期刊文献+
共找到7篇文章
< 1 >
每页显示 20 50 100
A Low Phase Noise, Low Power and Wide Tuning Range VCO with Filtering Technique in ISM Band
1
作者 Masoud Sabaghi Saeid Marjani Abbas Majdabadi 《Circuits and Systems》 2016年第2期51-57,共7页
In this paper, a novel voltage controlled oscillator (VCO) with low phase noise, low power consumption and wide tuning range in the industrial, scientific and medical (ISM) band is proposed for communication systems a... In this paper, a novel voltage controlled oscillator (VCO) with low phase noise, low power consumption and wide tuning range in the industrial, scientific and medical (ISM) band is proposed for communication systems applications. For improving the phase noise, filtering technique is used and VCO is designed with TSMC CMOS 0.18 μm technology and the power supply is 1.5 V. The simulation results with advanced design system (ADS) shows that phase noise in 1 MHz offset frequency from the carrier is -122 dBc/Hz and tuning range is 2 to 2.8 GHz. The power consumption of the core is 2.49 mW. 展开更多
关键词 filtering technique Tuning Range Phase Noise Power Consumption Voltage Controlled Oscillators (VCO)
下载PDF
Application of subband adaptive filtering techniques to ultrasonic detection in multilayers 被引量:2
2
作者 MAO Jie LI Mingxuan(Institute of Acoustics, The Chinese Academy of Sciences Beijing 100080) 《Chinese Journal of Acoustics》 2003年第1期41-49,共9页
The ultrasonic testing for the defects of complete disbond in multi-layered structure with lower acoustic impedance beneath a high acoustic impedance overburden is one of the difficult problems in ultrasonic nondestru... The ultrasonic testing for the defects of complete disbond in multi-layered structure with lower acoustic impedance beneath a high acoustic impedance overburden is one of the difficult problems in ultrasonic nondestructive testing field. A model of a multi-layered steel-rubber composite plate is depicted. Because the acoustic impedance of the steel differs far from that of the couplant water and the rubber, the energy of the signal reflected from the debonded rubber layers is very weak. More over, the flaw echoes are masked by the strong echoes reverberated in the steel plate. It's nearly impossible to identify the debonding echoes directly. The subband adaptive filtering method is discussed in the paper, where the subband decomposition is performed by mutual wavelet packets decomposition on the criterion of maximizing the cross-correlation between the signals. The simulations on both synthetic and real signals are presented. The echoes from the delaminated flaw at the depth of 5 mm in the rubber from the calculated signal, and echoes from the flaw at the depth of 3 mm from the real signal are extracted successfully. 展开更多
关键词 of on IS IT Application of subband adaptive filtering techniques to ultrasonic detection in multilayers in
原文传递
Frequency Structures Vibration Identified by an Adaptative Filtering Techiques Applied on GPS L1 Signal
3
作者 Ana Paula C.Larocca Ricardo E.Schaal +2 位作者 Gabriel do N.Guimaraes Igor Machado da Silveira Paulo César Lima Segantine 《Positioning》 2013年第2期137-143,共7页
This paper is part of a research under enhancement since 2001, in which the main objective is to measure small dynamic displacements by analysis of L1 GPS carrier frequency with 1575.42 MHz—wavelength 19.05 cm, under... This paper is part of a research under enhancement since 2001, in which the main objective is to measure small dynamic displacements by analysis of L1 GPS carrier frequency with 1575.42 MHz—wavelength 19.05 cm, under an adaptive method for collecting data and filtering techniques. This method, named Phase Residual Method (PRM) is based on the frequency domain analysis of the phase residuals resulted from the L1 double difference static data processing of two satellites in almost orthogonal elevation angle. In this work it is proposed to obtain the phase residuals directly from the raw phase observable collected in a short baseline during a limited time span, in lieu of obtaining the residual data file from regular GPS processing programs. In order to improve the ability to detect millimetric displacements, two filtering techniques are introduced. The first one is the autocorrelation that reduces the phase noise with random time behavior. The other one is the running mean to separate low frequency from the high frequency phase sources. Two trials are presented to verify the proposed method and filtering techniques applied. One simulates a 2.5 millimeter vertical GPS antenna displacement and the second using the data collected during a bridge dynamic load test. The results show a good consistency to detect millimetric oscillations from L1 frequency and filtering techniques. 展开更多
关键词 L1 GPS Frequency Processing filtering techniques Millimetric Displacements Single Frequency Receiver
下载PDF
SEPARATION OF OVERLAPPING INCISIONS OF A.C.OSCILLOPOLAROGRAM USING KALMAN'S FILTER TECHNIQUE
4
作者 Si Dan DU Shu Ping BI Zhong WANG Hong GAO (H.Kao) Chemistry Department,Nanjing University,Nanjing,210008,P.R.China 《Chinese Chemical Letters》 SCIE CAS CSCD 1991年第2期151-152,共2页
Kalman's Filter Technique for the separation of overlapping incisions of an a.c.oscillopolarogram is presented,the experimental verifications were carried out in various systems with the ions of Pb^(2+),Tl^+,In^(3... Kalman's Filter Technique for the separation of overlapping incisions of an a.c.oscillopolarogram is presented,the experimental verifications were carried out in various systems with the ions of Pb^(2+),Tl^+,In^(3+)and Cd^(2+).The results showed that the concentration of the depolarizer can be determined directly and easily with this technique in the presence of interference elements. 展开更多
关键词 In this SEPARATION OF OVERLAPPING INCISIONS OF A.C.OSCILLOPOLAROGRAM USING KALMAN’S FILTER technique
下载PDF
Tunable wavelength filters using polymer long-period waveguide gratings based on metal-cladding directly defined technique
5
作者 王继厚 陈长鸣 +5 位作者 郑洋 王希斌 衣云骥 孙小强 王菲 张大明 《Chinese Physics B》 SCIE EI CAS CSCD 2017年第2期268-273,共6页
In this work, long-period waveguide grating-based tunable wavelength filters using organic–inorganic grafting poly(methyl methacrylate)(PMMA) materials are designed and fabricated by metal-cladding directly defin... In this work, long-period waveguide grating-based tunable wavelength filters using organic–inorganic grafting poly(methyl methacrylate)(PMMA) materials are designed and fabricated by metal-cladding directly defined technique.The thermal stabilities and optical properties of the organic–inorganic grafting PMMA core materials are analyzed. Structures and performance parameters of the waveguide gratings and self-electrode heaters are designed and simulated. The contrast of the filter is about 15 d B and the resonant wavelength can be tuned by different electric powers applied to the metal-cladding self-electrode heaters. The temperature sensitivity is 3.5 nm/℃ and the switching time is about 1 ms. The technique is very suitable for realizing the optoelectronic integrated wavelength-division-multiplexing systems. 展开更多
关键词 organic–inorganic grafting materials polymer optical waveguide long-period grating filter metalcladding defined technique
下载PDF
Distance-Measuring Technology Using LD for Auto Anti-Collision 被引量:2
6
作者 ZhangXin-bao LuHong LiZhu 《Wuhan University Journal of Natural Sciences》 EI CAS 2004年第1期83-88,共6页
Auto anti-collision technology is one of the main research subjects of automobiles’ safety technology. Aiming at the key technology of Auto anti-collision, measuring the distance from obstacles, based on the theory o... Auto anti-collision technology is one of the main research subjects of automobiles’ safety technology. Aiming at the key technology of Auto anti-collision, measuring the distance from obstacles, based on the theory of phase laser distance ranging, Laser Diode (LD) distance-measuring system for auto anti-collision has been developed to solve the problem of on-line measuring distance technology in middle to long distance utilizing the good characteristics of LD when modulating its optical intensity and adopting typical kinds of filter techniques in this paper. By theoretical analysis, adopting typical kinds of filter techniques can reduce the interference of strong light, so distance-measuring range can be 0.5–100 m in daytime or 1–200 m at night. And more, from theoretical analysis and experiment result, it can guarantee the high measuring resolution which can be less than 24.5 mm, utilizing the method of two Laser Diode optical intensity modulating wavelength and complimenting precise calibration and revision. The idea of LD distance-measuring technology is novel and feasible and this technology can be applied in Auto anti-collision. Key words laser diode - phase laser distance ranging - filter techniques - auto anti-collision CLC number TH 161 Foundation item: Supported by the National Natural Science Foundation of China (59675080, 59805006) and Wuhan Chenguang Foundation (20025001001)Biography: Zhang Xin-bao (1965-), male, Associate professor, research direction: precise mechanism and instrument. 展开更多
关键词 laser diode phase laser distance ranging filter techniques auto anti-collision
下载PDF
Rapid discovery and identification of 68 compounds in the active fraction from Xiao-Xu-Ming decoction(XXMD) by HPLC-HRMS and MTSF technique 被引量:8
7
作者 Cai-Hong Wang Cai-Sheng Wu +1 位作者 Hai-Lin Qin Jin-Lan Zhang 《Chinese Chemical Letters》 SCIE CAS CSCD 2014年第12期1648-1652,共5页
Xiao-Xu-Ming decoction(XXMD) was a traditional Chinese prescription and first recorded in "Bei Ji Qian Jin Yao Fang".It has been widely used to treat theoplegia and the sequel of theoplegia in China.In the present... Xiao-Xu-Ming decoction(XXMD) was a traditional Chinese prescription and first recorded in "Bei Ji Qian Jin Yao Fang".It has been widely used to treat theoplegia and the sequel of theoplegia in China.In the present work,high-performance liquid chromatography coupled with high resolution mass spectrometry(HPLC-HRMS) combined with the mass spectral tree similarity filter technique(MTSF)was used to rapidly discover and identify the compounds of the active fraction of XXMD.A total of 3362 compounds were automatically detected by HPLC-HRMS,and final 68 compounds were identified in the active fraction of XXMD.including 14 templated compounds(reference compounds),50 related compounds fished by MTSF technique,and 4 unrelated compounds identified by manual method.This study successfully applied MTSF technology for the first time to discover and identify the components of Chinese prescription.The results demonstrated that MTSF technique should be useful to the discovery and identification of compounds in Chinese prescription.This study also proved that MTSF can be applied to the targeted phytochemical separation. 展开更多
关键词 Xiao-Xu-Ming decoction High-performance liquid chromatography with high resolution mass spectrometry Mass spectral trees similarity filter technique
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部