To find a neural network model suitable to identify the concentration of mixed pernicious gases in pig house, the quantitative detection model of pernicious gases in pig house was set up based on BP ( Back propagatio...To find a neural network model suitable to identify the concentration of mixed pernicious gases in pig house, the quantitative detection model of pernicious gases in pig house was set up based on BP ( Back propagation) neural network. The BP neural network was trained separately by the three functions, trainbr, traingdm and trainlm, in order to identify the concentration of mixed pernicious gases composed of ammonia gas and hepatic gas. The neural network toolbox in MATLAB software was used to simulate the detection. The results showed that the neural network trained by trainbr function has high average identification accuracy and faster detection speed, and it is also insensitive to noise; therefore, it is suitable to identify the concentration of pemidous gases in pig house. These data provide a reference for intelligent monitoring of pemicious gases in pigsty.展开更多
Pesticide residue detection is an important work to ensure the quality safety of agricultural products.In the process of agricultural production,in order to prevent and control agricultural diseases and pests,a certai...Pesticide residue detection is an important work to ensure the quality safety of agricultural products.In the process of agricultural production,in order to prevent and control agricultural diseases and pests,a certain amount of pesticides need to be used.However,if pesticides are used excessively,there will be certain pesticide residues in crops and related products.Therefore,it is necessary to do a good job in pesticide residue detection.The gas chromatography-mass spectrometry(GC-MS)and liquid chromatography-mass spectrometry(LC-MS)detection methods have good results and can effectively detect pesticide residues in related products.This paper reviewed and analyzed the application of GC-MS and LC-MS in pesticide residue detection,and proposed optimization measures based on practical experience,hoping to provide reference for relevant scholars.展开更多
Integrated cavity output spectroscopy(ICOS) is an effective technique in trace gase detection.The strong absorption due to the long optical path of this method makes it challenging in the application scenes that have ...Integrated cavity output spectroscopy(ICOS) is an effective technique in trace gase detection.The strong absorption due to the long optical path of this method makes it challenging in the application scenes that have large gas concentration fluctuation,especially when the gas concentration is high.In this paper,we demonstrate an extension of the dynamic range of ICOS by using a detuned laser combined with an off-axis integrating cavity.With this,we improve the upper limit of the dynamic detection range from 0.1%(1000 ppm) to 20% of the gas concentration.This method provides a way of using ICOS in the applications with unpredictable gas concentrations such as gas leak detection,ocean acidification,carbon sequestration,etc.展开更多
Polythiophene/WO3(PTP/WO3)organic-inorganic hybrids were synthesized by an in situ chemical oxidative polymerization method,and char- acterized by X-ray diffraction(XRD),transmission electron microscopy(TEM)and ...Polythiophene/WO3(PTP/WO3)organic-inorganic hybrids were synthesized by an in situ chemical oxidative polymerization method,and char- acterized by X-ray diffraction(XRD),transmission electron microscopy(TEM)and thermo-gravimetric analysis(TGA).The Polythiophene/ WO3 hybrids have higher thermal stability than pure polythiophene,which is beneficial to potential application as chemical sensors.Gas sensing measurements demonstrate that the gas sensor based on the Polythiophene/WO3 hybrids has high response and good selectivity for de- tecting NO2 of ppm level at low temperature.Both the operating temperature and PTP contents have an influence on the response of PTP/WO3 hybrids to NO2.The 10 wt%PTP/WO3 hybrid showed the highest response at low operating temperature of 70-C.It is expected that the PTP/WO3 hybrids can be potentially used as gas sensor material for detecting the low concentration of NO2 at low temperature.展开更多
This paper is aimed at the actual conditions of disaster caused by gas in small and medium-sized coal mines. A new gas concentration monitoring system for coal mines is developed on the basis of gas-sensing detection ...This paper is aimed at the actual conditions of disaster caused by gas in small and medium-sized coal mines. A new gas concentration monitoring system for coal mines is developed on the basis of gas-sensing detection and single-chip control. The monitoring system uses the tin oxide as the main material of N-type semiconductor gas sensors, be- cause it has good sensitive characteristics for the flammable and explosive gas ( such as methane, carbon monoxide). The QM-N5-semiconductor gas sensor is adopted to detect the output values of the resistance under the different gas con- centrations. The system, designedly, takes the AT89C51 digital chip as the core of the circuit processing hardware structure to analyze and judge the input values of the resistance, and then achieve the control and alarm for going beyond the limit of gas concentration. The gas concentration monitoring system has man), advantages including simple in struc- ture, fast response time, stable performance and low cost. Thus, it can be widely used to monitor gas concentration and provide early wamings in small and medium-sized coal mines.展开更多
Micro-light-emitting diodes(μLEDs)have gained significant interest as an activation source for gas sensors owing to their advantages,including room temperature operation and low power consumption.However,despite thes...Micro-light-emitting diodes(μLEDs)have gained significant interest as an activation source for gas sensors owing to their advantages,including room temperature operation and low power consumption.However,despite these benefits,challenges still exist such as a limited range of detectable gases and slow response.In this study,we present a blueμLED-integrated light-activated gas sensor array based on SnO_(2)nanoparticles(NPs)that exhibit excellent sensitivity,tunable selectivity,and rapid detection with micro-watt level power consumption.The optimal power forμLED is observed at the highest gas response,supported by finite-difference time-domain simulation.Additionally,we first report the visible light-activated selective detection of reducing gases using noble metal-decorated SnO_(2)NPs.The noble metals induce catalytic interaction with reducing gases,clearly distinguishing NH3,H2,and C2H5OH.Real-time gas monitoring based on a fully hardwareimplemented light-activated sensing array was demonstrated,opening up new avenues for advancements in light-activated electronic nose technologies.展开更多
Metal-organic frameworks(MOFs)have been extensively used for gas sorption,storage and separation owing to ultrahigh porosity,exceptional thermal stability,and wide structural diversity.However,when it comes to ultra-l...Metal-organic frameworks(MOFs)have been extensively used for gas sorption,storage and separation owing to ultrahigh porosity,exceptional thermal stability,and wide structural diversity.However,when it comes to ultra-low concentration gas detection,technical bottlenecks of MOFs appear due to the poor adsorption capacity at ppm-/ppblevel concentration and the limited sensitivity for signal transduction.Here,we present hybrid MOF-polymer physi-chemisorption mechanisms integrated with infrared(IR)nanoantennas for highly selective and ultrasensitive CO_(2) detection.To improve the adsorption capacity for trace amounts of gas molecules,MOFs are decorated with amino groups to introduce the chemisorption while maintaining the structural integrity for physisorption.Additionally,leveraging all major optimization methods,a multi-hotspot strategy is proposed to improve the sensitivity of nanoantennas by enhancing the near field and engineering the radiative and absorptive loss.As a benefit,we demonstrate the competitive advantages of our strategy against the state-of-the-art miniaturized IR CO_(2) sensors,including low detection limit,high sensitivity(0.18%/ppm),excellent reversibility(variation within 2%),and high selectivity(against C_(2)H_(5)OH,CH_(3)OH,N_(2)).This work provides valuable insights into the integration of advanced porous materials and nanophotonic devices,which can be further adopted in ultra-low concentration gas monitoring in industry and environmental applications.展开更多
Sulfur dioxide has been found to decrease the chemiluminescence of luminol-iodine system.A new determination method for sulfur dioxide in atmosphere is developed by applying this reaction to a flow injection gas diffu...Sulfur dioxide has been found to decrease the chemiluminescence of luminol-iodine system.A new determination method for sulfur dioxide in atmosphere is developed by applying this reaction to a flow injection gas diffusion separation system.This permits the determination of sulfur dioxide selectively and rapidly.展开更多
When a cold rolled strip is being treated in a continuous annealing furnace which is full of protective gas, the gas tightness of the furnace body, the connected facilities and the gas channels become an important ind...When a cold rolled strip is being treated in a continuous annealing furnace which is full of protective gas, the gas tightness of the furnace body, the connected facilities and the gas channels become an important indicator that directly affects the product's surface quality and shows the technical level of the design, the manufacture and the installation. By considering the problems of the gas tightness of a vertical annealing furnace in the installation and maintenance, this thesis evaluates the gas tightness indicator and gas tightness related level of the furnace body and the circulation duct, while studying and analyzing the technologies of negative-pressure leak detection and sealing.展开更多
The feasibility of gas kick early detection outside the riser was analyzed based on gas-liquid multiphase flow theory.Then an experimental platform for gas kick early detection based on Doppler ultrasonic wave was est...The feasibility of gas kick early detection outside the riser was analyzed based on gas-liquid multiphase flow theory.Then an experimental platform for gas kick early detection based on Doppler ultrasonic wave was established and the propagation experiments in two-phase flow of gas-water(sucrose solutions)were conducted.The time and frequency domains of the Doppler ultrasonic wave signals during the experiments were analyzed.The results show that:(1)No matter the pump was on or off,the detected average Doppler ultrasonic signal voltage increased first and then decreased with the increase of the gas void fraction,and had a quadratic function relation with gas void fraction,so the average voltage change of the monitored signals can be used to deduce the approximate gas void fraction.The Doppler ultrasonic wave signal voltage was significantly reduced in magnitude and variation in the solution with higher viscosity,and the viscosity has stronger impact on the magnitude of signal than density.(2)When the pump was stopped,the Doppler shift increased with the increase of gas void fraction,and the two showed a nearly linear relation,so the detected amount of Doppler shift can reflect the variation of gas void fraction quantitatively.When the pump was on,the sound energy produced by frequency converter had a more significant impact on amplitude spectrum than gas void fraction,so it is impossible to determine whether gas kick occurs by frequency domain signal analysis.(3)This method is a non-contact measurement,with no contact with the drilling fluid and no disruption to the drilling operation.It can quantitatively characterize the gas void fraction according to the change of Doppler ultrasonic signal,enabling earlier detection of gas kick.展开更多
Wavelength sweep technique (WST) is introduced into intra-cavity fiber laser (ICFL) for low concentration gas detection. The limitation induced by noise can be eliminated using this method, and the performance of ...Wavelength sweep technique (WST) is introduced into intra-cavity fiber laser (ICFL) for low concentration gas detection. The limitation induced by noise can be eliminated using this method, and the performance of the system is improved. The sensitivity of the system is reduced to less than 300 ppm. With WST, sweeping characteristic of the ICFL can be described according to known gas absorption spectra.展开更多
In heterogeneous natural gas reservoirs, gas is generally present as small patchlike pockets embedded in the water-saturated host matrix. This type of heterogeneity, also called "patchy saturation", causes s...In heterogeneous natural gas reservoirs, gas is generally present as small patchlike pockets embedded in the water-saturated host matrix. This type of heterogeneity, also called "patchy saturation", causes significant seismic velocity dispersion and attenuation. To establish the relation between seismic response and type of fluids, we designed a rock physics model for carbonates. First, we performed CT scanning and analysis of the fluid distribution in the partially saturated rocks. Then, we predicted the quantitative relation between the wave response at different frequency ranges and the basic lithological properties and pore fluids. A rock physics template was constructed based on thin section analysis of pore structures and seismic inversion. This approach was applied to the limestone gas reservoirs of the right bank block of the Amu Darya River. Based on poststack wave impedance and prestack elastic parameter inversions, the seismic data were used to estimate rock porosity and gas saturation. The model results were in good agreement with the production regime of the wells.展开更多
Owing to the ppb-level detection standard toward the toxic and harmful gas,the detection of trace gases has become an important subject in the field of indoor environment management.However,the traditional resistive g...Owing to the ppb-level detection standard toward the toxic and harmful gas,the detection of trace gases has become an important subject in the field of indoor environment management.However,the traditional resistive gas sensors hardly meet the requirement due to the weak signal generated by trace gas molecules that are difficult to capture.Herein,a visible-light-assisted Pd/TiO_(2)gas sensor is proposed to endow the effective detection of trace formaldehyde(HCHO)gas without heating temperature.Benefiting from the enhanced photocatalytic properties of TiO_(2)by Pd decoration,the visible-light-assisted Pd/TiO_(2)gas sensor can detect the HCHO gas as low as80×10^(–9)at room temperature.The successful preparation of nanoscale TiO_(2)sensing layer is facilitated by the ultrathin carbon nanotube interdigital electrode in the gas sensor,which avoids the discontinuity of the sensing layer caused by the excessive thickness of the traditional metal electrode.In addition,the whole preparation process of the Pd/TiO_(2)gas sensor with carbon nanotube electrodes is compatible with mainstream CMOS fabrication technology,which is expected to realize the batch fabrication and micro-integrated application of gas sensors.It is expected that our work can provide a new strategy for the batch preparation of high-performance trace HCHO gas sensors and their future applications in portable electronic devices such as smartphones.展开更多
Effective methods are urgently required to optimize Raman spectroscopy technology to ameliorate its low detection sensitivity.Here,we superposed two near-concentric cavities to develop a dual near-concentric cavities ...Effective methods are urgently required to optimize Raman spectroscopy technology to ameliorate its low detection sensitivity.Here,we superposed two near-concentric cavities to develop a dual near-concentric cavities group(DNCCG)to assess its effect on gas Raman signal intensity,signal-to-noise ratio(SNR),and limit of detection(LOD).The results showed that DNCCG generally had higher CO_(2) Raman signal intensity than the sum of two near-concentric cavities.Meanwhile,the noise intensity of DNCCG was not enhanced by the superposition of near-concentric cavities.Accordingly,DNCCG increased the SNR.The LOD for CO_(2) was 24.6 parts per million.DNCCG could be an effective method to improve the detection capability of trace gases and broaden the dynamic detection range,which might aid the future development of innovative technology for multicomponent gas detection.展开更多
The identification of indoor harmful gases is imperative due to their significant threats to human health and safety.To achieve accurate identification,an effective strategy of constructing a sensor array combined wit...The identification of indoor harmful gases is imperative due to their significant threats to human health and safety.To achieve accurate identification,an effective strategy of constructing a sensor array combined with the pattern recognition algorithm is employed.Carbon-based thin-film transistors are selected as the sensor array unit,with semiconductor carbon nanotubes(CNTs)within the TFT channels modified with different metals(Au,Cu and Ti)for selective responses to NH_(3),H_(2)S and HCHO,respectively.For accurate gas species identification,an identification mode that combines linear discriminant analysis algorithms and logistic regression classifier is developed.The test results demonstrate that by preprocessing the sensor array’s sensing data with the LDA algorithm and subsequently employing the LR classifier for identification,a 100%recognition rate can be achieved for three target gases(NH3,H2S and HCHO).This work provides significant guidance for future applications of chip-level gas sensors in the realms of the Internet of Things and Artificial Intelligence.展开更多
High-precision methane gas detection is of great importance in industrial safety, energy production and environmental protection, etc. However, in the existing measurement techniques, the methane gas concentration inf...High-precision methane gas detection is of great importance in industrial safety, energy production and environmental protection, etc. However, in the existing measurement techniques, the methane gas concentration information is susceptible to noise, which leads to its useful signal being drowned by noise. A fusion algorithm of variational modal decomposition(VMD) and improved wavelet threshold filtering is proposed, which is used in combination with tunable diode laser absorption spectroscopy(TDLAS) to implement a non-contact, high-resolution methane gas concentration detection. The fusion algorithm can perform noise reduction and further segmentation of the methane gas detection signal. And the simulation and experiment verify the effectiveness of the fusion algorithm, and the experimental results show that for the detection of air containing 10 ppm, 30 ppm, 60 ppm, 80 ppm, and 99 ppm methane, the errors are 12.75%, 8.18%, 3.37%, 2.46%, and 1.78%, respectively.展开更多
In the petroleum industry,detection of multi-phase fluid flow is very important in both surface and down-hole measurements.Accurate measurement of high rate of water or gas multi-phase flow has always been an academic...In the petroleum industry,detection of multi-phase fluid flow is very important in both surface and down-hole measurements.Accurate measurement of high rate of water or gas multi-phase flow has always been an academic and industrial focus.NMR is an efficient and accurate technique for the detection of fluids;it is widely used in the determination of fluid compositions and properties.This paper is aimed to quantitatively detect multi-phase flow in oil and gas wells and pipelines and to propose an innovative method for online nuclear magnetic resonance(NMR)detection.The online NMR data acquisition,processing and interpretation methods are proposed to fill the blank of traditional methods.A full-bore straight tube design without pressure drop,a Halbach magnet structure design with zero magnetic leakage outside the probe,a separate antenna structure design without flowing effects on NMR measurement and automatic control technology will achieve unattended operation.Through the innovation of this work,the application of NMR for the real-time and quantitative detection of multi-phase flow in oil and gas wells and pipelines can be implemented.展开更多
Higher-precision determinations of hydrate reservoirs, hydrate saturation levels and storage estimations are important for guaranteeing the ability to continuously research, develop and utilize natural gas hydrate res...Higher-precision determinations of hydrate reservoirs, hydrate saturation levels and storage estimations are important for guaranteeing the ability to continuously research, develop and utilize natural gas hydrate resources in China. With seismic stereoscopic detection technology, which fully combines the advantages of different seismic detection models, hydrate formation layers can be observed with multiangle, wide-azimuth, wide-band data with a high precision. This technique provides more reliable data for analyzing the distribution characteristics of gas hydrate reservoirs, establishing velocity models, and studying the hydrate-sensitive properties of petrophysical parameters;these data are of great significance for the exploration and development of natural gas hydrate resources. Based on a velocity model obtained from the analysis of horizontal streamer velocity data in the hydrate-bearing area of the Shenhu Sea, this paper uses three VCs(longitudinal spacing of 25 m) and four OBSs(transverse spacing of 200 m) to jointly detect seismic datasets consisting of wave points based on an inversion of traveltime imaging sections. Accordingly, by comparing the differences between the seismic phases in the original data and the forward-modeled seismic phases, multiangle coverage constraint corrections are applied to the initial velocity model, and the initial model is further optimized, thereby improving the imaging quality of the streamer data. Petrophysical elastic parameters are the physical parameters that are most directly and closely related to rock formations and reservoir physical properties. Based on the optimized velocity model, the rock elastic hydrate-sensitive parameters of the hydrate reservoirs in the study area are inverted, and the sensitivities of the petrophysical parameters to natural gas hydrates are investigated. According to an analysis of the inversion results obtained from these sensitive parameters, λρ, Vp and λμ are simultaneously controlled by the bulk modulus and shear modulus, while Vs and μρ are controlled only by the shear modulus, and the latter two parameters are less sensitive to hydrate-bearing layers. The bulk modulus is speculated to be more sensitive than the shear modulus to hydrates. In other words, estimating the specific gravity of the shear modulus among the combined parameters can affect the results from the combined elastic parameters regarding hydrate reservoirs.展开更多
Hazardous gas detection systems play an important role in preventing catastrophic gas-related accidents in process industries. Even though effective detection technology currently exists for hazardous gas releases and...Hazardous gas detection systems play an important role in preventing catastrophic gas-related accidents in process industries. Even though effective detection technology currently exists for hazardous gas releases and a majority of process installations have a large number of sensitive detectors in place, the actual operating performance of gas detection systems still does not meet the expected requirements. In this paper, a riskbased methodology is proposed to optimize the placement of hazardous gas detectors. The methodology includes three main steps, namely, the establishment of representative leak scenarios, computational fluid dynamics(CFD)-based gas dispersion modeling, and the establishment of an optimized solution. Based on the combination of gas leak probability and joint distribution probability of wind velocity and wind direction, a quantitative filtering approach is presented to select representative leak scenarios from all potential scenarios. The commercial code ANSYS-FLUENT is used to estimate the consequence of hazardous gas dispersions under various leak and environmental conditions. A stochastic mixed-integer linear programming formulation with the objective of minimizing the total leak risk across all representative leak scenarios is proposed, and the greedy dropping heuristic algorithm(GDHA) is used to solve the optimization model. Finally, a practical application of the methodology is performed to validate its effectiveness for the optimal design of a gas detector system in a high-sulfur natural gas purification plant in Chongqing, China. The results show that an appropriate number of gas detectors with optimal cost-effectiveness can be obtained, and the total leak risk across all potential scenarios can be substantially reduced. This methodology provides an effective approach to guide the optimal placement of pointtype gas detection systems involved with either single or mixed gas releases.展开更多
For solving the difficult problem of leakage detection in city gas pipelines, a method using acoustic technique based on instantaneous energy (IE) distribution and correlation analysis was proposed. Firstly, the basic...For solving the difficult problem of leakage detection in city gas pipelines, a method using acoustic technique based on instantaneous energy (IE) distribution and correlation analysis was proposed. Firstly, the basic theory of leakage detection and location was introduced. Then the physical relationship between instantaneous energy and structural state variation of a system was analyzed theoretically. With HILBERT-HUANG transformation (HHT), the instantaneous energy distribution feature of an unstable acoustic signal was obtained. According to the relative contribution method of the instantaneous energy, the noise in signal was eliminated effectively. Furthermore, in order to judge the leakage, the typical characteristic of the instantaneous energy of signal in the input and output end was discussed using correlative analysis. A number of experiments were carried out to classify the leakage from normal operations, and the results show that the leakages are successfully detected and the average recognition rate reaches 93.3% among three group samples. It is shown that the method using acoustic technique with IED and correlative analysis is effective and it may be referred in other pipelines.展开更多
文摘To find a neural network model suitable to identify the concentration of mixed pernicious gases in pig house, the quantitative detection model of pernicious gases in pig house was set up based on BP ( Back propagation) neural network. The BP neural network was trained separately by the three functions, trainbr, traingdm and trainlm, in order to identify the concentration of mixed pernicious gases composed of ammonia gas and hepatic gas. The neural network toolbox in MATLAB software was used to simulate the detection. The results showed that the neural network trained by trainbr function has high average identification accuracy and faster detection speed, and it is also insensitive to noise; therefore, it is suitable to identify the concentration of pemidous gases in pig house. These data provide a reference for intelligent monitoring of pemicious gases in pigsty.
基金Supported by The Fourth Batch of High-end Talent Project in Hebei ProvinceTangshan Science and Technology Entrepreneurship and Innovation Leading Talent Project(21130243A)+1 种基金Special Project of the Central Government in Guidance of Local Science and Technology Development(226Z5504G)Tangshan Talent Project(A202202005).
文摘Pesticide residue detection is an important work to ensure the quality safety of agricultural products.In the process of agricultural production,in order to prevent and control agricultural diseases and pests,a certain amount of pesticides need to be used.However,if pesticides are used excessively,there will be certain pesticide residues in crops and related products.Therefore,it is necessary to do a good job in pesticide residue detection.The gas chromatography-mass spectrometry(GC-MS)and liquid chromatography-mass spectrometry(LC-MS)detection methods have good results and can effectively detect pesticide residues in related products.This paper reviewed and analyzed the application of GC-MS and LC-MS in pesticide residue detection,and proposed optimization measures based on practical experience,hoping to provide reference for relevant scholars.
基金Project supported by the National Key Research and Development Program of China(Grant No.2017YFC0209700)the National Natural Science Foundation of China(Grant No.41730103)。
文摘Integrated cavity output spectroscopy(ICOS) is an effective technique in trace gase detection.The strong absorption due to the long optical path of this method makes it challenging in the application scenes that have large gas concentration fluctuation,especially when the gas concentration is high.In this paper,we demonstrate an extension of the dynamic range of ICOS by using a detuned laser combined with an off-axis integrating cavity.With this,we improve the upper limit of the dynamic detection range from 0.1%(1000 ppm) to 20% of the gas concentration.This method provides a way of using ICOS in the applications with unpredictable gas concentrations such as gas leak detection,ocean acidification,carbon sequestration,etc.
基金financially supported by the National Natural Science Foundation of China(No.20871071)the Science and Technology Commission Foundation of Tianjin(No.09JCYBJC03600 and 10JCYBJC03900)
文摘Polythiophene/WO3(PTP/WO3)organic-inorganic hybrids were synthesized by an in situ chemical oxidative polymerization method,and char- acterized by X-ray diffraction(XRD),transmission electron microscopy(TEM)and thermo-gravimetric analysis(TGA).The Polythiophene/ WO3 hybrids have higher thermal stability than pure polythiophene,which is beneficial to potential application as chemical sensors.Gas sensing measurements demonstrate that the gas sensor based on the Polythiophene/WO3 hybrids has high response and good selectivity for de- tecting NO2 of ppm level at low temperature.Both the operating temperature and PTP contents have an influence on the response of PTP/WO3 hybrids to NO2.The 10 wt%PTP/WO3 hybrid showed the highest response at low operating temperature of 70-C.It is expected that the PTP/WO3 hybrids can be potentially used as gas sensor material for detecting the low concentration of NO2 at low temperature.
基金supported by the program of Science and Technology Innovative Research Team in Higher Educational Institutions of Hunan Provincethe Hunan Province and Xiangtan City Natural Science Joint Foundation(No.09JJ8005)+1 种基金the Industrial Cultivation Program of Scientific and Technological Achievements in Higher Educational Institutions of Hunan Province(No.10CY008)the Technologies R & D of Hunan Province (No.2010CK3031)
文摘This paper is aimed at the actual conditions of disaster caused by gas in small and medium-sized coal mines. A new gas concentration monitoring system for coal mines is developed on the basis of gas-sensing detection and single-chip control. The monitoring system uses the tin oxide as the main material of N-type semiconductor gas sensors, be- cause it has good sensitive characteristics for the flammable and explosive gas ( such as methane, carbon monoxide). The QM-N5-semiconductor gas sensor is adopted to detect the output values of the resistance under the different gas con- centrations. The system, designedly, takes the AT89C51 digital chip as the core of the circuit processing hardware structure to analyze and judge the input values of the resistance, and then achieve the control and alarm for going beyond the limit of gas concentration. The gas concentration monitoring system has man), advantages including simple in struc- ture, fast response time, stable performance and low cost. Thus, it can be widely used to monitor gas concentration and provide early wamings in small and medium-sized coal mines.
基金supported by the Nano&Material Technology Development Program through the National Research Foundation of Korea(NRF)funded by Ministry of Science and ICT(RS-2024-00405016)supported by“Cooperative Research Program for Agriculture Science and Technology Development(Project No.PJ01706703)”Rural Development Administration,Republic of Korea.The Inter-University Semiconductor Research Center and Institute of Engineering Research at Seoul National University provided research facilities for this work.
文摘Micro-light-emitting diodes(μLEDs)have gained significant interest as an activation source for gas sensors owing to their advantages,including room temperature operation and low power consumption.However,despite these benefits,challenges still exist such as a limited range of detectable gases and slow response.In this study,we present a blueμLED-integrated light-activated gas sensor array based on SnO_(2)nanoparticles(NPs)that exhibit excellent sensitivity,tunable selectivity,and rapid detection with micro-watt level power consumption.The optimal power forμLED is observed at the highest gas response,supported by finite-difference time-domain simulation.Additionally,we first report the visible light-activated selective detection of reducing gases using noble metal-decorated SnO_(2)NPs.The noble metals induce catalytic interaction with reducing gases,clearly distinguishing NH3,H2,and C2H5OH.Real-time gas monitoring based on a fully hardwareimplemented light-activated sensing array was demonstrated,opening up new avenues for advancements in light-activated electronic nose technologies.
基金This work is supported by the RIE Advanced Manufacturing and Engineering(AME)Programmatic Grant Project(Grant A18A5b0056,WBS:A-0005117-02-00)the Advanced Research and Technology Innovation Centre(ARTIC)Project(WBS:A-0005947-20-00)the Ministry of Education(MOE)of Singapore Tier 1 Project(WBS:A-0005138-01-00).
文摘Metal-organic frameworks(MOFs)have been extensively used for gas sorption,storage and separation owing to ultrahigh porosity,exceptional thermal stability,and wide structural diversity.However,when it comes to ultra-low concentration gas detection,technical bottlenecks of MOFs appear due to the poor adsorption capacity at ppm-/ppblevel concentration and the limited sensitivity for signal transduction.Here,we present hybrid MOF-polymer physi-chemisorption mechanisms integrated with infrared(IR)nanoantennas for highly selective and ultrasensitive CO_(2) detection.To improve the adsorption capacity for trace amounts of gas molecules,MOFs are decorated with amino groups to introduce the chemisorption while maintaining the structural integrity for physisorption.Additionally,leveraging all major optimization methods,a multi-hotspot strategy is proposed to improve the sensitivity of nanoantennas by enhancing the near field and engineering the radiative and absorptive loss.As a benefit,we demonstrate the competitive advantages of our strategy against the state-of-the-art miniaturized IR CO_(2) sensors,including low detection limit,high sensitivity(0.18%/ppm),excellent reversibility(variation within 2%),and high selectivity(against C_(2)H_(5)OH,CH_(3)OH,N_(2)).This work provides valuable insights into the integration of advanced porous materials and nanophotonic devices,which can be further adopted in ultra-low concentration gas monitoring in industry and environmental applications.
文摘Sulfur dioxide has been found to decrease the chemiluminescence of luminol-iodine system.A new determination method for sulfur dioxide in atmosphere is developed by applying this reaction to a flow injection gas diffusion separation system.This permits the determination of sulfur dioxide selectively and rapidly.
文摘When a cold rolled strip is being treated in a continuous annealing furnace which is full of protective gas, the gas tightness of the furnace body, the connected facilities and the gas channels become an important indicator that directly affects the product's surface quality and shows the technical level of the design, the manufacture and the installation. By considering the problems of the gas tightness of a vertical annealing furnace in the installation and maintenance, this thesis evaluates the gas tightness indicator and gas tightness related level of the furnace body and the circulation duct, while studying and analyzing the technologies of negative-pressure leak detection and sealing.
基金Supported by Natural Science Foundation of China(51991363)National Program on Key Basic Research Project(973 Program)(2015CB251200)Changjiang Scholars and Innovative Research Team Project(IRT_14R58)
文摘The feasibility of gas kick early detection outside the riser was analyzed based on gas-liquid multiphase flow theory.Then an experimental platform for gas kick early detection based on Doppler ultrasonic wave was established and the propagation experiments in two-phase flow of gas-water(sucrose solutions)were conducted.The time and frequency domains of the Doppler ultrasonic wave signals during the experiments were analyzed.The results show that:(1)No matter the pump was on or off,the detected average Doppler ultrasonic signal voltage increased first and then decreased with the increase of the gas void fraction,and had a quadratic function relation with gas void fraction,so the average voltage change of the monitored signals can be used to deduce the approximate gas void fraction.The Doppler ultrasonic wave signal voltage was significantly reduced in magnitude and variation in the solution with higher viscosity,and the viscosity has stronger impact on the magnitude of signal than density.(2)When the pump was stopped,the Doppler shift increased with the increase of gas void fraction,and the two showed a nearly linear relation,so the detected amount of Doppler shift can reflect the variation of gas void fraction quantitatively.When the pump was on,the sound energy produced by frequency converter had a more significant impact on amplitude spectrum than gas void fraction,so it is impossible to determine whether gas kick occurs by frequency domain signal analysis.(3)This method is a non-contact measurement,with no contact with the drilling fluid and no disruption to the drilling operation.It can quantitatively characterize the gas void fraction according to the change of Doppler ultrasonic signal,enabling earlier detection of gas kick.
基金supported by the National Natural Science Foundation of China under Grant No. 60577013the New Century Support Program for Talented Young Teachers in Universities under Grant No. NCET-04-0241
文摘Wavelength sweep technique (WST) is introduced into intra-cavity fiber laser (ICFL) for low concentration gas detection. The limitation induced by noise can be eliminated using this method, and the performance of the system is improved. The sensitivity of the system is reduced to less than 300 ppm. With WST, sweeping characteristic of the ICFL can be described according to known gas absorption spectra.
基金sponsored by the NSFC(41104066)973 Program of China(No.2014CB239006)+1 种基金NSTMP of China(Nos.2011ZX05004-003 and 2011ZX05029-003)12th 5-Year Basic Research Program of CNPC(No.2011A-3601)
文摘In heterogeneous natural gas reservoirs, gas is generally present as small patchlike pockets embedded in the water-saturated host matrix. This type of heterogeneity, also called "patchy saturation", causes significant seismic velocity dispersion and attenuation. To establish the relation between seismic response and type of fluids, we designed a rock physics model for carbonates. First, we performed CT scanning and analysis of the fluid distribution in the partially saturated rocks. Then, we predicted the quantitative relation between the wave response at different frequency ranges and the basic lithological properties and pore fluids. A rock physics template was constructed based on thin section analysis of pore structures and seismic inversion. This approach was applied to the limestone gas reservoirs of the right bank block of the Amu Darya River. Based on poststack wave impedance and prestack elastic parameter inversions, the seismic data were used to estimate rock porosity and gas saturation. The model results were in good agreement with the production regime of the wells.
基金financially supported by the National Natural Science Foundation of China(Nos.62071410 and 62101477)Hunan Provincial Natural Science Foundation(No.2021JJ40542)the Postgraduate Scientific Research Innovation Project of Hunan Province(No.CX20210627)。
文摘Owing to the ppb-level detection standard toward the toxic and harmful gas,the detection of trace gases has become an important subject in the field of indoor environment management.However,the traditional resistive gas sensors hardly meet the requirement due to the weak signal generated by trace gas molecules that are difficult to capture.Herein,a visible-light-assisted Pd/TiO_(2)gas sensor is proposed to endow the effective detection of trace formaldehyde(HCHO)gas without heating temperature.Benefiting from the enhanced photocatalytic properties of TiO_(2)by Pd decoration,the visible-light-assisted Pd/TiO_(2)gas sensor can detect the HCHO gas as low as80×10^(–9)at room temperature.The successful preparation of nanoscale TiO_(2)sensing layer is facilitated by the ultrathin carbon nanotube interdigital electrode in the gas sensor,which avoids the discontinuity of the sensing layer caused by the excessive thickness of the traditional metal electrode.In addition,the whole preparation process of the Pd/TiO_(2)gas sensor with carbon nanotube electrodes is compatible with mainstream CMOS fabrication technology,which is expected to realize the batch fabrication and micro-integrated application of gas sensors.It is expected that our work can provide a new strategy for the batch preparation of high-performance trace HCHO gas sensors and their future applications in portable electronic devices such as smartphones.
基金This work was supported by the High-end Foreign Experts Introduction Plan(No.G2021003003L)the Hebei Province Introduced Foreign Intelligence Projects(No.2022-18).
文摘Effective methods are urgently required to optimize Raman spectroscopy technology to ameliorate its low detection sensitivity.Here,we superposed two near-concentric cavities to develop a dual near-concentric cavities group(DNCCG)to assess its effect on gas Raman signal intensity,signal-to-noise ratio(SNR),and limit of detection(LOD).The results showed that DNCCG generally had higher CO_(2) Raman signal intensity than the sum of two near-concentric cavities.Meanwhile,the noise intensity of DNCCG was not enhanced by the superposition of near-concentric cavities.Accordingly,DNCCG increased the SNR.The LOD for CO_(2) was 24.6 parts per million.DNCCG could be an effective method to improve the detection capability of trace gases and broaden the dynamic detection range,which might aid the future development of innovative technology for multicomponent gas detection.
基金financially supported by the National Natural Science Foundation of China(Nos.62071410 and62101477)Hunan Provincial Natural Science Foundation of China(Nos.2021JJ40542 and 2023JJ30596)the science and technology innovation Program of Hunan Province(No.2023RC3133)。
文摘The identification of indoor harmful gases is imperative due to their significant threats to human health and safety.To achieve accurate identification,an effective strategy of constructing a sensor array combined with the pattern recognition algorithm is employed.Carbon-based thin-film transistors are selected as the sensor array unit,with semiconductor carbon nanotubes(CNTs)within the TFT channels modified with different metals(Au,Cu and Ti)for selective responses to NH_(3),H_(2)S and HCHO,respectively.For accurate gas species identification,an identification mode that combines linear discriminant analysis algorithms and logistic regression classifier is developed.The test results demonstrate that by preprocessing the sensor array’s sensing data with the LDA algorithm and subsequently employing the LR classifier for identification,a 100%recognition rate can be achieved for three target gases(NH3,H2S and HCHO).This work provides significant guidance for future applications of chip-level gas sensors in the realms of the Internet of Things and Artificial Intelligence.
基金supported by the Project Grant from Heilongjiang Bayi Agricultural Reclamation University,Heilongjiang,China (No.XDB201813)。
文摘High-precision methane gas detection is of great importance in industrial safety, energy production and environmental protection, etc. However, in the existing measurement techniques, the methane gas concentration information is susceptible to noise, which leads to its useful signal being drowned by noise. A fusion algorithm of variational modal decomposition(VMD) and improved wavelet threshold filtering is proposed, which is used in combination with tunable diode laser absorption spectroscopy(TDLAS) to implement a non-contact, high-resolution methane gas concentration detection. The fusion algorithm can perform noise reduction and further segmentation of the methane gas detection signal. And the simulation and experiment verify the effectiveness of the fusion algorithm, and the experimental results show that for the detection of air containing 10 ppm, 30 ppm, 60 ppm, 80 ppm, and 99 ppm methane, the errors are 12.75%, 8.18%, 3.37%, 2.46%, and 1.78%, respectively.
基金supported by the National Natural Science Foundation of China(Grant No.51704327)
文摘In the petroleum industry,detection of multi-phase fluid flow is very important in both surface and down-hole measurements.Accurate measurement of high rate of water or gas multi-phase flow has always been an academic and industrial focus.NMR is an efficient and accurate technique for the detection of fluids;it is widely used in the determination of fluid compositions and properties.This paper is aimed to quantitatively detect multi-phase flow in oil and gas wells and pipelines and to propose an innovative method for online nuclear magnetic resonance(NMR)detection.The online NMR data acquisition,processing and interpretation methods are proposed to fill the blank of traditional methods.A full-bore straight tube design without pressure drop,a Halbach magnet structure design with zero magnetic leakage outside the probe,a separate antenna structure design without flowing effects on NMR measurement and automatic control technology will achieve unattended operation.Through the innovation of this work,the application of NMR for the real-time and quantitative detection of multi-phase flow in oil and gas wells and pipelines can be implemented.
基金the Fund of Acoustics Science and Technology Laboratory(KY1050019005,KY1050019006,KY10500180084)National Natural Science Foundation of China(Nos.41304096,41876053)+3 种基金the Fundamental Research Funds for the Central Universities(HEUCFJ180503)the National Science and Technology Major Project of China(2016ZX05024-001-002)National key research and development plan(2017YFC0307401)Fundamental Research Funds for the Central Universities(201762019).
文摘Higher-precision determinations of hydrate reservoirs, hydrate saturation levels and storage estimations are important for guaranteeing the ability to continuously research, develop and utilize natural gas hydrate resources in China. With seismic stereoscopic detection technology, which fully combines the advantages of different seismic detection models, hydrate formation layers can be observed with multiangle, wide-azimuth, wide-band data with a high precision. This technique provides more reliable data for analyzing the distribution characteristics of gas hydrate reservoirs, establishing velocity models, and studying the hydrate-sensitive properties of petrophysical parameters;these data are of great significance for the exploration and development of natural gas hydrate resources. Based on a velocity model obtained from the analysis of horizontal streamer velocity data in the hydrate-bearing area of the Shenhu Sea, this paper uses three VCs(longitudinal spacing of 25 m) and four OBSs(transverse spacing of 200 m) to jointly detect seismic datasets consisting of wave points based on an inversion of traveltime imaging sections. Accordingly, by comparing the differences between the seismic phases in the original data and the forward-modeled seismic phases, multiangle coverage constraint corrections are applied to the initial velocity model, and the initial model is further optimized, thereby improving the imaging quality of the streamer data. Petrophysical elastic parameters are the physical parameters that are most directly and closely related to rock formations and reservoir physical properties. Based on the optimized velocity model, the rock elastic hydrate-sensitive parameters of the hydrate reservoirs in the study area are inverted, and the sensitivities of the petrophysical parameters to natural gas hydrates are investigated. According to an analysis of the inversion results obtained from these sensitive parameters, λρ, Vp and λμ are simultaneously controlled by the bulk modulus and shear modulus, while Vs and μρ are controlled only by the shear modulus, and the latter two parameters are less sensitive to hydrate-bearing layers. The bulk modulus is speculated to be more sensitive than the shear modulus to hydrates. In other words, estimating the specific gravity of the shear modulus among the combined parameters can affect the results from the combined elastic parameters regarding hydrate reservoirs.
基金Supported by the National Natural Science Foundation of China(51474184)the Natural Science Foundation of the State Administration of Work Safety in China(2012-387,Sichuan-0021-2016AQ)
文摘Hazardous gas detection systems play an important role in preventing catastrophic gas-related accidents in process industries. Even though effective detection technology currently exists for hazardous gas releases and a majority of process installations have a large number of sensitive detectors in place, the actual operating performance of gas detection systems still does not meet the expected requirements. In this paper, a riskbased methodology is proposed to optimize the placement of hazardous gas detectors. The methodology includes three main steps, namely, the establishment of representative leak scenarios, computational fluid dynamics(CFD)-based gas dispersion modeling, and the establishment of an optimized solution. Based on the combination of gas leak probability and joint distribution probability of wind velocity and wind direction, a quantitative filtering approach is presented to select representative leak scenarios from all potential scenarios. The commercial code ANSYS-FLUENT is used to estimate the consequence of hazardous gas dispersions under various leak and environmental conditions. A stochastic mixed-integer linear programming formulation with the objective of minimizing the total leak risk across all representative leak scenarios is proposed, and the greedy dropping heuristic algorithm(GDHA) is used to solve the optimization model. Finally, a practical application of the methodology is performed to validate its effectiveness for the optimal design of a gas detector system in a high-sulfur natural gas purification plant in Chongqing, China. The results show that an appropriate number of gas detectors with optimal cost-effectiveness can be obtained, and the total leak risk across all potential scenarios can be substantially reduced. This methodology provides an effective approach to guide the optimal placement of pointtype gas detection systems involved with either single or mixed gas releases.
基金Project(51004005) supported by the National Natural Science Foundation of ChinaProject supported by Open Research Fund Program of Beijing Engineering Research Center of Monitoring for Construction Safety (Beijing University of Civil Engineering and Architecture), China
文摘For solving the difficult problem of leakage detection in city gas pipelines, a method using acoustic technique based on instantaneous energy (IE) distribution and correlation analysis was proposed. Firstly, the basic theory of leakage detection and location was introduced. Then the physical relationship between instantaneous energy and structural state variation of a system was analyzed theoretically. With HILBERT-HUANG transformation (HHT), the instantaneous energy distribution feature of an unstable acoustic signal was obtained. According to the relative contribution method of the instantaneous energy, the noise in signal was eliminated effectively. Furthermore, in order to judge the leakage, the typical characteristic of the instantaneous energy of signal in the input and output end was discussed using correlative analysis. A number of experiments were carried out to classify the leakage from normal operations, and the results show that the leakages are successfully detected and the average recognition rate reaches 93.3% among three group samples. It is shown that the method using acoustic technique with IED and correlative analysis is effective and it may be referred in other pipelines.