter divergence in the presence of near-end speech, and VAD is used to determine the near-end voice activity and output silence indicator when near-end is silent. However, DTD straightforwardly proceeded may mistakenly declare double talk under double silent condition, coefficients update under the far-end silence condition may lead to filter divergence, and current VAD algorithms may misjudge the residual echo from the near end to be far-end voice. Therefore, a voice detection algorithm combining DTD and far-end VAD is proposed. DTD is implemented when VAD declares far-end speech, filtering and coefficients update will be halted when VAD declares far-end silence, and the far-end VAD adopted is multi-feature VAD based on short-time energy and correlation. The new algorithm can improve the accuracy of DTD, prevent filter divergence, and exclude the circumstance that far-end signal only contains residual echo from near end. Actual test results show that the voice state decision of the new algorithm is accurate, and the performance of echo cancellation is improved.
基金National Basic Research Program of China (2010CB731800)
文摘Aiming to the reliable estimates of the ionosphere differential corrections for the satellite navigation system in the presence of the ionosphere anomaly, a fault-tolerance estimating method, which is based on the distributed Kalman filtering, is proposed. The method utilizes the parallel sub-filters for estimating the ionosphere differential corrections. Meanwhile, an infinite norm (IN) method is proposed for the detection of the ionosphere irregularity in the filter processing. Once the anomaly is detected, the sub-filter contaminated by the anomaly measurements will be excluded to ensure the reliability of the estimates. The simulation is conducted to validate the method and the results indicate that the anomaly can be found timely due to the novel fault detection method based on the infinite norm. Because of the parallel sub-filter architecture, the measurements are classified by the spatial distribution so that the ionosphere anomaly can be positioned and excluded more easily. Thus, the method can provide the robust and accurate ionosphere differential corrections.
基金Supported by the National Natural Science Foundation of China(41301519)
文摘Based on the classic filter of progressive triangulated irregular network(TIN) densification, an improved filter is proposed in this paper. In this method, we divide ground points into grids with certain size and select the lowest points in the grids to reconstruct TIN in the process of iteration. Compared with the classic filter of progressive TIN densification(PTD), the improved method can filter out attached objects, avoid the interference of low objects and obtain relatively smooth bare-earth. In addition, this proposed filter can reduce memory requirements and be more efficient in processing huge data volume. The experimental results show that the filtering accuracy and efficiency of this method is higher than that of the PTD method.