As an important part of nonstructural components,the seismic response of indoor water supply pipes deserves much attention.This paper presents shaking table test research on water supply pipes installed in a full-scal...As an important part of nonstructural components,the seismic response of indoor water supply pipes deserves much attention.This paper presents shaking table test research on water supply pipes installed in a full-scale reinforced concrete(RC)frame structure.Different material pipes and different methods for penetrating the reinforced concrete floors are combined to evaluate the difference in seismic performance.Floor response spectra and pipe acceleration amplification factors based on test data are discussed and compared with code provisions.A seismic fragility study of displacement demand is conducted based on numerical simulation.The acceleration response and displacement response of different combinations are compared.The results show that the combination of different pipe materials and different passing-through methods can cause obvious differences in the seismic response of indoor riser pipes.展开更多
In 2023,two consecutive earthquakes exceeding a magnitude of 7 occurred in Türkiye,causing severe casualties and economic losses.The damage to critical urban infrastructure and building structures,including highw...In 2023,two consecutive earthquakes exceeding a magnitude of 7 occurred in Türkiye,causing severe casualties and economic losses.The damage to critical urban infrastructure and building structures,including highways,railroads,and water supply pipelines,was particularly severe in areas where these structures intersected the seismogenic fault.Critical infrastructure projects that traverse active faults are susceptible to the influence of fault movement,pulse velocity,and ground motions.In this study,we used a unique approach to analyze the acceleration records obtained from the seismic station array(9 strong ground motion stations)located along the East Anatolian Fault(the seismogenic fault of the MW7.8 mainshock of the 2023 Türkiye earthquake doublet).The acceleration records were filtered and integrated to obtain the velocity and displacement time histories.We used the results of an on-site investigation,jointly conducted by China Earthquake Administration and Türkiye’s AFAD,to analyze the distribution of PGA,PGV,and PGD recorded by the strong motion array of the East Anatolian Fault.We found that the maximum horizontal PGA in this earthquake was 3.0 g,and the maximum co-seismic surface displacement caused by the East Anatolian Fault rupture was 6.50 m.As the fault rupture propagated southwest,the velocity pulse caused by the directional effect of the rupture increased gradually,with the maximum PGA reaching 162.3 cm/s.We also discussed the seismic safety of critical infrastructure projects traversing active faults,using two case studies of water supply pipelines in Türkiye that were damaged by earthquakes.We used a three-dimensional finite element model of the PE(polyethylene)water pipeline at the Islahiye State Hospital and fault displacement observations obtained through on-site investigation to analyze pipeline failure mechanisms.We further investigated the effect of the fault-crossing angle on seismic safety of a pipeline,based on our analysis and the failure performance of the large-diameter Thames Water pipeline during the 1999 Kocaeli earthquake.The seismic method of buried pipelines crossing the fault was summarized.展开更多
This research project investigates the current status of water supply, sanitation, and hygiene practices in Munshiganj District, Bangladesh. Data collection involved a structured questionnaire and a reconnaissance sur...This research project investigates the current status of water supply, sanitation, and hygiene practices in Munshiganj District, Bangladesh. Data collection involved a structured questionnaire and a reconnaissance survey. Findings reveal that 30% of individuals rely on surface water (hand-tube wells, rivers, and ponds), prioritized as canal > river > pond, while 70% depend on groundwater (subterranean electric motor, deep tube-well). Drinking water is generally sufficient, with 95% reporting adequacy throughout the year. About 45% use hand tube-well water, 28% use deep tube-well water, and 11% use supply tap water for various purposes. Bathing trends include underground water through electric motor > pond > hand tube-well water > river, while for cooking, the order is underground water through electric motor > pond > hand tube-well water > river. Toilet water supply ranks as supply tap water > hand tube-well water > deep tube-well water. Although sanitation awareness is high, some lack knowledge of good hygiene practices. After defecating, handwashing methods include soap, ash, soil, or water. Children’s waste disposal varies, with some discarding it in open areas. Approximately 40% suffer from diseases like Diarrhoea due to unsafe water, primarily affecting children and elders. Training exists, but a significant portion lacks sanitation education. Dry skin or exposure to cold water may cause temporary irritation. Local government involvement in sanitation efforts is less active compared to non-governmental organizations. Results emphasize the need to enhance community awareness of safe water supplies and sanitation practices. .展开更多
With the acceleration of urbanization,the demand for water supply and drainage pipe networks has increased significantly.In the planning of urban construction,it is necessary to optimize the design of the water supply...With the acceleration of urbanization,the demand for water supply and drainage pipe networks has increased significantly.In the planning of urban construction,it is necessary to optimize the design of the water supply and drainage system pipe network to effectively save energy while providing residents with more accessible water resources.Therefore,the municipal water supply and drainage system and the water transmission methods should be designed according to the geographical conditions of the city.In this paper,we mainly analyze the design of municipal water supply and drainage systems and the selection of water transmission methods.Besides,the optimization of the water supply and drainage network zoning process and pipe network maintenance is also discussed,so as to provide a reference for municipal water supply and drainage work.展开更多
The quality and safety of residents’water rely heavily on the design of municipal water supply and drainage pipes.Therefore,this paper aims to enhance the optimization of municipal water supply and drainage pipe desi...The quality and safety of residents’water rely heavily on the design of municipal water supply and drainage pipes.Therefore,this paper aims to enhance the optimization of municipal water supply and drainage pipe design by focusing on design requirements,principles,and key elements.Drawing from relevant design optimization experiences,technology advancements,and optimization measures,the research will analyze and consolidate the essential aspects of municipal water supply and drainage pipe design.The goal is to fundamentally elevate the quality standards of these designs,ensuring they meet the criteria for engineering project excellence.Through this comprehensive approach,we aim to contribute to the improvement and sustainability of water supply and drainage systems,safeguarding the well-being of residents.展开更多
For a water supply system with long-distance diversion pipelines, in addition to the water hammer problems that occur beyond pumps, the safety of the water diversion pipeline in front of pumps also deserves attention....For a water supply system with long-distance diversion pipelines, in addition to the water hammer problems that occur beyond pumps, the safety of the water diversion pipeline in front of pumps also deserves attention. In this study, a water hammer protection scheme combined with an overflow surge tank and a regulating valve was developed. A mathematical model of the overflow surge tank was developed, and an analytical formula for the height of the overflow surge tank was derived. Furthermore, a practical water supply project was used to evaluate the feasibility of the combined protection scheme and analyze the sensitivity of valve regulation rules. The results showed that the combined protection scheme effectively reduced the height of the surge tank, lessened the difficulties related to construction, and reduced the necessary financial investment for the project. The two-stage closing rule articulated as fast first and then slow could minimize the overflow volume of the surge tank when the power failure occurred, while the two-stage opening rule articulated as slow first and then fast could be more conducive to the safety of the water supply system when the pump started up.展开更多
Tailoring water supply to achieve confined heating has proven to be an effective strategy for boosting solar interfacial evaporation rates.However,because of salt clogging during desalination,a critical point of const...Tailoring water supply to achieve confined heating has proven to be an effective strategy for boosting solar interfacial evaporation rates.However,because of salt clogging during desalination,a critical point of constriction occurs when controlling the water rate for confined heating.In this study,we demonstrate a facile and scalable weaving technique for fabricating core-sheath photothermal yarns that facilitate controlled water supply for stable and efficient interracial solar desalination.The core-sheath yarn comprises modal fibers as the core and carbon fibers as the sheaths.Because of the core-sheath design,remarkable liquid pumping can be enabled in the carbon fiber bundle of the dispersed superhydrophilic modal fibers.Our woven fabrics absorb a high proportion(92%)of the electromagnetic radiation in the solar spectrum because of the weaving structure and the carbon fiber sheath.Under one-sun(1 kW·m^(-2))illumination,our woven fabric device can achieve the highest evaporation rate(of 2.12kg·m^(-2)·h^(-1) with energy conversion efficiency:93.7%)by regulating the number of core-sheath yarns.Practical application tests demonstrate that our device can maintain high and stable desalination performance in a 5 wt%NaCl solution.展开更多
At present,the leakage rate of the water distribution network in China is still high,and the waste of water resources caused by water distribution network leakage is quite serious every year.Therefore,the location of ...At present,the leakage rate of the water distribution network in China is still high,and the waste of water resources caused by water distribution network leakage is quite serious every year.Therefore,the location of pipeline leakage is of great significance for saving water resources and reducing economic losses.Acoustic emission technology is the most widely used pipeline leak location technology.The traditional non-stationary random signal de-noising method mainly relies on the estimation of noise parameters,ignoring periodic noise and components unrelated to pipeline leakage.Aiming at the above problems,this paper proposes a leak location method for water supply pipelines based on a multivariate variational mode decomposition algorithm.This method combines the two parameters of the energy loss coefficient and the correlation coefficient between adjacent modes,and adaptively determines the decomposition mode number K according to the characteristics of the signal itself.According to the correlation coefficient,the effective component is selected to reconstruct the signal and the cross-correlation time delay is estimated to determine the location of the pipeline leakage point.The experimental results show that this method has higher accuracy than the cross-correlation method based on VMD and the cross-correlation method based on EMD,and the average relative positioning error is less than 2.2%.展开更多
With the continuous development of society and the market economy,people are putting forward higher and higher requirements for the construction,technology,and environmental friendliness of buildings.The prefabricated...With the continuous development of society and the market economy,people are putting forward higher and higher requirements for the construction,technology,and environmental friendliness of buildings.The prefabricated building not only has high installation efficiency,but is also safe and environmentally friendly,which is in line with the green building concept.The drainage design is a critical part of prefabricated buildings.In order to ensure the quality and construction efficiency of the building project,it is necessary to design the building water supply and drainage properly.Therefore,an in-depth investigation on prefabricated buildings was carried out in this paper,and water supply and drainage design for prefabricated buildings under the green building concept is proposed,in hopes of providing references for future water supply and drainage designs.展开更多
The potability of drinking water depends not only on the source and the treatment system, but also on the quality of the waterworks. In fact, the quality of drinking water is considerably degraded by the dilapidated s...The potability of drinking water depends not only on the source and the treatment system, but also on the quality of the waterworks. In fact, the quality of drinking water is considerably degraded by the dilapidated state and lack of maintenance of drinking water networks. In Côte d’Ivoire, the majority of drinking water networks in the various towns are ageing. In Daloa, despite the efforts made by the company in charge of water treatment and distribution to make the water drinkable, the water at consumers’ taps is often colored, has an unpleasant aftertaste and settles after collection. As a result, people are concerned about the potability of tap water, and some are turning to alternative sources of drinking water of unknown quality. In order to determine the factors responsible for the deterioration in water color and taste, as well as the sectors of the network most affected, a diagnosis of the network’s equipment was carried out. Water samples taken from the network were analyzed for color and turbidity. The diagnosis revealed that most of the equipment (suction pads, valves, drains and fire hydrants) is outdated and irregularly maintained. Analyses show that the water is more colored in cast-iron and PVC pipes than in asbestos cement pipes. Coloration values in the network range from 0 to 27 UVC for asbestos cement pipes, from 15 to 56 UCV for ductile iron pipes, and from 11 to 102 UCV for PVC pipes. On the over hand, turbidity values vary from 8.02 to 3.32 NTU for ductile cast iron pipes, 8.51 to 16.98 NTU for asbestos cement pipes and 0.9 to 6.98 NTU for PVC pipes. Old cast-iron pipes release ferric ions on contact with water, degrading their color. Old cast-iron pipes release ferric ions into the water, degrading its color. The high color values observed in the vicinity of drains are thought to be due to irregular maintenance of the network. In fact, after network maintenance, a reduction rate ranging from 2% to 73% is observed for turbidity, while for color, the rate varies from 5% to 72%. In short, the network’s obsolescence and irregular maintenance contribute significantly to the deterioration of water quality.展开更多
This study used multinomial logistic regression and Bayesian belief networks(BBN)to analyze factors influenc-ing the functionality of the community-based rural drinking water supply and sanitation program(PAMSIMAS)in ...This study used multinomial logistic regression and Bayesian belief networks(BBN)to analyze factors influenc-ing the functionality of the community-based rural drinking water supply and sanitation program(PAMSIMAS)in Indonesia.28,936 PAMSIMAS projects in 33 provinces in Indonesia were analyzed.The data indicates that 85.4%of the water supply systems were fully functioning,9.1%were partially functioning,and 5.5%were not functioning.In the regression analysis,good management is positively associated with functionality and a high investment per capita is negatively associated with the functionality.The latter suggests the need for comprehen-sive economic analysis in the feasibility study in scattered housing sites and remote-undeveloped areas.We also found that high community participation at the beginning of the project was associated with the not functioning system,while women’s participation was positively associated with the functionality.Furthermore,the household connection is more likely to be functioning than communal connection.BBN analysis shows if the beneficiaries do not pay for water,the probability of not functioning systems is 20 times higher than systems with fee collec-tion.Moreover,the combination of strong management,strong financial status,and household connection rather than communal connection increases the probability of fully functioning to 98%.Improvement of data collection is also necessary to monitor the current conditions of all PAMSIMAS systems in Indonesia.This study offers a country-level perspective for better implementation of the community-based rural water supply and sanitation program in developing countries.展开更多
During the Northern Warlord Period(1912–1928),the construction industry in Shanghai underwent robust development.As an integral element of buildings,equipment served both functional purposes and stood witness to the ...During the Northern Warlord Period(1912–1928),the construction industry in Shanghai underwent robust development.As an integral element of buildings,equipment served both functional purposes and stood witness to the evolution of the economy and society,thus earning its place as part of the architectural heritage.However,due to various reasons,there are many loopholes in the protection of these building equipment.This paper examines the development of building equipment in Shanghai during the Northern Warlord Period,using water supply,drainage,and heating,ventilation,and air conditioning(HVAC)systems as examples.Through historical context analysis,it summarizes this development from a social-spatial perspective,infers the reasons behind it,and analyzes the importance of preserving such equipment,considering both past and present viewpoints.In this research,the importance of protecting historical building equipment is emphasized,which aims to give people a deeper understanding of their cultural value,and suggests that scholars conduct more practical research on their protection.展开更多
[Objective] The aim was to study the effects of water supply and consumption on water saving and drought resistance. [Method] Controlling field experiment was conducted to explore water balance between supply and dema...[Objective] The aim was to study the effects of water supply and consumption on water saving and drought resistance. [Method] Controlling field experiment was conducted to explore water balance between supply and demand in paddy fields in hilly regions in Sichuan Province. [Result] Rainfall in hilly areas was 3 611.10 m3/hm2; water for irrigation was 6 299.25 m3/hm2; evapotranspiration of rice was 6 424.95 m3/hm2; deep leakage was 2 459.55 m3/hm2; overflowing amount was 1 026.00 m3/hm2. In addition, water consumption totaled 8 884.50 m3/hm2 during rice production; water use was 0.99 kg/m3 and use efficiency of irrigated water was 1.40 kg/m3. [Conclusion] Water supply and consumption should be further organized to save water and fight against drought in hilly areas in Sichuan Province.展开更多
The paper had analyzed the technology, maintenance and recognition of vertical greening in urban space, and proposed a solution for balance water supply for balconies and streetlights, that is, magnetic auxiliary shal...The paper had analyzed the technology, maintenance and recognition of vertical greening in urban space, and proposed a solution for balance water supply for balconies and streetlights, that is, magnetic auxiliary shallow water level controller, the patent of which had been applied. Magnetic auxiliary shallow water level controller had met water supply of some special parts of urban vertical greening and was sure to accelerate urban vertical greening.展开更多
[Objective] The purpose of this study is to estimate water supply and demand, which can provide a basis for how to allocate rationally water resources in Hotan Oasis. [Method] The water supply and demand in Hotan Oasi...[Objective] The purpose of this study is to estimate water supply and demand, which can provide a basis for how to allocate rationally water resources in Hotan Oasis. [Method] The water supply and demand in Hotan Oasis in the next15 years were calculated according to water-soil balance. [Result] When the runoff of Hotan River is at a probability of 50%(P=50 for short), the total water resource is 50.57×10^8m^3, and there is only 33.13×10^8m^3available for social and economics,but there would be a need of 33.44×10^8and 36.06×10^8m^3, and the water shortage would be 1.31 ×10^8and 2.93 ×10^8m^3in 2020 and 2030 respectively. When P =75,the total water resource is 44.30×10^8m^3, there is only 29.39×10^8m^3water available for social and economics. However, there would be a need of 31.43 ×10^8and33.11×10^8m^3, and the water shortage would be 2.04×10^8and 3.72×10^8m^3in 2020 and 2030, respectively. [Conclusion] The problem of water shortage would be serious over the next 15 years, and the fragile ecosystem would be destroyed dramatically with the large-scale land reclamation against natural laws. Hence, the effective policies and measures should be taken timely to prohibit reclamation and to cope with ongoing water shortage, based on the water supply and demand estimation under the background of climate change.展开更多
In this research, LINGO is used successfully to solve the water supply system′s optimal operation model. Firstly, the language of LINGO and the using method were studied intensively, on the basis of which the model w...In this research, LINGO is used successfully to solve the water supply system′s optimal operation model. Firstly, the language of LINGO and the using method were studied intensively, on the basis of which the model was transformed to LINGO form and solved successfully. Secondly, the research on the interface between LINGO and the popular office software was made. The optimization software was developed, which had Excel as the workspace and LINGO as the core of computation. Through practice, this software was found stable, easy to use and suitable for the application to the water supply corporations.展开更多
Based on the data for meteorology, hydrology, soil, planting, vegetation, and socio-economic development of the irrigation region in the middle reaches of the Heihe River basin, Northwest China, the model of balance o...Based on the data for meteorology, hydrology, soil, planting, vegetation, and socio-economic development of the irrigation region in the middle reaches of the Heihe River basin, Northwest China, the model of balance of water supply and demand in the region was established, and the security of water resource was assessed, from which the results that the effects of unified management of water resources in the Heihe River basin between Gansu Province and Inner Mongolia on regional hydrology are significant with a decrease in water supply diverted from Heihe River and an increase in groundwater extracted. In addition, it was found that the groundwater level has been steadily decreasing due to over pumping and decrease in recharges. In present year (2003), the volume of potential groundwater in the irrigation districts is far small because of the groundwater overdraft; even in the particular regions, there is no availability of groundwater resources for use. By 2003, water supply is not sufficient to meet the water demand in the different irrigation districts, the sustainable development and utilization of water resources are not secured, and the water supply crisis occurs in Pingchuan irrigation district. Achieving water security for the sustainable development of society, agriculture, economy, industry, and livelihoods while maintaining or improving the abilities of the management and planning of water resources, determining of the reasonable percentage between water supply and groundwater utilization and water saving in agricultural irrigation are taken into account. If this does not occur, it is feared that the present performance of water development and planning may further aggravate the problem of scarcities of water resources and further damage the fragile ecological system.展开更多
In semiarid areas, cereal crops often alocate more biomass to root at the expense of aboveground yield. A pot experiment was conducted to investigate carbon consumption of roots and its impact on grain yield of spring...In semiarid areas, cereal crops often alocate more biomass to root at the expense of aboveground yield. A pot experiment was conducted to investigate carbon consumption of roots and its impact on grain yield of spring wheat (Triticum aestivum L.) as affected by water and phosphorus (P) supply. A factorial design was used with six treatments namely two water regimes (at 80–75% and 50–45% ifeld capacity (FC)) and three P supply rates (P1=0, P2=44 and P3=109 μg P g–1 soil). At shooting and lfowering stages, root respiration and carbon consumption increased with the elevate of P supply rates, regardless of water conditions, which achieved the minimum and maximum at P1 under 50–45% FC and P3 under 80–75% FC, respectively. However, total aboveground biomass and grain yield were higher at P2 under 80–75% FC; and decreased with high P application (P3). The results indicated that rational or low P supply (80–75% of ifeld water capacity and 44 mg P kg–1 soil) should be recommended to improve grain yield by decreasing root carbon consumption in semiarid areas.展开更多
Rural drinking water safety is a growing concern in China. This study investigated the health risk of pollution of groundwater for the drinking water supply in Mingshan County, Ya'an City, in Sichuan Province, China,...Rural drinking water safety is a growing concern in China. This study investigated the health risk of pollution of groundwater for the drinking water supply in Mingshan County, Ya'an City, in Sichuan Province, China, using 46 samples from the years 1991 to 2010. Carcinogenic, non-carcinogenic, and total risks were assessed by the model recommended by the United States Environmental Protection Agency (U.S. EPA). Thematic maps of the risks caused by single and multiple factors were generated from inverse distance weighting interpolation (IDW) and the geostatistical analysis functions of ArcGIS. The results show that the carcinogenic risks caused by chemicals in groundwater for drinking water supply are low, within the acceptable interval for risk management. However, non-carcinogenic risks are high and the number of sampling sites with risk values exceeding the standards amounted to 29. Non-carcinogenic risks of Cr6+, nitrate, fluoride, and Fe at sites 43, 46, 50, 64, 67, and 74 were the sources that caused high total health risk. This study reveals the risk level of groundwater quality and orders of treatment of pollutants, and provides a scientific basis for groundwater management in this area.展开更多
基金Scientific Research Fund of Institute of Engineering Mechanics,China Earthquake Administration under Grant Nos.2021EEEVL0204 and 2018A02。
文摘As an important part of nonstructural components,the seismic response of indoor water supply pipes deserves much attention.This paper presents shaking table test research on water supply pipes installed in a full-scale reinforced concrete(RC)frame structure.Different material pipes and different methods for penetrating the reinforced concrete floors are combined to evaluate the difference in seismic performance.Floor response spectra and pipe acceleration amplification factors based on test data are discussed and compared with code provisions.A seismic fragility study of displacement demand is conducted based on numerical simulation.The acceleration response and displacement response of different combinations are compared.The results show that the combination of different pipe materials and different passing-through methods can cause obvious differences in the seismic response of indoor riser pipes.
基金funded by the China National Key Research and Development Program(No.2022YFC3003505)the Fundamental Research Fund for the Central Public-interest Scientific Institutes(No.DQJB23Y01)+1 种基金the National Natural Science Foundation of China(No.52278540)the Fundamental Research Fund for the Central Public-interest Scientific Institutes(No.DQJB22B28).
文摘In 2023,two consecutive earthquakes exceeding a magnitude of 7 occurred in Türkiye,causing severe casualties and economic losses.The damage to critical urban infrastructure and building structures,including highways,railroads,and water supply pipelines,was particularly severe in areas where these structures intersected the seismogenic fault.Critical infrastructure projects that traverse active faults are susceptible to the influence of fault movement,pulse velocity,and ground motions.In this study,we used a unique approach to analyze the acceleration records obtained from the seismic station array(9 strong ground motion stations)located along the East Anatolian Fault(the seismogenic fault of the MW7.8 mainshock of the 2023 Türkiye earthquake doublet).The acceleration records were filtered and integrated to obtain the velocity and displacement time histories.We used the results of an on-site investigation,jointly conducted by China Earthquake Administration and Türkiye’s AFAD,to analyze the distribution of PGA,PGV,and PGD recorded by the strong motion array of the East Anatolian Fault.We found that the maximum horizontal PGA in this earthquake was 3.0 g,and the maximum co-seismic surface displacement caused by the East Anatolian Fault rupture was 6.50 m.As the fault rupture propagated southwest,the velocity pulse caused by the directional effect of the rupture increased gradually,with the maximum PGA reaching 162.3 cm/s.We also discussed the seismic safety of critical infrastructure projects traversing active faults,using two case studies of water supply pipelines in Türkiye that were damaged by earthquakes.We used a three-dimensional finite element model of the PE(polyethylene)water pipeline at the Islahiye State Hospital and fault displacement observations obtained through on-site investigation to analyze pipeline failure mechanisms.We further investigated the effect of the fault-crossing angle on seismic safety of a pipeline,based on our analysis and the failure performance of the large-diameter Thames Water pipeline during the 1999 Kocaeli earthquake.The seismic method of buried pipelines crossing the fault was summarized.
文摘This research project investigates the current status of water supply, sanitation, and hygiene practices in Munshiganj District, Bangladesh. Data collection involved a structured questionnaire and a reconnaissance survey. Findings reveal that 30% of individuals rely on surface water (hand-tube wells, rivers, and ponds), prioritized as canal > river > pond, while 70% depend on groundwater (subterranean electric motor, deep tube-well). Drinking water is generally sufficient, with 95% reporting adequacy throughout the year. About 45% use hand tube-well water, 28% use deep tube-well water, and 11% use supply tap water for various purposes. Bathing trends include underground water through electric motor > pond > hand tube-well water > river, while for cooking, the order is underground water through electric motor > pond > hand tube-well water > river. Toilet water supply ranks as supply tap water > hand tube-well water > deep tube-well water. Although sanitation awareness is high, some lack knowledge of good hygiene practices. After defecating, handwashing methods include soap, ash, soil, or water. Children’s waste disposal varies, with some discarding it in open areas. Approximately 40% suffer from diseases like Diarrhoea due to unsafe water, primarily affecting children and elders. Training exists, but a significant portion lacks sanitation education. Dry skin or exposure to cold water may cause temporary irritation. Local government involvement in sanitation efforts is less active compared to non-governmental organizations. Results emphasize the need to enhance community awareness of safe water supplies and sanitation practices. .
文摘With the acceleration of urbanization,the demand for water supply and drainage pipe networks has increased significantly.In the planning of urban construction,it is necessary to optimize the design of the water supply and drainage system pipe network to effectively save energy while providing residents with more accessible water resources.Therefore,the municipal water supply and drainage system and the water transmission methods should be designed according to the geographical conditions of the city.In this paper,we mainly analyze the design of municipal water supply and drainage systems and the selection of water transmission methods.Besides,the optimization of the water supply and drainage network zoning process and pipe network maintenance is also discussed,so as to provide a reference for municipal water supply and drainage work.
文摘The quality and safety of residents’water rely heavily on the design of municipal water supply and drainage pipes.Therefore,this paper aims to enhance the optimization of municipal water supply and drainage pipe design by focusing on design requirements,principles,and key elements.Drawing from relevant design optimization experiences,technology advancements,and optimization measures,the research will analyze and consolidate the essential aspects of municipal water supply and drainage pipe design.The goal is to fundamentally elevate the quality standards of these designs,ensuring they meet the criteria for engineering project excellence.Through this comprehensive approach,we aim to contribute to the improvement and sustainability of water supply and drainage systems,safeguarding the well-being of residents.
基金supported by the National Natural Science Foundation of China(Grants No.52179062 and 51879087).
文摘For a water supply system with long-distance diversion pipelines, in addition to the water hammer problems that occur beyond pumps, the safety of the water diversion pipeline in front of pumps also deserves attention. In this study, a water hammer protection scheme combined with an overflow surge tank and a regulating valve was developed. A mathematical model of the overflow surge tank was developed, and an analytical formula for the height of the overflow surge tank was derived. Furthermore, a practical water supply project was used to evaluate the feasibility of the combined protection scheme and analyze the sensitivity of valve regulation rules. The results showed that the combined protection scheme effectively reduced the height of the surge tank, lessened the difficulties related to construction, and reduced the necessary financial investment for the project. The two-stage closing rule articulated as fast first and then slow could minimize the overflow volume of the surge tank when the power failure occurred, while the two-stage opening rule articulated as slow first and then fast could be more conducive to the safety of the water supply system when the pump started up.
基金financial support from the National Natural Science Foundation of China(52103064 and U21A2095)the Key Research and Development Program of Hubei Province(2021BAA068)National Local Joint Laboratory for Advanced Textile Processing and Clean Production(FX2022001)。
文摘Tailoring water supply to achieve confined heating has proven to be an effective strategy for boosting solar interfacial evaporation rates.However,because of salt clogging during desalination,a critical point of constriction occurs when controlling the water rate for confined heating.In this study,we demonstrate a facile and scalable weaving technique for fabricating core-sheath photothermal yarns that facilitate controlled water supply for stable and efficient interracial solar desalination.The core-sheath yarn comprises modal fibers as the core and carbon fibers as the sheaths.Because of the core-sheath design,remarkable liquid pumping can be enabled in the carbon fiber bundle of the dispersed superhydrophilic modal fibers.Our woven fabrics absorb a high proportion(92%)of the electromagnetic radiation in the solar spectrum because of the weaving structure and the carbon fiber sheath.Under one-sun(1 kW·m^(-2))illumination,our woven fabric device can achieve the highest evaporation rate(of 2.12kg·m^(-2)·h^(-1) with energy conversion efficiency:93.7%)by regulating the number of core-sheath yarns.Practical application tests demonstrate that our device can maintain high and stable desalination performance in a 5 wt%NaCl solution.
基金supported by the three funds:Industry-University-research Project of Anhui Jianzhu University HYB20210116National Key Research and Development Project of China No.2017YFC0704100(entitled New Generation Intelligent Building Platform Techniques)Research Project of Anhui Jianzhu University jy2021-c-017(Project Name:Research and Application ofWater Distribution Network Leakage Detection System Based on DMA Partition).
文摘At present,the leakage rate of the water distribution network in China is still high,and the waste of water resources caused by water distribution network leakage is quite serious every year.Therefore,the location of pipeline leakage is of great significance for saving water resources and reducing economic losses.Acoustic emission technology is the most widely used pipeline leak location technology.The traditional non-stationary random signal de-noising method mainly relies on the estimation of noise parameters,ignoring periodic noise and components unrelated to pipeline leakage.Aiming at the above problems,this paper proposes a leak location method for water supply pipelines based on a multivariate variational mode decomposition algorithm.This method combines the two parameters of the energy loss coefficient and the correlation coefficient between adjacent modes,and adaptively determines the decomposition mode number K according to the characteristics of the signal itself.According to the correlation coefficient,the effective component is selected to reconstruct the signal and the cross-correlation time delay is estimated to determine the location of the pipeline leakage point.The experimental results show that this method has higher accuracy than the cross-correlation method based on VMD and the cross-correlation method based on EMD,and the average relative positioning error is less than 2.2%.
文摘With the continuous development of society and the market economy,people are putting forward higher and higher requirements for the construction,technology,and environmental friendliness of buildings.The prefabricated building not only has high installation efficiency,but is also safe and environmentally friendly,which is in line with the green building concept.The drainage design is a critical part of prefabricated buildings.In order to ensure the quality and construction efficiency of the building project,it is necessary to design the building water supply and drainage properly.Therefore,an in-depth investigation on prefabricated buildings was carried out in this paper,and water supply and drainage design for prefabricated buildings under the green building concept is proposed,in hopes of providing references for future water supply and drainage designs.
文摘The potability of drinking water depends not only on the source and the treatment system, but also on the quality of the waterworks. In fact, the quality of drinking water is considerably degraded by the dilapidated state and lack of maintenance of drinking water networks. In Côte d’Ivoire, the majority of drinking water networks in the various towns are ageing. In Daloa, despite the efforts made by the company in charge of water treatment and distribution to make the water drinkable, the water at consumers’ taps is often colored, has an unpleasant aftertaste and settles after collection. As a result, people are concerned about the potability of tap water, and some are turning to alternative sources of drinking water of unknown quality. In order to determine the factors responsible for the deterioration in water color and taste, as well as the sectors of the network most affected, a diagnosis of the network’s equipment was carried out. Water samples taken from the network were analyzed for color and turbidity. The diagnosis revealed that most of the equipment (suction pads, valves, drains and fire hydrants) is outdated and irregularly maintained. Analyses show that the water is more colored in cast-iron and PVC pipes than in asbestos cement pipes. Coloration values in the network range from 0 to 27 UVC for asbestos cement pipes, from 15 to 56 UCV for ductile iron pipes, and from 11 to 102 UCV for PVC pipes. On the over hand, turbidity values vary from 8.02 to 3.32 NTU for ductile cast iron pipes, 8.51 to 16.98 NTU for asbestos cement pipes and 0.9 to 6.98 NTU for PVC pipes. Old cast-iron pipes release ferric ions on contact with water, degrading their color. Old cast-iron pipes release ferric ions into the water, degrading its color. The high color values observed in the vicinity of drains are thought to be due to irregular maintenance of the network. In fact, after network maintenance, a reduction rate ranging from 2% to 73% is observed for turbidity, while for color, the rate varies from 5% to 72%. In short, the network’s obsolescence and irregular maintenance contribute significantly to the deterioration of water quality.
文摘This study used multinomial logistic regression and Bayesian belief networks(BBN)to analyze factors influenc-ing the functionality of the community-based rural drinking water supply and sanitation program(PAMSIMAS)in Indonesia.28,936 PAMSIMAS projects in 33 provinces in Indonesia were analyzed.The data indicates that 85.4%of the water supply systems were fully functioning,9.1%were partially functioning,and 5.5%were not functioning.In the regression analysis,good management is positively associated with functionality and a high investment per capita is negatively associated with the functionality.The latter suggests the need for comprehen-sive economic analysis in the feasibility study in scattered housing sites and remote-undeveloped areas.We also found that high community participation at the beginning of the project was associated with the not functioning system,while women’s participation was positively associated with the functionality.Furthermore,the household connection is more likely to be functioning than communal connection.BBN analysis shows if the beneficiaries do not pay for water,the probability of not functioning systems is 20 times higher than systems with fee collec-tion.Moreover,the combination of strong management,strong financial status,and household connection rather than communal connection increases the probability of fully functioning to 98%.Improvement of data collection is also necessary to monitor the current conditions of all PAMSIMAS systems in Indonesia.This study offers a country-level perspective for better implementation of the community-based rural water supply and sanitation program in developing countries.
文摘During the Northern Warlord Period(1912–1928),the construction industry in Shanghai underwent robust development.As an integral element of buildings,equipment served both functional purposes and stood witness to the evolution of the economy and society,thus earning its place as part of the architectural heritage.However,due to various reasons,there are many loopholes in the protection of these building equipment.This paper examines the development of building equipment in Shanghai during the Northern Warlord Period,using water supply,drainage,and heating,ventilation,and air conditioning(HVAC)systems as examples.Through historical context analysis,it summarizes this development from a social-spatial perspective,infers the reasons behind it,and analyzes the importance of preserving such equipment,considering both past and present viewpoints.In this research,the importance of protecting historical building equipment is emphasized,which aims to give people a deeper understanding of their cultural value,and suggests that scholars conduct more practical research on their protection.
文摘[Objective] The aim was to study the effects of water supply and consumption on water saving and drought resistance. [Method] Controlling field experiment was conducted to explore water balance between supply and demand in paddy fields in hilly regions in Sichuan Province. [Result] Rainfall in hilly areas was 3 611.10 m3/hm2; water for irrigation was 6 299.25 m3/hm2; evapotranspiration of rice was 6 424.95 m3/hm2; deep leakage was 2 459.55 m3/hm2; overflowing amount was 1 026.00 m3/hm2. In addition, water consumption totaled 8 884.50 m3/hm2 during rice production; water use was 0.99 kg/m3 and use efficiency of irrigated water was 1.40 kg/m3. [Conclusion] Water supply and consumption should be further organized to save water and fight against drought in hilly areas in Sichuan Province.
文摘The paper had analyzed the technology, maintenance and recognition of vertical greening in urban space, and proposed a solution for balance water supply for balconies and streetlights, that is, magnetic auxiliary shallow water level controller, the patent of which had been applied. Magnetic auxiliary shallow water level controller had met water supply of some special parts of urban vertical greening and was sure to accelerate urban vertical greening.
基金Supported by the National Basic Research Program of China(973 Program,2010CB955905)the Fund of Chengde Municipal Finance Bureau(CZ2013004)~~
文摘[Objective] The purpose of this study is to estimate water supply and demand, which can provide a basis for how to allocate rationally water resources in Hotan Oasis. [Method] The water supply and demand in Hotan Oasis in the next15 years were calculated according to water-soil balance. [Result] When the runoff of Hotan River is at a probability of 50%(P=50 for short), the total water resource is 50.57×10^8m^3, and there is only 33.13×10^8m^3available for social and economics,but there would be a need of 33.44×10^8and 36.06×10^8m^3, and the water shortage would be 1.31 ×10^8and 2.93 ×10^8m^3in 2020 and 2030 respectively. When P =75,the total water resource is 44.30×10^8m^3, there is only 29.39×10^8m^3water available for social and economics. However, there would be a need of 31.43 ×10^8and33.11×10^8m^3, and the water shortage would be 2.04×10^8and 3.72×10^8m^3in 2020 and 2030, respectively. [Conclusion] The problem of water shortage would be serious over the next 15 years, and the fragile ecosystem would be destroyed dramatically with the large-scale land reclamation against natural laws. Hence, the effective policies and measures should be taken timely to prohibit reclamation and to cope with ongoing water shortage, based on the water supply and demand estimation under the background of climate change.
文摘In this research, LINGO is used successfully to solve the water supply system′s optimal operation model. Firstly, the language of LINGO and the using method were studied intensively, on the basis of which the model was transformed to LINGO form and solved successfully. Secondly, the research on the interface between LINGO and the popular office software was made. The optimization software was developed, which had Excel as the workspace and LINGO as the core of computation. Through practice, this software was found stable, easy to use and suitable for the application to the water supply corporations.
基金This work was supported by the Knowledge Innovation Program from the Cold and Add Regions Environmental and Engineering Research Institute, Chinese Academy of Sciences (CACX2003102)the Chinese Academy of Sciences (KZCX 1 - 10-03-01)the National Natural Science Foundation of China (40401012).
文摘Based on the data for meteorology, hydrology, soil, planting, vegetation, and socio-economic development of the irrigation region in the middle reaches of the Heihe River basin, Northwest China, the model of balance of water supply and demand in the region was established, and the security of water resource was assessed, from which the results that the effects of unified management of water resources in the Heihe River basin between Gansu Province and Inner Mongolia on regional hydrology are significant with a decrease in water supply diverted from Heihe River and an increase in groundwater extracted. In addition, it was found that the groundwater level has been steadily decreasing due to over pumping and decrease in recharges. In present year (2003), the volume of potential groundwater in the irrigation districts is far small because of the groundwater overdraft; even in the particular regions, there is no availability of groundwater resources for use. By 2003, water supply is not sufficient to meet the water demand in the different irrigation districts, the sustainable development and utilization of water resources are not secured, and the water supply crisis occurs in Pingchuan irrigation district. Achieving water security for the sustainable development of society, agriculture, economy, industry, and livelihoods while maintaining or improving the abilities of the management and planning of water resources, determining of the reasonable percentage between water supply and groundwater utilization and water saving in agricultural irrigation are taken into account. If this does not occur, it is feared that the present performance of water development and planning may further aggravate the problem of scarcities of water resources and further damage the fragile ecological system.
基金supported by the National Nature Science Foundation of China (31300328, 31200335, 31470496)the "111" Program from State Administration of Foreign Experts Affairs (SAFEA) & Ministry of Education (MOE), China (2007B051)+1 种基金the Fundamental Research Funds for the Central Universities, China (lzujbky-2012-97, lzujbky-2015-ct02, lzujbky-2016-86)the funding from the State Key Laboratory of Grassland Agro-ecosystem in Lanzhou University, China
文摘In semiarid areas, cereal crops often alocate more biomass to root at the expense of aboveground yield. A pot experiment was conducted to investigate carbon consumption of roots and its impact on grain yield of spring wheat (Triticum aestivum L.) as affected by water and phosphorus (P) supply. A factorial design was used with six treatments namely two water regimes (at 80–75% and 50–45% ifeld capacity (FC)) and three P supply rates (P1=0, P2=44 and P3=109 μg P g–1 soil). At shooting and lfowering stages, root respiration and carbon consumption increased with the elevate of P supply rates, regardless of water conditions, which achieved the minimum and maximum at P1 under 50–45% FC and P3 under 80–75% FC, respectively. However, total aboveground biomass and grain yield were higher at P2 under 80–75% FC; and decreased with high P application (P3). The results indicated that rational or low P supply (80–75% of ifeld water capacity and 44 mg P kg–1 soil) should be recommended to improve grain yield by decreasing root carbon consumption in semiarid areas.
基金supported by National Natural Science Foundation of China(61233004,61221003,61374109,61104091,61304078,61473184)National Basic Research Program of China(973 Program)(2013CB035500)+2 种基金the International Cooperation Program of Shanghai Science and Technology Commission(12230709600)the Higher Education Research Fund for the Doctoral Program of China(20120073130006,20110073110018)the China Postdoctoral Science Foundation(2013M540364)
基金supported by the Key Project Fund of the Sichuan Education Department (Grant No. 09ZA063),the Education Reform Project Fund of the Sichuan Education Department (Grant No. P09150)the National Innovative Project for College Students (Grant No. 00509204)the Youth Science and Technology Innovation Fund of Sichuan Agricultural University (Grant No. 00530300),the Talent Introduction Fund of Sichuan Agricultural University (Grant No. 00530301),and the Double-Support Plan of Sichuan Agricultural University (Grant No. 00570103)
文摘Rural drinking water safety is a growing concern in China. This study investigated the health risk of pollution of groundwater for the drinking water supply in Mingshan County, Ya'an City, in Sichuan Province, China, using 46 samples from the years 1991 to 2010. Carcinogenic, non-carcinogenic, and total risks were assessed by the model recommended by the United States Environmental Protection Agency (U.S. EPA). Thematic maps of the risks caused by single and multiple factors were generated from inverse distance weighting interpolation (IDW) and the geostatistical analysis functions of ArcGIS. The results show that the carcinogenic risks caused by chemicals in groundwater for drinking water supply are low, within the acceptable interval for risk management. However, non-carcinogenic risks are high and the number of sampling sites with risk values exceeding the standards amounted to 29. Non-carcinogenic risks of Cr6+, nitrate, fluoride, and Fe at sites 43, 46, 50, 64, 67, and 74 were the sources that caused high total health risk. This study reveals the risk level of groundwater quality and orders of treatment of pollutants, and provides a scientific basis for groundwater management in this area.