期刊文献+
共找到9篇文章
< 1 >
每页显示 20 50 100
Understanding the combustion behavior of electric bicycle batteries and unveiling its relationship with fire extinguishing
1
作者 Zhanglong Yu Xueling Shen +6 位作者 Ran Xu Zheng Wang Zengming Wan Mingyang Chen Yi Cui Yanyan Fang Xiaoli Ma 《Journal of Energy Chemistry》 SCIE EI CAS CSCD 2024年第4期609-618,共10页
In this study,a detailed analysis of the combustion behaviors of the lithium iron phosphate(LFP)and lithium manganese oxide(LMO)batteries used in electric bicycles was conducted.This research included quantitative mea... In this study,a detailed analysis of the combustion behaviors of the lithium iron phosphate(LFP)and lithium manganese oxide(LMO)batteries used in electric bicycles was conducted.This research included quantitative measurements of the combustion duration,flame height,combustion temperature,heat release rate,and total heat release.The results indicated that LMO batteries exhibited higher combustion temperatures of 600–700°C,flame heights of 70–75 cm,a significantly higher heat release rate of40.1 k W(12 Ah),and a total heat release of 1.04 MJ(12 Ah)compared to LFP batteries with the same capacity.Based on these experimental results,a normalized total heat release(NORTHR)parameter was proposed,demonstrating good universality for batteries with different capacities.Utilizing this parameter,quantitative calculations and optimization of the extinguishing agent dosage were conducted for fires involving these two types of batteries,and the method was validated by extinguishing fires for these two types of battery packs with water-based extinguishing fluids. 展开更多
关键词 Combustion behavior Electric bicycle Lithium-ion battery fire extinguishing Normalized total heat release
下载PDF
Research Progress of Polymer Fire Extinguishing Gel and Its Application in Forest Fire Prevention
2
作者 Zhifeng XU Nianci ZHANG 《Plant Diseases and Pests》 2024年第2期37-40,共4页
The paper summarizes the structure and water-absorbing mechanism,classification,and preparation method of polymer fire extinguishing gel,and prospects for its application in aerial firefighting,forest ground fire exti... The paper summarizes the structure and water-absorbing mechanism,classification,and preparation method of polymer fire extinguishing gel,and prospects for its application in aerial firefighting,forest ground fire extinguishing,opening of firebreaks,and mitigating human casualties in forest fire extinguishing. 展开更多
关键词 Polymer fire extinguishing gel Water-absorbing mechanism Forest fire prevention
下载PDF
Enhancing Fire Safety in Commercial Vehicles: Assessing the Efficacy and Advantages of Exploding Fire Extinguishing Balls
3
作者 Paul W. Ford 《Journal of Transportation Technologies》 2024年第4期521-548,共28页
Fire incidents in commercial vehicles pose significant risks to passengers, drivers, and cargo. Traditional fire extinguishing systems, while effective, may have limitations in terms of response time, coverage, and hu... Fire incidents in commercial vehicles pose significant risks to passengers, drivers, and cargo. Traditional fire extinguishing systems, while effective, may have limitations in terms of response time, coverage, and human intervention [1]. This study investigates the efficacy of a novel fire suppression technology—the Exploding Fire Extinguishing Ball (EFEB) —as an alternative and complementary fire safety solution for commercial vehicles. The research employs a multidisciplinary approach, encompassing engineering, materials science, fire safety, and human factors analysis. A systematic literature review establishes a comprehensive understanding of existing fire suppression technologies, including EFEBs. Subsequently, this study analyzes the unique features of EFEBs, such as automatic activation, as well as manual activation upon exposure to fire, and their potential to provide rapid, localized, and autonomous fire suppression. The study presents original experimental investigations to assess the performance and effectiveness of EFEBs in various fire scenarios representative of commercial vehicles. Experiments include controlled fires in confined spaces and dynamic simulations to emulate real-world fire incidents. Data on activation times, extinguishing capability, and coverage area are collected and analyzed to compare the efficacy of EFEBs with traditional fire extinguishing methods. Furthermore, this research shows the practical aspects of implementing EFEBs in commercial vehicles. A feasibility study examines the integration challenges, cost-benefit analysis, and potential regulatory implications. The study also addresses the impact of EFEBs on vehicle weight, stability, and overall safety. Human factors and user acceptance are crucial elements in adopting new safety technologies. Therefore, this research utilizes an experimental design to assess the performance and effectiveness of EFEBs in various fire scenarios representative of commercial vehicles. This dissertation presents original controlled experiments to emulate real-world fire incidents, including controlled fires in confined spaces and dynamic simulations. The experimental approach ensures rigorous evaluation and objective insights into EFEBs’ potential as an autonomous fire suppression system for commercial vehicles. This includes the perspectives of drivers, passengers, fleet operators, insurance agencies, and regulatory bodies. Factors influencing trust, perceived safety, and willingness to adopt EFEBs are analyzed to provide insights into the successful integration of this technology. The findings of this research will contribute to the knowledge of fire safety technology and expand the understanding of the applicability of EFEBs in commercial vehicles. 展开更多
关键词 Exploding fire extinguishing Balls Commercial Vehicles fire Suppression fire Safety Technology Human Factors Usability Feasibility Study
下载PDF
“Relay-mode”promoting permeation of water-based fire extinguishing agent in granular materials porous media stacks
4
作者 Kang Wang Wei Tan Liyan Liu 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2022年第7期98-112,共15页
Water-based fire extinguishing agent is the main means to deal with smoldering fires.However,due to the hydrophobic properties of the particle surface,the porous medium channel provide resistance and slow down the ext... Water-based fire extinguishing agent is the main means to deal with smoldering fires.However,due to the hydrophobic properties of the particle surface,the porous medium channel provide resistance and slow down the extinguishing agent flow during the downward permeation process.To promote the liquid permeation process in such porous media,this work studied liquid imbibition process and analyzed the oscillating and attenuating process of liquid level in capillary channel by theoretical,experimental,and numerical methods.An empirical mathematical equation was proposed to describe the oscillating process,and the effects of the capillary diameter and contact angle parameters on the transportation process were analyzed.Based on this,the“relay-mode”was proposed to promote the liquid transportation forward.Finally,the transient simulation results of liquid permeation in coal stacks showed when the liquid flowed through the channel with changed diameter from large to small ones,the transportation distance was several times longer than that through the unidiameter ones.The trend of liquid“relay-mode”in capillaries can be used to promote the permeation in granular materials porous media stacks.The relevant results also provide new thoughts to develop the water-based fire extinguishing agents and then improve the firefighting efficiency of deep-seated fire in porous media stacks. 展开更多
关键词 Granular materials Porous media Safety PERMEATION Water-based fire extinguishing agent
下载PDF
Design of Intelligent Fire Alarm System for Large Storage Places Based on AVRmega128 Single Chip Microcomputer
5
作者 杨东星 李明儒 +1 位作者 刘南君 毛培宏 《Agricultural Science & Technology》 CAS 2014年第4期692-696,共5页
With principles of reliability, independence, practicality and economical effi- ciency, a set of intelligent fire alarm system based on AVRmega128 single chip microcomputer was designed to solve problems of fire alarm... With principles of reliability, independence, practicality and economical effi- ciency, a set of intelligent fire alarm system based on AVRmega128 single chip microcomputer was designed to solve problems of fire alarm system in many large- scale warehouses. Using advanced flame sensor, 485 bus communication, computer interactive software and related peripheral devices, this intelligent fire alarm system has functions of sound-light alarm and intelligent fire extinguishing. The human-com- puter interactive software was adopted for the remote control of the alarm main control panel through the 485 bus communication. This design of intelligent fire alarm system shows high reference and practical value to the development of intel- ligent alarm products with high integration and high reliability. 展开更多
关键词 AVRmega128 single chip microcomputer 485 bus communication Audi- ble and visual alarm Intelligent fire extinguishing Human-computer interaction
下载PDF
Research on the effect of the component proportion in the new water mist additive on firefighting performance 被引量:1
6
作者 Ji Huanle Zhang Qingsong +1 位作者 Wu Binbin Liang Tianshui 《Engineering Sciences》 EI 2013年第6期85-90,共6页
Water mist technology provides efficient firefighting performance while there is still room for improvement. So varieties of additives have been studied in recent years both at home and abroad. The self-made additives... Water mist technology provides efficient firefighting performance while there is still room for improvement. So varieties of additives have been studied in recent years both at home and abroad. The self-made additives are used to compare the firefighting performance of diesel and heptane fire in open space. By adjusting the concentration of substance in the additives and conducting the experiment under the pressure of 0.3 MPa,0.5 MPa and 0.7 MPa,extinguish time and temperature are measured in the experiment. Through the experiments using different fuels,it can be found when the fuel is heptane that has a lower ignition point and a higher evaporation rate, the water mist additive can still significantly improve the firefighting performance. According to the data based on different concentrations of fluorinated surfactants,we find that fluorinated surfactants are the main substance to improve the performances by changing physical property of water mist. Optimal proportion of the additives for firefighting performance is found by experiment results. 展开更多
关键词 water mist additive firefighting performance additive proportion fire extinguishing mechanisms
下载PDF
超细干粉灭火剂 被引量:13
7
作者 周文英 杜泽强 +1 位作者 介燕妮 寇静利 《中国粉体技术》 CAS 2005年第1期42-44,共3页
首先简介了干粉灭火剂的种类、特点、性能,讨论了燃烧机理、传统干粉灭火剂及其灭火原理,重点探讨了灭火剂粒径与灭火效能之间的关系,发现灭火效能随粒径减少而急剧增加。最后,探讨了超细粒径干粉灭火剂的性能、研制和生产情况、优势及... 首先简介了干粉灭火剂的种类、特点、性能,讨论了燃烧机理、传统干粉灭火剂及其灭火原理,重点探讨了灭火剂粒径与灭火效能之间的关系,发现灭火效能随粒径减少而急剧增加。最后,探讨了超细粒径干粉灭火剂的性能、研制和生产情况、优势及前景,并分析了纳米干粉灭火剂的性能和应用前景。 展开更多
关键词 超细粉体 干粉灭火剂 灭火效能
下载PDF
氢氧化镁对磷酸二氢铵灭火剂性能的影响
8
作者 刘英炎 陈巍 +2 位作者 谭小群 邓贞贞 黄嘉欣 《广东化工》 CAS 2015年第3期33-34,共2页
在市售以磷酸二氢铵为灭火基料的ABC干粉灭火剂中加入氢氧化镁,利用自制实验装置对干粉灭火剂进行灭火性能、灭火温降实验测试。实验结果表明:氢氧化镁含量低于10%时,灭火剂灭火性能没有改善;氢氧化镁含量为20%时,干粉灭火效率、灭火后... 在市售以磷酸二氢铵为灭火基料的ABC干粉灭火剂中加入氢氧化镁,利用自制实验装置对干粉灭火剂进行灭火性能、灭火温降实验测试。实验结果表明:氢氧化镁含量低于10%时,灭火剂灭火性能没有改善;氢氧化镁含量为20%时,干粉灭火效率、灭火后温降速率明显提高。 展开更多
关键词 氢氧化镁 磷酸二氢铵 干粉灭火剂 灭火性能
下载PDF
Investigation on the characteristics and mechanism of AZ80A magnesium alloy corrosion by Halon 1301 and CF_(3)I
9
作者 Xin Huang Huilin Bai +1 位作者 Yujia Huo Xiaomeng Zhou 《Aerospace Traffic and Safety》 2024年第1期73-83,共11页
In order to study the application of gas fire extinguishing agents in civil aircraft fire extinguishing systems,the corrosion characteristics and mechanisms of Halon 1301 and CF_(3)I on AZ80A magnesium alloy were comp... In order to study the application of gas fire extinguishing agents in civil aircraft fire extinguishing systems,the corrosion characteristics and mechanisms of Halon 1301 and CF_(3)I on AZ80A magnesium alloy were comparatively analyzed.The experimental methods combined with density functional theory were applied to explore the corrosion mechanism.The results indicate that Halon 1301 and CF_(3)I exhibit good compatibility with AZ80A magnesium alloy through physical adsorption at room temperature and pressure,where Halon 1301 has a more stable adsorption configuration.However,with increasing temperature,pyrolysis reactions occur leading to the formation of fluorine containing corrosive substances which can react with magnesium alloy to generate the corrosion production of MgF_(2) and coke.Although MgF_(2) and coke can partically reduce reaction rates and protect against corrosion,the presence of MgF_(2) promotes further pyrolysis,generating more corrosion products.Consequently,the accumulation of corrosion products leads to a loss of metallic luster and a decline in mechanical properties of magnesium alloy along with interfacial cracking due to mutual extrusion between MgF_(2) and carbon deposition layers.These studies offer theoretical guidance for utilizing CF_(3)I in civil aircraft fire extinguishing systems while facilitating rapid screening for efficient clean gas extinguishing agents. 展开更多
关键词 Gas fire extinguishing agents AZ80A magnesium alloy Corrosion products Corrosion mechanism CF_(3)I
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部