At present,industrial synthetic ammonia was still obtained through the Hubble-Bosch process,with large energy consumption.It is a research hotspot to realize green synthetic ammonia by using solar energy.The difficult...At present,industrial synthetic ammonia was still obtained through the Hubble-Bosch process,with large energy consumption.It is a research hotspot to realize green synthetic ammonia by using solar energy.The difficulty of photocatalytic ammonia synthesis was that the photo-excited electrons have not enough energy to active N≡N.In this study,Ti was doped into BiOBr by one-step hydrothermal method,which was oxidized into TiO_(2)when the doping amount reaches the maximum,in situ forming Ti_(0.31)B_(0.69)OB/TiO_(2)composites.Benefiting from the synergistic effect of Ti doping and S-scheme heterojunction,the synthetic ammonia efficiency of Ti_(0.31)B_(0.69)OB/TiO_(2)-11.96 reached 1.643 mmol·g_(cat)^(-1)at mild conditions and without hole scavenger for up to 7 h,the efficiency of synthetic ammonia is 115 times,10.5 times and 3.3 times of that of BiOBr,Ti_(0.31)B_(0.69)OB and TiO_(2),respectively.Specifically,DFT calculation confirms that Ti doping accurately refine the electronic structure of BiOBr,facilitate nitrogen adsorption activation and reduce hydrogenation reaction energy barrier,thus accelerating the reaction kinetics of photocatalytic nitrogen reduction(NRR),Meanwhile,constructing S-scheme heterojunction boosts the separation and transfer of photogenerated electron-hole pairs,improving the reduction ability of electrons in the conduction band of TiO_(2)and the oxidation ability of holes in the valence band of Ti_(0.31)B_(0.69)OB.展开更多
Effect of initial interference fit on pull-out strength in cementless fixation between bovine tibia and smooth stainless steel post was investigated in this study. Compressive behavior of bovine spongious bone was stu...Effect of initial interference fit on pull-out strength in cementless fixation between bovine tibia and smooth stainless steel post was investigated in this study. Compressive behavior of bovine spongious bone was studied using mechanical testing in order to evaluate the elastic-plastic properties in different regions of the proximal tibia. Friction tests were carried out in the aim to evaluate the friction behavior of the contact between bovine spongious bone and stainless steel. A cylindrical stainless steel post inserted in a pre-drilled bovine tibia with an initial interference fit was taken as an in vitro model to assess the contribution of post fixation to the initial stability of the Total Knee Arthroplasty (TKA) tibial component. Pull-out experiments were carried out for different initial interference fits. Finite Element Models (FEM) using local elastic-plastic properties of the bovine bone were developed for the analysis of the experimental ultimate pull-out force results. At the post/bone interface, Coulomb friction was considered in the FEM calculations with pressure-dependent friction coefficient. It was found that the FEM results of the ultimate force are in good agreement with the experimental results. The analysis of the FEM interfacial stresses indicates that the micro-slip initiation depends on the local bone properties.展开更多
Summary: This study evaluated the clinical effect of impaction bone graft and distal press-fit fixation for the reconstruction of severe femoral bone defect in revision total hip arthroplasty. A total of 234 patients...Summary: This study evaluated the clinical effect of impaction bone graft and distal press-fit fixation for the reconstruction of severe femoral bone defect in revision total hip arthroplasty. A total of 234 patients (involving 236 hips) with Paprosky III and 1V femoral bone defects were treated with the revision total hip arthroplasty from June 1998 to Aug. 2006. Impaction bone graft technique was used for 112 hips, with allogeneic freeze-dried bone as bone graft and SP II as prosthesis. With 124 hips, modular distal press-fit fixation and tapered femoral stem (MP stem) were employed. After the operation, the subjects were followed up on regular basis and results were assessed by using the Harris Hip Score (HHS) and 12-item Short Form Health Survey (SF-12). Radiolucence, subsidence and loosening were observed and complications, including infection, fracture, dislocation etc. were recorded. A 6-14-year follow-up showed that prostheses failed, due to infection, in 4 patients of impaction bone graft group and that 6 patients in the press-fit fixation group experienced prosthesis failure, with the survival rates for the two techniques being 96.43% and 95.16%, respectively. One-way ANOVA showed that prosthesis survival was significantly associated with surgery-related complications (P〈0.05) and was not related to the type of the bone defects (P〉0.05). The rate of complications bore significant association with the type of bone defects in the two groups (P〈0.05). Our study showed that the two revision methods could achieve satisfactory mid-term and long-term results for the reconstruction of severe bone defects. It is of great significance for attaining high prosthesis survival rate to select suitable operation on the basis of the type of bone defect. Careful operative manipulation and post-operative rehabilitation aimed at reducing complications are also important.展开更多
基金financially supported by the National Natural Science Foundation of China(Nos.22168040 and 22162025)the Project of Science&Technology Office of Shannxi Province(No.2022JM-062)。
文摘At present,industrial synthetic ammonia was still obtained through the Hubble-Bosch process,with large energy consumption.It is a research hotspot to realize green synthetic ammonia by using solar energy.The difficulty of photocatalytic ammonia synthesis was that the photo-excited electrons have not enough energy to active N≡N.In this study,Ti was doped into BiOBr by one-step hydrothermal method,which was oxidized into TiO_(2)when the doping amount reaches the maximum,in situ forming Ti_(0.31)B_(0.69)OB/TiO_(2)composites.Benefiting from the synergistic effect of Ti doping and S-scheme heterojunction,the synthetic ammonia efficiency of Ti_(0.31)B_(0.69)OB/TiO_(2)-11.96 reached 1.643 mmol·g_(cat)^(-1)at mild conditions and without hole scavenger for up to 7 h,the efficiency of synthetic ammonia is 115 times,10.5 times and 3.3 times of that of BiOBr,Ti_(0.31)B_(0.69)OB and TiO_(2),respectively.Specifically,DFT calculation confirms that Ti doping accurately refine the electronic structure of BiOBr,facilitate nitrogen adsorption activation and reduce hydrogenation reaction energy barrier,thus accelerating the reaction kinetics of photocatalytic nitrogen reduction(NRR),Meanwhile,constructing S-scheme heterojunction boosts the separation and transfer of photogenerated electron-hole pairs,improving the reduction ability of electrons in the conduction band of TiO_(2)and the oxidation ability of holes in the valence band of Ti_(0.31)B_(0.69)OB.
文摘Effect of initial interference fit on pull-out strength in cementless fixation between bovine tibia and smooth stainless steel post was investigated in this study. Compressive behavior of bovine spongious bone was studied using mechanical testing in order to evaluate the elastic-plastic properties in different regions of the proximal tibia. Friction tests were carried out in the aim to evaluate the friction behavior of the contact between bovine spongious bone and stainless steel. A cylindrical stainless steel post inserted in a pre-drilled bovine tibia with an initial interference fit was taken as an in vitro model to assess the contribution of post fixation to the initial stability of the Total Knee Arthroplasty (TKA) tibial component. Pull-out experiments were carried out for different initial interference fits. Finite Element Models (FEM) using local elastic-plastic properties of the bovine bone were developed for the analysis of the experimental ultimate pull-out force results. At the post/bone interface, Coulomb friction was considered in the FEM calculations with pressure-dependent friction coefficient. It was found that the FEM results of the ultimate force are in good agreement with the experimental results. The analysis of the FEM interfacial stresses indicates that the micro-slip initiation depends on the local bone properties.
基金supported by a grant from the National High Technology Research and Development Program of China(863 Program)(NO.2011AA030101)
文摘Summary: This study evaluated the clinical effect of impaction bone graft and distal press-fit fixation for the reconstruction of severe femoral bone defect in revision total hip arthroplasty. A total of 234 patients (involving 236 hips) with Paprosky III and 1V femoral bone defects were treated with the revision total hip arthroplasty from June 1998 to Aug. 2006. Impaction bone graft technique was used for 112 hips, with allogeneic freeze-dried bone as bone graft and SP II as prosthesis. With 124 hips, modular distal press-fit fixation and tapered femoral stem (MP stem) were employed. After the operation, the subjects were followed up on regular basis and results were assessed by using the Harris Hip Score (HHS) and 12-item Short Form Health Survey (SF-12). Radiolucence, subsidence and loosening were observed and complications, including infection, fracture, dislocation etc. were recorded. A 6-14-year follow-up showed that prostheses failed, due to infection, in 4 patients of impaction bone graft group and that 6 patients in the press-fit fixation group experienced prosthesis failure, with the survival rates for the two techniques being 96.43% and 95.16%, respectively. One-way ANOVA showed that prosthesis survival was significantly associated with surgery-related complications (P〈0.05) and was not related to the type of the bone defects (P〉0.05). The rate of complications bore significant association with the type of bone defects in the two groups (P〈0.05). Our study showed that the two revision methods could achieve satisfactory mid-term and long-term results for the reconstruction of severe bone defects. It is of great significance for attaining high prosthesis survival rate to select suitable operation on the basis of the type of bone defect. Careful operative manipulation and post-operative rehabilitation aimed at reducing complications are also important.